INSTRUCTION TO THE USER
FCC ID: NNHRK100M
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more or the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet of a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC
regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to
radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the
3321906 6356
SPECIFICATIONS:
POWER REQUIREMENTS
5-14 VDC, 90 mA
OUTPUTS
SPST Solid State Relay, 1A max. @60 VAC or DC
Normally open or normally closed (field programmable
(See Operating Guide). For RK-65K, RK-65KS and RK-100M only.
INPUTS
Default is Remote Open (requires contact closure). For RK-65K, RK-65KS and
RK-100M only.
Also programmable as Bicolor (Red or Green) LED Control or Buzzer/LED control
for online systems (see Operating Guide).
WIEGAND OUTPUT
Any Wiegand Format up to 40 bits
Maximum Distance: 500 ft. - 5 or 6 conductor 20 gauge shielded cable
ENVIRONMENT
Access Control Unit, Key Tags and Cards
Ambient Temperature -40° to +70°C (-40° to +158°F)
Humidity 0 to 95% (non-condensing)
PARTS SUPPLIED:
Access Control Unit
MOV (RK100M, RK65K & RK65KS only)
Operating Guide (RK100M, RK65K & RK65KS only)
Installation Instructions all Models
Log Sheet (RK-65K, RK-100M only)
Mounting Plate (RK-WS, RK65KS only)
2, #6 Mounting Screws
1, 4x40 Screw (RK-WS, RK65KS only)
1, Security Screw (RK-WS, RK65KS only)
Snap-In Labels (RK100M, RK65K only)
ACCESSORIES (NOT INCLUDED):
RK600-PS: 9VDC plug-in power supply. It is designed to
power the RK-100M, RK-65K and RK-65KS only, and
requires 120 VAC input.
RK-PD1: Proximity Programming Deck
RK-BB: Back Box/Spacer (RK-WS & RK65KS)
RK-HHP: Hand-Held Programmer (RK100M & RK65K)
SK-SR SecuRelay™ - Smart relay module, DPDT.
www.SecuraKeyStore.com
(800) 878-7829
European Community Approvals