Security Camera King CVIOB-TP1IRE User manual

HD-CVI Camera
User’s Manual
Welcome
ank you for purchasing our HD-CVI camera!
is user’s manual is designed to be a reference tool for
your system.
Please read the following safeguards and warnings care-
fully before you use this series of product!
Please keep this user’s manual for future reference!

Camera
Image Sensor AR0141
DSP
HTC960
Imag e Resolution
720P/960H
Effective Pixels
1.0MP, 1280x720
TV Sy stem
PAL/NTSC
Electronic Shutter
1/25slV 1/50,000s , 1/30s~1/60,000s
S/N Ratio ≥50dB
Prog ressive Scan
Lens
Focus Length
Focus Control
Lens Typ e
Pixels
Board Lens 3.6mm/F2.0
Fixed
Fixed
2M Pixels
Auto Iris Supp ort
NO
Night Vision
Infrared LED
Infrared Distance
IR Status
20M
Under 10 Lux by CDS
IR Power On
CDS Auto Control
Camera Features
Day/Nig ht Auto (ICR)
I
Color
I
B&W
NO
White Balance
Auto
Gain Control Auto
Noise Reduction
2D NR
Picture Adjustment
NO
WDR
NO
OSD Support
NO
UTC NO
General
Housing
Metal IP66
Bracket
Dual Voltag
e
IR Cut Filter
YES Anti-Cut Bracket
NO
YES
Heater
NO
Op
eration Temperature -10
℃
~ +50
℃
RH95% Max
Storage Temperature -20
℃
~ +60
℃
RH95% Max
Power Source
DC12V±10%, 500mA
Dimension
184(W) x 66( H) x 66( D) mm
Weight 700g
Scanning System
OSD Menu Language

Important Safeguards and warnings
1.Electrical Safety
All installation and operation should conform to your local electrical
safety codes.
e power shall conform to the requirement in the SELV (Safety Extra
Low Voltage) and the Limited power source is rated 12V DC (24V AC)
in the IEC60950-1.
We assume no liability or responsibility for any res or electrical shock
caused by improper handling or installation.
2.Transportation Security
Heavy stress, violent vibration or water splash are not recommended
during transportation, storage, and installation.
3.Installation
Do not apply power to the camera before completing installation.
Please install the proper power cut-o device during the installation
connection.
Always follow the instruction guide the manufacturer recommended.
If this product is installed in the ceiling, please make sure this installa-
tion position can sustain the min 11 Lbs.
4.Qualied Engineers Needed
All the examination and repair work should be done by a qualied ser-
vice engineer.
We are not liable for any problems caused by unauthorized modica-
tions or attempted repair.
5.Environment
is series camera should be installed in a cool, dry place away from di-
rect sunlight or strong light, inammable, explosive substance and etc.

Important Safeguards and Warnings
is series camera should be used in the specied working
temperature. Please keep it away from electromagnetic radi-
ation enviroments.
Please keep the camera ventilated.
Do not allow water and other liquid into the camera.
6.Accessories
Be sure to use all the accessories recommended by the man-
ufacturer.
Before installation, please open the package and check all
the components that are included.
Contact your local retailer ASAP if something is broken in
your package.
7.Daily Maintenance
Please shut down the device and then unplug the power ca-
ble before you begin daily maintenance work.
Use the dry so cloth to clean the device.
If there is too much dust, please use water to dilute the mild
detergent rst and then use it to clean the device. Finally
use the dry cloth to clean the device.
Please put the dustproof cap on to protect the CCD
(CMOS) component when you do not use the camera.

1General Introduction
1.1 Overview
is series megapixel HD camera conforms to the HD-CVI standard. It
supports high-speed, long-distance video transmission without any de-
lay. It can be controlled by the DVR conforming to HD-CVI.
1.2 Features
•High-performance CMOS image sensor, megapixel denition.
•Support HD video and control signal coaxial transmission.
•Supports 75-3 coaxial cable transmission without any loss. 720P se-
ries transmission distance over 500m, 1080p series transmission distance
300m.
•High speed, long distance real-time transmission
•Support HD-CVI HD.
•720p series supports 720p@30fps
•1080p series support 1080p@30fps
•Supports high performance 3D noise reduction; excellent perfor-
mance in low illumination.
•Support ICR switch to realize surveillance both in the daytime and
at night.
•3.6mm xed lens
•Support OSD (on-screen display), suitable for user self-dened set-
up, except on economy models.
•Supports DC12V power supply.
•IP66 compliance.
•Supports intelligent IR function.

2Dome Framework
Important
Dimensions of Cameras may vary depending on your mod-
el. If you are having trouble nding the dimensions you can
nd the measurements by using a caliper or a ruler. To nd
the circumference of the bottom of the camera use the fol-
lowing formula: Diameter of circle x 3.14(pi)
HD-CVI Metal Housing
1
Lens
Dome Body
Decoration Ring
Power
Video
SD/HD switch control cable

HD-CVI Plastic Housing
2
Lens
Dome Body
Decoration Ring

HD-CVI Glass Housing
3
Dome Cover
Dome Enclosure
IR Light
Dome Module
Dome Pedestal
Power Input Port
Video Output Port
SD/HD Switch Cable

When the Standard denition/high denition switch control cable is short
circuited, system outputs standard denition video. Otherwise, when the
circuit is open, system outputs the high denition video.
3Dome Installation
Important
Before the installation, please make sure the installation surface can sustain at
least 3 times the weight of the bracket and the camera.
3.1 HD-CVI Glass Housing
e dome camera is usually installed on a ceiling. Although, It could also be in-
stalled on a wall. For the side exit cable installation, please make sure the side exit
cable direction is the same as shown in the installation position map.
•Before you secure the screws on the pedestal, please pull the cable through
the cable exit of the pedestal.
•Do not remove the electrostatic lm until the installation is completed. Aer
you remove the lm, do not touch the enclosure in case there is any scratch.
Ceiling or Wall
Installation Position Map
Expansion Bolts
Self-Tapping Screw
Enclosure fastening screw
Inner Hex Wrench

Step 1
Take the installation position map from the accessories bag and put it on the
surface of the ceiling or the wall according to the cable exit position. Drill three
holes according to the installation position map and then take three expansion
bolts from the accessories bag and put them into the holes you just drilled.
Step 2
Use the inner hex wrench to remove the three enclosure fastening screws and
then remove the dome enclosure.
Step 3
Adjust the pedestal position according to the cable exit move(ceiling/side). Pull
the cable through the cable side exit at the installation surface and the pedestal.
(Please skip this step if you are mounting on a ceiling). Line up the screw holes
at the bottom of the pedestal to the expansion bolts in the installation surface.
Put three self-tapping screws to expansion bolts and then secure rmly. Now the
pedestal is on installation surface.
Step 4
Adjust the camera module angle to a proper position and then x the screws to
fasten.
Step 5
Use three enclosure fastening screws to secure the dome housing on the
pedestal.
Fastening Screw

HD-CVI Plastic Housing
Step 1
Please take the installation position map from the accessories bag, and then
paste it on the ceiling or the wall according to your monitor area requirements.
Draw and then drill three holes in the installation surface and then insert three
expansion bolts in the holes. Secure these three bolts rmly.
Step 2
Turn counter clockwise to remove the decoration ring. Please drill a “cable exit
hole” in the surface according to the installation position map if you want to
draw out the cable from the top of the installation surface. You need to draw out
the cable from the cable channel side port of the pedestal if you want to draw
out the cable from the side port of the cable channel. Adjust the device instal-
lation pedestal to the proper position and then draw the cable through the ca-
ble exit. Line up the three screw holes in the installation position. Put the three
self-tapping screws in the three plastic expansion bolts rmly. Now the dome
camera is secure in the installation surface.
3.2
Ceiling or Wall
Expansion Bolt
Dome Camera Body
ST3 Self-tapping Screws
Decoration Ring

Step 3
Adjust the lens to get a clear view of the area you want to monitor.
Step 4
Line up the decoration ring to the neck of the camera body and tighten in place.
Push and then turn decoration ring clockwise. e installation is completed
aer you secure the decoration ring. You need to use the proper tool to open up
the side port of the U-cable channel of the decoration ring if you want to draw
out the cable from the side port of the cable channel when you are installing
the device cable. en you can draw out the cable from the cable channel of the
pedestal. Finally you can install the decoration ring to complete the installation.
Cross-head Screwdriver
Adjustment Screw

Step 1 Adjust Monitor Angle
Turn the pan base to the pedestal to loosen or secure rmly. Adjust and rotate
base and the dome body to get the lens to the proper monitor angle.
HD-CVI Metal Housing
3.3
B1 Pedestal
B2 Pan Base
B3 Rotate Base
B4 Dome Body
Pedestal 1

4Bullet Framework
Important
Dimensions of Cameras may vary depending on your mod-
el. If you are having trouble nding the dimensions you can
nd the measurements by using a caliper or try your best
using a ruler. To nd the circumference of the bottom of
the camera use the following formula: Diameter of circle x
3.14(pi)
Sun Shield Cover
Lens
Bracket

5Bullet Installation
Important
Before the installation, please make sure the installation surface can sustain at
least 3X weight of the bracket and the camera.
2 Megapixel Camera
Before you install the bracket, please pull the cable through the cable exit of the
bracket chassis.
•install the expansion bolt if you want to install in cement wall (make sure
the installation holes of the expansion bolts are the same as the bracket) and
then you can install the bracket.
•If you want to install in a wood surface, please skip the rst step and then
use the self-tapping screws to install the bracket directly
Step 2
Unscrew the M3 x 20 and M3 x 5 screws on the bracket and adjust the camera
to the exact location which needs to be monitored by rotating the bracket and
camera body, then secure the bolts.

VariFocal Camera
Lower Cover
Lens Focal Lens
M2 5*5 Bolt
Unscrew M2 5*5 Bolt from the
lower cover of the camera. Remove
the Cover and adjust the VariFocal
(zoom) to your preference.

5Menu
HD-CVI Series DVR settings
5.1
e following operation and interfaces is for reference only. Please refer to
the HD-CVI series DVR user’s manual for detailed information.
Aer connecting the camera to the HD-CVI series DVR go to Main Menu
->Setting->System->PTZ. You need to set control mode as HD-CVI and the
protocol as HD-CVI. Click save button to save current setup.

On the preview interface, right click mouse and then select PTZ; you can see an
interface shown as below.
Click Iris “+” to open menu or conrm current operation. Click up/down but-
ton to view all the items on the le pane of the following list. Click le/right
button to set the corresponding values on the right pane of the following list. If
there is , click conrm button to go to the 2nd menu. Repeat the previous
steps to set detailed value. Click return button to go back to the previous menu
interface.
Table of contents
Other Security Camera King IP Camera manuals