Instruction Manual for IP20 rated PIR 360° Detector 1200W
for use on Industrial & Domestic Lighting Systems
Selectric Energy Savers Code: PIR360-FLU Infrared Motion Sensor
Introducing the Selectric Energy Savers Range Item PIR360-FLU infrared PIR
motion detector.
The product adopts an excellent sensitivity detector and integrated circuit for ease of wiring.
The device is saving-energy with a 360° detection radius. The product utilizes the infrared
energy from a person or animal when in the range radius of the unit’s detection field. It can
identify day and night automatically, is easy to install and used in a wide variety of applications.
PRODUCT SPECIFICATION:
Power Source: 220-240V/AC Detection Range: 360°
Power Frequency: 50Hz Detection Distance: 12m max(<24°)
Ambient Light: 3-2000LUX (adjustable) Working Temperature: -20° +40℃
Time Delay: Min.10sec±3sec Detection Motion Speed: 0.6-1.5m/s
Max.15min±2min Power Consumption: Approx 0.5W Max
Rated Load: Max.1200W Incandescent Power Consumption: Approx 0.1W Min
300W LED Detection Speed: 0.6-1.5m/s
Installation Height: 1.8-2.5m IP20 rated suitable for use in the
Installation cutout diameter 63 – 64mm Garage or indoors
FUNCTIONALITY:
ØThe sensor can identify day and night: The user can adjust the working state in
different ambient light. It can work in the daytime and at night when it is adjusted on
the “sun” position (max). It can work in the ambient light less than 3LUX when it is
adjusted to the “3” position (min). As for the adjustment pattern, please refer to
TESTING THE UNIT below.
ØTime-Delay is added continually: When a person or object moves continuously within
the radius the light timer resets.
CONNECTION:
ØRemove the transparent vinyl cover which covers the sensor’s connection terminals.
ØLoosen the screws in the connection terminals and using the correct cable, connect
the wires accordingly (see figure 1).
ØClamp the cable down using the cord grip provided with two screws.
ØInstall back the transparent vinyl cover into the original position.
ØFold the metal spring of the sensor upwards, until they are in “I” position with sensor,
and then put the sensor into the hole or installation box which has been cut out or
installed prior to wiring.
ØReleasing the spring, the sensor will be set in this installation position.
ØAfter the sensor has been securely fitted, turn on the power and then test the unit.
Testing the Unit: (See figure 1A)
ØTurn the TIME dial clockwise on to the minimum (-) while also turning the LUX dial
clockwise to the maximum (sun).
ØSwitch on the power; the sensor and its connected lamp will have no signal at the beginning.
After Warm-up 30sec, the sensor will start to work. If the sensor receives a signal within its
radius, the lamp will turn on. When there is no signal to activate the lamp then it will turn off
within 10sec±3sec.
ØTurn the LUX dial anti-clockwise on the minimum (10S). If the ambient light is more than
3LUX, the sensor would stay off and the lamp will not turn off also. If you cover the
detection window with an opaque object (towel, dark cloth etc), the sensor will work.
When there is no signal within the radius of the unit then the sensor should turn itself off
within 10sec±3sec.
Note: when testing in daylight, please turn LUX dial to the (SUN) position,
otherwise the sensor lamp may not work. If the lamp is more than 60W, the distance
between lamp and sensor should be 60cm at the least.
Problem Solving:
ØIf the load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
ØIf the sensitivity is poor:
a. Please check if there is any hindrance in front of the detection window which may
affect the signal being received.
b. Please check if the ambient temperature is too high or too low.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in this
instruction manual dependant on the wattage used.
e. Please check if the moving orientation is correct and no loose parts are showing
which may affect the sensor.
ØThe sensor cannot shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power / wattage corresponds to this instruction manual.
INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
ØAvoid pointing the detector towards objects with highly reflective surfaces, such as
mirrors, reflective glass, windows etc.
ØAvoid mounting the detector near heat sources, such as central heating, heating
vents, air conditioning units and artificial heat lamps etc.
ØAvoid pointing the detector or locating the detectors in places where objects or
household pets may continuously move.
ØIf in doubt always consult a qualified electrician before installation.

Popular Security Sensor manuals by other brands

urmet domus ELKRON IR600FC/RF quick guide

urmet domus

urmet domus ELKRON IR600FC/RF quick guide

Hytronik HCD405/BT Installation and instruction manual

Hytronik

Hytronik HCD405/BT Installation and instruction manual

Perenio PECWS01 quick start guide

Perenio

Perenio PECWS01 quick start guide

Orbit OSLPIR240B manual

Orbit

Orbit OSLPIR240B manual

Siemens FDOOTC241 Technical manual

Siemens

Siemens FDOOTC241 Technical manual

LMI Technologies Gocator 1300 quick start guide

LMI Technologies

LMI Technologies Gocator 1300 quick start guide

Leuze electronic MLC 500 Original operating instructions

Leuze electronic

Leuze electronic MLC 500 Original operating instructions

HTI HT-9600 Instructions for use

HTI

HTI HT-9600 Instructions for use

Omron F3SG-2RE0430P30 user manual

Omron

Omron F3SG-2RE0430P30 user manual

Mastitis 4x4 Q MAST manual

Mastitis

Mastitis 4x4 Q MAST manual

SKYLOTEC X-TREM DYNAMIK 11.0 Instructions for use

SKYLOTEC

SKYLOTEC X-TREM DYNAMIK 11.0 Instructions for use

ELRO FH380111R instruction manual

ELRO

ELRO FH380111R instruction manual

C.Nord CN-Celsius installation guide

C.Nord

C.Nord CN-Celsius installation guide

Vimar NEVE UP 09591.0 manual

Vimar

Vimar NEVE UP 09591.0 manual

Emerson Machinery Health AMS EZ 1000 operating manual

Emerson

Emerson Machinery Health AMS EZ 1000 operating manual

KingShield Orion Range OD101 manual

KingShield

KingShield Orion Range OD101 manual

MD mXion RBM user manual

MD

MD mXion RBM user manual

DSC WLS904-418 installation instructions

DSC

DSC WLS904-418 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.