Millions Depend on the Integrity of Your Product.
Sensitech’s Mission is to Ensure that Integrity.
TagAlert®Indicator
Instructions For Use
The Tools That Turn Information Into Power
For more information, contact our client services
group at 800-843-8367.
Sensitech Inc. • 800 Cummings Center, Suite 258X • Beverly, MA 01915
1-800-843-8367 • +1-978-927-7033 • Fax 978-921-2112 • www.sensitech.com
TempTale Manager®
Desktop Software
TempTale®4 Monitor
© 2014 Sensitech, Inc. All Rights Reserved. T83000034 Rev. H 07/09/14
RF Monitoring
TagAlert®Indicator
Data Management Services
TempTale®4 USB Monitor
AlarmAlert™ Feature
• Ifalarmed,theTagAlertindicatorprovidesamechanismtodetermineatwhichpointduring
 thetriptherstalarmwastriggered.ThisAlarmAlert™featurecanaccommodatetripsup
 to10daysinduration.
• ReadtheTagAlertandrecordwhichalarmshavetriggered(Figure 2).
• Followthenextthreestepstodeterminewhichalarmwastriggeredrstandtheapproximate
 timeatwhichthealarmtriggered:
1.PresstheStartbuttontodeterminewhichalarmtriggeredrst.Thenumberrepresent
  ingtherstalarmthattriggeredwillashfor4seconds.TheLCDdisplaywillthenclear
  for2seconds.
2. Thesumofthenumbersthatappearnextwillequalthedayintothetripthattherstalarm
was triggered (Figure 4).Thiswillbedisplayedfor2seconds.
3. Thesumofthenumbersthatappearnextwillindicatethe3-hourtimeintervalwithinthe
  daytherstalarmwastriggered(Figure 5).
• PresstheStartbuttonagaintorepeatsequenceofinformation.
Numbers Displayed on LCD Sum = Day of Trip
1 1st
2 2nd
3 3rd
44th
4 and 1 5th
4 and 2 6th
4 and 3 7th
4 and 3 and 1 8th
4 and 3 and 2 9th
4 and 3 and 2 and 1 10th
Numbers Displayed on LCD Sum Representing Time Interval Time Interval in 24 Hour Period
1 1st 0-3rdhour
2 2nd 3rd-6thhour
3 3rd 6th-9thhour
44th 9th-12thhour
4 and 1 5th 12th-15thhour
4 and 2 6th 15th-18thhour
4 and 3 7th 18th-21thhour
4 and 3 and 1 8th 21-24thhour
4 and 3 and 2 and 1 10th After10thday
Starting a TagAlert®Indicator
• PushtheSTARTbuttononthefrontofthedeviceandholdfor
 approximately1second.
• TheLCDdisplaywillrespondbydisplaying“OK”(Figure 1).
• Oncethe“OK”isdisplayed,theTagAlert®indicatorhasbeen
 activatedandentersthestart-updelayasprogrammedintotheunit.
• Onceactivated,removethebackstickerlabelandafxtoan
 instructioncardorattachdirectlytoaclean,drysurfaceofthe
 productorpackage.
Reading a TagAlert Indicator
• Oncethepackagehasarrivedatitsdestination,removethe
 TagAlertindicatorfromthepackage.
• IftheLCDdisplays“OK”,noalarmshavebeentriggered
 duringthetrip(Figure 1).
• IftheLCDdisplaysblacksquaresoverthe“OK”andthenumbers
 1,2,3and/or4,thenanalarmhasbeentriggered(Figure 2).
 Forexample,ifthenumbers1and4aredisplayed,thenthe1stand
 4thalarmconditionswereexceeded.
• Thereceivinglocationshouldfollowtheappropriateprotocolto
 determineproductdispositionifanalarmhastriggered.
Fail Safe Protection
• TheTagAlertindicatorperformsasystemcheckduringoperation
 andincorporatesaFail-Safeprotectionmodetoalerttheuser
 shouldtheunitfailtofunctionproperly.
• IftheTagAlertindicatordetectsafaultytemperaturesensororthe
 temperatureexceedstheoperationallimits(70ºC(158ºF)to-20ºC
 (-4ºF))intransit,theunitwillenterintothismodeandwill
 discontinuetemperaturemeasurement.
• TheLCDwilldisplayblacksquaresoverthe“OK”.Nonumbers
 willbedisplayedontheLCD(Figure 3).
NOTE: If any numbers appear on the LCD, that alarm has
triggered. The “OK” may still be visible through the black
squares even if an alarm has triggered.
NOTE: Days are calculated in 24 hour increments. This begins when the start button is
rst pressed and the “OK” is displayed on the LCD.
Figure 1
Figure 2
Figure 4
Figure 5
Figure 3

Other manuals for TagAlert

1

Popular Touch Panel manuals by other brands

Crestron 3200 Series Operation guide

Crestron

Crestron 3200 Series Operation guide

Nedlands Group FLS-RC-W installation manual

Nedlands Group

Nedlands Group FLS-RC-W installation manual

Emerson RXi quick start guide

Emerson

Emerson RXi quick start guide

perixx PERIPAD-504 user manual

perixx

perixx PERIPAD-504 user manual

DFI KS101-BT Quick installation guide

DFI

DFI KS101-BT Quick installation guide

Crestron TSW-570P Getting started

Crestron

Crestron TSW-570P Getting started

Elan XP84 installation manual

Elan

Elan XP84 installation manual

Eldes EWKB5 installation guide

Eldes

Eldes EWKB5 installation guide

Zennio Z41 Pro user manual

Zennio

Zennio Z41 Pro user manual

Advantech PPC-175T user manual

Advantech

Advantech PPC-175T user manual

Christ Elektronik Touch-it XPC operating instructions

Christ Elektronik

Christ Elektronik Touch-it XPC operating instructions

RIKA V2.23 operating instructions

RIKA

RIKA V2.23 operating instructions

Harman AMX MODERO S MSD-1001-L2 quick start guide

Harman

Harman AMX MODERO S MSD-1001-L2 quick start guide

Extron electronics TLP Pro 1230WTG Setup guide

Extron electronics

Extron electronics TLP Pro 1230WTG Setup guide

ABB ControlMaster CM15 user guide

ABB

ABB ControlMaster CM15 user guide

i3-TECHNOLOGIES i3TOUCH PXr Series manual

i3-TECHNOLOGIES

i3-TECHNOLOGIES i3TOUCH PXr Series manual

EMAC PPC-E4+ user manual

EMAC

EMAC PPC-E4+ user manual

Rinstrum 5230 Applications manual

Rinstrum

Rinstrum 5230 Applications manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.