12V Battery Backup UPS
Quick Install Guide
Introduction
This product (part # UPS-5AH-12V) is a
self-contained 12-volt DC battery backup
Uninterruptible Power Supply (UPS) containing
a internal, sealed lead acid battery. It is charged
from the vehicle’s electrical system, and provides
the Safe Fleet recorder (and any accessories
it powers) a constant, uninterruptible power
source.
Setpoints (see page 3) constantly monitor the
vehicle’s battery, and based on its condition
switch the voltage between the vehicle battery
and the backup (UPS) battery.
Read these instructions carefully before
installing this product.
A qualied service person, complying with all applicable codes, should perform the installation.
To use this document, you must have the following minimum qualications:
• Basic knowledge of electronic surveillance systems and components
• Familiarity with electrical wiring and low voltage electrical hookups
Support
• Phone: 1-844-899-7366
• Email: [email protected]
Service
If your UPS is to be returned for service, please call toll free 1.877.630.7366, or 1.844.899.7366,
and provide the model and/or serial# of your unit.
Ask for a Return Merchandise Authorization (RMA) number. An RMA# allows the Service
Technicians to better track your product when it comes in for service. Please show the RMA# on
the outside of the package. ANY PRODUCT SENT WITHOUT AN RMA# MAY BE REFUSED.
Documentation
Additional copies of this guide, along with other supporting
documentation can be found on the Safe Fleet Community:
• https://community.seon.com/documents/
Warranty
For full warranty information, visit:
www.seon.com/documents/Seon-Warranty.pdf
© Safe Fleet | 2019 | All rights reserved | Part #: 700-1201 R1
Location The UPS ts in inside a 6W X 6.5L X 5.5H (inches) / 15.2W x 16.5L x 14H
(centimeters) space. A shelf in the equipment cabinet is ideal.
Do not install the UPS in a location where the unit is exposed to excessive
moisture,heat, or dust.
Orientation Mount horizontally on a at surface. Do not mount vertically. Do not hang-
mount
Wiring Use minimum gauge 14 AWG wire (not supplied) to connect the UPS
Main and GND terminals to the vehicle battery. For details, see the Wiring
Diagram on page 2.
Route the wiring away from sharp edges that might damage the insulation.
Installation Requirements
Fold Here
Wiring Diagram
Vehicle Battery
(12V DC nominal)
IGNITION
To vehicle
switched 12V
Black
Red
Yellow
Black
Red
Power switch Fuse holder
Setpoints
The UPS ships congured with the following setpoints:
Setpoint Voltage Description
Main On 12.5V When the voltage from the vehicle battery is greater than 12.5V,
the controller uses vehicle battery power for the recorder.
Main Off 11.8V When the voltage from the vehicle battery is less than 11.8V, the
controller switches the recorder from vehicle battery power to
UPS battery power.
Charge On 12.7V When vehicle battery power is above 12.7V, the controller sends
a trickle charge to the UPS battery. This charging operation is
independent of the other functions.
Charge Off 12.1V The controller stops charging the UPS battery when voltage
from the vehicle battery falls below 12.1V.
Aux On*12.6V If voltage from the vehicle battery is below 11.8V (Main Off), the
unit switches the recorder to the auxiliary battery, independent
of the value of Aux On. Once the auxiliary battery has dropped
below 10.0V (Aux Off), it stays off until the vehicle battery
power is above 12.5V (Main On). The Aux On feature powers the
recorder if the auxiliary battery is replaced or charged.
Aux Off*10.0V When the voltage at the Aux Input is less than 10.0V, the Aux
Input is disconnected. It is not reconnected until the voltage
at the Aux Input is greater than 12.6V (Aux On). If the vehicle
battery voltage comes back, the controller switches the recorder
power to the vehicle battery and resets the Aux On/Off state.
* Auxiliary battery is optional.
LED Indicators
When illuminated, LEDs indicate which source (vehicle battery or UPS internal battery) is powering
the load, as follows:
• Main - vehicle battery is powering the recorder
• Aux - UPS internal battery is powering the recorder
LED indicators
Minimum gauge: 14 AWG
Minimum gauge: 14 AWG
 Wire the main power fuse/holder from
the recorder power harness kit between
the vehicle battery and the UPS
UPS
Recorder
Installing the UPS
1. Choose a mounting location according to the Installation Requirements on page 1.
2. Use 4 self-tapping screws (not supplied) to secure the UPS to the mounting surface.
3. Wire the UPS to the vehicle battery and the recorder as shown in the Wiring Diagram.
4. Remove the plastic fuse cover by snapping it off its base.
a. Insert the supplied 15A fuse into the fuse holder.
b. Snap the fuse cover back into place.
5. Power on the device.

Popular UPS manuals by other brands

Huawei PDU8000-0630ACV4-SCA108 user manual

Huawei

Huawei PDU8000-0630ACV4-SCA108 user manual

OPTI-UPS DS-C33 II Series user manual

OPTI-UPS

OPTI-UPS DS-C33 II Series user manual

HPE R1500 user guide

HPE

HPE R1500 user guide

Tescom 400 VA user manual

Tescom

Tescom 400 VA user manual

ECONOLITE ZincBlue2 UPS 1000W user manual

ECONOLITE

ECONOLITE ZincBlue2 UPS 1000W user manual

Georator Triathlon III T3UPS-13-15K instruction manual

Georator

Georator Triathlon III T3UPS-13-15K instruction manual

GE LP 33U Series operating manual

GE

GE LP 33U Series operating manual

Sola HD S4KC Series user manual

Sola HD

Sola HD S4KC Series user manual

ReDeal AP160N user manual

ReDeal

ReDeal AP160N user manual

CyberPower Value1200ELCD user manual

CyberPower

CyberPower Value1200ELCD user manual

Eaton 40 kVA User and installation guide

Eaton

Eaton 40 kVA User and installation guide

Alpha Outback Energy Continuity 6K user manual

Alpha Outback Energy

Alpha Outback Energy Continuity 6K user manual

Phasak PH 9530 user manual

Phasak

Phasak PH 9530 user manual

MGE UPS Systems Comet EXtreme CLA installation manual

MGE UPS Systems

MGE UPS Systems Comet EXtreme CLA installation manual

Online USV ZINTO A 800 user manual

Online USV

Online USV ZINTO A 800 user manual

Huawei UPS5000-A-300K-STT user manual

Huawei

Huawei UPS5000-A-300K-STT user manual

Fideltronik Inigo LUPUS 600N user manual

Fideltronik Inigo

Fideltronik Inigo LUPUS 600N user manual

CyberPower Utility Tower Plus Series UPS UP425UIT user manual

CyberPower

CyberPower Utility Tower Plus Series UPS UP425UIT user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.