Serai RX/90 User manual

CH1
ERA IS
Gate Openers Division
RX/90
38.90
TWO-CHANNEL, VARIABLE ROLLING CODE RECEIVER FOR BURGLAR ALARM SISTEMS
1
Radio 433.92MHz two-channel "variable code" or "rolling code" receiver, whose code changes at every transmission, and therefore offers a high safety
level, suitable to memorize up to 33TX/92 remote controls.
The board must be connected to SERAI burglar alarm control units of the Fenice range (see connection diagram), and has two available channels:
- channel 1 is available as open collector output, in CH1 terminal board, which closes at "-" when the channel is activated upon receiving a command,
- channel 2 is available as clean exchange max. [email protected], in NC/C/NA terminal board, with C in contact with NC at rest, and for which C is in contact
with NAwhen the channel is activated upon receiving a command.
Both channels can have monostable behaviour (only active during command reception) or bistable (status changes from inactive to active and vice-versa
at each command received); this behaviour is set with the dip-switches on the board. In case of bistable behaviour, in case of power failure the current
status of the channel is memorised and restored when the power is on again.
NEGATIVE SUPPLY
TERMINAL FOR CONNECTING
OPTIONAL OG/50 ANTENNA:
CONNECT THE BRAID TO GND
POSITIVE SUPPLY
CHANNEL 1 OPEN COLLECTOR OUTPUT
CHANNEL 2
MONOSTABLE:
(PULSE)
CHANNEL 1
MONOSTABLE
(PULSE)
ANTENNA CONNECTION
BRAID CONNECTION
CHANNEL 2
BISTABLE
(WITH MEMORY)
CHANNEL 1
BISTABLE
(WITH MEMORY)
CHANNEL 1 BUTTON (P1)
CHANNEL 2 BUTTON (P2)
dip1dip2
CHANNEL 2 LED (L2)
CHANNEL 1 LED (L1)
CHANNEL 2 RELAY NA CONTACT
CHANNEL 2 COMMON RELAY
CHANNEL 2 RELAY NC CONTACT
NA
NC
C
RX/90 FENICE RANGE
AN/8 OR AN/40 BURGLAR CONTROL UNIT
CH1
ATTENTION!
Connect the antenna supplied to the antenna terminal and perform a range
test by using a registered TX/92 remote control. Should coverage prove to
be insufficient, replace the standard antenna with an OG/50 optional
external antenna.
!
ANTENNA
Id2: DEFAULT FUNCTION = ON/OFF PROGRAMME A
Id3: DEFAULT FUNCTION = ON/OFF PROGRAMME B
CHANNEL 2
ATTENTION!
Before proceeding with remote control programming, disconnect the
antenna to prevent the RX/90 receiver from acquiring in this phase any
other SERAI rolling code remotes that might be activated in the vicinity.
Re-connect the antenna upon completing the procedure.
!
CONNECTING THE RX/90 RECEIVER TO FENICE BURGLAR ALARM CONTROL
Set PULSE behaviour for
both channels (dip1 and dip2
ON)
Program button 1 of TX/92 on channel 1 of RX/90, and button 2 on channel 2
(see below for the self-learning procedure). According to the diagram shown in
the figure, pressing button 1 activates input ID2 and the function programmed for
it on the control unit; similarly, pressing button 2 activates input ID3. Default
functions for ID2 and ID3 are "on/off programme A" and "on/off programme B"
respectively. Each function can be modified from the control unit menu as
needed, for example: "off system", "activate output x", "special", etc..
Id1: DEFAULT FUNCTION = ANTI-TAMPERING

TECHNICAL DATA
Installation is to be performed in the complete absence of any
voltage.
Power supply voltage: .....................................................................10.8 ÷ 13.8Vdc
Maximum consumption: ....................................................................47mA@12Vdc
Radiofrequency: ....................................................................................433.92MHz
Type of transmission:...................................................... variable code (rolling code)
Reception distance in free space:...........................100m with wire antenna supplied
............................................................................200m with optional OG/50 antenna
Channel 1 output: ...............................................................................open collector
Maximum number of different storable remotes:....................................................33
Wiring: ............................................................................use 0.5sqmm section wires
Maximum dimensions (L x H x P):......................................................50 x 70 x 20mm
Weight: ...............................................................................................................35g
Operating temperature:..........................................................................-10 ÷ +40°C
Storage temperature:.............................................................................-20 ÷ +60°C
Maximum relative humidity: ................................................95% without condensate
Protection rating IP: ..............................................................................................00
RX/90 may be inserted in the shell of the Fenice control unit or installed outside, in
which case it should be inserted in a non metallic case that affords adequate
protection.
No particular maintenance is required.
PRODUCT CATEGORYAND INTENDED USE
DIRECTIVES
GENERIC STANDARDS
SPECIFIC PRODUCT STANDARDS
It is the installer's responsibility to comply with all the recommendations contained in this
instruction manual, as wellas with standards and laws relevant to the plant to be installed, even if
not specified herein.
Electronic, non-automatic device, for use in residential, commercial and light industrial settings,
designed to receive a control signal in radio frequency, implemented by means of open collector or relay
output. The intended use is exclusively in conjunction with SERAI burglar alarm control units of the
FENICE range.
Low voltage Directive (LVD):..................................................................................................2006/95/EC
Electromagnetic compatibility Directive (EMC): ...................................................................2004/108/EC
Directive on radio and telecommunications terminal equipment (R&TTE): ...............................1999/5/EC
Directive on Restriction of Hazardous Substances (RoHS):...................................................2011/65/UE
European electrical safety standard:.....................................................................................EN 60335-1
European EMC standard - immunity: ..................................................................................EN 61000-6-1
European EMC standard - emissions:.................................................................................EN 61000-6-3
European Standards relative to R&TTE (SRD): .......................EN 300220-1+EN301489-1+EN301489-3
Non-automatic control devices forfixed electricalinstallation.................................................EN 60669-1
2nd CHANNEL
1st CHANNEL
With a tool that affords double insulation, press the
button of the selected channel for approximately 1s.
The corresponding yellow LED lights up steadily.
Press the remote control button which you wish to control that channel with. The receiver's
yellow LED flashes briefly and then stays on steadily: remote saved.
It is not necessary to perform self-learning of the clones of an already programmed transmitter,
since they are automatically programmed simply any time they are used, without accessing the
receiver.
PRESS
FOR 1s
ATTENTION!
If storing does not occur when the transmitter button is pressed, then the
transmitter button you have pressed has already been saved for that
particular channel, the transmitter is faulty or the battery is down.
ATTENTION!
Do not keep the button pressed for 5s or longer, otherwise all previously programmed codes
will be deleted.
PREMERE
BREVEMENTE
SELF LEARNING OF TX/92 REMOTE CONTROLS WITH RX/90 RECEIVER
RX/90 RECEIVER
1 2
!
34Repeat sequence
from point 2 to store
other remote controls.
To exit programming press the
receiver button briefly or wait about 2
minutes. The yellow LED should go
out.
!
To cancel programming of one of the two channels, keep the button of
the selected channel pressed for at least 5s until the relevant yellow LED
starts flashing quickly (cancellation in progress). Release the button and
wait for the LED to stay on steadily: the greater the number of remotes
stored, the longer it takes for the cancellation.
Upon completing cancellation, the LED stays on steadily, in self-learning
mode for the selected channel. Proceed from point 2 of the above
procedure.
LIGHT ON
PRESS FOR
AT LEAST 5s
FLASHING LIGHT
ATTENTION!
This procedure cancels all programmed transmitters for the selected channel only. If necessary repeat it for the other channel. In
order to re-program transmitters in relation to the deleted channel, the self-learning procedure must be performed again.
!
RX/90 RECEIVER
LUCE SPENTALUCE ACCESA
2nd CHANNEL
1st CHANNEL
CANCELLATION OF ALL REMOTE CONTROLS ASSOCIATED TO A CHANNEL
CE DECLARATION OF CONFORMITY
SERAI srl hereby declares that the RX/90 was designed and manufactured in full compliance with the above mentioned directives and standards.product
2011/65/UE DIRECTIVE ABOUT THE RESTRICTION OF THE USE OF CERTAIN HAZARDOUS SUBSTANCES IN ELECTRICALAND ELECTRONIC EQUIPMENT (RoHS)
2012/19/UE DIRECTIVEABOUT THE WASTE OF ELECTRICALAND ELECTRONIC EQUIPMENT (WEEE)
This device was manufactured according to the restrictions set by the RoHS directive. To protect the environment: when no longer needed, the device must not be disposed of as mixed municipal
waste. Take it to an appropriate WEEE (Waste of Electric and Electronic Equipment) waste collection facility.
MADE IN ITALY
VIA ENRICO FERMI, 22
35020 LEGNARO - PADOVA
ITALY
+39 049 79 08 58
+39 049 88 30 529
www.serai.com
ELETTRONICA PADOVA
WARRANTY CONDITIONS
The company reserves the right to make any modification without prior notice. The conventional SERAI product warranty is valid 24 months following the issuance of the fiscal document attesting to its purchase. Services
covered by the warranty are provided at the company's facilities in Legnaro (PD - ITALY) or at any one of the company's authorized Service Centres. The relative shipping and transport costs are at the Customer's
expense. For TechnicalAssistance call: +39.049.790.858, Monday to Friday 8:30 to 12:30 and 14:00 to 18:00. The warranty shall be retained void in the event of any tampering with the product or in the event that the label
specifying the product's production batch has been broken or removed.
Other Serai Receiver manuals