In the case of solar flares arc or when the flame will be green or arc will be heard any unusual noise, immediately turn off the machine and check the
condition of wearing parts. Cutting can be interrupted by releasing the holder or by the sudden lifting the handle on the material. After releasing the
button on the handle will immediately extinguish the arc, and after a few seconds off the flow of compressed air. The delay in turn off the flow of
compressed air has to cool the heated components of the handle.
11. Before calling service,
In the event of malfunction of the unit, before sending the cutting for service, check the list of basic failure
and try to remove them yourself.
Repair work may only be carried out after removing the plug from the wall socket.
Warning! The device is not sealed, and the user can remove the casing cutter to remove fine failure.
Symptom s Cause Procedure
No power, signal failure or faulty
operation of the unit
No connection or loose in the pole inside the unit Check and correct the connection of all ll of the poles
inside the unit
After connecting the power supply LED
signaling is not St. IECI
No power supply Check fuses on white a network connection to
check whether there is voltage on the network
After connecting the power supply LED
signaling is not St. IECI
The power switch is in the OFF position Toggle switch (7) in the ON position
LED signaling the power of St. IECI, the fan
is not working, no power in yjściowego.
The supply voltage is unstable and turns on the
overvoltage protection
Turn off the unit for 2-3 minutes and reconnect
Short-term inclusion and yłączenie switch may
have been activated Overvoltage
Turn off the unit for 2-3 minutes and reconnect
Not to bow strikes None of the competent contact wire clamp mass Correct ll of mass contact terminal
Faulty switch in the handle Plasma white replace switch
Wrong OMPETENT connecting the handle
to the plasma unit
Check the condition of the electrical connections grips
Gripping, check that the pins in the socket are not
yłamane or jam
St. IECI LED overheating The device has been overheated. Wait a few minutes until the LED goes off and
continue cutting.
The fan is not working The fan was blocked folded cover Straighten fan cover
Unsatisfactory quality of cut The poor quality of the materials and parts
supplies
Replace consumables
Pow ietrze in ypływa with inappropriate intensity Check the air supply hose, correct ll of the connection
hose with fittings and quick status check air compressor
12. MANUAL OPERATION AND PARTS LIST OF OPERATING
Operation of CUTTER 90 CUTTER 110 should take place in an atmosphere free of corrosive components and dusty. Do not place the device in dusty,
near the working grinders, etc. Dust and pollution control boards metallic filings, wires and connections inside the unit may cause an electrical short, and
consequently damage to the radiator.
Avoid use in environments with high humidity, especially in situations of occurrence of dew on the metal parts.
If there is dew on the metal parts, for example. After entering the cold equipment into a warm room, wait until the dew disappears. It is recommended
that in the case of operating the cutter on the open-air place it under a roof to protect against adverse weather conditions.
Device CUTTER 90 CUTTER 110 should be operated under the following conditions:
-changes in the effective value of the supply voltage is not greater than 10%
- ambient temperature of from -10 ° C to + 40 ° C
- Atmospheric pressure 860 to 1060 hPa