Shuang Ri SR501 User manual

SR501
Please read the manual carefully before operation!

SR501 EN Operation Manual
- 1 -
Contents
1. Safety information .......................................................................................3
1.1 Installation and commissioning.....................................................................3
1.2 Liability waiver...............................................................................................3
1.3 Signal description..........................................................................................4
2. Installation.......................................................................................................4
2.1 Mounting controller .......................................................................................4
2.2 Power connection .........................................................................................5
2.3 Terminal port connection...............................................................................6
2.4 Advice regarding the installation of temperature sensors...........................10
2.5 Installation of solenoid valve.......................................................................10
2.6 Installation of sensor of temperature and water level.................................11
2.7 Bottom installation of sensor of temperature and water level.....................12
3. System diagram ........................................................................................13
4. Functions operation ......................................................................................13
4.1 Signals on display and function code .........................................................14
4.2 Button description.......................................................................................15
4.3 Menu structure............................................................................................17
4.4 Menu description.........................................................................................17
5. Main functions setup (for users) ...................................................................20
5.1 Time setting.................................................................................................20
5.2 Timing filling and heating with three time-sections.....................................20
5.3 Temperature controlled water filling function ..............................................23
6. Additional functions setting (for professionals) .............................................23
6.1 CTH Thermostat heating function...............................................................23
6.2 LWPR Low water pressure .........................................................................25
6.3 CWL constant water level filling function (preset 100% water level of tank)
..........................................................................................................................26
6.4 PUMP water filling pump.............................................................................27
6.5 TCYC Setting the temperature / flow for DHW pump running within three

SR501 EN Operation Manual
- 2 -
time-sections.....................................................................................................27
6.6 AH Automatic thermostat function...............................................................33
6.7 OTF Timer function .....................................................................................35
6.8 TKPR Tank high temperature protection function.......................................36
6.9 CFR Tank anti-freezing protection ..............................................................37
6.10 LWS Preset the water level of water filling when tank is lack of water.....38
6.11 LWSD delay time of water filling when tank is lack-of water.....................38
6.12 OTDI Thermal disinfection........................................................................38
6.13 UNIT Celsius degree and Fahrenheit unit switch .....................................40
6.14 BEEP Beeper error warning .....................................................................40
7. Manual functions...........................................................................................40
7.1 Manual water filling.....................................................................................40
7.2 Compulsive water filling function ................................................................41
7.3 Manual heating ...........................................................................................41
7.4 Manual DHW circulation .............................................................................42
7.5 Factory reset manually function..................................................................42
7.6 Sensor sensitivity adjustment.....................................................................42
8. Pipe anti-freezing protection function ...........................................................43
9. View the measuring value.............................................................................44
10. Protection function......................................................................................45
10.1 Overflow protection...................................................................................45
10.2 High temperature protection of collector tube...........................................45
10.3 Memory protection....................................................................................46
10.4 Screen protection......................................................................................46
10.5 Trouble protection.....................................................................................46
10.6 Error code description...............................................................................46
11. Quality Guarantee.......................................................................................47
12. Technical specification................................................................................47
13. Delivery list..................................................................................................47

SR501 EN Operation Manual
- 3 -
1. Safety information
We have carefully checked the text and pictures of this manual and provided the
best of our knowledge and ideas, however inevitable errors maybe exist. Please
note that we cannot guarantee that this manual is given in the integrity of image
and text, incorrect, incomplete and erroneous information and the resulting
damage we do not take responsibility.
1.1 Installation and commissioning
•When laying wires, please ensure that no damage occurs to any of the
constructional fire safety measures presented in the building.
•The controller must not be installed in rooms where easily inflammable gas
mixtures are presented or may occur.
•The permissible environmental conditions can’t be exceeded at the site of
installation.
•Before connecting the device, make sure that the energy supply matches
the specifications that controller requires.
•All devices connected to the controller must conform to the technical
specifications of the controller.
•All operations on an open controller are only to be conducted cleared from
the power supply. All safety regulations for working on the power supply
are valid.
•Connecting and /or all operations that require opening the collector (e.g.
changing the fuse) are only conducted by specialists.
1.2 Liability waiver
The manufacturer can’t monitor the compliance with these instructions or the
circumstances and methods used for installation, operation, utilization and
maintenance of this controller. Improper installation can cause damages to
material and person. This is the reason why we do not take over responsibility

SR501 EN Operation Manual
- 4 -
and liability for losses, damages or cost that might arise due to improper
installation, operation or wrong utilization and maintenance or that occurs in
some connection with the above-mentioned. Moreover, we do not take over
liability for patent infringements or infringements occurring with the use of this
controller on the third parties’ rights. The manufacturer reserves the right to put
changes to product, technical data or installation and operation instructions
without prior notice. As soon as it becomes evident that safe operation is no
longer possible (e.g. visible damage). Please immediately take the device out of
operation. Note: ensure that the device can’t be accidentally placed into
operation.
1.3 Signal description
Safety indication: Safety instructions in the text are marked with a
warning triangle. They indicate measures which can lead to injury of
person or safety risks.
Operation steps: small triangle “►”is used to indicate operation
step. Notes: Contains important information about operation or functions.
2. Installation
2.1 Mounting controller
Dimension of controller for electrical heater of 1500W:

SR501 EN Operation Manual
- 5 -
This controller can only be installed in the place having an adequate level of
protection.
►Choosing a suitable site
►Drilling the upper fixing hole ①
►Screwing on the screw
►Taking away the cover plate
►Hanging the bottom plate on the fixing hole ①
►Marking the position of bottom fixing hole ②
►Taking away the bottom plate
►Drilling the hole ②
►Re-hanging the bottom plate on screw ①
►Fixing bottom plate with screw ②
2.2 Power connection
Depending on the type of installation, the cables may enter the device
through the rear hole of the case ③or the base side hole of the case ④
Notes: the flexible wire must be fastened to the case using the strain-relief
clamps provided.

SR501 EN Operation Manual
- 6 -
③ ③ ④ ④
2.3 Terminal port connection
Before opening the terminal, please be sure to switch-off the power
and pay attention to the local electricity supply rules.
Terminal layout of controller for electrical heater of 1500W
•FU1: the fuse of controller, AC250V/2A
•Power input L, N:10A, for power connection, L: live wire, N: zero wire,
protective ground wire, please connect the ground reliably.
•Output ports
- HR: Electromagnetic relays, designed for on/off control of back-up
heating device, Max. Current: 10A ( @AC230V, for 1500W electrical
heater, @110VAC, for 750W electrical heater)
- P1: designed for anti-freezing heating cables, electromagnetic relay,
max. power is 500W.
- R1:designed for the solenoid valve of water filling, output power is
DC12V, wire connection is not positive and negative difference.

SR501 EN Operation Manual
- 7 -
- R2: designed for the electric tracing belt, electromagnetic relay,
maximum current is 2A.
With Auxiliary electrical heating, the user must install the leakage
protector himself.
•SR501 Remote display(optional accessory)
SR501(1500W)controller is designed to be able to connect to a remote
display, and on display, it is possible to set up
the functions like manually water filling,
manually trigger heating, manually trigger
DHW circulation, On/off device, checking
temperature and water level of the water tank
and so on.
Remote display connection to the controller:
Port 1: connect red wire (+12V)
Port 2: connect white wire (COM)
Port 3: connect black wire (GND)
Note:
1) The remote display interface is not configured on the standard SR501
controller, if need a remote display, then the controller needs to be
customized.
2) Remote display is not included in the standard parts of delivery, which
should be purchased separately.
3) The maximum length of connection wire between the remote display and
SR501 controller is not exceeded 45 m
Input ports
- Sensor of water temperature and water level of the water tank(B03):
Port 1: connect red wire (+12V)
Port 2: connect white wire (COM)
Port 3: connect black wire (GND)

SR501 EN Operation Manual
- 8 -
- T1: for NTC10K, B=3950, ≤135oC temperature sensor (PVC cable ≤105oC),
designed for DHW circulation TCYC or AH function (optional)
- T2: for NTC10K, B=3950, ≤135oC sensor (PVC cable ≤105oC), designed
for pipe anti-freezing function (optional)
Note: T1, T2 temperature sensors are not included in the standard parts of
delivery, which should be purchased separately.
Terminal layout of controller for electrical heater of 3000W
•Power input N, L:20A, for power connection, L: live wire, N: zero wire,
protective ground wire, please use 2mm²cable to connect the ground
reliably.

SR501 EN Operation Manual
- 9 -
•Output ports
- HR: Electromagnetic relays, designed for on/off control of back-up
heating device, Max. Current: 16A ( @AC230V, for 3000W electrical
heater, @110VAC, for 1500W electrical heater)
- P1: electromagnetic relay, max. power is 200W.
- R1:designed for the solenoid valve of water filling, output power is
DC12V, wire connection is not positive and negative difference.
- R2: electromagnetic relay, designed for the electric tracing belt,
maximum current is 2A.
- With Auxiliary electrical heating, the user must install the leakage
protector himself.
-
Input ports
- Sensor of water temperature and water level of the water tank(B03):
Port 1: connect red wire (+12V)
Port 2: connect white wire (COM)
Port 3: connect black wire (GND)
- T1: for NTC10K, B=3950, ≤135oC temperature sensor (PVC cable ≤105oC),
designed for DHW circulation TCYC or AH function (optional)
- T2: for NTC10K, B=3950, ≤135oC sensor (PVC cable ≤105oC), designed
for pipe anti-freezing function (optional)
Note:
1) SR501-3KW has no remote display function.
2) T1, T2 temperature sensors are not included in the standard parts of
delivery, which should be purchased separately.

SR501 EN Operation Manual
- 10 -
2.4 Advice regarding the installation of temperature sensors
T1, T2 sensor cables carry low voltage, and to avoid inductive effects, must
not be laid close to 230 Volt or 400 Volt cables (minimum separation of
100mm).
T1, T2 sensor cables may be extended to a maximum length of ca. 100
meter, when cable’s length is up to 50m, and then 0.75mm2cable should
be used. When cable’s length is up to 100m, and then 1.5mm2cables
should be used.
2.5 Installation of solenoid valve
Flushing pipe and cleaning pipe before mounting the solenoid valve
If water is provided by water tower, to avoid no water filling or water flow
rate is too low at solenoid valve, please select the solenoid valve which
pressure is matched to the hydraulic pressure got from water tower.
Check whether the required voltage labelled on the type plate of solenoid
valve is same to the voltage of power output of controller, check whether
the filter of solenoid valve is completed, whether the body of valve has no
damage. And during installation please pay attention to the water flow and
return of solenoid valve, side with filter is the water input, water flow
direction and arrow signal on the body of solenoid valve should be aligned
in same direction.
Solenoid valve should be
indoor installed at the place
where is easy for maintenance
or at the area where no more
connected loss happened. To
keep a long lifetime of solenoid
valve, please pay attention to
anti-frost, sun protection and prevent broken damage from freezing or
aging of body of solenoid valve.
It is prohibited to use a wrench worked on the coil wire and plastic parts, to
Coil wire,
upwards
installed
Water inlet
Filter
Water outlet

SR501 EN Operation Manual
- 11 -
ensure no damaged during installation and no torsion effect positioned on
the solenoid valve, it is not allowed to install valve compulsively when tow
connectors are not aligned.
Two-cores wire is used for connection with solenoid valve, if wire needs to
be lengthened, please select cable of 1.0mm2.
To easy clean the filter, water inlet pipe connected to the solenoid valve
should be a kind of soft pipe or pipe is easily dismounted.
Note: one-way check valve integrated into the solenoid valve, so no
one-way valve needs to be installed.
2.6 Installation of sensor of temperature and water level
Sensor of water temperature and water level is inserted into tank from the
overflow connector.
Fasten sensor with the mutter of
sensor.
3-cores wire of sensor connected to the input port of controller
- Port 1: connect red wire (+12V)
- Port 2: connect white wire (COM)
- Port 3: connect black wire (GND)
Note:
1).Depending on the way of difference installation, we provide three different
sensors, and the customer chooses one of them as needed. If the customer
does not specify anything, we will follow the factory default configuration.
a).”Side mounted sensor”
(factory default configuration) see
the picture 1

SR501 EN Operation Manual
- 12 -
b).”Top mounted sensor”
(need to be specified in order) see the
picture2
c).”Bottom mounted sensor”
(Need to be specified in order) refer the details of Paragraph 2.7
2). To avoid the measuring error or damage the sensor, sensor of
temperature and water level must not touch or close to the e-heater tube
2.7 Bottom installation of sensor of temperature and water level
There are 2 installation ways for positioning the sensor of temperature and
water level on the bottom part of tank: one way is inserting sensor from hole of
collector, the other is inserting sensor from bottom of tank. Diameter of
installation hole is 47mm.
Sensor installed on the bottom
collector tube hole
Sensor installed on the bottom of
tank

SR501 EN Operation Manual
- 13 -
3. System diagram
Note: this diagram is only for reference.
4. Functions operation
Before switching-on the power, please connect sensor of temperature and
water level, water filling solenoid valve to the input port of controller, connect
electrical heater to the output port of controller. And then switching-on power,
the controller runs an initialization phase for 5 seconds, then controller runs a
commissioning menu, it leads the user through the most important adjustment
channels needed for operating the system.

SR501 EN Operation Manual
- 14 -
4.1 Signals on display and function code
LCD display screen
Code
Description
Code/Signal Lighting
Code/Signal Blink
Constant
Temperature
Thermostat heating
Function is activated
Function is
running
OTDI
Thermal disinfection
function (check under
menu inquiry)
Countdown of
disinfection function
working (DDIS)
OTF
Timer(check under
menu inquiry)
Temperature
controlled pipe
heating belt
Function is activated
Function is
running
Time controlled pipe
heating belt
Function is activated
Function is
running
Timing heating
function
Function is activated
Function is
running
Temperature
controlled DHW within
3 time - sections
Function is activated
Function is
running
Water flow controlled
DHW within 3 time -
sections
Function is activated
Function is
running
Automatic
thermostat
Function is activated
Function is
running
Anti-freezing
protection(check
under menu inquiry)
Function is activated
Function is
running
Manual function
Fault alarm of sensor of temperature and water level

SR501 EN Operation Manual
- 15 -
4.2 Button description
Buttons layout on the controller
•Button description
- “Water Loading”button: water filling manually (detailed see section 7.1)
- “HEAT” button: heating manually (detailed see section 7.3)
- “SET” button: access the menu or activate the set value
- “ESC”button: confirm the setting value and ESC or return to the
previous menu
- “▲” button: increase adjustable value or upwards menu
- “▼" button: decrease adjustable value or downwards menu
- Press “▲” for 3 seconds: switch on/off the pipe anti-freezing function (see
detailed in the section 6.9)
- Press “▼” for 3 seconds: switch on/off manual DHW circulation function
(at the case function TCYC DHW circulation function is enabled) (see
detailed in section 6.4)
- Press “SET” button for 3 seconds: to access addition main menu
- Press “ESC” button for 3 seconds: to check the on/off status of auxiliary
functions (includes functions like: low water pressure function,
disinfection function, anti-freezing function, timer function, tank high
temperature protection function)
•Main menu operation steps
►1. Press “SET” button to access the menu of timer, timing water filling and
timing heating function
2. Press “SET” button for 3 seconds to access main menu of auxiliary

SR501 EN Operation Manual
- 16 -
functions
►Press “▲▼” to adjust the main menu
►Press “SET” to access submenu
•Submenu operation steps
►Press “SET” to access submenu
►Press “SET” again to the adjustable item, press “▲▼” to select “ON” to
activate the option, or select “OFF” to deactivate this option
►Press “SET” or “ESC” to confirm the adjust
►Press “▲”to access the next submenu
►Press “SET” to set the adjustable value
►Press “▲▼” to adjust value
►Press “SET” or “ESC” to confirm the adjust
Note:after accessing the adjust channel, if no any button is pressed for 3
minutes, then display returns to the main interface.

SR501 EN Operation Manual
- 17 -
4.3 Menu structure
Controlled can be detailed set through the submenu, please understand
and get familiar with the submenu.
4.4 Menu description
Main functions menu (for users)
Code
(Main menu)
Code
(Submenu)
Default value
Description
Clock
Clock
Time Water
Timing water filling
Time Water 1
03:00 / 50%
Time and water level of the 1st time water
filling
Time Water 2
09:00 /100%
Time and water level of the 2nd time water
filling
Time Water 3
16:00 / 100%
Time and water level of the 3rd time water
filling
Time Heat
Timing heating
Time Heat 1
04:00 / 50℃
Time and temperature of the1st time water
heating
Time Heat 2
10:00 / 0℃
Time and water level of the 2nd time water
heating
Time Heat 3
17:00 / 60℃
Time and water level of the 3rd time water
heating

SR501 EN Operation Manual
- 18 -
Auxiliary functions menu (for professionals)
Code
(Main menu)
Code
(Submenu)
Default value
Description
CTH
Thermostat heating function
tH1O
00:00/55℃
Switch-on time and temperature of the 1st
time section of CTH function
tH1F
23:59/60℃
Switch-off time and temperature of the 1st
time section of CTH function
tH2O
00:00/55℃
Switch-on time and temperature of the 2nd
time section of CTH function
tH2F
00:00/60℃
Switch-off time and temperature of the 2nd
time section of CTH function
tH3O
00:00/55℃
Switch-on time and temperature of the 3rd
time section of CTH function
tH3F
00:00/60℃
Switch-off time and temperature of the3rd
time section of CTH function
LWPR
ON
Low water level protection function of water
filling
CWL
OFF
Constant water level: tank is full, water level
100%
CWSL
80%
Water level of filling
It is able to set as 0%,20%,50%,80%。,
when tank water level drops to the set water
level, water will be filled automatically to
100% water level.
PUMP
OFF
On/off of water filling pump (output port is
P1), note: when water filling pump(p1 voltage
AC220V) function is enable, P1 and solenoid
valve will be on/off synchronously.
TCYC
OFF
DHW circulation controlled by temperature
and water flow in three-time sections (output
port: P1)
MODE
FS/tEP
Control mode selection between water flow
of DHW circulation control or temperature
control
STAT
ON
Trigger-on condition of temperature
controlled DHW circulation
CYCO
37 ℃/03
minute
Switch-on temperature/time
CYCF
42 ℃/10
minute
Switch-off temperature/time
tC1O
00:00
Switch-on time of the 1st time section
tC1F
23:59
Switch-off time of the 1st time section
tC2O
00:00
Switch-on time of the 2nd time section
tC2F
00:00
Switch-off time of the 2nd time section
tC3O
00:00
Switch-on time of the 3rd time section
tC3F
00:00
Switch-off time of the 3rd time section

SR501 EN Operation Manual
- 19 -
AH
OFF
Automatic thermostat function (output port:
P1)
AHS
tst / S1
Sensor selection for automatic thermostat
function (tst indicates tank temperature, S1
indicates T1 temperature sensor)
AHO
40℃
Switch-on temperature
AHF
45℃
Switch-off temperature
tA1O
00:00
Switch-on time of the 1st time section
tA1F
23:00
Switch-off time of the 1st time section
tA2O
00:00
Switch-on time of the 2nd time section
tA2F
00:00
Switch-off time of the 2nd time section
tA3O
00:00
Switch-on time of the 3rd time section
tA3F
00:00
Switch-off time of the 3rd time section
OTF
OFF
Timer function (output port: P1)
t 1O
00:00
Switch-on time of the 1st time section
t 1F
00:00
Switch-off time of the 1st time section
t 2O
00:00
Switch-on time of the 2nd time section
t 2F
00:00
Switch-off time of the 2nd time section
t 3O
00:00
Switch-on time of the 3rd time section
t 3F
00:00
Switch-off time of the 3rd time section
TKPR
ON
Tank high temperature protection
SMX
80℃
Temperature of water filling at tank high
temperature protection function
CFR
ON
Anti-freezing protection
LWS
LWSL
50%
Water level of water filling at lack of water
protection function
LWSD
30minute
Water filling run-on time at lack of water
protection function
OTDI
OFF
High temperature disinfection function
TDIS
70℃
Temperature for disinfection
UNIT
℃
Temperature unit selection ℃/℉
BEEP
ON
Fault alarm
Note: functions TCYC, AH, OTF, PUMP is allocated with a same output
port P1, so only one can be activated form 4 functions, then the others will be off
Table of contents
Popular Water Heater manuals by other brands

RED-RING
RED-RING POWERSTREAM RPS95 Installation and user guide

Takagi
Takagi T-K1 Installation manual and owner's guide

ATI Technologies
ATI Technologies SX160 manual installation, use and maintenance

Kenmore
Kenmore 153.313340 owner's manual

Froling
Froling TURBOMAT TM 150 operating instructions

Kaisai
Kaisai KHP-2.4/D270 Installation and service manual

Atlantic
Atlantic CHAUFFEO Installation and operating manual

Graf
Graf CARAT XXL Series Installation/assembly and maintenance instructions

Thermo Dynamics
Thermo Dynamics ELITE TDCH user manual

Noritz
Noritz NRCP111-DV owner's guide

Shield
Shield SNR126-065 Installation & service manual

Bosch
Bosch 520PN Applications manual