Siedle novotechnik MUP-410 User manual

2 Connection
1 Description
12 1413
EXT. 1
EXT. 2
+
-
-
+
3 4 5
1 2
+
Power supply
V
Analog
output
mA
79
8
OMNI
0,05…2,5 mm2
3 0 …12 A WG
8
0.32
Ø 3,5 mm
Ø 0.14 in
1,5 Nm
13.2 lb-in
MINI-TECHDOK - MUP-410_AO - 2023.1.3 - en
www.novotechnik.de 1 / 4
fr it
Digital DIN rail mounted signal
converter
INPUT FOR POTENTIOMETERS
• Input for potentiometers
• Analog output
• Up to 7 200 measurements/s
• Quick conguration by DIP switch
• PC congurable via USB port
• Galvanic isolation 2.5 kVAC
• Simple instalation to DIN rail
csesen fr
MUP-410
Lo
Hi
1
2
4
3
1
USB
micro
1 2 3 4 5 7 8 9
Power
IN 1 OUT 1
Input
Pot.
mA
V
OMNI
LED Indication
Hi Lo Status
Device is running
Device functionality is limited, powered via USB
This device has a Delayed Start option
Error: device is out of order
Tare function is activated
Error: of input (> ±110% of range) or of sensor
[ERR.1, 3]
Error: AO loop open [ERR.10]
Error: setting / calibration [ERR.34-36]
Serious error (Safe mode) [ERR.50]
Button function is blocked
Simulation mode is activated
Legend
1
Connectors
2
Control button
3
RGB Status LED
Note
Contactors, high power electric motors, frequency drives and other power devices
should not be in a close proximity of the meter. Input signal leads (measured value)
should be seperated from all power lines and power devices. Even though the device
has been designed and tested according to standards for industrial environment, we
strongly advise to adhere to the above presented rules.
DANGER WARNING
HAZARD OF ELECTRICAL SHOCK
- Disconnect all power and other supply lines before servicing equipment
EQUIPMENT OPERATION HAZARD
- Do not use this product in safety critical system
- Do not disassemble, repair or modify this product
- Do not operate beyond the recommended operating environment
Failure to follow this instruction may result in death or serious injury. Failure to follow these instructions may result in death, serious injury, or equipment damage.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Novotechnik Messwertaufnehmer OHG for any consequences arising out of the use of this device.
de

3
Device setting
Input wiring diagram
Analog output
0…5 /20 mA
4…20 mA
3 - 4
0…2 /5/10 V
±10 V
3 - 5
Input - Potentiometers
iControl of external inputs is via contact
(voltage-free)
Analog current output [mA]
Lo
Hi
1 2 3 4 5 7 8 9
Lo
Hi
1 2 3 4 5
mA
7 8 9
+−
Analog Voltage Output [V]
Lo
Hi
1 2 3 4 5
V
7 8 9
+−
Input - External inputs
12 13 14
Ext. 1
Ext. 2
Output wiring diagram
Analog input range setting, TEACH-IN
1. by a short press of the Lo button enter the configuration mode - LED Hi yellow and LED Lo turquoise
2. connect the signal of the desired value for the minimum of the range RNG.MIN (for example 5 mA)
3. by a long press (>2s) of the Lo button this value is se - LED Hi yellow, LED Lo purple
4. connect the signal of the desired value for the maximum of the range RNG.MAX.(for example 19,5 mA)
5. by a long press (>2s) of the Lo button this value is set - LED Hi yellow, LED Lo green
6. by a short press of the Lo button return to the standard working mode - LED Hi green
DIP switch
For a quick set up you can use the DIP switch
Tare settings
1. by a short press of the Hi button enter configuration of Tare - LED Hi white and LED Lo turquoise
2. by a long press (>2s) of the Hi button set the current value of Tare - LED Hi white, LED Lo green
3. by a short press of the Hi button return to the standard working mode with active Tare - LED Hi green, LED Lo white
i A short press at any time during the calibration will
end the calibration without saving.After one minute
of inactivity, the calibration is terminated without
saving and both LEDs return to the basic state
i Setting of Analogue input TEACH-IN is active only
when DIP switches No. 1-2 are in the “0” position,
i.o. Setting via OMNI Link
Minimum range of Analog output for U/I inputs
signals is pre-set as unipolar,
i.e. "0 V/mA" or "4 mA".
If required, it is also possible to enter a negative
value of the maximum in the minimum, i.e. zero will
be in the middle of the selected range.
i
i In order to avoid possible unintended changes to
settings by accidentally pressing the Hi and Lo
buttons, these buttons can be disabled by conne-
cting terminals No. 12 and 14 of external inputs. The
buttons can also be deactivated in the device menu
using SW OMNI Link.
MINI-TECHDOK - MUP-410_AO - 2023.1.3 - en
www.novotechnik.de 2 / 4
1 2 Input
Setting via OMNI Link
•Potentiometer (default)
3 4 5 Rate [measurements/s]
50
•300
•400
• • 400 - FFT
•1200
• • 2400
• • 4800
• • • 7200 (default)
6 7 8 Output - range
0…2 V
•0…5 V
•0…10 V
• • ±10 V
•0…5 mA
• • 0…20 mA
• • 4…20 mA (default)
• • • Er. 4…20 mA

INPUT
No. of inputs 1
Setting 24-bit ΔΣADC with PGA
The range is selectable either by DIP
switch or by OM Link free SW from PC
Power 2.5 VDC/5 mA,
potentiometer resistance > 500 Ω
External input
No. of inputs 2, on contact
Function OFF No function assigned
TARE Activation of Tare
CL.TAR. Reset of Tare
HOLD Measurement paused
SAMPLE Take a one-off measurement
HLD.MIN Value of minimum *
HLD.MAX Value of maximum *
HLD.M-M Value of MAX-MIN*
KEY.LCK. Device buttons blocked
*The value is calculated from the period starting with the previous external
input activation.
INSTRUMENT SPECIFICATION
TC 15 ppm/°C
Accuracy ±0.01 % of FS
Rate 100…7 200 measurements/s
speed of 400 meas./s is with FFT
signal ltering
Latency < 580 µs
Overload 10x (t < 30 ms), 2x
Functions Teach-in, Tare, Math. functions,
Simulation (only via OMNI Link)
Digital lters exponentia l / oatin g / arithmetic aver-
age, rouding (only via OMNI Link)
Math functions polynomial / inverse polynomial/ loga-
rithm /exponential / power / root (only
via OMNI Link)
Linearization linear interpolation in 100 points
(only via OMNI Link)
OMNI Link On request: company communica-
tion interface for operation, setting and
update of instrument (microUSB).
Watch-dog reset after 500 ms
Calibration at 25°C and 40 % r.h.
ANALOG OUTPUT
No. of outputs 1
Type isolated, adjustable with 16-bit DAC,
output type and range is selectable
TC 15 ppm/°C
Non-linearity 0.024 % of FS
Accuracy ±0.02 % of FS
±0.03 % of FS 0…5 V
±0.05 % of FS 0…2 V / 0…5 mA
Rate response to change of value < 160 µs
Output signals 0…2/5/10 V, ±10 V, resistive load ≥ 1 kΩ
0…5/20 mA/4…20 mA, comp. < 500 Ω/12 V
Indication of broken current loop
Indication of error message (output < 3.2 mA)
POWER SUPPLY
Power 10…30 VDC/24 VAC, ±10 %, 2.5 VA,
PF ≥ 0.4,
ISTP< 40 A/1 ms, isolated
Fuse inside (T500 mA)
MECHANIC PROPERTIES
Material PA66, incombustible UL 94 V-0, green
Dimensions 25 x 79 x 90.5 mm (w x h x d)
Installation to DIN rail 35 mm wide
OPERATING CONDITIONS
Connection connector terminal blocks,
section < 1.5 mm2
Stabilization
period
within 5 minutes after switch-on
Working temp. -20°…60°C
Storage temp. -20°…8 5°C
Working
humidity
< 95 % r.h., non condensing
Protection IP20
Construction safety class I
El. safety EN 61010-1, A2
Dielectric
strength
2.5 kVAC for 1 min. between power
supply and signal input
2.5 kVAC for 1 min. between signal
input and outputs
Insulation
resistance*
for pollution degree II, measurement cat. III
power supply > 300 V (PI), 255 V (DI)
Input/outputs > 300 V (PI)
EMC EN 61326-1 (Industrial area)
RoHS EN IEC 63000 : 2018
Seismic
qualication
IEC/IEEE 60980-344 Edition 1.0, 2020, par. 6, 9
Mechanical
resistance
EN 60068-2-6 ed. 2:2008
* PI - Primary insulation, DI - Double insulation
5Technical data
4 Instrument dimensions and installation
Side view
mm
inch
Front view
25
0.98
3.11
Top view
3.54
3.56
79
Lo
Hi
2
90,5
90
1 2 3 4 5 6 7 8
ON
Installation to DIN rail of 35 mm width
2.91
74
MINI-TECHDOK - MUP-410_AO - 2023.1.3 - en
4 / 4www.novotechnik.de

Novotechnik Messwertaufnehmer OHG
Horbstrasse 12, 73760 Ostldern,
Germany
+49 711 4489-250 support@novotechnik.de
Measuring instruments of the MUP-410 series conform to the European regulation 2014/30/EU, 2014/35/EU and 2011/65/EU, 2015/863/EU.
This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations.
As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this publication.
MINI-TECHDOK - MUP-410_AO - 2023.1.3 - en
4 / 4www.novotechnik.de