Siklu EtherHaul-1200F User manual

© ALL RIGHTS RESERVED TO SIKLU COMMUNICATION LTD.
EtherHaul-1200F™
Gigabit Ethernet Wireless Solution
Installation Manual
EH1200F-INST-04, Issue 3
February 2015

EH-1200F Installation Manual
Page 2
Trademarks
Siklu, the Siklu logo, and EtherHaul are all trademarks of Siklu Communication Ltd.
All other product names and trademarks mentioned in this document are trademarks or
registered trademarks of their respective companies.
Copyrights
Copyright © 2014 Siklu Communication Ltd. All rights reserved.
No part of this publication may be reproduced or distributed in any f orm or by any
means, or stored in a database or retrieval system, without the prior written consent of
Siklu.
Disclaimers
The information contained in this document is subject to change without notice.
Siklu assumes no responsibility for any errors that may appear. Siklu makes no
warranties, expressed or implied, by operation of law or otherwise, relating to this
document, the products or the computer software programs described herein.
This document was originally written in English. Please refer to the English language
version for a full and accurate description of all products and services described herein.

EH-1200F Installation Manual
Page 3
Safety and Regulatory Notices
The following are mandatory notices for installation and operation of EtherHaul
Wireless Backhaul Link. Indications appearing here are required by the designated
government and regulatory agencies for purposes of safety and compliance.
General
Do not install or operate this System in the presence of flammable gases or fumes.
Operating any electrical instrument in such an environment is a safety hazard.
European Commission
This product has been designed to comply with CE markings in accordance with the
requirements of European Directive 1995/5/EC.
This product has been designed to comply with the requirements of European
Directives.
This equipment must be permanently earthed for protection and functional purposes.
To make a protective earth connection, use the grounding point located on the System
ODU using a minimum amount of 16AWG grounding cable or according to local
electrical code.
This apparatus is intended to be accessible only to authorized personnel. Failure to
prevent access by unauthorized personnel will invalidate any approval given to this
apparatus.
This product is in full compliance with the following standards:
RF EN 302 217-3 1.3.1
E-Band FCC part 101
EMC EN 301 489-4
Safety IEC 60950
Operation EN 300 019-1-4 Class 4.1E
Storage EN 300 019-1-1 Class 1.2
Transportation EN 300 019-1-2 Class 2.2
FCC/IC Regulatory Statements
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules and IC RSS standards. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful

EH-1200F Installation Manual
Page 4
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Note:
Changes or modifications to this equipment not expressly approved by Siklu LTD or
the party responsible for compliance could void the user's authority to operate the
equipment.
Caution:
Outdoor units and antennas should be installed ONLY by experienced installation
professionals who are familiar with local building and safety codes and, wherever
applicable, are licensed by the appropriate government regulatory authorities.
Failure to do so may void the product warranty and may expose the end user or the
service provider to legal and financial liabilities. Siklu LTD and its resellers or
distributors are not liable for injury, damage or violation of regulations associated
with the installation of outdoor units or antennas.
Prudence: Les unités extérieures et les antennes doivent être installés que par des professionnels
expérimentés d'installation qui sont familiers avec les norms locales et les codes de
sécurité et, si applicable, sont agréées par les autorités gouvernementales de
réglementation compétents. Ne pas le faire peut annuler la garantie du produit et
peuvent exposer l'utilisateur final ou le fournisseur de services d'obligations juridiques
et financiers.Revendeurs ou distributeurs de ces équipements ne sont pas responsables
des blessures, des dommages ou violation des règlements liés à l'installation des unités
extérieures ou des antennes. L'installateur doit configurer le niveau de puissance de
sortie des antennes conformément aux réglementations nationales et le type d'antenne.

EH-1200F Installation Manual
Page 5
About this Document
This document is the Installation Manual for the EtherHaul-1200F wireless Link.
It provides product overview and details the installation and initial setup.
For instructions how to use the product’s features, refer to the “EtherHaul Operation,
Administration and Maintenance Manual”.
Note:
Features and functionality described in this document may be available for specific
product models or starting from specific SW version.
Please review the individual product’s release notes to verify if a specific feature is
supported in the product you use.
Applicable Products and Releases
E-Band
oEH-1200F, minimum SW release 6.0.0
oEH-1200FX, minimum SW release 6.0.0
Audience
This document assumes a working knowledge of wireless backhaul platforms and their
operating environments.
This document is intended for use by all persons who are involved in planning, installing,
configuring, and using the EtherHaul system.
Conventions
The following conventions are used in this document in order to make locating, reading,
and using information easier.
Special Attention
Hint:
Informs you of a helpful optional activity that may be performed at the current
operating stage.
Note:
Provides important and useful information or describes an activity or situation that
may or will interrupt normal operation of the EtherHaul system, one of its
components, or the network.

EH-1200F Installation Manual
Page 6
Caution:
Describes an activity or situation that requires special attention.
Text Conventions
Document References
Italicized text is used to reference sections or chapters
in this document. In many cases, references use
clickable hypertext links that enable immediate access
to referenced objects.
Command Input
Monospace text is used to help delineate command line
user input or text displayed in a command window.

EH-1200F Installation Manual
Page 7
TABLE OF CONTENTS
1Introduction to the EtherHaul System........................................................10
1.1 Main Features ...........................................................................................................11
1.2 Functional Description..............................................................................................13
1.3 Technical Specifications............................................................................................14
1.4 Licensing..................................................................................................................15
1.5 Management .............................................................................................................15
2Installing the EtherHaul System .................................................................17
2.1 Preparing the Site......................................................................................................17
2.1.1 Physical and Environmental Requirements....................................................18
2.1.2 Cabling Requirements...................................................................................18
2.2 EtherHaul Package Content.......................................................................................19
2.3 Unpacking the EtherHaul..........................................................................................19
2.4 Required Tools..........................................................................................................20
2.5 Preparing for Installation...........................................................................................20
2.6 Mounting the EtherHaul............................................................................................22
2.7 Installing the ODU with a Two Foot Antenna............................................................24
2.8 Connecting the Cables...............................................................................................26
2.8.1 Power Options..............................................................................................26
2.8.2 DC Power Supply Notes ...............................................................................27
2.8.3 Grounding the EtherHaul..............................................................................28
2.8.4 Preparing the Cables.....................................................................................29
2.8.5 Removing Connectors from the EtherHaul ODU...........................................30
2.8.6 Connecting DC Power ..................................................................................30
2.8.7 Connecting Other Interfaces..........................................................................30
2.9 System LEDs ............................................................................................................31
2.10 Aligning the Antenna................................................................................................31
2.10.1 Setting the ODU to Alignment Mode............................................................32
2.10.2 Performing the Alignment ............................................................................32
2.11 Link Up Verification.................................................................................................33
3Performing Basic Setup Using the Web-Based Management..................35
3.1 Connecting to the ODU Using the Web-Based Management .....................................36
3.2 Main Page.................................................................................................................37
3.3 General Configuration Commands ............................................................................39
3.3.1 Apply ...........................................................................................................39
3.3.2 Save Configuration.......................................................................................39

EH-1200F Installation Manual
Page 8
3.3.3 Rollback.......................................................................................................40
3.3.4 Reset ............................................................................................................40
3.3.5 Copy To Remote ..........................................................................................40
3.4 Quick Configuration Wizard .....................................................................................41
3.4.1 Quick Configuration: Step 1 –System ..........................................................41
3.4.2 Quick Configuration: Step 2 –Radio ............................................................41
3.4.3 Quick Configuration: Step 3 –Eth Ports .......................................................43
3.4.4 Quick Configuration: Step 4 –Network ........................................................44
3.5 Radio Page................................................................................................................45
3.5.1 Settings ........................................................................................................45
3.5.2 Advanced Settings........................................................................................47
3.5.3 Maintenance.................................................................................................49
3.5.4 Modulation Table .........................................................................................49
3.5.5 Statistics.......................................................................................................50
3.6 Default Bridge Configuration....................................................................................50
4Commissioning and Acceptance Procedure.............................................51
4.1 Installation Verification and Testing..........................................................................51
4.1.1 Physical Installation Verification ..................................................................51
4.1.2 RF Link Test ................................................................................................51
4.1.3 Link Errors Test............................................................................................51
4.1.4 Ethernet Services Test ..................................................................................52
4.1.5 Management Verification .............................................................................52
4.1.6 Recording ODU Configuration .....................................................................52
4.2 EtherHaul Commissioning and Acceptance Form......................................................52

EH-1200F Installation Manual
Page 9
TABLE OF FIGURES
Figure 1-1 Hitless Adaptive Bandwidth, Coding and Modulation ........................................13
Figure 1-2 EH-1200F (FDD) Functional Block Diagram.....................................................14
Figure 2-1 EtherHaul Mounting Assembly Components......................................................22
Figure 2-2 Quick Release Hooks.........................................................................................23
Figure 2-3 EtherHaul ODU for 2ft Antenna.........................................................................24
Figure 2-4 EtherHaul ODU installed on 2ft Antenna ...........................................................24
Figure 2-5 EtherHaul Connection Panel Details...................................................................26
Figure 2-6 DC Connector....................................................................................................27
Figure 2-7 Grounding Scheme ............................................................................................28
Figure 2-8 All-Weather Connecting Cable Shell Assembly .................................................29
Figure 3-1 Launching the Web-Based Management ............................................................36
Figure 3-2 Entering Username and Password ......................................................................36
Figure 3-3 Web-Based Management Main Page..................................................................36
Figure 3-4 Copy To-Remote icon........................................................................................40
Figure 3-5 Quick Config Page: Step 1 - System...................................................................41
Figure 3-6 Quick Config Page: Step 2 - Radio.....................................................................41
Figure 3-7 Quick Config Page: Step 3 –Eth Ports...............................................................43
Figure 3-8 Quick Config Page: Step 4 –Network................................................................44
Figure 3-9 Radio Page: Settings ..........................................................................................45
Figure 3-10 Radio Page: Advanced Settings........................................................................47
Figure 3-11 Radio Page: Maintenance.................................................................................49
Figure 3-12 Radio Page: Modulation Table .........................................................................49

EH-1200F Installation Manual
Page 10
1 Introduction to the EtherHaul System
This chapter provides a brief overview of the EtherHaul product line.
The EtherHaul radio delivers carrier-grade wireless point-to-point gigabit Ethernet
services utilizing the 57-66GHz unlicensed V-band and the light-licensed 71-76/81-
86GHz E-band spectrum.
The EtherHaul is based on Siklu’s revolutionary integrated-silicon technology, which
results in a highly reliable, zero footprint, and low-cost radio.
The EtherHaul offers Gigabit throughput, MEF-compliant networking, 8 levels of QoS,
enhanced Hitless Adaptive Bandwidth, Coding & Modulation for maximum spectral
efficiency, and services availability. It supports network synchronization, advanced
OAM&PM tools and ring protection optimized for both small cell and mobile backhaul. It
features multiple GbE interfaces, including optical, supporting complex network
topologies, such as daisy chain, ring, and mesh. The multiple ports enable also
colocation installation and leveraging the infrastructure for additional fixed services
delivery. The EtherHaul is fast, simple and inexpensive to deploy.
EtherHaul as the ideal solution for mobile backhaul and business services delivery
features:
Field proven technology
Reduced TCO and fast ROI
All-outdoor invisible footprint
oSmall and light
oQuick and easy to install
Spectral efficient
oWide range of frequencies
oTDD modulation with seamless delay and jitter
oHitless Adaptive Bandwidth Coding and Modulation for high availability
Advanced layer-2 features:
oMEF-compliant services and QoS
oVLAN & Provider Bridge with 16K jumbo frames support
Clear separation between multiple services with QoS
Enables QoS aware MPLS services delivery
oSLA assurance
Advanced AES encryption for secured street level deployments

EH-1200F Installation Manual
Page 11
Highly-scalable, the EtherHaul products are software-upgradable to support future
Layer 2.5/3 networking and routing capabilities as networks evolve to flat-IP topologies.
The EtherHaul products features advanced adaptive modulation, bandwidth and coding
- allowing operators to maintain, prioritize, and verify QoS in all weather conditions,
while achieving maximum (up to 99.999%) link availability for prioritized services such
as voice signaling and Sync.
Offering easy and low cost all-outdoor installation and a small form factor, the
EtherHaul products are also environmentally-friendly - boasting a small system and
antenna footprint with especially low power consumption.
The EtherHaul systems are High-capacity Gigabit Ethernet backhaul, with advanced
networking capabilities, at the lowest TCO in the industry. EtherHaul enables mobile
operators to profitably and reliably provide data intensive services. Provided by Siklu,
the pioneer in silicon based mm-waves backhaul systems, EtherHaul systems are the
perfect choice for future proof investment.
1.1 Main Features
Siklu’s EtherHaul wireless backhaul radio link operates in the new V -band and E-band
spectrum, which provides clear technological and economic advantages over the
existing lower frequency bands. Taking advantage of the new spectrum, the EtherHaul
enables easy migration to support Gigabit throughput, enabling operators to enhance
bandwidth capacity on a “pay as you grow” basis. Supporting point-to-point, daisy-
chain, ring, and mesh configurations, the EtherHaul system offers carrier class
availability and services.
The following are some of the main features of the EtherHaul (availability of features
depends on platform):
All-Outdoor Packet Radio
Operates in the light-licensed 71-76/81-86 GHz E-Band
Up to 1 Gbps throughput
Asymmetric capacity configuration
High gain narrow beam-width directional antenna
Low latency
Highest Spectral Efficiency
250 MHz, 500 MHz channel bandwidth
Advanced hitless/errorless Adaptive Bandwidth, Coding and Modulation
(ABCM) for a large dynamic range
Configurable center frequency across the entire band

EH-1200F Installation Manual
Page 12
Carrier Ethernet Inside:
Integrated Gigabit Ethernet switch
Advanced bandwidth-aware QoS capabilities
MEF compliant services and QoS
Advanced service management, OAM and SLA assurance support
SyncE, IEEE 1588TC and optimized transport of IEEE 1588
Ring, mesh and daisy chain topologies for carrier grade availability and
resiliency
Standard-based for seamless integration into existing networks and multi-
vendor interoperability
Multi-vendor interoperability approved
Carrier Grade:
CLI, SNMP and web-based local and remote management
Extremely high reliability with very high MTBF
Designed for ultra-low MTTR without the need for antenna realignment
Green Design:
Zero footprint, all-outdoor, extremely light weight
low power consumption
IEEE 802.3at+ complaint Power over Ethernet
Quick and Easy Installation
Rapid and flexible deployment
Precise antenna alignment
Minimal site preparation
Security
Advanced AES encryption and security
Narrow and secure beam-width
Adaptive Bandwidth, Coding and Modulation
The EtherHaul family implements hitless/errorless adaptive bandwidth, coding and
modulation adjustment to optimize the over-the-air transmission and prevent weather-
related fading from disrupting traffic on the link. The EtherHaul can gain up to 21 dB in
link budget by dynamically adapting: Modulation, FEC coding rates, and channel
bandwidth maintaining the high priority traffic using quality of service advanced
mechanism and dropping the traffic according to the QoS priority defined by the user.

EH-1200F Installation Manual
Page 13
Figure 1-1 Hitless Adaptive Bandwidth, Coding and Modulation
1.2 Functional Description
The EtherHaul is an all-outdoor system comprised of the following functional blocks:
RFIC: Siklu’s integrated Silicon Germanium (SiGe) transceiver operating at 57 -
66GHz (EH-600T), 71-76GHz (EH-1200/EH-1200T) or 71-76/81-86GHz (EH-
1200F).
Modem/Baseband ASIC: Siklu’s modem/baseband ASIC includes the modem, FEC
engines, and Synchronous Ethernet support.
Network Processor: the networking engine is the heart of the high speed
bridge/router function. The engine receives packets from Ethernet interfaces
the modem and CPU. It is responsible for proper forwarding between these all
interfaces.
Interfaces: The network interface consists of 2-4 integrated 100/1000 Ethernet
ports, depends on the product type.
Host processor (CPU) the host processor controls the system responsible for the
control plane, and the antenna alignment.
Antenna: Siklu’s self-designed 1ft innovative antenna, as well as 2ft antenna
option for longer range higher availability.

EH-1200F Installation Manual
Page 14
Figure 1-2 EH-1200F (FDD) Functional Block Diagram
1.3 Technical Specifications
For detailed technical specifications please refer to the datasheet.
For detailed supported features list please refer to the product’s release notes.
EtherHaul-1200F
Technology and frequency
FDD, 71-76/81-86GHz
Modulation
QPSK/QAM16/QAM64
Adaptive modulation
Hitless adaptive bandwidth, coding and modulation, boosting system
gain by 25dB
Over-the-air throughput
Up to 1000Mbps full-duplex
Typical link distance
Up to 4500m (maximum 7000m)
Interfaces
EH-1200F: 4xGE - 2xCopper+ 2xFiber ports or 1xCopper+ 3xFiber ports
EH-1200FX: 2xGE - 2xCopper
Antenna
Integrated 1ft (31cm) Cassegrain reflector - 43dBi antenna gain,
External 2ft (65cm) Cassegrain reflector -50dBi antenna gain
Power options
PoE+ (IEEE 802.3at)
Direct Telco DC: ±36-57VDC
Ethernet features
VLAN (IEEE 802.1q) and VLAN stacking (Q-in-Q, IEEE 802.1ad Provider
Bridge)
IEEE 802.1d Transparent Bridging
Advanced QoS &Traffic management- 802.1p, DSCP & MPLS EXP
oScheduling , Shaping, Policing
MEF 9,14 and 21 compliant
Ethernet OAM and CFM (IEEE 802.1ag / ITU-T Y.1731 / IEEE 802.3ah)
Ethernet Ring Protection (ITU-T G.8032)

EH-1200F Installation Manual
Page 15
MAC learning
Link state propagation
Jumbo frames
Synchronization
IEEE 1588 TC
Synchronous Ethernet ITU-T G.8261/8262/8264
Network topologies
Ring, daisy-chain and mesh
Encryption
AES 128-bit and 256-bit
Management
In-band, out-of-band, embedded CLI, web GUI, SNMPv2/3
System modes
Adaptive modulation
Symmetrical uplink/downlink ratio or Asymmetrical
Alignment
Environmental
Operating temperature: -45° ÷ +50°C
Ingress protection rating: IP67
Dimensions and Weight
24.5 cm x 22.5 cm x 7 cm
ODU + 1ft Antenna (Dia. x Depth) -31 cm x 13 cm
Weight ODU + antenna (1ft): 4 kg
1.4 Licensing
The EtherHaul family provides for easy migration to support Gigabit throughput,
enabling operators to enhance bandwidth capacity on a “pay as you grow” basis as well
as adding features and capabilities according to their networks evolutions. You can
order the following EtherHaul software (capacity steps and feature availability depend
on your platform):
Data rates
Layer 2 networking capabilities –OAM and Resiliency
Synchronization –Synchronous Ethernet (ITU-T G.8261) and IEE-1588TC
Encryption.
Vlan configuration and Provider-Bridge settings capabilities are enabled by default and
do not require a license.
The software licenses are serial number dependent.
1.5 Management
You can manage an EtherHaul system using a Web-Based Element Management System
(Web EMS) or a Command Line Interface (CLI). The CLI is compatible with SNMP.
Advanced network features must be managed using the CLI.

EH-1200F Installation Manual
Page 16
The EtherHaul system features a wide range of built-in indicators and diagnostic tools
for advanced OAM functionality. The system is designed to enable quick evaluation,
identification, and resolution of operating faults.

EH-1200F Installation Manual
Page 17
2 Installing the EtherHaul System
This chapter describes how to install and perform the basic setup for EtherHaul outdoor
unit (ODU) in an EtherHaul wireless network, including:
Preparing the Site
EtherHaul Package Content
Unpacking the EtherHaul
Required Tools
Preparing for Installation
Mounting the EtherHaul
Installing the ODU with a Two Foot Antenna
Connecting the Cables
System LEDs
Aligning the Antenna
Link Up Verification
The installation of the EtherHaul system is followed by initial system setup that will be
described in the next chapter.
Caution:
The installation and maintenance of the EtherHaul link should only be done by
service personnel who are properly trained and certified to carry out such
activities.
Caution:
It is the responsibility of the installer to insure that when using the outdoor
antenna kits in the United States (or where FCC rules apply), only those
antennas certified with the product are used. The use of any antenna other
than those certified with the product is expressly forbidden in accordance to
FCC rules CFR47 part 15.204.
2.1 Preparing the Site
Carefully select and prepare each EtherHaul ODU site to make device installation and
configuration as simple and trouble-free as possible. During site selection and
preparation, always consider the long-term needs of both your network and your
applications.

EH-1200F Installation Manual
Page 18
2.1.1 Physical and Environmental Requirements
Each EtherHaul ODU site should adhere to the following requirements:
There must be a clear, unobstructed line-of-sight between ODU.
The EtherHaul ODU should be mounted on a fixed, stable, permanent
structure. A reinforced steel mounting pole is required, with a diameter
measuring from 2-4 inches (1ft antenna) or 2-4.5 inches (2ft antenna).
Caution:
Do not mount the EtherHaul device on a structure that is temporary or easily moved.
Doing so may result in poor service or equipment damage.
You must mount the EtherHaul ODU in a site that is easily accessible to
authorized personnel, and only authorized personnel.
Operating temperature: between -45° and +55°C.
Relative humidity: 0 to 100%.
Maximum altitude: 4,500m.
Ingress Protection rating: IP67.
2.1.2 Cabling Requirements
Ensure that your power connection cable matches the EtherHaul power
connector pin-outs.
Install the EtherHaul ODU where network connections and optional power
cabling are ready for operation and easily accessible.
All cabling connected to the ODU should be outdoor-grade, with UV
protection.
Use a two-wire cable (14-18 AWG) to connect the power supply to the ODU.
You should use shielded outdoor Cat5e cables terminated with metallic RJ45
connectors.
In order to protect indoor equipment, you must install surge protection
circuits on all copper cables on their entrance to the building.
Install the EtherHaul ODU in a location where proper electrical outdoor
grounding is readily available. Typically, the grounding connection is
attached directly to the mounting pole. If not already present, then suitable
structure-to-earth grounding connections must be created before
installation. Ground the ODU using a minimum quantity of 16AWG
grounding cable or according to local electrical code.
Caution:
Improper electrical grounding can result in excessive electromagnetic interference or
electrical discharge.

EH-1200F Installation Manual
Page 19
Siklu will not be held responsible for any malfunction or damage in the event that the
ODU is not properly grounded.
2.2 EtherHaul Package Content
An EtherHaul link consists of two ODUs and two mounting assemblies.
The EtherHaul packages include the following components:
Package
Description
EH 600T Quantity
EtherHaul-
1200F ODU
EtherHaul 1200F ODU with
1ft integrated antenna
1
Connecting cable All-
Weather shells
3
Fiber extension All-
Weather shells
2
Unit grounding cable (90
cm)
1
DC cable terminal block
connector
1
EtherHaul 1200F
mounting
assembly
EtherHaul 1200 mounting
assembly
1
2.3 Unpacking the EtherHaul
The EtherHaul package content should be examined carefully before installation.
When you unpack the components of the EtherHaul, it is important to use care so as to
avoid damaging or scratching the antenna radome:
Do not touch the radome when unpacking the ODU.
Do not rest the ODU face down or touch the radome. It is crucial to prevent
contact between the radome and other objects.

EH-1200F Installation Manual
Page 20
2.4 Required Tools
Ensure that you have the following tools with you when performing an EtherHaul
installation:
Standard handheld digital voltage meter (DVM) with probes
Standard open-end wrench, 13 millimeter
8mm Allen key for ODU installation with 2ft antenna
Philips screwdriver, medium size head for grounding connection
Flat-head screwdriver, small size (2mm) head for DC connector
Cable ties (for securing network and optional power cables)
Cutter
Cable labeling
2.5 Preparing for Installation
The expected receive signal strength should be calculated prior to installing the link for
each antenna ODU (read from the DVM) prior to installation, based on the network link
budget.
Calculating the expected RSSI:
Where:
Ptx –ODU’s Tx Power (typically +5dBm)
Gant1 –Gain of antenna 1 (typically 35dBi)
Gant2 –Gain of antenna 2 (typically 35dBi)
LFS –Loss of Free Space = 92.45+20*Log (DKm*FGHz)+
-D - Link distance in Km
-F –Frequency in GHz
Attatm –Attenuation due to Atmospheric Gases (dB/Km)
For E-band links, the Attenuation due to Atmospheric Gases is typically
0.5dB/Km.
For V-band links, the Attenuation due to Atmospheric Gases is significantly
higher (up to 15dB/Km) and depends on the specific channel used and the exact
geographical location.
Refer to EtherHaul Link Budget Calculator for on-line calculation of expected
availability and expected RSSI.
RSSI = Ptx + Gant1 –LFS –Attatm + Gant2