Silent Alert CL4A-2212-EU MKII User manual

Quick start guide CL4A-2212-EU MKII
Mini Chair Leaving Monitor
Any questions? Call us on 01246 450789
PM5 Activation
Status light
Test button
Configuration
switch Cover
PP3 battery
contacts
Screw cap
Screw cap
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silent-alert.co.uk
Clofield Ltd. UK
Tel: 01246-260045
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 Battery The light will then will flash
green several times to show the
battery voltage.
9 flashes = 9Volts in the battery.
When a battery is first fitted the
indicator light will flash red then
green a few times.
1. Install a 9 volt PP3 alkaline or lithium battery
making sure to observe the correct polarity.
If the light flashes red at this
point the battery is flat
and will need to be replaced.
To repeat the battery check remove the battery, press the test
button then re-insert the battery to start the sequence again.
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silent-alert.co.uk
Clofield Ltd. UK
Tel: 01246-260045
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
Pressure pad
socket
1 2 3 4 5 6 7 8
Configuration switches shown
with cover removed. Do not alter
these without referring to page 2
2. The monitor is activated using a chair pressure pad
(PM5).
The monitor may transmit the first
time the connection is made, this
is normal.
Plug the PM5 plug into the
socket on the monitor
The 3.5mm jack socket will trigger
the unit on a short circuit only.
3. Place the pad under the chair cushion ensuring
the pad is not folded.
When installing the pad make sure the cable can't
cause a trip hazard.
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
4. As the user stands up the monitor will send a
signal to the Pager or SignWave.
5. Fidget delay To prevent the unit triggering
when the user changes position in
their seat the monitor has a
'fidget' delay.
If the person releases the
pressure from the pad a timer will
start, this is indicated by the green
light flashing on the monitor.
After 3 - 4 seconds the monitor will trigger. However,
if the person sits back down the light will switch off
and the monitor will not transmit.
1 2 3 4 5 6 7 8
If this delay is not required or if
the monitor is being used to detect
an open circuit switch key 6 to on.
The unit will now send radio as
soon as it is triggered.
! The Mini Monitor socket can be used with auxiliary equipment that presents a short
circuit to a 3.5mm jack plug. DO NOT connect the unit to voltage or damage may occur
to the unit. If in doubt, please call 01246 450789.
TM
Alert
Silent

Advanced settings CL4A-2212-EU MKII
Mini Chair Leaving Monitor
Any questions? Call us on 01246 450789
It is possible for the monitor to light up a different key on the Pager or SignWave. This
allows more than one chair leaving monitor to be used on a SA3000 system.
Changing the system channel code
NOTE. In most cases it is not necessary to change the system code. However, when
one or more systems are in close proximity, system codes can be used to avoid
interference from other SA3000 systems using up to a maximum of 16 channels.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
KEY 7 MUST BE LEFT ON
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
23456 7 8
1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
9
1 2 3 4 5 6 7 8
10
1 2 3 4 5 6 7 8
12
1 2 3 4 5 6 7 8
11
1 2 3 4 5 6 7 8
13
1 2 3 4 5 6 7 8
14
1 2 3 4 5 6 7 8
15
1 2 3 4 5 6 7 8
16
1 2 3 4 5 6 7 8
Move the relevant key
to the right .
Trigger the unit and
check the correct event
is received by the
Pager or SignWave.
Key 7 must be left on.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1.
To change the delay you need to
reset the monitor:
Remove the battery,
press the push button,
replace the battery.
Changing the trigger delay
It is possible to set trigger delays allowing a set amount of time to pass for the user to return to the chair
before the monitor will transmit.
Press and release the
button whilst the light
is green. The light will
flash red once, twice
then three times .
3.
To set the delay,
briefly press the test
button at the
desired number
of flashes.
4.
The monitor will then
perform the battery voltage
level display and start as
normal. Press the test button
to confirm the correct zone
has been selected.
6.
After the flashing red/
green startup
sequence the light will
shine constant green.
2.
5. 1 flash = 10 seconds
2 flashes = 20 seconds
3 flashes = 30 seconds
The indicator light will light
green to confirm
the selection.
WARNING! Your device and its accessories are not toys.
They may contain small parts. Keep them out of the reach
of small children.
Do not immerse the
Monitor in water or any
other liquid.
Do not disassemble
Do not disassemble.
Silent Alert SA3000 system
Operating Frequency: 869MHz
Output power: <10mW
Hereby, Clofield Ltd declares this radio
equipment is in compliance with
Directive 2014/53/EU.
The full text of the EU declaration can be found at
www.silent-alert.co.uk
TM
Alert
Silent