Quick start guide UM3A-2212-EU MK XI
Universal monitor
Any questions? Call us on 01246 450789
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU MK XI
Universal Monitor 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
1 = System Code 1
2 = System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = System Code Override
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = Poling signals
10 = Sound Level Display
11 = Smoke / Fire
12 = Burglar/ Car
13 = Baby Alarm
14 = Person to Person
15 = Door Bell
16 = Telephone
MOVE KEY DOWN
TO SWITCH ON
Configuration switches
Audio spindle
Test button
PP3 battery clip
Power Supply socket
Input terminals
Move Key 15 to the right. Connect a 9V
Alkaline PP3 to the battery clip.
1.
Press and briefly hold the test button
The light will shine green and the monitor will
send a signal.
2.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU MK XI
MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11= Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Alkaline
Check the desired signal is
received by the Pager or
SignWave and fix in place
using the screw kit or
Velcro provided
An Alkaline PP3 battery should last one year.
3.
Low battery signals will be sent to
your Pager or SignWave when
the battery needs replacing.
The test button will also shine
orange to show the status of
the battery.
Only use Alkaline or Lithium PP3
batteries as cheaper alternatives
will not last as long.
4. The input terminals can be used to
connect to doorbells, door entry
phones, fire, burglar & car alarms.
Short Circuit triggering
A short applied across the
top and bottom terminal will
trigger the unit.
Voltage triggering
A voltage applied across
terminals 1 & 2 will also
trigger the unit. Both AC and
DC voltages from 5 - 30 Volts
will activate the unit.
5. 6.
WARNING
LOW VOLTAGE
DO NOT apply mains power or any voltage in
excess of 30 Volts as damage will result.
Only suitably qualified persons should attempt to
link this unit into systems or equipment other
than a low voltage door chime
UM3A-2212-EU-MKX
Universal Monitor 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
7. 8.
Common (negative)
to terminal one
Wiring example
When wiring across a coil
or similar use the
voltage input.
Or, when wiring parallel
across a bell push use the
short circuit input.
Make sure the common
(negative) wire on the bell push
is connected to the bottom
terminal to avoid
false triggering.
TM
Alert
Silent