Silent Alert UM3A-2212-EU-PSU User manual

TM
Silent
Alert
Quick start guide UM3A-2212-EU-PSU
Smoke / Carbon Monoxide Monitor with inline PSU
CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
MOVE KEY DOWN
TO SWITCH ON
Any questions? Call us on 01246 450789
12345
B
54
3
2
1
ON /OFF
ON
1
2
3
1.
A
4
A
4
5
4
5
SW3935
I/P: AC 100-240V
O/P: DC 9V 1.3A
Power supply
Connect the power supply to
a 13 Amp fused spur.
WARNING
This product should only be installed by
a suitably qualified person.
Clofield take no responsibility for damage
caused by incorrect fitting.
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
Test button
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU-PSU
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENT-ALERT.CO.UK CLOFIELD LTD. UK
TEL 01246 260045
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Alkaline
NOTE: if this is done in
reverse order a low battery
signal will be sent out and
the test/send button will
shine orange instead of
green for up to 9 hours.
Power the unit.
WARNING. DO NOT APPLY MAINS VOLTAGE TO THE UNIT AS THIS WILL CAUSE IRREVOCABLE DAMAGE,
CAUSE INJURY AND CREATE A FIRE HAZARD.
Volt-free relay / short circuit activation
The UM3A-2212-EU-PSU should ideally be connected to interconnected smoke
alarms via a normally open volt-free relay using terminals 1 & 3 as shown.
Low voltage activation
Link the Monitor via terminals 1 & 2 (middle and bottom terminals). Link the
LOW VOLTAGE Interlink Terminal within the device to terminal 2 (middle
terminal) on the monitor and the Neutral terminal within the alarm to Terminal 1
(bottom terminal) on the Monitor.
Activate the alarm system, this will cause the monitor to transmit a radio signal
and the green light on the front of the unit will go out momentarily.
Test the unit in position then fasten to the wall with the screw kit provided.
2. Interconnect smoke / heat / Carbon Monoxide connection
Switch the mains off,
remove the battery and
reset the unit using the
procedure in step 1.
●
●
●
This monitor will send a
fire signal by default.
It can be configured to transmit a
Carbon Monoxide signal (see reverse).
Connect a PP3 battery to the
unit then power the unit by
switching the mains on.
The test button will light
green, this is normal.
PLEASE NOTE.
THIS PRODUCT DOES NOT COMPLY WITH BS5839-1 2002. HOWEVER, THE FIRE SAFE INTERFACE PANEL, ALSO
AVAILABLE FROM CLOFIELD LTD (PART NUMBER FSTX-2225-EU) DOES.
1
3
1
2

Any questions? Call us on 01246 450789
TM
Alert
Silent
The monitor can be coded to light the Fire symbol red or blue on the Pager or SignWave.
The diagram below shows the relevant key settings.
Additional Settings
Changing the system channel code
NOTE: In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other SA3000 systems using up to a maximum of 16 channels.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
23456 7 8
9 10 11 12 13 14 15 16
1
1
2
3
4
5
6
7
8
System Channel override
Switch 6 acts as a system channel override. This can be useful when a
number of systems are being used in close proximity and are on different
system codes, so as not to interfere with each other.
.
An example would be a multi occupancy building where two or
more users have systems alerting them of their doorbell, telephone
and smoke alarm in self contained flats.
The UM3A-2212-EU-PSU can be linked into smoke alarms in
communal areas . Setting key 6 will ensure all systems respond
when the Universal Monitor triggers as the signal will override all
system channels.
9
10
11
12
13
14
15
16
Co Signal
The Univers
al Monitor can
also send a CO signal
if required.
Switch key 15 to the right .
The monitor will now
transmit a CO signal when
triggered and will light the
Fire key blue on the receiver.
Quick start guide UM3A-2212-EU-PSU
Smoke / Carbon Monoxide Monitor with inline PSU
PLEASE NOTE.
THIS PRODUCT DOES NOT COMPLY WITH BS5839-1 2002. HOWEVER, THE FIRE SAFE INTERFACE PANEL, ALSO
AVAILABLE FROM CLOFIELD LTD (PART NUMBER FSTX-2225-EU) DOES.

Any questions? Call us on 01246 450789
TM
Alert
Silent
The Monitor can be configured to poll every 5 minutes where radio integrity checking is required.
Advanced Settings
Range Test mode
To perform a range test mode switch key
16 to the right.
On the receiver, switch keys 5, A & B on
to the left.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
Pager
A
B
54
3
2
1
ON /OFF
ON
SignWave
The monitor will send a signal every 5 seconds. The
receiver will display the signal strength by lighting a
symbol on the receiver.
Walk around the area you need to cover to ensure total
site coverage. The battery key represents the lowest
point at which the signal strength is reliable.
100%
Signal Strength
Quick start guide UM3A-2212-EU-PSU
Smoke / Carbon Monoxide Monitor with inline PSU
Radio Interlace
If two or more monitors in close
proximity are configured to
polling mode a transmission
delay on one monitor is required.
Switch key 8 to the right on one
of the monitors.
When the unit is triggered there
will now be a three second delay
before it transmits.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
(only required if 2 or more Universal Monitors are used)
Polling signal
Switch key 9 to the right.
The unit will now send a
polling signal every
5 minutes.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
Configure the Pager or SignWave as shown
(switch keys 5 & A on to the left).
The Smoke symbol will flash red every seven seconds
to show the receiver is monitoring for radio integrity.
If the Pager or SignWave doesn't receive a signal within
5 minutes it will flash all lights and alarm 5 times.
This will continue every 5 minutes until a valid polling
signal is received.
Pager
A
B
54
3
2
1
ON /OFF
ON
SignWave
Receiver configuration for polling (radio integrity check)
PLEASE NOTE.
THIS PRODUCT DOES NOT COMPLY WITH BS5839-1 2002. HOWEVER, THE FIRE SAFE INTERFACE PANEL, ALSO
AVAILABLE FROM CLOFIELD Ltd (PART NUMBER FSTX-2225-EU) DOES.
Popular Smoke Alarm manuals by other brands

First Alert
First Alert SA100B user manual

family first
family first FFP9VH user manual

x-sense
x-sense XS01-WR user manual

Bentel Security
Bentel Security ZT100P quick start guide

Wheelock
Wheelock SAFEPATH SCSP-4RP Installation, testing, operation and maintenance manual

Pittway
Pittway 2112/24D Installation and maintenance instructions