Three-phase, four-module electricity meter
Description of the SIMLIC LS-3 meter
series
The SIMLIC LS-3 series are three-phase, four-module electricity meters with an LCD display.
They can be used for measurements in commercial and industrial applications. Depending on
your needs, you can choose from three product models.
LS-3F - measurement and indication of active energy (kWh) and power (W), the meter
indicates total energy consumption and consumption over time (RESET function)
LS-3FD - measurement and indication of active energy (kWh)
LS-3FB -measurement and indication of active energy (kWh) consumed and exported
(import/export) and power (W). It can be used to measure renewable energy. RESET function
(measurement in a selected time)
The RESET button located on the front of the LS-3F and LS-3FB meter performs two functions:
- short pressing switches the particular views on the display,
- pressing and holding for approx. 3 secondsresetsthe partial energymeasurement. Themeters
are equipped with an additional pulse output, which makes it possible to connect the meter.
Technical data
Safety instructions
Information for your safety
SIMLIC LS-3 series electricity meters are used to measure the electricity consumption in
three-phase networks to which they should be connected by a qualified electrician in
accordance with the applicable standards, after reading this manual. Before starting the
installation, check whether the connection cables are live. Make sure that the meter is not
damaged, deformed or any elements are missing. Consult the manufacturer in case of
malfunction.
Correct use of the SIMLIC LS-3 series meter
The basic factors necessary to ensure the proper operation of the device is proper transport,
storage, installation and its connection. Do not forget about proper operation and ensuring the
proper condition of the device during its operation. During operation of the device, its
components may be under voltage dangerous to human health. You must be particularly
careful.
use only insulated tools to operate the device,
installation works should be carried out with the voltage off,
the place for installation should be dry,
the product should not be installed in potentially explosive areas or where it will be
exposed to dust, mould or insects,
make sure that the connecting cables are able to carry the maximum currents for a
given meter,
before starting themeter, make sure that the power cables are correctly connected
to the meter terminals,
touching the meter's connection terminals with bare hands, metal objects,
uninsulated wire or other conductive objects creates a risk of electric shock,
after installation, it is absolutely necessary to put on the terminal covers (protective
covers),
installation, inspections, optional repairs should be carried out by persons with
appropriate qualifications,
unauthorised persons, without proper qualifications, should never remove the
protective covers or interfere with the meter components,
the meter should be protected against falls and mechanical shocks, precise
elements inside the device may be damaged, which will result in lack of accuracy of
the measurements.
The crossed-out bin symbol on your device indicates that the product marked with it must not be
disposed of with household waste. After use, return the product to a collection point for electrical
and electronic equipment or return it to your dealer. It is the responsibility of the user to return
the device to the appropriate collection point or to the dealer when it is no longer used.
Appropriate segregation of waste for post-treatment, recovery or destruction contributes to
avoid negative environmental and health impacts and enables the recovery of theraw materials
from which the product is made. For more detailed information on available collection points,
please contact your local cleaning service or the shop where you have purchased the product.
External dimensions
Specifications
Nominal voltage (Un)
230V/400V AC (3~)
Voltage measuring range
80%~120% Un
Insulating capacity
- AC surge voltage
4kV for 1 minute
- surge, impulse voltage
6kV-1.2/50µS
Base current (Ib)
10A
Maximum current (lmax)
100A
Reference current (Iref)
20A
Start-up meter current (Ist)
0,04A
Minimum current (Imin)
0,5A
Running current range
0.4% lb~lmax
Current overload
30lmax for 0.01s
Rated frequency
50Hz ± 10%
Own collection
≤ 2W/10N/A
Pulse output
1000imp/kWh
Maximum indication
999999,9 kWh
Performance criteria
Relative humidity (without condensation)
≤ 90%
Storage humidity
≤ 95%
Working temperature
-25°C - +55°C
Storage temperature
-40°C - +70°C
Active energy measuring accuracy
Class B EN50470-1/3
Class 1IEC 62053-21
Protection level
IP51
Insulation class in the enclosure
II
Start-up time
10 seconds
Mechanical environment
Ml
Electromagnetic environment
E2
Pollution degree
2
Height
100m
m
Width
72mm
Depth
66mm
Display functions
Start screen
After commissioning, the meter will carry out a self-test procedure.
Home screen
Software version
Pulse output constant
Total active energy
The default displayedvalue for LS-3F and LS-3FD is the value of active energy
(kWh), for LS-3FB it is the value of active energy consumed (import).
Switching display views
The display menu of the LS-3F and LS-3FB meters can be scrolled using the
button on the front panel of the meter.
Measurement of energy consumption over a
specific time
The LS-3F and LS-3FB meter allows you to measure the energy consumption in a
specific time (between the following presses of the RESET button). Holding the
RESET button for 3 seconds cancels the partial measurement.
Connection diagram
L1 I/O
L2 I/O
L3 I/O
N
Pulse output
Note: the pulse output should be
connected as shown in the diagram.
Special attention should be paid to the
voltage polarity (+/-).
Voltage (Ui): 5-27VDC
Current (lmax): 27mA DC
Pulse duration: 30ms
Installation
TH-35 mounting rail
Declaration of conformity
SIMET S.A., Joint Stock Company based in Al. Jana Pawła II, 58-506 Jelenia Góra hereby
declares that the three-phase electricity meters of the SIMLIC LS-3 series comply with the
requirements of Directive 2014/32/EU (MID). The certificate is issued on the basis of type
examination number: SHES151000648101 dated 19 April 2016.
Certificate number: 0120/SGS0335
Certification body code: 0120

This manual suits for next models

2

Popular Measuring Instrument manuals by other brands

Beha-Amprobe AC50A user manual

Beha-Amprobe

Beha-Amprobe AC50A user manual

Velleman DVM123 manual

Velleman

Velleman DVM123 manual

Shortridge Instruments AIRDATA ADM-850L operating instructions

Shortridge Instruments

Shortridge Instruments AIRDATA ADM-850L operating instructions

Onicon F-4300 Installation & operation guide

Onicon

Onicon F-4300 Installation & operation guide

raditeq RadiSense RSS2010E quick start guide

raditeq

raditeq RadiSense RSS2010E quick start guide

Endress+Hauser Turbimax CUE21 operating instructions

Endress+Hauser

Endress+Hauser Turbimax CUE21 operating instructions

TPI 1010a manual

TPI

TPI 1010a manual

Mitutoyo 500-712-20 user manual

Mitutoyo

Mitutoyo 500-712-20 user manual

SPINK CONTROLS R 300/D SERIES Operator's manual

SPINK CONTROLS

SPINK CONTROLS R 300/D SERIES Operator's manual

BEKA BA504E manual

BEKA

BEKA BA504E manual

NARDA NRA Series Technical note

NARDA

NARDA NRA Series Technical note

Elcometer 148 operating instructions

Elcometer

Elcometer 148 operating instructions

Kobold NBK-19 Operating	 instruction

Kobold

Kobold NBK-19 Operating instruction

Profimess SW-04 Air operating instructions

Profimess

Profimess SW-04 Air operating instructions

Graco 121325 Instructions-parts list

Graco

Graco 121325 Instructions-parts list

Oz electronics MT-901A user manual

Oz electronics

Oz electronics MT-901A user manual

Hach DR 6000 instruction manual

Hach

Hach DR 6000 instruction manual

F.W. Bell 4090 operating instructions

F.W. Bell

F.W. Bell 4090 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.