Simpact Freeway 1100 Manual

Simpact, Inc.
9210 Sky Park Court
San Diego, CA 92123
Freeway
®
1100/1150
Hardware Installation Guide
DC 900-1370E
July 1999

Simpact, Inc.
9210 Sky Park Court
San Diego, CA 92123
(858) 565-1865
Freeway 1100/1150 Hardware Installation Guide
© 1997–1999 Simpact, Inc. All rights reserved
Printed in the United States of America
This document can change without notice. Simpact, Inc. accepts no liability for any errors this
document might contain.
Freeway is a registered trademark of Simpact, Inc.
All other trademarks and trade names are the properties of their respective holders.

DC 900-1370E
3
Contents
List of Figures 5
List of Tables 7
Preface 9
Safety Precautions 15
Freeway 1100 Certifications 21
Freeway 1150 Certifications 25
1 Getting Started 29
2 Hardware Installation 31
3 Configuring the Boot Parameters using the Initialization Disk 45
4 Configuring the Boot Parameters using the Local Console 53
A Electrical Interfaces 65
Index 67

4
DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide

DC 900-1370E
5
List of Figures
Figure 2–1: Front View: Freeway 1100/1150 (glass door not shown) .......... 34
Figure 2–2: Example Back View: Freeway 1100 with ICP2424 (ISAbus) Boards .... 36
Figure 2–3: Example Back View: Freeway 1100 with ICP2432 (PCI Bus) Boards . . . 37
Figure 2–4: Example Back View: Freeway 1150 with ICP2432 (PCI Bus) Boards . . . 38
Figure 2–5: Slidelock on an AUI Connector ....................... 40
Figure 3–1: Example of the Freeway System Boot Parameters ............. 47
Figure 3–2: Configured Freeway System Boot Parameters ............... 50
Figure 4–1: Freeway Boot System Main Menu ...................... 56
Figure 4–2: Example of the Freeway System Boot Parameters ............. 57
Figure 4–3: Configured Freeway System Boot Parameters ............... 62

6
DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide

DC 900-1370E
7
List of Tables
Table 3–1: Freeway System Boot Parameter Descriptions................ 47
Table 3–2: Flags for Reset Action ............................. 49
Table 4–1: Freeway System Boot Parameter Descriptions................ 58
Table 4–2: Flags for Reset Action ............................. 60
Table A–1: Commonly Used Electrical Interfaces .................... 65

8
DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide

DC 900-1370E
9
Preface
Purpose of Document
This document describes the hardware installation procedures for Simpact’s Freeway
1100/1150 communications server. It is used in conjunction with the
Freeway User’s
Guide
, which describes the software installation procedure.
Intended Audience
This document should be read by the computer technician who will be installing the
Freeway communications server. System administrators and system integrators may
also find it useful.
Organization of Document
The “Safety Precautions” section on page 15 describes important safety guidelines that
you should review before beginning the installation.
The “Freeway 1100 Certifications” section on page 21 shows the certifications for the
Freeway 1100.
The “Freeway 1150 Certifications” section on page 25 shows the certifications for the
Freeway 1150.
Chapter 1 is an overview of the Freeway installation procedure.
Chapter 2 describes the hardware installation.
Blind Mpar:
The“Required
Equipment”
section was
intentionally
moved to
Chapter 2.

10
DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide
Chapter 3 describes how to configure the boot parameters using the boot parameter
initialization disk.
Chapter 4 describes how to configure the boot parameters using the local console.
Appendix A shows the commonly used electrical interfaces.
Simpact References
The following general product documentation list is to familiarize you with the avail-
able Simpact Freeway and embedded ICP products. The applicable product-specific
reference documents are mentioned throughout each document (also refer to the
“readme” file shipped with each product). Most documents are available on-line at
Simpact’s web site, www.simpact.com.
General Product Overviews
•
Freeway 1100 Technical Overview
25-000-0419
•
Freeway 2000/4000/8800 Technical Overview
25-000-0374
•
ICP2432 Technical Overview
25-000-0420
•
ICP6000X Technical Overview
25-000-0522
Hardware Support
•
Freeway 1100/1150 Hardware Installation Guide
DC 900-1370
•
Freeway 1200/1300 Hardware Installation Guide
DC 900-1537
•
Freeway 2000/4000 Hardware Installation Guide
DC 900-1331
•
Freeway 8800 Hardware Installation Guide
DC 900-1553
•
Freeway ICP6000R/ICP6000X Hardware Description
DC 900-1020
•
ICP6000(X)/ICP9000(X) Hardware Description and Theory of
Operation
DC 900-0408
•
ICP2424 Hardware Description and Theory of Operation
DC 900-1328
•
ICP2432 Hardware Description and Theory of Operation
DC 900-1501
•
ICP2432 Hardware Installation Guide
DC 900-1502
5/25/99
Ginni:
Removed all
Getting
Started
manuals.

Preface
DC 900-1370E
11
Freeway Software Installation Support
•
Freeway Release Addendum: Client Platforms
DC 900-1555
•
Freeway User’s Guide
DC 900-1333
•
Loopback Test Procedures
DC 900-1533
Embedded ICP Installation and Programming Support
•
ICP2432 User’s Guide for Digital UNIX
DC 900-1513
•
ICP2432 User’s Guide for OpenVMS Alpha
DC 900-1511
•
ICP2432 User’s Guide for OpenVMS Alpha (DLITE Interface)
DC 900-1516
•
ICP2432 User’s Guide for Solaris STREAMS
DC 900-1512
•
ICP2432 User’s Guide for Windows NT
DC 900-1510
•
ICP2432 User’s Guide for Windows NT (DLITE Interface)
DC 900-1514
Application Program Interface (API) Programming Support
•
Freeway Data Link Interface Reference Guide
DC 900-1385
•
Freeway Transport Subsystem Interface Reference Guide
DC 900-1386
•
QIO/SQIO API Reference Guide
DC 900-1355
Socket Interface Programming Support
•
Freeway Client-Server Interface Control Document
DC 900-1303
Toolkit Programming Support
•
Freeway Server-Resident Application and Server Toolkit
Programmer’s Guide
DC 900-1325
•
OS/Impact Programmer’s Guide
DC 900-1030
•
Protocol Software Toolkit Programmer’s Guide
DC 900-1338
Protocol Support
•
ADCCP NRM Programmer’s Guide
DC 900-1317
•
Asynchronous Wire Service (AWS) Programmer’s Guide
DC 900-1324
•
Addendum: Embedded ICP2432 AWS Programmer’s Guide
DC 900-1557
•
AUTODIN Programmer’s Guide
DC 908-1558
•
Bit-Stream Protocol Programmer’s Guide
DC 900-1574
•
BSC Programmer’s Guide
DC 900-1340

12
DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide
Document Conventions
The term “Freeway” refers to either of the Freeway models, 1100 or 1150.
Revision History
The revision history of the
Freeway 1100/1150 Hardware Installation Guide
, Simpact
document DC 900-1370E, is recorded below:
•
BSCDEMO User’s Guide
DC 900-1349
•
BSCTRAN Programmer’s Guide
DC 900-1406
•
DDCMP Programmer’s Guide
DC 900-1343
•
FMP Programmer’s Guide
DC 900-1339
•
Military/Government Protocols Programmer’s Guide
DC 900-1602
•
N/SP-STD-1200B Programmer’s Guide
DC 908-1359
•
SIO STD-1300 Programmer’s Guide
DC 908-1559
•
X.25 Call Service API Guide
DC 900-1392
•
X.25/HDLC Configuration Guide
DC 900-1345
•
X.25 Low-Level Interface
DC 900-1307
Document Revision Release Date Description
DC 900-1370A July 1997 Original release
DC 900-1370B June 1998 Modified for server 2.8 release:
Added Certification section
Updated boot parameters
Documented PC-editable text file
DC 900-1370C August 1998 Modified CPU drawings
DC 900-1370D February 1999 Added Freeway 1150 information
Moved port numbering information to
chapter 5 in this document from user’s
guide
DC 900-1370E July 1999 Updated for server 2.9 release
Removed BOOTP information; no
longer supported
Moved port numbering information to
chapter 2; deleted chapter 5

Preface
DC 900-1370E
13
Customer Support
If you are having trouble with any Simpact product, call us at 1-800-275-3889 Monday
through Friday between 8 a.m. and 5 p.m. Pacific time.
You can also fax your questions to us at (858)560-2838 or (858)560-2837 any time.
Please include a cover sheet addressed to “Customer Service.”
We are always interested in suggestions for improving our products. You can use the
report form in the back of this manual to send us your recommendations.

14
DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide

DC 900-1370E
15
Safety Precautions
English
Be sure to take the following safety precautions during installation and maintenance of
the Freeway communications server:
•Observe the warnings and directions printed on the Freeway server and its asso-
ciated equipment.
•Check the electrical rating label on the Freeway chassis. Be sure that the voltage
and frequency of your power source match this rating.
•The Freeway server must be plugged into a grounded, three-wire power outlet.
Do not use an adapter that permits a three-wire electrical cord to be plugged into
a two-wire power outlet.
•Use appropriately rated extension cords or power strips only.
•To ensure proper cooling, always operate the Freeway server with its covers in
place. Do not cover or block any of the openings on the Freeway chassis. Do not
place the unit near a heater.
•Do not insert objects through openings in the Freeway chassis. Doing so could
result in a short circuit that might cause a fire or an electric shock.
•Do not modify the Freeway equipment in any way. Simpact, Inc. is not responsi-
ble for regulatory compliance of any Freeway communications server that has
been modified. Altering the Freeway enclosure in any way other than the installa-
tion of Simpact-provided options may invalidate Freeway’s safety certifications.

16 DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide
•Always unplug the Freeway AC power cord before removing the top or bottom
covers for servicing.
Français
Précautions d’emploi
Nous vous prions de suivre les précautions d’emploi suivantes au cours de l’installation
ou de tout entretien de votre serveur de communication Freeway:
•Respecter les avertissements et les instructions imprimées sur le serveur Freeway
et les appareils qui y sont associés.
•Vérifier les normes électriques indiquées sur une étiquette se trouvant sur le châs-
sis Freeway. Prière de s’assurer que le voltage et la fréquence de la source d’alimen-
tation sont compatibles avec ces normes.
•Le serveur Freeway doit être branché dans une prise de terre à trois broches. Ne
pas utiliser d’adaptateur permettant de brancher une prise mâle à trois broches
dans une prise de courant à deux broches.
•N’utiliser des rallonges, fils électriques ou parasurtenseurs qu’aux normes appro-
priées.
•Afin de refroidir correctement le serveur Freeway, utiliser seulement celui-ci avec
la housse en place. Ne pas couvrir ou bloquer les ouvertures du châssis Freeway.
Ne pas placer l’appareil Freeway près d’une source de chaleur.
•Ne pas insérer d’objets par les ouvertures du châssis Freeway. Ceci risquerait de
provoquer un court-circuit résultant en une décharge ou un incendie.
•Ne pas modifier l’appareil Freeway de quelque manière que ce soit. Simpact, Inc.
ne pourra être tenu responsable de toute infraction aux normes d’un serveur de
communication Freeway ayant été modifié. Toute altération de l’enveloppe Free-
way d’une manière autre que pour l’installation d’options fournies par Simpact
risque de rendre les normes de sécurité de Freeway invalides.

Safety Precautions
DC 900-1370E 17
•Toujours débrancher le fil d’alimentation en courant alternatif de Freeway avant
d’enlever la housse supérieure ou inférieure à des fins d’entretien.
Deutsch
Sicherheitsvorkehrungen
Vergewissern Sie sich, daß die folgenden Sicherheitsmaßnahmen bei der Installation
und Wartung des Freeway Kommunikations-Servers eingehalten werden:
•Lesen Sie die Anleitung und Sicherheitsregeln auf dem Freeway Server und auf
dem Zubehör.
•Die Voltspannung und Frequenz der von Ihnen verwendeten Stromquelle muß
mit den elektrischen Werten, die auf dem Freeway Chassis angegeben sind, übere-
instimmen.
•Der Freeway Server muß an eine geerdete, dreiadrige Stromquelle angeschlossen
werden. Bitte verwenden Sie keine Adapter, die den Anshluß dreiadriger Kabel an
zweiadrige Stromquellen ermöglichen.
•Benutzen Sie nur den Angaben entsprechende Verlängerungskabel oder Steck-
dosenleisten.
•Benutzen Sie den Freeway Server nur, wenn alle Abdeckungen intakt sind und die
vordere Scharniertür geschlossen ist. Blockieren Sie in keiner Weise irgendwelche
Öffnungen des Freeway Chassis, und positionieren Sie den Apparat nicht in der
Nähe einer Heizung.
•Stecken Sie keine Gegenstände durch die Öffnungen des Gehäuses; dies könnte
einen Kurzschluß hervorrufen, der einen Brand oder einen elektrischen Schlag
verursachen kann.
•Verändern Sie in keiner Weise das Freeway Zubehör. Simpact, Inc. ist nicht für
abgeänderte Freeway Kommunikations-Server verantwortlich, die demzufolge
den vorgeschriebenen Regeln nicht entsprechen. Jegliche Abänderungen der

18 DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide
Freeway Anlage, mit Ausnahme der Installation von Simpact-Sonderausstattun-
gen, können die Sicherheitsbescheinigung der Anlage ungültig werden lassen.
•Entfernen Sie immer das Freeway Stromkabel von der Stromquelle, bevor Sie die
oberen oder unteren Deckel zur Wartung abnehmen.
Italiano
Norme di sicurezza
Durante l’installazione e la manutenzione del server per le comunicazioni Freeway
seguire le seguenti norme di sicurezza:
•Seguire le avvertenze e le istruzioni stampate sul server Freeway e sulle altre unità
ad esso collegate;
•Controllare l’etichetta con l’indicazione del voltaggio elettrico sul telaio ed assi-
curarsi che voltaggio e frequenza della presa di corrente vi corrispondano;
•Il server Freeway deve essere collegato ad una spina con messa a terra, e con tre
fili. Non usare un adattatore che consente di collegare un filo a tre fili in una presa
a due;
•Usare solo fili e prese multiple con taratura appropriata;
•Per assicurare un raffreddamento adeguato usare sempre il server Freeway con il
suo relativo coperchio. Non coprire o bloccare nessuna delle aperture del telaio di
Freeway. Non collocare l’unità vicino a fonti di calore;
•Non inserire oggetti nelle aperture situate sul telaio di Freeway, perchè così
facendo si rischia di provocare un corto circuito, che può generare un incendio o
una scossa elettrica;
•Non modificare in nessun modo l’unità Freeway. La Simpact, Inc. non è respons-
abile della conformità alle norme di nessun server Freeway per le comunicazioni
che sia stato modificato. L’alterazione in qualsiasi maniera del telaio di Freeway,

Safety Precautions
DC 900-1370E 19
che differisca dalle opzioni di installazione fornite dalla Simpact, può invalidare le
garanzie di sicurezza;
•Prima di togliere il coperchio o la base per effettuare qualsiasi manutenzione,
togliere sempre la spina di Freeway.

20 DC 900-1370E
Freeway 1100/1150 Hardware Installation Guide
This manual suits for next models
1
Table of contents
Other Simpact Server manuals
Popular Server manuals by other brands

Sun Oracle
Sun Oracle Sun SPARC Enterprise T5140 Administration guide

DIGITAL YACHT
DIGITAL YACHT Aqua Wear WLN20 Installation and instruction manual

Compaq
Compaq 108164-003 - ProLiant - 800 Integration notes

Supermicro
Supermicro SuperStorage SSG-136R-N32JBF user manual

HP
HP Integrity rx2600 Information update

ClearCube
ClearCube A1010 Deployment guide