Sinbo SAH 6111 User manual

SAH 6111 AIR HUMIDIFIER
INSTRUCTION MANUAL
EN
RU

- 1 -
ENGLISH
SINBO SAH 6111 HUMIDIFIER
INSTRUCTION MANUAL
SAFETY MEASURES
* Before using the device, please, attentively read these instructions and keep them for
the whole operation period.
* Before switching on make sure that the voltage of the electric network corresponds
to the operating voltage of the unit.
* Place the unit on the flat, moisture-resistant surface. Distance from the walls should
be not less than 15 cm.
* Do not direct the nozzle of the unit at the wooden furniture, electrical appliances, books
and objects, which can be damaged by moisture.
* Do not place the humidifier in the places subjected to direct sun light, high temperatures,
near computers or other sensitive electronic appliances.
* Do not leave the unit unattended in closed rooms otherwise condensation can appear
on the furniture and the walls, that is why we recommend keeping the door of the room,
where the humidifier is used, half-opened.
* It is forbidden to use the device out of doors.
* Use only the removable parts which are supplied with the unit.
* Do not allow children to use the kettle as a toy.
* This unit is not intended for usage by children or disabled persons. This unit is not
intended for usage by children or disabled persons unless they are given all the necessary
instructions on safety measures and information about danger, which can be caused by
improper usage of the unit.
* Do not switch on the unit without water. Disconnect the unit from the power supply
when the water tank becomes empty.
* Do not use soda water or any perfume additives.
* Always unplug the unit and before taking the water tank out of the unit.
* Do not block steam outlets and provide that foreign objects do not get inside them.
* Do not immerse the unit, the power plug or the power cord into water or other liquids.
* Do not move or tilt the unit during its operation.
* Always unplug the unit and pour out water from the water tank during cleaning the
unit, if you do not use it.
* Unplug the unit before moving it to another place.
* Do not touch the power plug with wet hands.
* Before using the unit, closely examine the power cord and make sure that it is not
damaged. Do not use the unit, if its power cord is damaged.
* Do not dismantle the unit yourself, if any malfunction is detected, apply to the nearest
authorized service center.
* Regularly clean the unit; do not allow cracks to appear on the sprayer
FOR HOUSEHOLD USAGE ONLY

- 2 -
BEFORE USING THE UNIT FOR THE FIRST TIME
* Unpack the unit and remove the packing materials. Examine the unit for damages. Do
not switch on the unit if there are any damages in it.
Note: If the unit was subjected to negative temperatures, before switching it on for the
first time, keep it at room temperature for 30 minutes.
use the unit at +5°C - +40°C temperature, and relative humidity less than 80%.
Water temperature should not exceed +40°C.
Before switching on the unit, make sure that the voltage of the electric network corresponds
to the operating voltage of the unit.
Product Structure Diagram
1. Nozzle
2. Water Tank
3. Water Window
4. Tank Lid
5. Knob Switch
6. Engine base
7. Sponge
8. A›r Inlet Net
9. Power Cord
10. Water Slot
11. Atomizer Plate
Product parameters
Product name: Humidifier
Product model: SAH 6111
Rated voltage (V): AC220-240V ,50/60Hz
Rated power (w): 25W
Capacity (L): 4L
Complete machine dimension (mm): 196* 209*245mm

- 3 -
Product Usage
Remove the water tank Twist off the tank lid
Add water into the tank Twist back the tank lid
Put the tank back
1. Place the machine on the leveling table top, take down the water tank and unscrew
the tank lid at the bottom of water tank. Inject appropriate clean tap water or distilled
water, and then screw up the rotary knob.
2. Stably place the water tank on the engine base, and then inset the machine power
plug into the socket. Firstly ensure the working voltage of the machine must be consistent
with the service voltage before power on.
3. Open power switch/mist volume adjusting switch, then the power indicator light is lit
(green or blue). The machine is operated and the mist volume can be adjusted freely.
4. When the water level of the water tank is too low, the machine will be automatically
powered off and stopped operation, and the indicator light for water shortage is lit at the
same time (red). Please firstly turn off the power switch, or pull out the power plug, and
then refill water into the water tank.

- 4 -
Clean and care
Always switch off and unplug the unit before cleaning.
Hard water causes appearance of scale on the “sprayer” and in the operating chamber;
it leads to improper operation of the unit and appearance of white deposit on the interior
objects. To avoid it:
* Use boiled water or water, which stood for some time, water, purified by filter or distilled
water;
* Clean the operating chamber weekly;
* Change water in the water tank more often.
Weekly care
* Once a week carefully wash the water tank and the operating chamber with a neutral
washing liquid solution. After it rinse them thoroughly with water.
* Add 5-10 drops of the cleaning agent on the “sprayer” ; wait about 2-5 minutes. Use
the brush to remove the deposit from the surface of the “sprayer”.
Note:
* As a cleaning agent for the “sprayer” you can use substances for scale removal in
kettles.
* Do not immerse the unit into water or other liquids.
Storage
Before taking the unit away for storage, pour out water from the water tank (2) and from
the operating chamber (4), wipe the operating chamber (4) dry.
Do not store the unit with water in the water tank or if water remains in the operating
chamber.
Keep the humidifier in a dry cool place out of reach of children.
Troubleshooting
Failure: The operating indicator is not lighting, no steam formation.
Possible Causes: No voltage, no power supply.
Troubleshooting: Plug the unit.
Troubleshooting: Plug in another, properly operating device, to make sure that the socket
is in good operating condition.
Failure: The operating indicator is lighting red, no steam formation.
Possible Cause: There is no water in the water tank.
Troubleshooting: Fill the water tank with water.
Failure: ‘’Steam’’ has an unpleasant smell
Possible Cause 1: New device –it is normal

- 5 -
Troubleshooting 1: Unscrew the lid of the water tank, pour out water and leave the unit
for 12 hours in a cool dark place..
Possible Cause 2: Polluted or stagnant water
Troubleshooting 2: Unplug the unit, remove the water tank, pour out water, wash the
water tank and fill the water tank with boiled or distilled water.
Failure: Small intensity of ‘’steam’’ output
Possible Causes: Polluted ‘’sprayer’’
Troubleshooting: Unplug the unit and clean the sprayer.
Failure: Abnormal noise during operation of the unit.
Possible Cause: The unit is placed on the uneven or unstable surface.
Troubleshooting: Unplug the unit and even the body of the unit or move the humidifier
to another place.
NOTE:
Non-observance of rules for cleaning the unit from mineral deposits caused by hard
water may affect the overall performance of the unit. In this case clean the unit. If used
water is too hard, use household filters to purify water or mix tapping water with distilled
water in proportion 1:1.
GUARANTEE
Details regarding guarantee conditions can be obtained from the dealer from whom the
appliance was purchased. The bill of sale or receipt must be produced when making any
claim under the terms of this guarantee.
Warning:
1. This appliance is not intended for use by persons (including children)with reduced
physical sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
2. Children should be supervised to ensure that they do not play with the appliance.
3. If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
4. Unplug the appliance during filling and cleaning.
5. This appliance is intended used for household and indoor use only.







- 12 -

- 13 -
01-2019

Table of contents
Other Sinbo Humidifier manuals
Popular Humidifier manuals by other brands

Essick
Essick Bemis 527 300 Owner's care & use manual

CIGAR OASIS
CIGAR OASIS PLUS 3.0 quick start guide

Stulz
Stulz BNB Series Technical manual

GeneralAire
GeneralAire 5500 Installation & user manual

Condair
Condair Nortec GS Series Operation and maintenance manual

Levoit
Levoit Classic 300 Series user manual