Siterwell STW-W3320WU User manual

Instruction Manual
Door Sensor
Model number: STW-W3320WU
Thank you for your support
●Please read the instruction manual carefully before operating
●Please keep the instruction manual for future reference
Siterwell Technology HK Co.,LTD

Introduction
Door sensor is an intelligent security equipment that can transmit the Z-Wave
network which has particular frequency. In the Z-Wave network
communications, door sensor can be connected to any Z-Wave main
controller (ex, SiterOne tablet). The door sensor can send messages to the
Z-Wave main controller, and realize association with other devices through the
Z-Wave main controller. Different countries or areas, the radio frequency is
different. Inthecommunicationwiththe Z-Wave main controller, thedoor
sensor cansendmessages to the Z-Wave main controller,but it
cannotreceivemessages from the Z-Wave main controller. When alarm is
triggered, the door sensor sends messages to the Z-Wave main controller, the
Z-Wave main controller will displays the current status of door sensor, so the
door sensor can associate with other devices. Door sensor is battery
powered, is small and can be installed on the window or door easily. When the
door or window is open, the door sensor is triggered and linkage alarm
realized.
Technical Parameters
●Power: CR2x1
●Standby current: 1uA
●Battery life: 2 years
●Radio Protocol: Z-Wave
●Radio Frequency: 868.4MHz EU; 908.4MHz US; 921.4MHz ANZ; 869.2MHz
●Compatible with 300 series and 500 series
●Wireless distance:50m
●Operation temperature: 0-40℃
●Storage temperature: 0-60℃
●Size: Contactsensor main body (L x W x H): 70mmx20mmx20mm
Contactsensor deputy body (L x W x H): 40mmx11mmx11mm
Technical Information
●Install on the door or window.
●Battery powered.
●Easily install with screws or sticker.
●Associate with other devices through the gateway.
●Compatible with any Z-Wave network (ex, SiterOne tablet).
Product Configuration

Product List
Door sensor main body
1pc
Door sensor deputy body
1pc
Battery
2pcs
Screw
4pcs
Screw stopper
4pcs
Sticker
2pcs
Instruction manual
1pc

Add Door Sensor to Z-Wave Network
The door sensor can be added to the Z-Wave network by pressing the code
button.
1. Disassemble the door sensor main body and insert the battery. Make
sure the device is located within the direct range of the controller.
2. Set the main controller SiterOne into the adding mode (see mail
controller’s operating manual).
3. Quickly, triple click the code button, LED light will flash for 5 times.
4. Door sensor will be detected and added in the Z-Wave network.
5. Wait for the main controller to configure the sensor.
Remove Door Sensor from Z-Wave Network
1. Make sure the sensor is inserted with battery.
2. Set the main controller into the remove mode (see main controller’s
operating manual).
3. Quickly, triple click the code button, LED light will flash for 5 times.
4. Wait for the main controller to remove the sensor.
Restore Door Sensor to Factory Default
Reset will delete all information on the Z-Wave network or Z-Wave controller,
and restore the sensor to factory default settings.
1. Remove the cover of door sensor main body.
2. Make sure the sensor is inserted with battery.
3. Press and hold the reset button for 10 seconds, LED light will flash red
for 1 time.
4. Release the button.
Note: use the reset procedure only when the primary controller is missing or inoperable.
NOTE
When the Door Sensor is being restored to factory default settings, please
make sure the battery is inserted.
Installation Steps
●Door sensor Installation
●Battery Installation
Door Sensor Installation
●Option One
Disassemble the door sensor main body and take out battery, fix it on the door
with screws.
Disassemblethedoor sensordeputy body
andfixitonthecorrespondingdoor frameposition

●Option Two
Put the sticker on the bottom of door sensor to fix it on the wall
NOTE
When installing the door sensor, doorsensor deputy body must be installed
on the bulge side of the doorsensor main body.
Battery Installation
Tips
●When the door is closed, and the distance between the main body and the
deputy is less than 2cm, the Z-Wave main controller displays the door is
closed perfectly.

●When the dooris opened, the distance between the main body and the
deputy body is more than 2cm, LED light flash and door sensor sends
messages to the Z-Wave main controller,the Z-Wave main controller
displaysthe dooris openand alarms.
●Valid distance of door sensor is 2cm, so when install, please pay attention
to the trigger surface, it is triggered by point to point.
●Make sure of that door sensor is in the Z-Wave network.
LED status
1. When the door sensor is triggered, LED light flashes red for 1 times.
2. When the door sensor installs battery, LED light will flash red for 5
times.
3. Quickly, triple click the code button ,add the door sensor to the Z-Wave
network or remove door sensor from Z-Wave network , LED light
flashes red for 5 times.
4. Press on the code button for 10 seconds, the door sensor will be
restored to factory default settings, LED light flashes red for 1 time.
5. In the normal condition, the LED light keeps being off.
Associations
This has the effect that when the sensor is triggered, all devices associated
with the sensor will receive the relevant reports. Through an association the
sensor may control other Z-Wave network devices, e.g. the alarm device, wall
plug, lamp etc.
This Sensor supports 4 association groups. This has the effect that when the
sensor is triggered, all devices associated with the sensor will receive the
relevant reports. Through an association the sensor may control other Z-Wave
network device, e.g. a alarm device, wall plug, lamp etc. Every group can be
support to associated 5 devices max.
GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector)
status –
Open/Close. It enables the sensor to send reports and readings to Z-Wave
Controller or Z-Wave
Gateway whenever the sensor is triggered. This Group Support:
NOTIFICATION_REPORT
BATTERY_REPORT
SENSOR_BINARY_REPORT
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP 2 allows for sending control commands to associated devices such
as relay module,
lighting, etc. This association group is configured through the advanced
parameters no. 1 and 2.
This Group Support:
BASIC_SET.

GROUP 3 allows for Send Notification to associated devices in this group.
This Group Support:
NOTIFICATION_REPORT
GROUP 4 allows for Send Notification to associated devices in this group.
This Group Support:
SENSOR_BINARY_REPORT
Battery Usage Tips
Battery life of the door sensor is approximately 2 years at factory default
settings. The current battery level is displayed in the gateway. Red battery
icon means the battery needs replaced. In order to avoid tamper detection,
while replacing the battery, please disconnect the association of the door
sensor with other devices.
Note
Door sensor is battery powered. Using batteries other than specified may
result in explosion. Dispose of properly, please observe environmental
protection rules.
Advanced Configuration
1. Configuring the OFF Delay
This configuration parameter that can be used to adjust the amount of delay
before the OFF command is transmitted. This parameter can be configured
with the value of 0 through 65535, where 0 means send OFF command
immediately and 65535 means 65535 seconds of delay.
Function: On/Off Duration.
Parameter Number: 1.
Parameter Size: 2 Byte
Available Settings:0-65535 (in seconds, each 1s).
Default Setting: 30 (s)
2. Basic Set Level
Basic Set Command will be sent where contains a value when the
door/window is opened or closed, the receiver will take it for consideration;
for instance, if a lamp module received the Basic Set Command of which
value is decisive as to how bright of dim level of lamp module shall be.
Function: Basic Set
Parameter Number: 2
Parameter Size: 1 Byte
Available Settings:0, 1 - 99 or 255
0 – OFF, Alarm cancelling or turning a device off
1 - 99 or 255 – ON (Binary Switch Device)
Dim Level (Multilevel Switch Device)

Default Setting: 99
Command Classes
This Sensor(Door/Windows Detector) supports Command Classes as Below:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_WAKE_UP (V2)
* COMMAND_CLASS_NOTIFICATION (V4)
* COMMAND_CLASS_SENSOR_BINARY (V2)
* COMMAND_CLASS_CONFIGURATION (V1)
Guarantee
3. The Guarantee is provided by Siterwell Technology HK Co., LTD
(hereinafter “Manufacturer” ).
4. The Manufacturer is responsible for equipment malfunction resulting from
physical defects (manufacturing or material) of the device for 12 months
from the date of its purchasing.
5. During the Guarantee period, the Manufacturer shall remove any defects,
free of charge, by repairing or replacing.
6. In special cases, when the device cannot be replaced with the device of
the same type (e.g. the device is no longer available in the commercial
offer), the Manufacturer may replace it with a different device having
technical parameters similar to the faulty one. Such activity shall be
considered as fulfilling the obligations of the Manufacturer. The
Manufacturer shall not refund money paid for the device.
7. The guarantee shall not cover:
●mechanical damages (cracks, fractures, cuts, abrasions, physical
deformations caused by impact, falling or dropping the device or other
object, improper use or not observing the operating manual);
●damages resulting from external causes, e.g.: flood, storm, fire,
lightning, natural disasters, earthquakes, war, civil disturbance, force
majeure, unforeseen accidents, theft, water damage, liquid leakage,
battery spill, weather conditions, sunlight, sand, moisture, high or low
temperature, air pollution
●damages caused by malfunctioning software, attack of a computer
virus, or by failure to update the software as recommended by the
Manufacturer;
Siterwell Technology HK Co.,LTD

Table of contents
Other Siterwell Accessories manuals
Popular Accessories manuals by other brands

D-2 Incorporated
D-2 Incorporated JF-1A Installation & Safe Use Manual

Simrad
Simrad PI HEIGHT - DATASHEET REV A datasheet

Seiko
Seiko Oxford Crossword Solver ER3000 Operation manual

Alpina
Alpina 871125226555 quick start guide

ATEN
ATEN VS-0116 user manual

Smith's Heating First
Smith's Heating First Edge Pro Compact owner's manual

Hytronik
Hytronik HMW38/RF quick start guide

Hama
Hama 00176570 operating instructions

LEGRAND
LEGRAND Wattstopper PW-301 installation instructions

Pure Essential Oil Works
Pure Essential Oil Works Scentworks Majestic Sunset quick guide

Pepperl+Fuchs
Pepperl+Fuchs UC4000-L2-E7-V15 quick start guide

Romoss
Romoss sense 8P+ user manual