10
3.1 Control Panel
The control panel of the CQ350-PRO Mount is shown below:
Fig. 3.1
3.2 Panel Interface Components:
PART III : ELECTRONIC CONTROL INTERFACE
POWER: This is a connector from which the mount and the hand control get power
supply. To connect to a power supply, align the index on both the plug of the cord
and the outlet on the panel, and then insert the plug.Screw the knurled cap of the
plug on the connector to secure the plug on the panel.
POWER Switch: Turns on and off the power to the mount and hand controller.
USB: It provides a USB-to-Serial connection for controlling the mount.
HAND CONTROL: This RJ-45 8-pins outlet is for connecting a SynScan hand con-
troller or a SynScan Wi-Fi dongle.
AUTO GUIDE: This RJ-12 6-pins outlet is for connecting an autoguider. It is com-
patible with any autoguider with a ST-4 type interface.
LED: The LED beside the Autoguide port serves as a power-on/status indicator.
1. Steady on: Power voltage is normal.
2. Slow ashing: Power voltage is low; continuing to operate the mount may dam-
age the battery (if a 12V lead-acid battery is in use).
3. Fast ashing: Power voltage is extremely low; continuing to operate the mount
may damage the battery and the motor controller in the mount.
4. Intermittent one ash: The PPEC training routine has been triggered, but the
controller in the mount has not received the worm index signal and the correc-
tion-recoding has not started yet.
5. Intermittent two ashes: The PPEC training routine has been started and the
controller in the mount has received the worm index signal and started to record
the PE correction. When the intermittent two ashes stops, it means the PPEC
training has nished.
6. Intermittent, three ashes: Sidereal tracking with PEC is now enabled.