HT40MA Engine Water Heater User Manual Page 11 of 12
8CAUTIONS AND FAULT SOLUTIONS
Before starting the machine, ensure that all the air is exhausted out of the heater and it is topped
off with coolant. If water is used, please drain it off when ambient temperature is lower than 0ºC.
Otherwise, the remaining water will freeze, resulting in heater break. Using tap water or river water will
scale the surface of heating pipe and shorten the using life of the heater.
Corresponding antifreeze is recommended.
Heat resisting power line is recommended.
Earth line must be soundly connected to earth.
Drain valve: Can be opened or closed using hexagonal tools.
Unit: mm
Fig.9 –Drain Screw
Common Faults and Solutions:
1. Overheat protection:
a. Check the valve to assure whether it is opened and whether the heater is full of water;
b. Check whether the hosepipe has an obvious W-shaped or reverse U-shaped trend, and whether
there is an obvious hot and cold alternating area;
Solutions: Shorten the hosepipe length and optimize the hosepipe trend;
2. High water outlet temperature: under normal circumstances, the outlet temperature is about 70℃.
It occurs when the hosepipe is too long, both the inner diameter of the hosepipe and the inner
diameter of the fitting joints are too small, as well as the water flow is not smooth so that the heat
cannot be transferred properly.
Solutions: Shorten the hosepipe length, using the hose with an inner diameter of more than 20mm,
and the connectors with an inner diameter of more than 15mm.
3. Unable to reach the preheating temperature:
a. The heater power is not enough;
b. The cable of the power supply is too long and result in dividing resistance of the cable;
Solutions:
1. Replace the heater whose power matches the engine;
2. Shorten the power cable as possible and increase the cable diameter.