SOGEDIS 353 User manual

353-373-383 INNER DISPLAY
MARCH 2022
1
Using the Control Panel
1. Enables the setting of the freezer to be modified
and super freeze mode to be activated if desired.
2. Enables the setting of the cooler to be modified and
super cool mode to be activated if desired.
3. Freezer set value screen.
4. Cooler set value screen.
5. Economy mode symbol.
6. Super freeze symbol.
7. Alarm symbol.
1.2 Operating your Fridge Freezer
Once you have plugged in the product, all symbols will be displayed for 2 seconds and the
initial values will be shown as -18 °C on the freezer adjustment indicator, and +4 °C on the
fridge adjustment indicator.
1.2.1 Freezer Temperature Settings
• The initial temperature value for the freezer setting indicator is -18 °C.
• Press the freezer set button once.
When you first press the button, the previous value will blink on the screen.
• Whenever you press the same button, a lower temperature will be set (-16 °C, -18 °C, -20
°C, -22 °C or -24 °C).
• If you continue to press the button, it will restart from -16 °C.
NOTE: Eco mode gets activated automatically when the temperature of the freezer
compartment is set to -18°C.
1.2.2 Cooler Temperature Settings
• The initial temperature value for the cooler setting indicator is +4 °C.
• Press the cooler button once.
• Whenever you press the button, a lower temperature will be set (+8 °C, +6 °C, +5 °C, +4
°C, or +2 °C).
• If you continue to press the button, it will restart from +8 °C.
1.2.3 Super Freeze Mode
Purpose
• To freeze a large quantity of food that cannot fit on the fast freeze shelf.
• To freeze prepared foods.
• To freeze fresh food quickly to retain freshness.
Display and Control Panel
How to use
To enable the super freeze mode, press and hold the freezer temperature setting button
for 3 seconds. Once the super freeze mode has been set, the super freeze symbol on
the indicator will be lit and the machine will beep to confirm the mode has been
switched on.

353-373-383 INNER DISPLAY
MARCH 2022
2
Display and Control Panel
During Super Freeze Mode:
• The temperature of the Cooler may be adjusted. In this case, Super Freeze mode will
continue.
• Economy mode cannot be selected.
• Super Freeze mode can be cancelled in the same way it is selected.
Notes:
• The maximum amount of fresh food (in kilograms) that can be frozen within 24 hours is
shown on the appliance label.
• For optimal appliance performance in maximum freezer capacity, activate super freeze mode
3 hours before you put fresh food into the freezer.
Super freeze mode will automatically cancel after 24 hours or when the freezer sensor
temperature drops below -32 °C.
Demo mode:
Firstly the power is on, secondly within 1 minute user have to set the cooler 2 and push cooler
temperature button for 10 seconds. Then economy, super and economy sembol will blink during the
service mode. All functions can be adjusted to show how they are adjusted to the customer.

353-373-383 INNER DISPLAY
MARCH 2022
3
Air Flow Diagram
Blown : Cold Air
Returned: Hot Air
Cutaway view: Air Flow Direction

353-373-383 INNER DISPLAY
MARCH 2022
4
This model is double controlled product without any valve. When both cooler & freezer set
by user :
Mainboard controls both the cooler sensor & freezer sensor. When cooler part reach
requested value, if the freezer part haven’t reach the requested level; compressor
continues to run.
While freezer continue to cool down, with the help of the RDH (Ref. Defrost Heater ), cooler
will stay at constant value. When the freezer reach the requested value both compressor &
RDH will be stop.
Compressor
Condenser
Capillary Tube
Fin Evaporator
Serpentine Evaporator
Hot Gas
Pipe
Dryer
Refrigerant Cycle

353-373-383 INNER DISPLAY
MARCH 2022
5
Used Component
Resistance Values According To The Temperature Sensor (°C/Ohm Rates)
( For The Freezer Defrost and The Cooler Ambient Sensor)
45 °C/1kΩ -1 °C/6.2kΩ
35 °C/1.5kΩ -3 °C/6.8kΩ
30 °C/1.8kΩ -5 °C/7.5kΩ
25 °C/2.2kΩ -7 °C/8.2kΩ
19 °C/2.7kΩ -12 °C/10kΩ
14 °C/3.3kΩ -15 °C/12kΩ
10 °C/3.9kΩ -20 °C/15kΩ
5.5 °C/4.7kΩ -24 °C/18kΩ
1.5 °C/5.6kΩ -31.5 °C/27kΩ
0°C/6kΩ -35.5 °C/33kΩ
Sensor Resistance Values According To The Temperature (°C/Ohm Rates)
(For The Cooler Defrost Sensor)
45 °C/2.15kΩ-1 °C/17.1kΩ
35 °C/3.26kΩ-3 °C/19kΩ
30 °C/4.02k5Ω-5 °C/21.1kΩ
25 °C/5kΩ-7 °C/23.5kΩ
19 °C/6.53kΩ-12 °C/30.8kΩ
14 °C/8.23kΩ-15 °C/36.5kΩ
10 °C/9.95kΩ-20 °C/48.6kΩ
5.5 °C/12.3kΩ-24 °C/61.5kΩ
1.5 °C/15kΩ-31.5 °C/98kΩ
0 °C/16.3kΩ-35.5 °C/12.6kΩ

353-373-383 INNER DISPLAY
MARCH 2022
6
Service Mode
Entering service mode :
After the cooler temperature is set to 8, push cooler temperature button for 10 seconds.
• If there is a faulty situation, error code will be observed on screen. Otherwise nothing will be on the
screen.
• Buzzer will sound beep for 0.1 sec. each 5 sec. during service mode.
• Alarm icon will blink
In the Servıce mode;
- Starting up by pressing the cooler set button until 1 led lights up. (economy symbol will light)
The below components are checked;
Compressor
Defrost heater
Balance heater
Cooler Fan
Freezer Fan
Condanser Fan
- Manual defrost is done by pressing the cooler set button 2 times. (super symbol will light)
6 Led lights continuously and manual defrost started. When the defrost sensor 10 C,manual defrost
ends.
Mode can be canceled manually or automatically
Manual canceling; will be done by pushing REF button.
If manual canceling of this function is not performed in 30 min. service mode will be canceled.
Appliance will check if defrost is finished in this 30min. It YES, appliance will go on from previous set
values. But if defrost is not finished , appliance will go on defrost till it finishes and then go on from
previous set values.
- When the cooler set button is pressed 3 times, the instantaneous values of the sensor values can be
read. (super and economy symbols will burn together) Negative temperature values will be indicated
by blink.
THE VALUE OF THE NUMBER 1 SENSOR IS DISPLAYED IN THE FIRST TIME OF FUNCTION.
THE PREVIEW OF THE NEXT SENSOR IS SHOWED WHEN PRINTED IN ANY FREEZER BUTTON.
COOLER SENSOR INSTALLATION TEMPERATURE IS SHOWN IN FREEZER SET VALUE, "1" WRITER IN
COOLER VALUE INDICATOR.
FREEZER SENSOR INSTALLATION TEMPERATURE IS SHOWN IN FREEZER SET VALUE, "2" WRITER IN
COOLER VALUE INDICATOR
DEFROST SENSOR INSTALLATION TEMPERATURE IS SHOWN IN FREEZER SET VALUE, "3" WRITER IN
THE COOLER VALUE INDICATOR
ATTENTION OF THE SENSOR AT THE SIZE OF FREEZER SET VALUE IS SHOWN, THE COOLER VALUE
INDICATOR "4" WRITER
SERPANTINE SENSOR HEAT TEMPERATURE IS SHOWN IN FREEZER SET VALUE SEGMENT, "5"
WRITER IN COOLER VALUE INDICATOR
WHEN PRIMING THE 5TH BEFORE PRINTING FREEZER BUTTON
MODE OF THE MODE OF THE COOLER BUTTON.

353-373-383 INNER DISPLAY
MARCH 2022
7
Service Mode
To cancel Service Mode : You can use same method as entering the Service Mode.
After the cooler temperature is set to 8, push cooler temperature button for 10 seconds.
Sensor Faults;
Component defect on display
DEFECT TYPE FREEZER SET VALUE COOLER SET VALUE
Compressor Defect
E06
Defrost Heater
Defect E 07
Low voltage error on display
DEFECT TYPE FREEZER SET VALUE COOLER SET VALUE
Low
voltage E 08
Cooling error on display
DEFECT TYPE FREEZER SET VALUE COOLER SET VALUE
LF E09
LC E10
HC E11
SENSOR FREEZER SET VALUE COOLER SET VALUE
(
1) Freezer (Short-Open) E 01
(
2) Refrigerator (Short-
Open)
E02
(
3) Defrost (Short-Open) E 03
(
4) AT sensor E 04
(5) RDH Sensor E 05

353-373-383 INNER DISPLAY
MARCH 2022
8
Special Programs
Freezer Defrost Program
•According to the conditions of usage, the defrost might be activated after the min
compressor running time; 8 hours or max total time; 55 hours. Below matters are also
effected;
•Consisted ice amount,
•Door open-close,
•Sudden usage variance,
•Cooler sudden temperature rise,
When the refrigerator works on first time;
If the cooler compartment defrost sensor and the freezer compartment defrost sensor are
hotter than -5°C, the test system works automatically. These below components are tested
automatically every 5 seconds.
The compressor and freezer fan motor starts and stops after 5 seconds.
The defrost resistance stars and stops after 5 seconds.
The cooler defrost resistance starts and stops after 5 seconds.
The DC Radial Fan starts and stops after 5 seconds.
After these steps, the system waits 5 minutes and then it will switch normal mod.
There are three types of sensors. They are cooler, freezer defrost, cooler defrost sensors. Cooler and
freezer defrost sensors have the same features but their cable length is different. The resistance
values of all sensors decrease when the temperature values of the sensors increase. For example,
the resistance value that is 33 kΩ in the -35.5 ºC goes down to 1kΩ in the 45 ºC and therefore the
ambient temperature should be considered while the sensor is being checked. If the ambient
temperature is 25 ºC, the measuring device shows about 2.2kΩ (if ntc sensor is steady).
NTC Sensor
Cooler Defrost Program
The cooler defrost and the freezer defrost are operated parallel except those below.
If the cooler defrost sensor does not feel 5°C three times during a particular period of time.
•Defrost will be activated after the refrigerator works max 9 hours. According to the
conditions of usage, the defrost might be activated (due to mentioned those below) after
the compressor works min 5 hours.
•Consisted ice amount,
•Door open-close,
•Sudden usage variance,
•Cooler sudden temperature rise,

353-373-383 INNER DISPLAY
MARCH 2022
9
Special Programs
In Case of Power Cut
•All regulated parameters and functions are kept in memory when the power cut.
• When the electricity comes, if the defrost sensor temperature is lower than -5 ºC the
compressor works 5 minutes later. If it is higher than -5 ºC.
Other Features
Warnings : The door open warning is active 2 minutes later and it alarms.
Door Direction : It is possible to reverse the door.
Gasket : It is possible to change the gasket.
Freezer Defrosting Time
The Defrost is disabled when the defrost sensor temperature feels 8ºC.If defrost time
passes 37 minutes, defrost completing temperature will be rise to 15ºC.
The cooler defrost and the freezer defrost are operated parallel except those below. The
cooler defrost will not work if the freezer defrost stops.
The defrost process stops when the defrost sensor temperature feels 7ºC. At the low
ambient temperature or when the compressor stops; to balance, defrost stops when the
defrost sensor temperature feels 15⁰C. But if the defrost time or the compressor stopping
time goes over 6 hours, the resistance will be stopped.
Compressor delay: First, the defrost process ends, the system waits 5 minutes, just after that
the compressor is active.
Cooler Defrosting Time

353-373-383 INNER DISPLAY
MARCH 2022
10
Probable Faults
Unsufficient cooling
Is the appliance too close to wall or
heat sources
(stove, central heating,
oven, cooker etc.
)?
It should be placed min 50cm
distance from heat sources and
min 5 cm from electric
al ovens.
Is the ambient temperature
high?
Raise the thermostat value
.
Check whether putting the hot foods
in the refrigerator?
Put the foods
after get cold.
Is there any gas leakage in refrigerant
system?
Check
all welding points in the
system.
The foods in the
cooler
compartment are
freezing.
Were the foods placed close
to
cooling air outlet
?
Please do not block air
outlets
Is the cooler
thermostat value high ?
Is there any hot foods close to the
cooler sensor?
Decrease the cooler thermostat
value and
do not put hot things
close to the sensor.
Are there any
sweating or icing?
Were t
he liquid foods in the closed
containers?
Put th
e liquid foods into the
closed containers.
Were t
he hot foods put into the
refrigerator?
Put it into
after getting cold.
Was
the refrigerator door opened?
Do
not leave the refrigerator
door open and do not often
open or close.
Abnormal
Noise
Is
the appliance on the flat surface?
The floor should be straight and
balance the refrigerator with the
help of the adjustable feet.
Is the compressor feet loose
Fix it.
Is the condenser
or fan stationary
normal?
Fix it.
Do the capillary tube or all other
tubes touch any where?
Fix it.

353-373-383 INNER DISPLAY
MARCH 2022
Changing The Door Swing Direction to Right Hand
Hold the top hinge cover and
remove it toward that direction. Unscrew the screws fixing the top hinge
and remove it.
Displace the top door.
Unscrew the two screws fixing
the middle hinge and remove it.
Remove the hince cover cap and
assembly right side.

353-373-383 INNER DISPLAY
MARCH 2022
Changing The Door Swing Direction to Right Hand
Displace the bottom door. Unscrew the bottom hinge screws.
Unscrew the adjustable foot.
Screw the bottom hinge to the left bottom
side of refrigerator. Screw the adjustable
foot there.
Unscrew the bottom hinge pin and
screw it to other hole.

353-373-383 INNER DISPLAY
MARCH 2022
Changing The Door Swing Direction to Right Hand
Unscrew the two screws fixing stopper
and stopper support plate under the bottom
door. After that screw the other side.
Replace the top bushing and the
top bushing cap at the bottom door.
Remove the support plastic and then metal stopper placed under the upper door. Then
re screw these parts to the other side symmetrically.
(remember the screw for the metal part must be screwed to the hole which is closer to
the bushing). Do not use cordless screwdriver for these screws.

353-373-383 INNER DISPLAY
MARCH 2022
Changing The Door Swing Direction to Right Hand
Place the bottom door and rotate
the middle hinge by 180º. After that,
Screw to the right side on the middle sheet.
Remove the middle hinge cover and then
screw the screw on the side panel
and assemble to the right side panel
Place the top door to the middle hinge and then connect the display connector and
screw the top hinge to the top panel. Place the top hinge cover.

353-373-383 INNER DISPLAY
MARCH 2022
15
Removing and Chancing The Mainboard
Picture-1
1. Unscrew the screws which are fixing the main board cover. (Pic-1)
Picture-2
2. Pull the mainboard slightly forward and disconnect all the connectors and then replace
it. Finally, place the mainboard cover and screw it. (Pic-2)
CAUTION: The plug must
be pulled out before the
mainboard group is
removed.

353-373-383 INNER DISPLAY
MARCH 2022
16
Removing- Assembling LEDs and LED’s Covers
2. Remove the led strip light from its
housing. (Pic-2)
3. Disconnect the connector and change the
led light strip. (Pic-3)
1. Stick a tape to protect plastic. Insert a flat
screwdriver into the gap and remove the cover.
(Pic-1)
Picture-1
Picture-2 Picture-3
SIDE LED (Optional-2)

353-373-383 INNER DISPLAY
MARCH 2022
17
Removing- Assembling LEDs and LED’s Covers
4. First, place the bottom point of the led light strip
and then place towards other side.(Pic-4)
Picture-4
Picture-5
5. Reassemble the led cover. (Pic-5)

353-373-383 INNER DISPLAY
MARCH 2022
18
Removing- Assembling LEDs and LED’s Covers
1. Remove the led cover by pulling forward and disconnect the connector.
TOP LED (Optional-2)

353-373-383 INNER DISPLAY
MARCH 2022
19
Removing The Cooler Multi Flow
Picture-1
1. Remove the cooler glass
shelves and the chiller.
2. Remove the screw caps by using a flat
screwdriver and screw the screws.
Flex the multi flow by holding the fan cover and remove it.
Disconnect the connector after removing the multi flow.
Picture-2
Picture-3 Picture-4

353-373-383 INNER DISPLAY
MARCH 2022
20
Removing The Cooler Multi Flow Fan Motor
1.Remove the fan cover by flexing the fan cover detail and then remove the fan motor
by flexing the fan motor rubbers. (Pic-1/ Pic-2/Pic-3)
Picture-1 Picture-2 Picture-3
2. Place the rubbers to the fan motor. After that, first place the bottom two details of
the fan motor and place the top two details by pressing-flexing it. (Pic-4/ Pic-5/Pic-6)
Note : The fan motor cable outlet should be at the top-left corner of it.
3. After the connector is connected, place it by flexing it and then reassemble the multi
flow by screwing.
Picture-4 Picture-5 Picture-6