►Product specifications
Model KJ-8000
Oxygen making mode VPSA mode
Inhalation method Nasal inhaler
Oxygen concentration
* flow
About 35% ~ 55% , 1L/Min
Measurement environment:
20 °C /normal pressure, 60%
RH / relative humidity
Spray rate
Working air flow
Working pressure range
Power supply
Negative ion About 300,000/
(electronic radiationtype)
Noise About 45dB away from the host
1 meter
Host weight
Host size 210mm(L) x 75mm(W) x 295mm(H)
About 1.88 kg (host only),
Gross weight: 2.4kg

The oxygen tube 1 set
INSTRUCTION MANUAL
HEA LTHY OXY GEN ME TER
INSTRUCTION MANUAL
HEA LTHY OXY GEN ME TER
Instruction manual 1 set
List of goods
Main unit 1 set
Power adapter 1 set

Name of each part
Oxygen model
Mode of spraying
Anion releasing/LED lamp
Molecular sieve change
notification lamp
Decorative lantem
Power switch button
press the button to turn
on or off the machine
automatic shutdown
after 40 minutes
Oxygen outlet
Atomizing pressure gas
Cooling
Power interface
Rubber foot
Intake (below)

►Use description
1. Switch mainframe:
(1) Plug the power adapter into the power outlet.
(2) Plug the adapter output plug into the rear case power jack.
(3) Press the “Start up Switch” button, then the white light will appear
around the “Start up Switch” button, and the host will start.
(4) The LED decorative light on the front of the main unit lights up, the
default function of the main unit is oxygen mode, and the oxygen outlet
starts to release oxygen.
(5) The host automatically stops after 40 minutes of continuous use.
Press the “Start Switch” button three times to terminate the host operation.
Press the button again to start the host work.
2. Oxygen making function:
Press the "start switch" button to switch the function key to the oxygen
production mode.
Start-up default for oxygen mode, oxygen mode output flow of 1L,
oxygen concentration of 35% - 55%, this function can not be used for
medical treatment purposes.
(1) insert the plug of the oxygen tube into
the oxygen outlet below the main engine.
(2) please plug the oxygen tube tightly into the oxygen outlet.
(3) hang the oxygen tube on the head.
(4) please put oxygen nozzle in the nose direction. The effect of
oxygen delivery within 5cm is better.
3. Atomization function:
Press the “Start Switch” function key to switch to the fog mode.
(1) Use the spray function with the spray can set (atomization kit).
(2) Open the lid and add the specified therapeutic medication using an
eyedropper or a designated standard container.
(3) Connect the connecting tube to the air inlet connection of the
atomizing cup.

(4) After turning on the power switch, press the start switch to start
running the machine, press the start switch again to switch to the fog
mode.
(5) Press the power switch again to switch to negative ion purification
mode.
(6) Press the power switch again to implement the shutdown mode,
and all indicators are off.
4. Method of using oxygen molecular sieve:
(1) What is an "oxygen molecular sieve"?
The oxygen content in the air is about 20.9%, and the nitrogen content
is about 79.1%. The molecular sieve contains ore, which adsorbs nitrogen
in the air to separate nitrogen and oxygen, thereby generating high
concentration of oxygen.
(2) Molecular sieve replacement period.
Molecular sieves that separate nitrogen and oxygen from the air have a
service life and need to be replaced periodically.
The life of molecular sieves is affected by the frequency of use and the
environment (air temperature, humidity, etc.).
After continued use after the service life, the oxygen concentration and
flow rate produced will decrease.
The timer built in the main unit manages the use time of the molecular
sieve, and the replacement time will be notified in time.
When the cumulative use time exceeds the default cumulative use time
of 1000 hours or more than a year from the initial use, the red light at the
text "EX" above the front of the host will light up. Please replace the
molecular sieves as soon as possible.
you oxygen.
►Effective oxygen absorption method
Insist on oxygen for more than 20 minutes every day, and the effect is
constant.
There is no specific time period, and you can arbitrarily choose the
time like to absorb

►Maintenance method
1. Host maintenance method
The dirt on the main unit can be wiped gently with a soft rag.
2. Nasal oxygen tube maintenance method
Gently wipe the oxygen outlet of the nasal oxygen tube with an
alcohol-based paper towel.
3. Filter maintenance method
(1) Remove the cover under the air inlet.
(2) Remove the filter (sponge, wool felt pad) and
wash it with water.
(3) After fully drying the filter, the installation
can continue to be used.
(4) Please maintain the filter once a month.
Warning
1. Do not use detergents, volatile oils, water, alcohol, etc., which may
cause cracks or discoloration.
2. Please do not use the hot air of the hair dryer to dry, can cause
deformation or malfunction.
3. When not in use for a long time, please let the machine run for 30
minutes once a week, helps maintain zeolite quality.
4. Do not wash the main unit and power adapter with water.
Intake(below)

5. Please do not use this product near fire or when you are smoking.
►Package:
1. Oxygen concentrator*1
2. Nasal oxygen tube*1
3. The power adapter*1
4. Atomizing tube*1
5. User's Manual*1
If you have any questions, please contact the store customer
service staff at the first time. Thank you!
Table of contents
Popular Oxygen Equipment manuals by other brands

C-Aire
C-Aire FreeStyle Comfort Technical manual

dideco
dideco D902 LILLIPUT 2 ECMO Instructions for use

Eclipse
Eclipse RatioMatic 1000 user manual

Emerson
Emerson Dissolved Oxygen Sensor Model 430 DO instruction manual

John Bunn
John Bunn JOHN BUNN JB0150-085 instructions

AirSep
AirSep Topaz instruction manual