1-1 (E)
BKP-7311 IM
AD
CN1 CN2
RV2231 RV2131 RV2031 E2031 E1781
E3071
TP3071
TP2231
TP2131 TP2031
RV3541 RV3351
TP3352TP3351
S1601
RV3211
RV3213
RV3354 RV3355
TP3542
TP3541
RV3544
RV3545
RV3214
TP3211
E3211
TP1991
TP1992
TP2742
TP2743
E2801 TP2741
TP1781
RV2771
TP2694
TP2691
TP2402
S2961
S2963
S2962
CN2032
E2441
TP2401S2441
TP2693
TP2692
TP1601
E2691
RV1381
CN3
RV1021 RV821 RV581
RV371
RV1181
S2442
(CN2541)
RV2541
TP2542
TP2541
RV2032
RV2132
RV3212
RV3352 RV3542
RV2232
S1603 S1602
-12-5 +5+12
CAUTION SDI CABLE
OUTPUT
A B C YB-YR-Y
BLACK
BALANCE RETURN
B&W COLOR
CHU RET1
/
RET2
LINE SELECT
RET1
/
RET2
RET3
/
RET4
YB-YR-Y
ANALOG
BLACK
BALANCE
ON
OFF ON
OFF
ON
OFF
ON
Section 1
Installation
1-1. General
BKP-7311 is the board kit that has a function of color
corrector and D1 format serial digital output. When this
board kit is installed into CCU-700A/CCU-700AP Camera
Control Unit, BVP-700/700P system can operate in D1
format serial digital system.
1-2. Function of Switches on AD Board
.S1601 (TEST ON/OFF)
Turn on when perfoeming the adjustment of analog
signal system for AD-117 board.
(Refer to Section 2 “Alignment” of the maintenance
manual.)
Factory-setting : OFF
.S1602 (CHU RET1/2 LINE)
Selects an output signal to be output to viewfinder, when
selecting the RET1/RET2 switch of BVP.
The output signal is as follows.
S1602/AD-117 RET SW/BVP Output signal for VF
RET1/RET2 RET1 RET1
RET2 RET2
RET3/RET4 RET1 RET3
RET2 RET4
Factory-setting : RET1/RET2
.S1603 (Digital RET BW/COLOR)
Selects B&W or COLOR as the DIGITAL RET signal
when DA-101 board (BKP-7312) is installed in CCU.
Factory-setting : COLOR
.S2442 (SDI ON/OFF)
Turn off when performing the adjustment of SDI Free-
Run frequency.
(Refer to Section 2-5-1 “SDI Free-Run Frequency
adjustment”of the maintenance manual.)
Factory-setting : ON
.S2961 (SDI TEST ON/OFF)
Turn on to output a test signal which is selected by
S2962 at SERIAL OUTPUT connector of CCU.
Factory-setting : OFF
.S2963 (REMOTE ON/OFF)
Selects an output signal at SERIAL OUTPUT connector
of CCU.
ON : Outputs test signal which is selected by S2962
OFF : Outputs COLOR-BAR signal from VA-156
which is analog-to-digital converted in AD
board.
Factory-setting : ON
.S2962 (D1 BAR MODE)
Selects the TEST signal to be output at SERIAL OUT-
PUT connector of CCU.
S2962 TEST SIGNAL
__
__
_1__
__
_2__
__
_3
OFF OFF ON 75% COLOR BAR
ON OFF ON 100% COLOR BAR
OFF ON ON BLACK BURST
ON ON ON MULTI BURST
– – OFF WORST PATTERN
n
S2962-4 is not used.