Application and
Installation Guide
Model CRDV/S
Dimensional Data
6 FT CORDSET
120 VAC WITH
WALL PLUG
3.52
0.68
PORT
3.50
2.47
3.02
EXPLODED VIEW
Application and
Installation Guide
Model CRDV/S
Applications
Warranty Information
Solenoid valves and all other products manufactured by Spartan are warranted by Spartan to be free from defects in material and work-
manship for a period of 1 year from the date of purchase. Spartan's obligation under this warranty is limited to repair or replacement of the
defective product or refund of the purchase price paid solely at the discretion of Spartan and provided such defective product is returned to
Spartan freight prepaid and upon examination by Spartan such product is found defective. This warranty shall be void in the event that the
product has been subject to misuse, misapplication, improper maintenance, modication or tampering. This warranty is expressed in lieu
of all other warranties, expressed or implied from Spartan Scientic, Inc., representatives or employees.
Excessive use of pipe sealant can cause clogging and leakage. Please follow ASME standards for applying pipe sealant and tape. Do
not use media, voltage or pressures other than that recommended by Spartan Scientic Inc. as valve malfunction could result. Misuse or
misapplication of Spartan solenoid valves could cause serious bodily injury or property damage.
Caution
Technical Data
CRDV/S
CRDV/S
CRDV/S
CRDV/S CRDV/S
CRDV/S
Function: 2-Way, 2-Position; Inlet Pilot Diaphragm;
Normally Closed
Port Size: 1/2" NPT
Orice Sizes / 12.5mm /
Flow Factor: 2.45 Cv
Pressure Range: 0 - 180 psi
Temp. Range: Fluid max.: 60°C
Dry Range: Ambient +10° to +50°C
Note: This device is not recommended for
use in below freezing temperatures
Response Time: 20-80 ms Complete Cycle
Media: Air, emulsion, gas, water
(contact factory for compatibilities)
Environment IP65 (IEC 144), NEMA 4
Protection: Dust-tight and water resistant
(with electrical connector)
Mounting: On pipe or #8 - 32 mounting holes on
valve base
Wetted Materials: Operator: 400 Series Stainless Steel
and Brass
Orice Seals: FKM
(others available on request)
Shading Ring: Copper
Springs: 300 Series Stainless Steel
Valve Body: Glass-Filled Nylon
Coil Data: Duty Cycle: Continuous
(within specications)
Encapsulation: Glass-Filled Nylon
Insulation: Class F
Power Rating: 8.5 VA
Voltage: 120 VAC 50/60 Hz
Voltage tolerance: +/- 10% Nominal
Winding: Class H
Transient
Suppression: MOV
Cable: 6 ft. Cord with grounded wall plug
Packaged Weight: 1.1 lbs.

P.O. Box 9792
●
Boardman, Ohio 44513
PH: (855)629-4648
●
Fax: (330)758-3314
www.spartanscientific.com
P.O. Box 9792
●
Boardman, Ohio 44513
PH: (855)629-4648
●
Fax: (330)758-3314
www.spartanscientific.com
Installation How It Works
Application and
Installation Guide
Model CRDV/S Application and
Installation Guide
Model CRDV/S
2/2 WAY SHUT
OFF VALVE
CRDV/S
UNIT OUTLET TO DRAIN
OR SEPARATOR
6FT CORDSET
2/2 WAY SHUT
OFF VALVE
OPTIONAL #8-32
THREAD FOOTPRINT
6FT CORDSET
CRDV/S
UNIT
OUTLET TO DRAIN
OR SEPARATOR
OPTIONAL #8-32
THREAD FOOTPRINT
2/2 WAY SHUT
OFF VALVE
2/2 WAY SHUT
OFF VALVE
1. The CRDV/S is an automatic device and will cycle with the presence of water at the inlet and one time initially to indicate
that it is working. It is important to make all pressure connections prior to making electrical connections as the CRDV/S
automatically cycles without warning.
2. Drain the tanks, dryers, coolers or any device that is the producer of the condensate of any water and air pressure prior to
CRDV/S installation.
3. It is necessary to mount the CRDV/S below the vessel it is draining, as the condensate is gravity fed to the inlet port of the
CRDV/S.
4. Connecttheunit’sinletporttothecondensateline;followtheowarrowontheCRDV/S,(itisadvisabletoinstallaballvalve
or ball valve strainer to facilitate future service of your CRDV/S).
5. Connect the exhaust port to an air-oil separator or equivalent device.
6. Connect the wall plug to a convenient wall connection and you are ready to go.
NOTE: Spartan Scientic strongly recommends the use of a strainer prior to the inlet of the CRDV/S to lter out any
particulate. If no strainer is used particulate build up may occur causing a minor leak. To remedy this condition, it is necessary
to apply a sustained purge of 5 to 10 seconds to clear the debris.
HORIZONTAL MOUNTING VERTICAL MOUNTING
OPEN POSITION CLOSED POSITION
Normal Mode:
WhentheCRDV/Sisrstconnectedtoelectricity,theunitgoesintoaoneminuteinitializationmodeduringwhichtheoverride
button is non-functional and the following sequence occurs:
L1LED=Power(grn)/Valve(yel)
L2LED=Detect(grn)/Alarm(yel)
L1red/grn L2red/grn @1Hz(chatterwarning) for10seconds.
L1red/grn L2off @10Hzandvalvechatters for2seconds
L1 grn L2 off Pause for 3 seconds
L1yel L2off Valveon(shortvaporpurge) for1second
L1grn/red L2off @1Hz (sensorwarmup) for35seconds
L1 grn L2 off – unit ready for /use.
Aftertheinitializationmode,theunitwillimmediatelyenternormalmode.
Ascondensateisgenerated,thewaterandefuentfallsbygravitythroughthepipingtotheinletoftheCRDV/S.
AshortvaporpurgeoccurscontinuallytoinsurethereisnotrappedairinthelinestopreventwaterfromreachingtheCRDV/S.
The time interval between vapor purges is automatically adjusted based on the need and can vary between 2 minutes and 2 hours.
NothingelsehappensuntiltheCRDV/Ssolid-statesensorsensesthepresenceofcondensate.Atthattimetheelectronicssends
thesignaltoenergizethesolenoidvalve,whichopensandexhauststhecondensatefromthepneumaticsystem.Aftera1second
purgeintervalthevalvede-energizesandthesensornolongersenseswaterattheinletport.TheCRDV/Sthengoesdormantfor
aminimumof35secondsafterwhichtheunitwillstandreadytopurgecondensateagain,onlywhenitissensed.Ascondensate
once again builds up, the sensor senses the presence of condensate and the purge cycle continues.
High Flow Mode:
If, during normal mode, there is a high production of condensate, the CRDV/S function will change to accommodate the
increasedneedtoremovewaterfromthesystem.Asinnormalmode,theCRDV/Sremainsdormant,sensingforcondensate.
If there is a high amount of condensate at the inlet port, so much so that the 1 second purge will not remove it all from the port,
the CRDV/S “learns” and opens for a 2 second purge interval. The unit then goes into a 35 second wait cycle after which the
CRDV/S, if it continues to sense condensate, continues to re-cycle adding 1 second to the purge interval each time. The sensor
goes into alarm mode when the purge interval gets to 6 seconds. During alarm mode the CRDV/S repeats the purge cycle adding
1 second to the purge interval each time until the sensor stops sensing condensate. When the sensor runs free of condensate the
CRDV/S returns to normal mode. If during alarm mode the purge interval gets to 16 seconds, the unit will enter an emergency
shutdownmodetoconserveairandwillashbothLEDsata1Hzrateuntilpowerisremovedandreapplied.
Electrical and Manual Override:
The CRDV/S is equipped with both a manual override and an electrical override. The manual override is the green push button
found on the side of the valve at the back of the unit. Pressing this button allows for drainage of the condensate line without the
needforelectricity.Theelectricaloverrideisabuttonfoundatthefrontoftheunitwhichenergizesthesolenoidanddrainsthe
condensate line. Both overrides are momentary contact, spring return.
One 1 second purge cycle every 24 hours
Thereisone1secondpurge/chattercycleevery24hoursjusttoensurethatthecondensatelinesareclearandefuentisowing
to the CRDV/S.
Indicator Light Chart
Other spartan scientific Control Unit manuals
Popular Control Unit manuals by other brands

Burkert
Burkert 2103 Series operating instructions

Texas Instruments
Texas Instruments TMDS64DC01EVM user guide

Apollo Valves
Apollo Valves DC4A Installation, operation & maintenance manual

Wiznet
Wiznet WIZ6000 manual

Eaton
Eaton Moeller SL7-CB Series Instruction leaflet

Fisher
Fisher Type 92B installation guide

RYO
RYO Optodist Assembly instructions

Siemens
Siemens SIDOOR AT40 System manual

M-system
M-system R3-NC3 instruction manual

Festo
Festo VZWF-...-M22C series operating instructions

Belden
Belden Lumberg Automation Lumberg Automation 0980 ESL 811-EIP... Technical manual

Agilent Technologies
Agilent Technologies E1476A user manual