Spirit Healthcare TEE2+ User manual

Large LCD No Coding Intuitive Meal icons
Blood Glucose Monitoring System
Owner’s Booklet

Thank you for choosing the TEE2 Plus Blood Glucose Monitoring
System. The system provides you with rapid and convenient
blood glucose in vitro (i.e., outside the body) diagnostic
monitoring. You can obtain accurate results in just 5 seconds
with a small (0.5 µL) blood sample.
Test results can be sent to a smartphone through Bluetooth®
wireless connection.
Welcome to the TEE2 Plus
Blood Glucose Monitoring System
Bluetooth wireless technology is used by some smartphones and
many other devices. TEE2 Plus Meter uses Bluetooth wireless
technology to pair* and to send your glucose results to a
smartphone.
The TEE2 Plus Meter is designed to work with the SmartLog™
mobile app. When using the TEE2 Plus System, we suggest you
pair your TEE2 Plus Meter with your smartphone and track your
results.
Bluetooth®wireless technology
* The process of creating a connection between two Bluetooth
devices. An auto-generated passkey has to be exchanged
between the two devices. Once the devices are paired, they will
automatically communicate with each other when the
Bluetooth feature is activated.

The Bluetooth®word mark and logos are registered trademarks
owned by Bluetooth SIG, Inc. and any use of such marks by
i-SENS, Inc. is under license. All other trademarks and trade
names are those of their respective owners.
WARNING:
Turn off the Bluetooth feature in areas where the use of
wireless devices is restricted, such as hospitals, some healthcare
professional offices, and aeroplanes.
Trademarks
Note:
The SmartLog mobile app may not be compatible
with all smartphones.


Information
Important Information: Read This First! ------------------------------------------------------- 6
Specifications ---------------------------------------------------------------------------------------- 8
TEE2 Plus Blood Glucose Monitoring System ------------------------------------------------ 9
Inserting or Replacing the Batteries ----------------------------------------------------------- 10
Caring for Your System ---------------------------------------------------------------------------- 11
TEE2 Blood Glucose Test Strip ------------------------------------------------------------------- 12
TEE2 Plus Blood Glucose Meter ----------------------------------------------------------------- 14
TEE2 Plus Blood Glucose Meter Display ------------------------------------------------------- 15
Preparation
Setting Up Your System --------------------------------------------------------------------------- 16
Setting Up Bluetooth ---------------------------------------------------------------------------- 17
Adjusting the Date and Time ------------------------------------------------------------------ 20
Setting the Sound On/OFF --------------------------------------------------------------------- 22
Turning on the Strip Expiration Date Indicator -------------------------------------------- 23
Turning on the Hypoglycemia (HYPo) Indicator ------------------------------------------ 24
Setting the Strip Expiration Date Indicator ------------------------------------------------ 25
Checking the System ------------------------------------------------------------------------------ 26
Control Solution Testing ------------------------------------------------------------------------ 27
Comparing the Control Solution Test Results --------------------------------------------- 30
Testing
Using the Lancing Device ------------------------------------------------------------------------ 31
Preparing the Lancing Device ---------------------------------------------------------------- 32
Preparing the Meter and Test Strip ---------------------------------------------------------- 34
Applying Blood Sample ------------------------------------------------------------------------- 34
Discarding Used Lancets ----------------------------------------------------------------------- 38
Alternate Site Testing ------------------------------------------------------------------------------ 39
HI and Lo Messages -------------------------------------------------------------------------------- 42
Target Blood Glucose Ranges ------------------------------------------------------------------- 43
Transferring Test Results Using Cable --------------------------------------------------------- 43
Additional Functions
Meter Memory --------------------------------------------------------------------------------------- 44
Viewing Averages Stored in Memory -------------------------------------------------------- 44
Viewing Test Results Stored in Memory ---------------------------------------------------- 47
Setting the Alarm Function ---------------------------------------------------------------------- 48
Setting the Post-meal Alarm (PP2 alarm) ------------------------------------------------- 48
Setting the Time Alarms (alarm 1–3) -------------------------------------------------------- 50
Maintenance
Understanding Error Messages ----------------------------------------------------------------- 52
General Troubleshooting ------------------------------------------------------------------------- 54
Performance Characteristics --------------------------------------------------------------------- 55
System Accuracy and Measurement Precision ------------------------------------------ 55
Influence Quantities ---------------------------------------------------------------------------- 57
User Performance Evaluation ---------------------------------------------------------------- 58
Warranty Information ------------------------------------------------------------------------------ 59
Table of Contents

6www.i-sens.com
Important Information: Read This First!
For optimum safety and benefits, please read the entire
manual contents before using the system.
Intended use:
TEE2 Plus Blood Glucose Monitoring System is used for the
quantitative measurement of the glucose level in capillary
whole blood as an aid in monitoring diabetes management
effectively at home or in clinical settings. TEE2 Plus Blood
Glucose Monitoring System should be used only for self-
testing outside the body (in vitro diagnostic use only). TEE2
Plus Blood Glucose Monitoring System should not be used
for the diagnosis of diabetes or for testing newborns. Testing
sites include the traditional fingertip testing along with
alternate site testing on forearm and palm.
Meaning of Symbols Used:
For in vitro diagnostic use Authorised representative
This product fulfills the requirements for Directive 98/79/EC
on in vitro diagnostic medical devices
Cautions for safety and optimum product use
Use by (unopened or opened test strip vial)
Do not discard this product with other household-type
waste
Do not reuse Batch code
Consult instructions for use Manufacturer
Temperature limitation Serial number

www.spirit-healthcare.co.uk 7
•
Glucose in blood samples reacts with the chemical in the
test strip to produce a small electrical current. The TEE2
Plus meter detects this electrical current and measures the
amount of glucose in the blood sample.
•
The TEE2 Plus blood glucose meter is designed to minimise
code related errors in monitoring by using the no-coding
function.
•
The TEE2 Plus blood glucose meter should be used only
with the TEE2 Test Strips.
•
An abnormally high or low red blood cell count (hematocrit
level over 65 % or below 15 %) may produce inaccurate
results.
•
If your test result is below 3.3 mmol/L or above 13.3 mmol/L,
consult a healthcare professional immediately.
•
Inaccurate results may occur in severely hypotensive
individuals or patients in shock. Inaccurate low results
may occur for individuals experiencing a hyperglycemic-
hyperosmolar state, with or without ketosis. Critically ill
patients should not be tested with blood glucose meters.
•
Inaccurate results may occur in patients undergoing oxygen
therapy.
If you need assistance, please contact the Spirit Healthcare
24/7 Freephone Support Line at 0800 881 5423 or go to
www.spirit-healthcare.co.uk.

8www.i-sens.com
Specifications
Product specifications
Measurement range 1.1–33.3 mmol/L
Sample size Minimum 0.5 μL
Test time 5 seconds
Sample type Fresh capillary whole blood
Calibration Plasma-equivalent
Assay method Electrochemical
Battery life 1,000 tests
Power Two 3.0 V lithium batteries
(disposable, type CR2032)
Memory 1,000 test results
Size 108.4 x 55.8 x 15 (mm)
Weight 71 g (with batteries)
Bluetooth®
technology
•
Frequency range: 2.4–2.4835 GHz
•
Operating range distance: maximum
10 meters (unobstructed)
•
Operating channels: 40 channels
•
Security encryption: 128-bit AES
(Advanced Encryption Standard)
Operating ranges
Temperature 5–50 ˚C
Relative humidity 10–90 %
Hematocrit 15–65 %
Storage/transport conditions
Temperature
Meter (with batteries) 0–50 ˚C
Test strip 1–30 ˚C
Control solution 8–30 ˚C
Relative humidity Test strip 10–90 %

www.spirit-healthcare.co.uk 9
TEE2 Plus Blood Glucose Monitoring System
TEE2 Plus Blood Glucose Monitoring System includes the
following items:
* TEE2 Plus Blood Glucose Meter
* Owner's Booklet
* Quick Reference Guide
* Batteries
Optional items:
* TEE2 Blood Glucose Test Strips
* Lancets
* Lancing Device
* Logbook
* Carrying Case
•
Check all the components after opening the TEE2 Plus
Blood Glucose Monitoring System package. The exact
contents are listed on the main box.
•
Certain components may not be included depending on the
place of purchase.

10 www.i-sens.com
The TEE2 Plus meter uses two 3.0 V lithium batteries. Before
using the meter, check the battery compartment and insert
batteries if empty.
When the symbol appears on the display while the meter
is in use, the batteries should be replaced as soon as possible.
The test results may not be saved if the batteries run out.
Inserting or Replacing the Batteries
Step 1
Make sure the meter is turned off. Push the
cover in the direction of the arrow to open
the battery compartment.
Step 2
Remove the used batteries one at a time.
Slip your index finger under the battery to
lift and pull out as shown. Insert two new
batteries with the + side facing up and
make sure the batteries are inserted firmly.
Step 3
Place the cover on the battery
compartment. Push it down until you hear
the tab click into place.
Note:
Removing the meter batteries will not affect your stored
results. However you may need to reset your meter
settings. See page 16.

www.spirit-healthcare.co.uk 11
Caring for Your System
Use a soft cloth or tissue to wipe the meter exterior. If necessary,
dip the soft cloth or tissue in a small amount of alcohol.
Do not use organic solvents such as benzene or acetone, or
household and industrial cleaners that may cause irreparable
damage to the meter.
Caution:
•
Do not expose the meter to direct sunlight, heat, or excessive
humidity for an extended period of time.
•
Do not let dirt, dust, blood, or water enter into the meter’s
test strip port.
•
Do not drop the meter or submit it to strong shock.
•
Do not try to fix or alter the meter in any way.
•
Avoid getting any liquid or moisture in the test strip vial. This
can affect the test strips and cause inaccurate test results.
•
Do not apply samples other than capillary whole blood or
control solution to the test strip.
•
Strong electromagnetic radiation may interfere with the
proper operation of this device. Keep the device away from
sources of strong electromagnetic radiation, especially when
measuring your blood glucose.
•
Store all the meter components in the carrying case to
prevent loss and help keep the meter clean.
Disposal of the meter
If you need to throw your meter away, you should follow existing
policies and procedures of your own country or region. For
information about correct disposal, please contact your local
council or authority. If you need assistance, contact the Spirit
Healthcare 24/7 Freephone Support Line at 0800 881 5423 or go
to www.spirit-healthcare.co.uk.

12 www.i-sens.com
TEE2 Blood Glucose Test Strip
The TEE2 Plus Blood Glucose Monitoring System measures
blood glucose quickly and accurately. It automatically absorbs
the small blood sample applied to the narrow edge of the strip.
Insert
Contact bars
Gently push the test strip, with its
contact bars facing up, into the test
strip port of meter
Confirmation window
Check here to see whether sufficient
blood sample has been applied
Edge to apply blood sample
Apply blood sample here for testing

www.spirit-healthcare.co.uk 13
Warning!
•
The TEE2 Test Strips should be used only with fresh capillary
whole blood samples.
•
Do not reuse test strips.
•
Do not use test strips past the expiration date.
•
Test strips in new, unopened vials and test strips in vials that
have been opened can be used up until the expiration date
printed on the test strip box and vial label if the test strips are
used and stored according to its storage and handling methods.
•
Store test strips in a cool and dry place at a temperature
between 1–30 ˚C and 10–90 % relative humidity.
•
Keep test strips away from direct sunlight or heat and do
not freeze.
•
Store test strips only in their original vial.
•
Close the vial tightly after taking out a test strip for testing
and use the strip immediately.
•
Avoid getting any liquid or moisture in the test strip vial. This
can affect the test strips and cause inaccurate test results.
•
Do not apply samples other than capillary whole blood or
control solution to the test strip.
•
Handle test strips only with clean and dry hands.
•
Do not bend, cut, or alter test strips in any way.
•
For detailed storage and usage information, refer to the
TEE2 test strip package insert.
Caution:
•
Keep the meter and testing supplies away from young
children.
•
Drying agents in the vial cap may be harmful if inhaled or
swallowed and may cause skin or eye irritation.

14 www.i-sens.com
Note:
•
The cable for data management software can be ordered
separately. Please contact Spirit Healthcare on 0800 881
5423.
•
The unit of measurement is fixed and it cannot be
changed by the user.
TEE2 Plus Blood Glucose Meter
Display
Shows results
and messages
Test Strip Port
Insert test strip here
●
Button
Turns the meter
on/off, confirms
menu selections,
and changes
information
Data Port
Used to transfer data
from the meter to
a computer with a
cable
▲
,
▼
Button
Turns the meter
on, selects
or changes
information

www.spirit-healthcare.co.uk 15
Test results : test results displaying panel
Memory recall mode : appears when
test results stored in the memory are
displayed
PP2 alarm : appears when the post-
meal alarm has been set
Bluetooth symbol
Mute symbol : appears only when the
sound is set to OFF
Control Solution flag : appears when the
control solution test results are saved or
displayed
Decimal point : appears when the blood glucose measuring
unit is set to mmol/L
mmol/L : unit for measuring blood glucose
alarm: appears when the time alarm has been set
Battery symbol : indicates meter battery is running low and
needs to be replaced
Blood insertion symbol : indicates meter is ready for the
application of a drop of blood or control solution
Pre-meal test flag : used for tests done before eating
Post-meal test flag : used for tests done after eating
Fasting test flag : used for tests done after fasting for at least 8
hours
Month/Day/Hour/Minute
1
2 3 54 6
7
11
10
9
15
12 13 14
8
TEE2 Plus Blood Glucose Meter Display
10
12
7
8
9
11
13
14
15
Note:
It is recommended to check if the display screen on the meter
matches the illustration above every time the meter turns on.
Do not use the meter if the display screen does not exactly
match the illustration as the meter may show incorrect results.
4
5
1
2
3
6

16 www.i-sens.com
Setting Up Your System
Press and hold the
●
button for 3 seconds to enter SET mode.
After all settings are finished, press and hold the
●
button for 3
seconds to turn off the meter.
Press
the
▲
or
▼
button to change values. Press and hold the
▲
or
▼
button to scroll faster.
Step 1 Entering the SET Mode
Press and hold the
●
button for
3 seconds to enter SET mode.
After all the segments flash
across the screen, ‘SET’ will
show up.
Press the
▲
or
▼
button to
select 'YES' and press the
●
button to go to the next step.
Note:
Follow steps 2–3 to pair your meter and smartphone. Pairing
allows the meter to communicate wirelessly with your
smartphone. Ensure that devices are within the maximum
Bluetooth range (10 metres). Before pairing your meter and
smartphone, download and install the SmartLog mobile app
on your smartphone.

www.spirit-healthcare.co.uk 17
Step 2 Bluetooth Pairing
1
If you do not want to connect your meter to
your smartphone, press the
●
button when
the screen shows on the right. The meter will
go to Step 4 Year Setting mode.
Setting Up Bluetooth
2
Press the
▲
or
▼
button. The meter
screen will display 'OFF', 'On', and 'PAIr'
in turn. To pair your meter with your
smartphone, press the
●
button when
'PAIr' blinks on the screen.
Note:
The symbol will appear on the
screen when the Bluetooth feature
is on. When the symbol is not
present on the screen, the Bluetooth
feature is off. When you need to turn
off/on the Bluetooth feature, press the
●
button when OFF/On blinks on the screen.

18 www.i-sens.com
3
Look for 'TEE2' and the last
4 characters of the meter serial
number on the SmartLog mobile
app screen to correctly identify
your meter.
Touch your meter's ID (TEE2
XXXX) on the SmartLog mobile
app screen.
4
The meter will display six digit
PIN number.
Note:
Follow the on-screen instructions on SmartLog mobile app to begin
searching your meter. Some content or menus may differ depending
on your smartphone's operating system or SmartLog version.
Step 3 Entering the PIN number
1
The symbol and 'PIn' will appear
if you press the
●
button when the
meter screen shows 'PAIr'.
2
Launch SmartLog mobile app
to start pairing the meter with your
smartphone.
Find the 'Accessories' menu and select
the appropriate meter model on
SmartLog mobile app.
XXXXXXXXXXXX
The last 4
characters of
the meter serial
number

www.spirit-healthcare.co.uk 19
6
When your meter and
smartphone are paired and
connected, the meter will display
'SUCCESS' and the saved test
results will be transferred to your
smartphone.
7
When the data transfer is
finished, the meter will display
'End' on the screen. Press the
●
button to go to Step 10 Sound
Setting mode. See page 22. If the
meter displays 'FAIL' and then
'OFF', repeat steps 2 to 5.
5
Enter the PIN number into the SmartLog mobile app and
touch 'OK'. Make sure the PIN you enter on your smartphone
matches the PIN on your meter screen.
Note:
Some smartphones, especially those that are not tested or
approved by i-SENS, may be incompatible with your meter.
Visit www.i-sens.com/smartlog for more information about
supported smartphones. You can also scan the QR code on
the back cover of this user manual.

20 www.i-sens.com
Adjusting the Date and Time
Step 4 Setting the Year
Press the
▲
or
▼
button to adjust until the
correct year appears. When the present year
appears, press the
●
button to confirm your
selection and to go to the next step.
Step 5 Setting the Month
A number indicating the month will blink on
the screen.
Press the
▲
or
▼
button until the correct
month appears. Press the
●
button to
confirm your selection and to go to the next
step.
Step 6 Setting the Date
Press the
▲
or
▼
button until the screen
displays the correct date. Press the
●
button
to confirm the date and to go to the next
step.
Other manuals for TEE2+
1
Table of contents
Other Spirit Healthcare Blood Glucose Meter manuals
Popular Blood Glucose Meter manuals by other brands

Infopia
Infopia Evolution Operation manual

MHC Medical Products
MHC Medical Products Easy Touch user manual

Elektronika
Elektronika SensoLite Nova Test user manual

SD Biosensor
SD Biosensor SD Gluco Navii Operations & Procedures Manual

OneTouch
OneTouch OneTouch Ultra owner's booklet

FOR-A
FOR-A MD Operator's manual