Stahl OS-IT-479-2TX User manual

Operating instructions
MANTA GMP device platform
IT-xx9
SERIES 400 Panel PC
SERIES 500 Thin Clients
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Cologne
HW-Rev. IT-4x9: 01.00.11
HW-Rev. IT-5x9: 01.00.11
Operating Instructions Version: 01.00.01
Issue date: 19.12.2017

Operating Instructions OS-IT-xx9 Publisher
Page 2 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
Publisher
Publisher and copyright holder:
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Cologne
Registered place of business: Cologne
Court of registration: District court Cologne, HRB 30512
VAT number: DE 812 454 820
Phone: (switchboard) +49 (0) 221 76 806 - 1000
(hotline) - 5000
Fax: - 4100
(hotline) support@stahl-hmi.de
All rights reserved.
This document may not be reproduced in whole or in part except with the written consent
of the publisher.
This document may be subject to change without notice.
Any warranty claims are limited to the right to demand amendments. Liability for any damage that
might result from the contents of these instructions or all other documentation is limited to clear
cases of premeditation.
We reserve the right to change our products and their specifications at any time, provided it is in
the interest of technical progress. The information in the current manual (online or on CD / DVD /
USB stick) or in the operating instructions included in the delivery applies.
Trademark
The terms and names used in this document are registered trademarks and/or products of the
companies in question.
Copyright © 2017 by R. STAHL HMI Systems GmbH. Subject to alterations.

Operating Instructions OS-IT-xx9 Formatting conventions
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 3 of 20
Formatting conventions
The markings in these operating instructions refer to specific features that must be noted !
In detail, these are:
This sign alerts users to hazards that will result in death or serious
injury if ignored.
This sign alerts users to hazards that may result in death or serious
injury if ignored.
This sign alerts users to hazards that may result in injury if ignored.
Information highlighted by this symbol indicates measures for the
prevention of damage to machinery or equipment.
Information highlighted by this symbol indicates important information
of which particular note should be taken.
Information highlighted by this symbol refers to a different
chapter or section in this manual or other documentation
or a web-page.
Warnings
Warning !
In ambient temperatures exceeding +45 °C the surface of the HMI devices may
heat up. Caution when touching!
Caution !
Incorrect replacement of batteries may result in explosion !
Dispose of used batteries as described in instructions.
DANGER
WARNING
CAUTION
DOCUMENTATION
NOTE
CAUTION

Operating Instructions OS-IT-xx9 Table of contents
Page 4 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
Table of contents
Description Page
Publisher 2
Formatting conventions 3
Warnings 3
Table of contents 4
1Foreword 5
2Device function 5
2.1 IT-4x9 (SERIES 400 Panel PC) 5
2.2 IT-5x9 (SERIES 500 Thin Clients) 5
3Technical data 6
4Conformity to standards 8
5Identification 8
6Power supply 8
6.1 HMI devices 8
7Type code 9
7.1 IT-479-2TX (Panel PC) 9
7.2 IT-579-2TX (Thin Client) 10
8Safety information 11
8.1 General safety information 11
8.2 Cautionary note 11
8.3 Installation safety information 11
8.4 Safety information for operation 12
9Mounting and dismounting 12
9.1 General information 12
10 Commissioning 12
10.1 General information 12
10.2 Connections 13
11 General Information 15
11.1 IT-479 (Panel PC) and IT-579 (Thin Client) 15
11.1.1 Licensing issues 15
11.1.2 Recovery Stick 15
11.1.3 Back-up 15
11.1.4 Initial start-up IT-479 (Panel PC) 15
11.1.5 Switching off / closing down 16
11.1.6 Note on Windows Embedded operating systems 16
11.1.7 Loss of data 16
12 Maintenance 17
13 Troubleshooting 17
13.1 Repairs / hazardous substances 17
14 Disposal 17
14.1 RoHS directive 2011/65/EC 17
15 Declaration of EC conformity 18
16 Release notes 19

Operating Instructions OS-IT-xx9 Foreword
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 5 of 20
1 Foreword
These Operating Instructions contain all relevant information for the Manta GMP IT-xx9 devices
(SERIES 400 Open HMI - Panel PCs and SERIES 500 Thin Clients). They also contain
information on the connection and installation (etc.) of these devices.
Two devices are available with the Manta GMP device platform: the IT-479-2TX and the
IT-579-2TX, both with 61 cm display (24") and 2x 10/100/1000Base-TX Ethernet interface and
AC supply.
For the correct operation of all associated components please note, in
addition to these operating instructions, all other operating instructions
enclosed in this delivery as well as the operating instructions of the
additional equipment to be connected.
2 Device function
The MANTA GMP SERIES IT-479 and IT-579 Operator Stations (OS) have been developed for
installation in cleanrooms cleanliness class C according to EU-GMP and according to EHEDG.
Data is transmitted via dual Ethernet as 10/100/1000Base-TX via CAT7 across a distance of up
to 100 m.
The devices are connected to a communication system via the external serial interfaces (RS-232,
Ethernet). The USB interfaces, also external, can be used for the connection of various peripheral
devices. Furthermore, the interfaces for keyboard, mouse, video and audio signals are also
located here.
2.1 IT-4x9 (SERIES 400 Panel PC)
The IT-4x9 HMI devices are equipped with a Windows© operating system and can run any
software. They are therefore easy to operate.
The devices are fitted with powerful processors and are thus able to process even large
applications on-site. Thedevices have a back-up and recovery systemwhich can beused to save
complete images and load them onto new Panel PCs without requiring specific IT skills.
2.2 IT-5x9 (SERIES 500 Thin Clients)
The IT-5x9 SERIES 500 HMI devices can be integrated into modern networks as Thin Clients or
with a KVM box via KVM-over-IP. Digital Ethernet technology is used for the transmission of data
between the KVM-over-IP box and the Thin Client device.
Up to four Thin Clients can access one KVM-over-IP box with one software license, thus cost-
effectively communicating with several PCs - for example, when monitoring the production
process and simultaneously applying Condition Monitoring.
Multi-monitoring with several on-site terminals is as easy as the application as Thin Client in a
server environment with virtual work stations.
NOTE

Operating Instructions OS-IT-xx9 Technical data
Page 6 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
3 Technical data
Function / Equipment
OS-IT-479-2TX
OS-IT-579-2TX
General information
HMI-type
Operator station
Technology
Panel PC
Thin Client
Explosion protection
Application range (Zones)
non-Ex (safe area)
Electrical data
Processor
AMD GX-217GA
Processor details
AMD GX-217GA 1.65 GHz; Dual Core
Main memory
4 GB
Data memory
64 GB MLC
128 GB MLC
64 GB MLC
Graphics controller
AMD Radeon HD 8280E
Memory technology
SSD solid state flash drive
Operating System
Windows Embedded Standard 7 (64-Bit)
Windows 7 Ultimate (64-Bit)
Windows 10 (32-Bit and 64-Bit)
Windows 10 IoT Enterprise
Language support
via Windows operating system
HMI Image
-
Remote Firmware
Input voltage range
85 –250 VAC
Nominal voltage range
100 –240 VAC
Frequency range
50 - 60 Hz
Rated operational power
typ. 50 W (170 BTU)
Power consumption AC 1
1 A
Fuses AC
4 AT
Connections
via standard plug
Plug version AC
IEC plug (female)
Plug version USB
USB-A connector
Further connections
12 VDC Output
external on / off switch (pre-mounted at enclosure)
Loudspeaker output (optional)
Further connections - note
Only accessories approved by STAHL HMI may be connected to the 12 VDC output.
Plug version further connections
pluggable screw terminal, green, 6-pin 2.5 mm²
Fuses
2x 4A time-lag, 250 V
Ethernet / Data
2x 10/100/1000Base-TX
Interface medium
CAT7 Data transmission
USB interface
4x USB
Interface serial
2x RS-232
Interface audio
1 x Audio Line in / out
Connection impedance
12 W at 4 Ohm
Data cable
CAT7 installation cable AWG 23
Length of data cable
max. 100m
Minimum requirement connection cable
supply
3 x 1.5 mm²
Minimum requirement connection cable
Ethernet
CAT6
Real-time clock
Yes
Real-time clock data buffer
Lithium battery and capacitor buffered, maintenance-free
Battery type
BR2032
Battery buffer
> 5 years
Capacitor buffer
at least 4 days

Operating Instructions OS-IT-xx9 Technical data
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 7 of 20
Display
Display-Version
TFT Color display
Display version 2
16.7 million colours
Display size inch
24
Display size cm
61
Display resolution
Full HD
Display total pixels
1920 x 1080
Display dimensions
16:9
Display brightness
250 cd/m²
Display contrast
1000:1
Backlight
LED Technology
Life expectancy backlight
50 000 h at +20 °C
Touch screen
yes
Touch screen technology
projected, capacitive (PCAP), multi-touch
Display
Glass
horizontal viewing angle
at CR ≥ 10 = 178°
vertical viewing angle
at CR ≥ 10 = 178°
Ambient conditions
Ambient temperature, operation
0 °C … +45 °C
Storage temperature range
-20 °C … +60 °C
Cold start temperature
0 °C
Temperature note 3
Cold start temperature:
If the HMI device is switched on at a temperature below 0 °C the display will need a
certain amount of time to warm up until everything is clearly visible. Depending
on how low the temperature is, this process may last up to 3 hours.
Temperature note - general
The temperature details apply to a device combination with display, keyboard and
enclosure. Any additional built-in or added components may have an impact on
/ change these.
Heat disspation
about 40% via the upper front enclosure, about 60% via the back of the enclosure
Rel. air humidity
10 to 90% at +40°C [+104 °F], non-condensing
Mechanical data
Ingress Protection (IP)
IP66
Material (front)
Stainless steel / glass
Material (back)
Stainless steel
Dimensions (BxHxW)
674 mm x 664 mm x 356 mm
Weight
21.00 kg
Mechanical data - note
The mechanical data apply to a system with display and keyboard inside a GMP
enclosure. Any additional built-in or added components may have an impact on /
change these.
Mounting/ Installation
Enclosure type
Stainless steel enclosure (GMP)
Mounting option
Stand, mobile stand
Components
Keyboard
optional, 107 keys with trackball or touchpad

Operating Instructions OS-IT-xx9 Conformity to standards
Page 8 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
4 Conformity to standards
The IT-xx9 devices comply with the following standards and directive:
Standard
Classification
Electromagnetic compatibility
Directive 2014/30/EU
EN 61000-3-2 : 2014
EMC limitation of harmonic currents
EN 61000-3-3 : 2013
EMC limits
EN 61000-6-2 : 2005 + AC 2005
Immunity
EN 61000-6-4 : 2007 + A1 : 2011
Interference emission
EN 55032 2012 :
EMC interference emission
EN 55024 2010 :
Interference resistance properties
Low voltage directive
Directive 2014/35/EU
IEC 60950-1 : 2005 + A1 : 2009 + A2 : 2013
General requirements
EN 60950-1 : 2006 + A11 + A1+ A12 + A2
RoHS Directive
2011/65/EU
Classification
EN 50581 : 2012
Technical documentation evaluating electric
and electronic equipment with regards to
hazardous substances
5 Identification
Manufacturer
R. STAHL HMI Systems GmbH
Type designation
IT-479-2TX / IT-579-2TX
CE classification:
c
6 Power supply
6.1 HMI devices
Supply voltage: 100 - 240 VAC, 50 - 60 Hz
max. power consumption: 1 A

Operating Instructions OS-IT-xx9 Type code
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 9 of 20
7 Type code
7.1 IT-479-2TX (Panel PC)
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-jj-kk-ll
Design and material
Temperature range
Interfaces
Data memory
RAM
Processor
Card reader (internal)
Bluetooth
Touch
Display type
Voltage supply
Ethernet
Display size 61 cm / 24"
Device variant:
Classification product key
Description
Type with
IT-479-2TX-bb-cc-dd-ee-ff-gg-hh-ii-jj-kk-ll
2x Copper Ethernet interface 10/100Base-TX
IT-479-aa-AC-cc-dd-ee-ff-gg-hh-ii-jj-kk-ll
Power supply 100 - 240 VAC,
50 - 60 Hz
IT-479-aa-bb-D0-dd-ee-ff-gg-hh-ii-jj-kk-ll
TFT display (standard)
IT-479-aa-bb-cc-T3-ee-ff-gg-hh-ii-jj-kk-ll
Touch screen, capacitive
IT-479-aa-bb-cc-dd-B0-ff-gg-hh-ii-jj-kk-ll
No Bluetooth
IT-479-aa-bb-cc-dd-ee-C0-gg-hh-ii-jj-kk-ll
No internal card reader
IT-479-aa-bb-cc-dd-ee-ff-P2-hh-ii-jj-kk-ll
AMD GX-217GA processor
IT-479-aa-bb-cc-dd-ee-ff-gg-R3-ii-jj-kk-ll
4 GB RAM
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-MA-jj-kk-ll
64 GB Solid State Drive MLC
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-M9-jj-kk-ll
128 GB Solid State Drive MLC
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-I0-kk-ll
No additional interfaces
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-I1-kk-ll
USB plug
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-I2-kk-ll
USB plug GMP
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-I7-kk-ll
Audio amplifier
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-IA-kk-ll
USB plug and audio amplifier
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-IB-kk-ll
USB plug GMP and audio amplifier
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-IX-kk-ll
USB plug GMP, audio amplifier and LS2
loudspeaker (mounted inside enclosure)
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-jj-O7-ll
Temperature range 0 - 45 °C
IT-479-aa-bb-cc-dd-ee-ff-gg-hh-ii-jj-kk-G100
GMP enclosure, V2A stainless steel (SS304),
mounted on stand

Operating Instructions OS-IT-xx9 Type code
Page 10 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
7.2 IT-579-2TX (Thin Client)
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-jj-kk-ll
Design and material
Temperature range
Interfaces
Data memory
RAM
Processor
Card reader (internal)
Bluetooth
Touch
Display type
Voltage supply
Ethernet
Display size 61 cm / 24"
Device variant:
Classification product key
Description
Type with
IT-579-2TX-bb-cc-dd-ee-ff-gg-hh-ii-jj-kk-ll
2x Copper Ethernet interface 10/100Base-TX
IT-579-aa-AC-cc-dd-ee-ff-gg-hh-ii-jj-kk-ll
Power supply 100 - 240 VAC,
50 - 60 Hz
IT-579-aa-bb-D0-dd-ee-ff-gg-hh-ii-jj-kk-ll
TFT display (standard)
IT-579-aa-bb-cc-T3-ee-ff-gg-hh-ii-jj-kk-ll
Touch screen, capacitive
IT-579-aa-bb-cc-dd-B0-ff-gg-hh-ii-jj-kk-ll
No Bluetooth
IT-579-aa-bb-cc-dd-ee-C0-gg-hh-ii-jj-kk-ll
No internal card reader
IT-579-aa-bb-cc-dd-ee-ff-P2-hh-ii-jj-kk-ll
AMD GX-217GA processor
IT-579-aa-bb-cc-dd-ee-ff-gg-R3-ii-jj-kk-ll
4 GB RAM
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-MA-jj-kk-ll
64 GB Solid State Drive MLC
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-I0-kk-ll
No additional interfaces
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-I1-kk-ll
USB plug
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-I2-kk-ll
USB plug GMP
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-I7-kk-ll
Audio amplifier
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-IA-kk-ll
USB plug and audio amplifier
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-IB-kk-ll
USB plug GMP and audio amplifier
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-IX-kk-ll
USB plug GMP, audio amplifier and LS2
loudspeaker (mounted inside enclosure)
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-jj-O7-ll
Temperature range 0 - 45 °C
IT-579-aa-bb-cc-dd-ee-ff-gg-hh-ii-jj-kk-G100
GMP enclosure, V2A stainless steel (SS304),
mounted on stand

Operating Instructions OS-IT-xx9 Safety information
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 11 of 20
8 Safety information
Read the safety information listed in section 8 carefully to avoid injury
and damage to equipment!
8.1 General safety information
All relevant accident prevention regulations and the rules for electric installations have to
be observed during installation, maintenace and operations. All persons involved in
installation, commission, maintenance and repairs of this device and its accessories must
be qualified accordingly and must have familiarised themselves with this manual and any
associated documentation.
In case of non-compliance or contravention of the above protection is no longer guaranteed
and all warranty claims shall be null and void.
National safety and accident prevention rules apply.
Use the device for its intended purpose only.
No changes to the device are permitted. The enclosure may only be opened by R. STAHL
HMI Systems GmbH.
The first four digits of the serial number on the type plate stand for the year of manufacture.
8.2 Cautionary note
This is a Class A product.
In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.
8.3 Installation safety information
The applicable national assembly and installation rules andthe generally accepted technical
rules must be observed. The device and its accessories must be connected and operated
according to applicable standards, directives and installation guidelines. Only qualified
personnel or personnel that has been instructed accordingly are allowed to install the
device.
The device has been certified as a fixed, stationary device. The device must be mounted
on a bracket or be fixed to a specified place in another way.
The device may only be moved when it is disconnected from the mains. Keep in mind the
EPL.
Only appropriate tools must be used for the installation.
The wire used for earthing must have a minimum cross section of 4 mm² ! Make sure that
there is equipotential bonding between the devices.
We recommend you use screened cables with the device. Routing of the data cable may
reduce performance.
The maximum voltage of 250 V and a short current of 1500 A must not exceed at the place
of installation.
CAUTION
CAUTION

Operating Instructions OS-IT-xx9 Mounting and dismounting
Page 12 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
IEC 60950 stipulates that an easilyaccessible disconnection device must belocated outside
of an IT-x79 device which can be used to interrupt the power line.
Before starting up the device you must ensure that it has been installed according to
regulations and that neither the device nor its cables are damaged.
8.4 Safety information for operation
The device may only be operated in an undamaged and clean condition. If the device is in
any way damaged, do not touch it to avoid injury. In the case of any damage that may
compromise ingress protection (e.g. cracks, holes or broken components) the device must
be taken out of commission immediately. Before the device is recommissioned the
damaged components must be replaced.
In general, and particularly when opening and closing enclosures, users must take care not
to get injured by getting caught / trapped.
9 Mounting and dismounting
9.1 General information
Assembly and disassembly are subject to general technical rules.
Additional, specific safety regulations apply to electronic and
pneumatic installations. In Germany, for example, these include the
BG regulations (Government Safety Association) and the BetrSichVer
(Betriebsicherheitsverodnung - Occupational Health and Safety).
Mounting, connection, commissioning, repair and maintenance may only be carried out by
qualified staff specially trained for this purpose.
10 Commissioning
10.1 General information
When operating the devices, particular care shall be taken that:
The HMI device has been properly installed according to
instructions.
The HMI device is undamaged.
all screws are tightened fast,
before switching on the HMI device, its external equipotential
bonding terminal is properly connected to the equipotential
bonding system at its place of use.
NOTE
NOTE

Operating Instructions OS-IT-xx9 Commissioning
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 13 of 20
10.2 Connections
Designation
Number
View
Connection
Meaning
1
-
On / off switch
PWR
(Power)
2
IEC connector
Power supply of the
HMI device AC
USB
4 x
3
USB-A connector
USB interface,
connection type A,
USB2.0
LAN1
(Data)
4
1……8
RJ-45 connector
Ethernet interface
copper connection 1
LAN2
(Data)
5
1……8
RJ-45 connector
Ethernet interface
copper connection 2
COM1
(serial)
6
9-pin sub-D plug
(male)
Serial interface RS-232
COM2
(serial)
7
9-pin sub-D plug
(male)
Serial interface RS-232
8
DVI-I connector
DVI connection
9
PS/2 socket
Mouse connection
10
PS/2 socket
Keyboard connection
AUD
(Audio)
11
TRS socket
(stereo)
2 x 3.5 mm
Audio line in / out
interface
1
2
8
6
7
4
5
9
10
11
12
3
13

Operating Instructions OS-IT-xx9 Commissioning
Page 14 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
12
1 6
6-pin connector
with terminals
Connection for
- external push button *
- loudspeaker **
- 12 VDC output
Pin
1
GND
external push-button
(integrated in GMP
enclosure)
2
P
3
LSP -
Loudspeaker output
(optional)
4
LSP +
5
GND
12 VDC output, 1 A
6
+12 V DC
F
13
for wire L
Fuses 2x
for wire N
max. recommended cable length for USB, keyboard, mouse,
RS-232 and audio: 3 m
* The external push button is mounted inside the GMP enclosure
ex-factory, and has the same function as the power switch of a
PC (or its function can be defined as such via the system control).
** The use of a loudspeaker also requires the optional audio
amplifier (see type key).
NOTE

Operating Instructions OS-IT-xx9 General Information
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 15 of 20
11 General Information
11.1 IT-479 (Panel PC) and IT-579 (Thin Client)
11.1.1 Licensing issues
The SERIES 400 and 500 HMI devices usually have a Windows operating system pre-installed.
The corresponding license sticker is affixed on the back of the operator interface, next to the type
plate.
Please note that according to the license issued for Windows the application of these systems as
Office PC is not permitted.
Please also note the information on the licensing
stipulations for Windows operating systems contained in
the "TechNote Windows Operating Systems" file located
on the CD / DVD / USB stick which is part of the delivery.
11.1.2 Recovery Stick
A recovery stick is included in the deliveryto enable you to restore your
HMI device to its original state. This recovery stick (USB-drive, also,
optionally, available intrinsically safe) contains the factory image, with
which the system can be restored to delivery status within a very short
time.
Please note that you can restore the HMI devices to their original state
only with the aid of the recovery stick.
As an option, the recovery stick can also contain a backup software,
with which you can back up your own device configuration.
11.1.3 Back-up
Please note that it is the sole responsibility of the operator to generate
a back-up of the HMI devices and their overall function.
We strongly recommend such a back-up to be stored on an external
storage medium and / or on the company network.
11.1.4 Initial start-up IT-479 (Panel PC)
When started for the first time, the Windows installation Wizard starts, prompting users to select
certain settings.
Please follow the instructions of the installation Wizard.
NOTE
NOTE
DOCUMENTATION

Operating Instructions OS-IT-xx9 General Information
Page 16 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
11.1.5 Switching off / closing down
The Microsoft Windows operating system stores key data in the main
memory, regardless of the application, and has to store this data on
the hard disk before the HMI device is switched off.
It is therefore important for the safe and correct operation that the HMI
device is "shut down" properly (see illustration below) and not simply
switched off.
Otherwise the existing image of the HMI device may be damaged,
rendering the device non-functioning.
11.1.6 Note on Windows Embedded operating systems
When using the Windows Embedded 7 operating system on the Panel PC SERIES 400 HMI
devices, the C:\ system drive can be protected from unauthorised writing (EWF).
This is not the case for other Windows operating systems!
R. STAHL HMI Systems GmbH recommends you leave the write
protection filter on at all times.
For further information on this write protection (EWF),
please refer to the OpenHMI_help_en.chm help file in the
"STAHL" folder on the HMI device or on the CD / DVD /
USB stick that is included in the delivery.
11.1.7 Loss of data
In the case of applications that require constant writing into memory,
R. STAHL HMI Systems GmbH recommends you use external storage
media (USB sticks, network servers) for these write processes.
Try and avoid cyclical writes (log files, databases, etc.) to the SSD.
The endurance of an SSD depends on the number of write cycles
(TBW / terabytes written).
Writing to the SSD with a simultaneous drop in voltage is most likely
going to result in data loss.
NOTE
CAUTION
DOCUMENTATION
NOTE
NOTE
CAUTION
CAUTION

Operating Instructions OS-IT-xx9 Maintenance
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 17 of 20
12 Maintenance
Because the transmission of the devices remains reliable and stable over long periods of time,
regular adjustments are not required.
Keep the units clean so that theenclosure locks and screws remain accessible. Maintenance may
be required for the enclosure seal.
The following must be checked during maintenance work:
a. Seal wear
b. Display damage
c. All screws are tightened fast
d. All cables and lines are properly connected and undamaged
13 Troubleshooting
13.1 Repairs / hazardous substances
An error description must be enclosed with any units returned to R. STAHL HMI Systems GmbH
for repairs.
Remove all material residues. Please pay particular attention to the seal grooves and slits where
material residues may be lodged. We have to ask you not to return a unit if you are unable to
completely remove any hazardous substances. We shall bill you for any costs arising from
insufficiently cleaned units, such as disposal or damage to persons (chemical burns, etc.).
14 Disposal
Disposal of packaging and used parts is subject to regulations valid in whichever country the
device has been installed.
The disposal of devices sold after August 13th, 2005, and installed in countries under the
jurisdiction of the EU is governed by directive 2002/96/EC on waste electrical and electronic
equipment (WEEE, new edition 2012/19/EU). Under this directive, the HMI devices are category
9 devices (monitoring and control devices).
We shall take back our devices according to our General Terms and Conditions.
14.1 RoHS directive 2011/65/EC
The revision of RoHS directive 2002/95/EC and the resulting revised version 2011/65/EC extends
its scope to all electric and electronic products.
The HMI devices (category 9 - monitoring and control devices) meet the requirements of RoHS
Directive 2011/65/EU dated 03.01.2013.

Operating Instructions OS-IT-xx9 Declaration of EC conformity
Page 18 of 20 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017
15 Declaration of EC conformity

Operating Instructions OS-IT-xx9 Release notes
R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 Page 19 of 20
16 Release notes
The chapter entitled "Release Notes" contains all the changes made in every version of the
operating instructions.
Version 01.00.00
Original version of the operating instructions
Version 01.00.01
Addition of warning according to "Batteries"
Addition of "fuses" in "Technical Data" and in "Connections"
Addition of batterie type in "Technical Data"
Changing into "new device platform xx9"
Renew Declaration of EC conformity
Formale corrections

R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Cologne
Phone: (switchboard) +49 (0) 221 76 806 - 1000
(hotline) - 5000
Fax: - 4100
(hotline) support@stahl-hmi.de
www.stahl.de
www.stahl-hmi.de
This manual suits for next models
1
Table of contents
Other Stahl Desktop manuals
Popular Desktop manuals by other brands

Lenovo
Lenovo Aptiva Kurzübersicht

Compaq
Compaq BL10e - HP ProLiant - 512 MB RAM Update

Mitsubishi Electric
Mitsubishi Electric Apricot LS660 Owner's handbook

IBM
IBM PC 300GL Types 6275 installation guide

HP
HP Pavilion Media Center m7400 - Desktop PC Quick setup

IBM
IBM IntelliStation E Pro Hardware Maintenance Manual