STC 4V130E-430E Series Operating and maintenance manual

4V130E-430E SERIES AIR PILOT VALVE
Valve Model
4V130E-1/8
4V230E-1/4
4V330E-3/8
4V430E-1/2
Port & Mounting
Body Ported
Action & Motion
Double Solenoid, Spool Design, 3 Position, Exhaust Center, Response Time <20ms
Operating Pressure
21-115 PSI
Port Sizes
1/8 NPT
1/4 (in/outlet)
1/8 (exhaust)
3/8 (in/outlet)
1/4 (exhaust)
1/2 NPT
Operating Temp.
14 to 140 °F
Cv
0.67
0.89
1.68
2.79
SFCM @ 100PSI
25
53
80
160
Manual Override
Detentable
Electrical Connection
Grommet, DIN
Working Medium
40 micron filtered air or inert gas
Coil Insulation &
Protection Class
IP 65, Class F
Coil Duty Cycle
100% ED
Coil Voltage Options
Options: 12, 24 VDC; 24,110/120, 220/240 VAC (50/60Hz)
Coil Power
2.5W
3/4.8W
Coil Locking Nut
M8X0.75 Threads
Valve Body Material
Anodized Aluminum
Seal Material
NBR (Buna N)
Lubrication
Not Required
1

4V130E-430E SERIES SOLENOID VALVE DIMENSIONS
2

4V130E-430E SERIES SOLENOID VALVE DIMENSIONS
3

4-Way 2 Solenoid 3 Position Valve
Models 4V130-4V430 C, P, E
Installation Procedure
Warning: Do NOT over tighten the nut holding the coil to the armature tube. Over tightening may result in damage to
the welded joint.
Maintenance and Troubleshooting
Note: After an extended period of operation, if you do not hear a clicking sound when the valve is operational, and the
wiring is correct, the coil may be burned out and must be replaced. This commonly occurs when input voltages are
higher than the coil’s specifications.
Attaching a Coil to a Valve:
1. After wiring the coil, fit the coil assembly over the armature tube. Ensure that the threads of the tube are acces-
sible.
2. Fit the spring or lock washer over the assembly.
o For spring washers, the concave side should be oriented toward the coil.
3. Tighten the nut over the washer by hand.
o For spring washers, tighten the nut further until the spring coil is almost completely flat.
o For lock washers, tighten the nut another quarter turn.
Note: This valve is designed for air flow only.
Reference Figures:
Figure 1: Model 4V130P with port labels
Operational Notes
Continuous power to the coil is not required to maintain the solenoid position.
To move the piston to a new position, power the corresponding coil. Do not power both coils at the same time.
Turn off power to the coil when piston reaches desired position.
Installing Valve onto Manifold:
Note:
Manifolds can fit 2, 4, 6, 8 and 16 valves.
Secure screws until the component will not move freely, and tighten another quarter turn.
Procedure:
1. Place a rubber seal over the manifold openings.
2. Line up the valve with port “A”, “EA, “EB” and corresponding pilot holes for the screws.
3. Secure the valve into place.
4. Cover the remaining holes with the provided gaskets.
Procedure:
1. Remove any coils attached to the valve.
2. Unscrew the holding plate and the armature tube and remove it from the valve body. Remove the piston.
3. Check for any debris that may have collected on the piston and the hole in the center of the valve.
4. Insert the piston back into the valve body.
5. Screw the armature tube and holding plate back into the valve.
Installation:
1. Connect the source to the port labeled “P”.
2. Connect the first outlet to the port labeled “A”.
3. Connect the first exhaust to the port labeled “EA”.
4. Connect the second outlet to the port labeled “B”.
5. Connect the second exhaust to the port labeled “EB”.
4

Installation of 3V100-400 and 4V100-400 Solenoid Valves
Electrical Connections
To connect DIN coils:
1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil.
2. From the screw opening, use the screw to push the terminal block out of the plastic housing.
3. Note the 1, 2 and ground markings on underside of DIN enclosure.
4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative.
5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect ground to ground
wire.
To connect Grommet coils or Lead Wire DIN coils:
DC Coil:
1. If the DC solenoid coil has a red and a black wire, Connect Positive to RED wire and Negative to
Black wire.
2. If the DC solenoid has two same color wires, connect Positive to one of the two wires and Negative
to the other wire.
AC Coil:
1. If the AC solenoid coil has a black a white wire, Connect the HOT wire to BLACK wire and Neutral to
WHITE wire.
2.If the AC solenoid has two same color wires, connect HOT wire to one of the two wires and
NEUTRAL wire to the other wire.
Do not energize the coil without installing it onto the valve, it will burn the coil and create fire
hazards.
Connection of 3V100–400 & 4V100-400 Solenoid Coils
Connect the 3V100-400 3 way valve
inlet and out as shown in the diagram :
P = Air Supply Port
A = Outlet A Port
EA/EB = Exhaust Outlet A
(Connection Optional)
Connect the 4V100-400 4 way valve
inlet and out as shown in the diagram :
P= Air Supply Port
A = Outlet A Port
B = Outlet B Port
EA = Exhaust Outlet A Port
(Connection Optional)
EB = Exhaust Outlet B Port
(Connection Optional)
5

STC Installation and Operation Procedure
4V130E-430E Series Solenoid Valves
4V130E-430E (Exhaust Center, 4 way, 3 Position valve)
VALVE POSITION 1 2
Operations:
1. When Valve is in Position 1, Port P is connected to Port A. Port B is connected to Port EB.
2. When Valve is in Position 2, Port A is connected to Port EA. Port B is connected to Port EB. Port
P is Closed. The valve is spring centered.
3. When Valve is in Position 3, Port P is connected to Port B. Port A is connected to Port EA.
A
EBP
AB B
EA EBEA P
3
A
EBP
B
EA
6

Catalog No.: PUB 2012—4V130E-430E
Information contained herein may be changed without prior notification.
Terms and Conditions
By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as
agreed in writing signed by us. We reserve the right to correct typographic errors and reject orders.
SHIPMENTS:
All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 94303, USA. Most orders are shipped via UPS Standard Ground unless instruc-
tions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit
rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping.
RETURN OF MERCHANDISE:
No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without
obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully pre-
paid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error.
Shortages & Mis-Shipments: Any shortages or mis-shipment must be reported within 15 days.
CANCELLATION POLICY:
Blanket order can be canceled 90 days before scheduled ship date. There will be a 10% charge if a blanket order is cancel within 90 days of
scheduled ship date, and a 20% charge if cancel within 60 days. Regular order for non-custom parts can be canceled any time before the order
is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever
comes later.
.
Remittances should be sent to:
Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 94303, USA
Credit Card Payments: Visa, MasterCard, Discover, or American Express Accepted
International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card.
Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account
numbers.
LIMITED WARRANTY –IMPORTANT NOTICE TO PURCHASER:
Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This
limited warranty expires one year after delivery to the end-user. STC’s entire obligation to the Purchaser for breach of this limited warranty shall
be limited to replacement of the defective product or refund of the original purchase price of this product, at STC’s option. Purchaser has thirty
(30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser.
STC’s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during
handling or storage.
.
DISCLAIMER OF IMPLIED WARRANTIES:
All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to,
implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond
the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular appli-
cation.
OBLIGATIONS
You warrant, represent and agree: (1) to comply with all laws; (2) that our sale and shipment of the product will not, by export thereof, your legal
status or otherwise, cause us to violate any law; and (3) to indemnify us against any losses from a failure by you or a third party to comply with
law or these terms and conditions, or from use of the product.
SAFETY WARNING
Failure or improper selection or improper use of the components and products described herein or related items can cause death,
personal injury and/or property damage. This document and other related information from STC provide products options for further investi-
gation by users having the technical expertise. It is important that you analyze all aspects of your application and review the information con-
cerning the component or product in the current catalog. Due to the variety of operation conditions and applications for these components or
products, the user, through his own analysis and testing, is solely responsible for making the final selection, installation and maintenance of the
products and assuring that all performance, safety and warning requirements of the application are met. All products set-ups and maintenance
require the supervision of a qualified individual who is familiar with installation, inspection and testing through training or experience.
IMPORTANT NOTICE:
The products described herein, including without limitation, product features, specifications, design, availability and pricing, are subject to
change without notice. We continuously improve the products, and we reserve the right to change specifications without incurring any obligation
to incorporate new factors in equipment previously sold.
Sizto Tech Corporation
892 Commercial Street
Palo Alto, CA 94303 USA
Tel: 650-856 8833 | Fax: 650-856 8811
S T C
7
This manual suits for next models
4
Table of contents
Other STC Control Unit manuals
Popular Control Unit manuals by other brands

Texas Instruments
Texas Instruments OPT3004EVM user guide

YASKAWA
YASKAWA VIPA SPEED7 Operation manual

Boardcon Embedded Design
Boardcon Embedded Design CM3588S Reference User Manual

Rotex
Rotex E PAC Series installation manual

Alfa level
Alfa level CSI RV-ST instruction manual

Texas Instruments
Texas Instruments ADS5296 user guide

LEGRAND
LEGRAND Niloe 6 651 12 manual

Cinterion
Cinterion EES3 Hardware interface description

Watlow
Watlow F4T quick start guide

Supra
Supra Vision PV1100 owner's manual

Crosswater
Crosswater KL0007WC installation instructions

Wigersma & Sikkema
Wigersma & Sikkema UNIGAS 300 Installation, operating and maintenance manual