stellar labs S500 Series User manual

S500 Series
Operation manual for GSM temperature humidity data logger

Operation manual for GSM temperature humidity data logger
CONTENTS
CHAPTER 1. INTRODUCTION......................................................................................................1
1.1 FEATURES ................................................................................................................................................................ 1
1.2 TECHNICAL SPECIFICATIONS......................................................................................................................................... 1
1.3 APPLICATIONS........................................................................................................................................................... 2
1.4 INSTALLATION AND INSTRUCTIONS FOR SIM CARD............................................................................................................ 2
1.5NOTICE ................................................................................................................................................................... 2
1.6 PRODUCT STRUCTURE ................................................................................................................................................ 2
1.7 LCD DISPLAY INSTRUCTIONS ........................................................................................................................................ 3
1.8 INSTRUCTIONS FOR BUTTONS....................................................................................................................................... 4
CHAPTER 2. SOFTWARE .............................................................................................................5
2.1 THE REQUIREMENT OF THE COMPUTER HARDWARE......................................................................................................... 5
2.2 INSTALL DRIVER & SOFTWARE...................................................................................................................................... 5
2.3 SETTING THE LOGGER’S PROPERTIES TO START A NEW MEASUREMENT.................................................................................. 5
2.4 DATA ANALYSIS ......................................................................................................................................................... 8
CHAPTER 3. ATTENTION...........................................................................................................10
CHAPTER 4. FAQ......................................................................................................................10
4.1 LCD SCREEN DIM.................................................................................................................................................... 10
4.2 RECORDING (LOG) ARE AUTOMATICALLY STOP ............................................................................................................. 10
4.3 SOFTWARE "RUNTIME ERROR".................................................................................................................................. 10
4.4 CHECK COM PORT NUMBER..................................................................................................................................... 10

Operation manual for GSM temperature humidity data logger
1
Chapter 1. Introduction
S500 series GSM temperature humidity data logger is the new generation data logger , which has been
added with the GSM alarm message function based on the original S500 series. Users can dial the data logger
through any mobile phone to get the temperature and humidity values, besides, the temperature humidity data
logger will send alarm message to defined users automatically once the setting limits being exceeded.
1.1 Features
◼Elegant appearance, easy to operate and reliable. Desktop and wall-mounted.
◼High accuracy (0.2~0.5℃/2~5%RH) with large capacity. (65000).
◼Large LCD display, temperature and humidity being showed simultaneously.
◼Internal audible and visual alarm and send alarm message to mobile phone once temperature or
humidity is over limit.
◼Data query function via mobile phone. Get the real time data anytime at anywhere.
1.2 Technical Specifications
Model
Accuracy
Measuring range
Sensor type
Capacity
S500-TH-GSM
±0.5℃/±5%RH
-20~70℃
0~100%RH
Temperature + humidity ,
internal
65000
S500-EX-GSM
±0.5℃/±5%RH
-40~85℃
0~100%RH
Temperature + humidity ,
external sensor with 3 meters
65000
S520-TH-GSM
±0.3℃/±3%RH
-20~70℃
0~100%RH
Temperature + humidity ,
internal
65000
S520-EX-GSM
±0.3℃/±3%RH
-40~85℃
0~100%RH
Temperature + humidity ,
external sensor with 3 meters
65000
S580-TH-GSM
±0.2℃/±2%RH
-20~70℃
0~100%RH
Temperature + humidity ,
internal
65000
S580-EX-GSM
±0.2℃/±2%RH
-40~85℃
0~100%RH
Temperature + humidity ,
external sensor with 3 meters
65000
S500-ET-GSM
±0.5℃
-40~85℃
Single Temperature external
sensor with 3 meters
65000
S500-DT-GSM
±0.5℃
-40~85℃
Dual Temperature external
sensor with 3 meters
65000
S500-EPT-GSM
±0.5℃
-100~100℃
PT100 single temperature
external sensor with 2 meters
65000
S520-ET-GSM
±0.3℃
-40~85℃
Single Temperature external
sensor with 3 meters
65000
S520-DT-GSM
±0.3℃
-40~85℃
Dual Temperature external
sensor with 3 meters
65000

Operation manual for GSM temperature humidity data logger
2
1.3 Applications
It has been widely applied in agricultural research industry, food industry, medical industry, electrical
industry, environment protection and laboratory fields.
1.4 Installation and instructions for SIM card
1、Suggest to buy GSM SIM card (SIM card without monthly rent), it must be GSM network SIM
card, CDMA network is invalid.
2、Install or remove SIM card should be under the sate of Power OFF
3、Just call the alarm temperature humidity data logger via any mobile phone and it will respond
you with message when you want to know the temperature and humidity values.
1.5 Notice
1、Only GSM network SIM card,support 2/3/4g.
2、Ensure that the SIM card is of certain amount of money for the text message fee.
3、The data logger must be supported by External Adapter—DC 9V and turn on the alarm function
to activate the alarm message system, otherwise it can not send message successfully.
1.6 Product structure
LCD display
Hanger (used for fixing on the wall)
ON/OFF
Holder (used for desktop)
Backlight
Battery cover (screw to replace the battery)

Operation manual for GSM temperature humidity data logger
3
MAX/MIN checking button
Serial Number
LOG
External Probe Port
Reset button
External Probe
USB port
SIM card slot
DC Power Jack (9~12V)
Wireless antenna
1.7 LCD display instructions
Temperature and humidity values display.
Symbol for backlight.
Symbol for alarm, it will alarm when temperature and humidity setting limits being exceeded.
This symbol shows that data logger is being supported by external power—DC 9V.
This symbol shows that data logger is connected with PC and you can download all the recording
data.
This symbol shows that all buttons are locked.
Battery indication
This symbol shows that SIM card inset well.
This symbol shows that buttons are unlocked
This symbol shows that data logger is being the recording status.
Display area for recording numbers
Display area for year/month/date/time; alternate display.
Symbol for humidity unit
Symbol for temperature unit

Operation manual for GSM temperature humidity data logger
4
Symbol for temperature unit
1.8 Instructions for buttons
Log function button, turn on/off the log function.
Maximum and minimum button.
Press to check the maximum and minimum value of all the recording data.
Backlight on/off button.
On/Off button
Notice:
(1)Press and simultaneously can lock and unlock data logger.
(2)Data logger has alarm message system only when data logger is under logging status.

Operation manual for GSM temperature humidity data logger
5
Chapter 2. Software
2.1 The Requirement of the Computer Hardware
1. OS: Windows XP/Vista/7/8 (32/64bit)
2. CPU: 1.6GHz
3. Physical Memory: 512MB
4. Hard-drive Space: 4 GB
5. USB Port: 1
2.2 Install Driver & Software
1. Install Driver
Notice: Windows 64bit please install 64bit-driver.
2. Install Logpro Software
Notice: Please Install Logpro Software in D:\
2.3 Setting the logger’s properties to start a new measurement.
1. Connect the data logger to the computer.
1
2. Running Logpro software on the PC.
3. From the toolbar select Connect.
2
4. Read the logger’s properties.
5. Set the properties.
6. Sync the properties & time. (The PC time will be synchronized to the logger as well.)
1
The windows operating system cannot handle USB devices being unplugged and plugged back too fast. When unplugging the logger,
wait for about 5 seconds before plugging it in again. If you unplug and plug back a device too quickly, the computer may stop recognizing
any USB devices on that port. If this happens you will have to restart the computer. This is a windows USB problem and is not related to
Logpro.
2
If more than one logger is connected to your computer at the same time, the program will ask you to choose COM port manually.

Operation manual for GSM temperature humidity data logger
6
Property
Text
Description
Name
English Letters or Numbers
Name of the logger
SN
10 Characters
Must be the same as the one in the label of
logger.
Sampling Interval (s)
Number from 1 to 240
Sampling frequency in LCD screen
Logging Interval (s)
Number from 2 to 86400
Logging frequency.
Down Mode
Save Always
Do not clear the Logger's memory after
download
Delete after download
Clear the Logger's memory after download
Start Mode
Start Now
Start log when the Logger was turn ON.
Delay Start
Wait Delay Time then start log.
Timing Start
Start log when Delay Time: HHMMSS
e.g. 170000 means 17:00:00
Delay Time
Input a Delay Time or Timing Time.
Stop Mode
First In First Out
When recording memory is full, the logger
will delete the earliest data
Stop When Full
When recording memory is full, the logger
will stop record new data
Logs
The count of records in the memory.
Total
The total capacity of the logger’s storage.
Alarm
Turn ON / OFF the Data Logger's Buzzer.
LCD
Please choose ON
Power
Please choose Normal
High & Low Limit
CH1: Temperature
CH2: Humidity / Temperature2
When the value over the limit, the buzz will
sounds an alarm.
Offset3
Input positive number to decrease the value.
Input negative number to increase the value.
3
Calibrate the logger: The logger is factory calibrated to an accuracy given in the device specifications. However, there may be times when you wish
to adjust the calibration of your logger. Logpro provides you with the ability to perform a single point offset calibration. This calibration can be used
to increase the accuracy of the logger for a restricted data range.
Sync
Read Settings

Operation manual for GSM temperature humidity data logger
7
7. Choose 【GSM Setup】to setup cell phone number to receive alarming message.
Click to
confirm
Click to Sync
Settings
Input Cell#

Operation manual for GSM temperature humidity data logger
8
8. Setup the temperature and humidity upper and lower limits.
9. Then sync the setup with loggers after finish setup.
2.4 Data Analysis
1. Click on 【Download】to download data to the computer, it will be automatically saved and will generate
reports and data list.
2. Click on 【Data List】to display downloaded data on the left.
Temp upper and
lower limits
Humid upper and
lower limits

Operation manual for GSM temperature humidity data logger
9
3. Click on to save the data in the Excel format; or click on to save the data in a PDF
file; or click on to save data in a picture.
4. Click on【Delete】to clear the data logger’s flash chip.
Data List

Operation manual for GSM temperature humidity data logger
10
Chapter 3. Attention
⚫S500 Series Data Logger are not waterproof. Do not connect loggers with computer when the logger is on
water.
⚫S500 Series Data Logger plastic shell is ABS, flame retardant, not resistant to acid and alkali.
⚫If repair is needed, only authorized technician could do the repair.
⚫The instrument configuration by 1 x 6LR61 alkaline battery (9V) is not rechargeable.
⚫USB power supply (5V) cannot let the Data Logger work.
Chapter 4. FAQ
4.1 LCD Screen Dim
Reason:
⚫Insufficient battery or the environment temperature is too low or too high.
Solution:
⚫In the case of insufficient battery, please replace the battery. If resulted from environment temperature,
please immediately take the logger out of the environment.
4.2 Recording (LOG) are Automatically Stop
Reason:
⚫When the battery level is low, there will not be sufficient power to support recording function of the logger.
Solution:
⚫Replace the battery.
4.3 Software "Runtime Error"
Reason:
⚫OS forbid software creating files.
Solution:
⚫Run the program (software) as an administrator.
⚫Install software in Disk D:\
⚫A data logger name cannot contain any of the following characters: \ / : * ? " < > |
⚫Software’s installation path cannot include Chinese character or garbage character.
4.4 Check COM Port Number
⚫Press “Win” + “R” in keyboard -> Run "devmgmt.msc" to Open "Device Manager" in Windows-> Expand
"Ports (COM & LPT)" -> "USB-SERIAL CH340 (COM No.)" is the Data Logger