MadgeTech PRTemp140 Specification sheet

PRTemp140
High Temperature and Pressure
Data Logger
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
TABLE OF CONTENTS
2Product Overview
2Installation Guide
2Device Operation
3Device Maintenance
4Need Help?
Product User Guide | 2
PRTemp140
PRODUCT USER GUIDE
Product Overview
The PRTemp140 is a pressure and high temperature data
logger all in one, created specifically for use in autoclave
validation, mapping studies and pressurized processes.
Featuring the familiar body style of the 140 series of
data loggers and made of rugged stainless steel, this dual
purpose device is less than 2.5 inches in length, allowing
it to fit discretely inside small spaces. The PRTemp140 is
able to measure and record temperatures from -20 °C to
140 °C, and pressure from 0 bar to 5 bar, accommodating
a wide range of applications even in the harshest
conditions.
Water Resistance
The PR140 is fully submersible and is rated IP68. It can be
placed in environments with up to 230 ft (70 m) of water.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Connect the device
into a USB port with the interface cable. The drivers will
install automatically.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running,
Waiting to Start or Waiting to Manual Start,
depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download. You will be prompted to
name your report.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
PRTemp140
PRODUCT USER GUIDE
Device Operation (cont’d)
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device
desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
O-Rings
O-ring maintenance is a key factor
when properly caring for the PR140.
The O-rings ensure a tight seal and
prevent liquid from entering the
inside of the device. Please refer to
the application note O-Rings 101:
Protecting Your Data, found at
madgetech.com, for information
on how to prevent O-ring failure.
Battery Replacement
Materials: ER14250MR-145 Battery
1. Unscrew the bottom of the logger and remove the
battery.
2. Place the new battery into the logger. Note the polarity
of the battery. It is important to insert the battery with
positive polarity pointing upward towards the probe.
Failure to do so could result in product inoperability or
potential explosion if exposed to high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C
(284 ºF). Please heed the battery warning. The
product will explode if exposed to temperatures
above 140 °C (284 ºF).
PRTemp140
NEED HELP?
DOC-1309035-00 | REV 2 2020.06.12
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting:
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support:
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.

Other MadgeTech Data Logger manuals

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech EggTemp-RH Specification sheet

MadgeTech

MadgeTech EggTemp-RH Specification sheet

MadgeTech RFPRHTemp2000A Specification sheet

MadgeTech

MadgeTech RFPRHTemp2000A Specification sheet

MadgeTech CurrentX Series Specification sheet

MadgeTech

MadgeTech CurrentX Series Specification sheet

MadgeTech Volt101A User manual

MadgeTech

MadgeTech Volt101A User manual

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech

MadgeTech RFRTDTemp2000A Specification sheet

MadgeTech pHTemp101 User manual

MadgeTech

MadgeTech pHTemp101 User manual

MadgeTech MadgeNET RFTCTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNET RFTCTemp2000A Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech Pulse101A Specification sheet

MadgeTech

MadgeTech Pulse101A Specification sheet

MadgeTech RFCurrent2000A Specification sheet

MadgeTech

MadgeTech RFCurrent2000A Specification sheet

MadgeTech Event101A User manual

MadgeTech

MadgeTech Event101A User manual

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech CryoTemp Specification sheet

MadgeTech

MadgeTech CryoTemp Specification sheet

MadgeTech PR1000IS Series Specification sheet

MadgeTech

MadgeTech PR1000IS Series Specification sheet

MadgeTech Level1000 Specification sheet

MadgeTech

MadgeTech Level1000 Specification sheet

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech AVS140-1 Specification sheet

MadgeTech

MadgeTech AVS140-1 Specification sheet

MadgeTech PRTC110 User manual

MadgeTech

MadgeTech PRTC110 User manual

MadgeTech UltraShock-5-EB User manual

MadgeTech

MadgeTech UltraShock-5-EB User manual

MadgeTech OctProcessV2 Specification sheet

MadgeTech

MadgeTech OctProcessV2 Specification sheet

MadgeTech MicroTemp100 Specification sheet

MadgeTech

MadgeTech MicroTemp100 Specification sheet

Popular Data Logger manuals by other brands

Data Harvest EASYSENSE Q3+ user manual

Data Harvest

Data Harvest EASYSENSE Q3+ user manual

Dostmann Electronic LOG100 manual

Dostmann Electronic

Dostmann Electronic LOG100 manual

Fluke 1742 quick start guide

Fluke

Fluke 1742 quick start guide

Hi-Target Qmini M series manual

Hi-Target

Hi-Target Qmini M series manual

Fimer VSN700 product manual

Fimer

Fimer VSN700 product manual

Teac es8 user manual

Teac

Teac es8 user manual

EUPRY DW1T user guide

EUPRY

EUPRY DW1T user guide

Hydrotechnik MultiHandy 3020 operating instructions

Hydrotechnik

Hydrotechnik MultiHandy 3020 operating instructions

Geosignal XV 100 user manual

Geosignal

Geosignal XV 100 user manual

ATS Accu-Time 3610 Series manual

ATS

ATS Accu-Time 3610 Series manual

Dostmann Electronic OPUS20E operating manual

Dostmann Electronic

Dostmann Electronic OPUS20E operating manual

Perfect Prime TC0520 K instruction manual

Perfect Prime

Perfect Prime TC0520 K instruction manual

GREISINGER GMH 5150 operating manual

GREISINGER

GREISINGER GMH 5150 operating manual

LogTag USRIC-8 quick start guide

LogTag

LogTag USRIC-8 quick start guide

TESTO 175 instruction manual

TESTO

TESTO 175 instruction manual

Agbar Musa iMeter IMI-40-E manual

Agbar

Agbar Musa iMeter IMI-40-E manual

Measurement Computing USB-7204 user guide

Measurement Computing

Measurement Computing USB-7204 user guide

XC-Tracer Maxx user manual

XC-Tracer

XC-Tracer Maxx user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.