- 3 -
1.0 Introduction
Thank you for choosing our products. We
recommend that these instructions be used to ensure
the safe operation of the boiler and to maximise their
performance.
The data plate for the boilers is located behind the
control panel cover.
Boiler names:
Mital - wall hung gas-fired combination boiler with fan
assisted flue; output 23.2 kW.
Mital plus - room sealed wall hung gas-fired
combination boiler with fan assisted flue and
electronic ignition; output 23.2 kW.
Mital max - room sealed wall hung gas fired
combination boiler with fan assisted flue and
electronic ignition; output 31.3kW.
Montreux - wall hung gas-fired system boiler with fan
assisted flue; output 23.2 kW.
Montreux plus - room sealed wall hung gas-fired
system boiler with fan assisted flue and electronic
ignition; output 23.2 kW.
Montreux max - room sealed wall hung gas-fired
system boiler with fan assisted flue and electronic
ignition; output 31.3 kW.
2.0 General Precautions
•This instruction manual is an integral and
essential part of the appliance, and must be left
with the end user and stored near to the boiler for
further consultation during maintenance etc.
•These instructions must be read thoroughly before
proceeding, failure to follow the instructions may
affect the safety, performance and warranty of the
appliance.
•Installation must be carried out by professional,
qualified CORGI REGISTERED ENGINEERS in
compliance with all current regulations and
manufacturers instructions.
•The installation of the boiler must also be in
accordance with the current I.E.E. Regulations,
the By-laws of the Local Water Undertaking, Local
Authority requirements and all relevant British
Standards.
•The appliance must be installed in a suitable
environment that is NOT explosive, flammable,
corrosive or damp.
•Neither the supplier or the manufacturer will be
responsible for any damage to property, persons,
animals or the boiler, as a result of tampering,
improper use, installation or maintenance.
•Packaging parts (i.e. plastic bags, polystyrene,
wood, clips, nails, etc.) can be harmful to
children and must be disposed of immediately
and correctly.
•To avoid damage caused by low temperatures it is
recommended that the boiler should be drained
down if left unused for a long period. Neither the
supplier or manufacturer is responsible for faults,
break downs, water leakage or any consequential
damage caused by low temperature.
•To comply with the Warranty these instructions
must be adhered to and only original spare parts
and kits used.
•In the event of breakdown the appliance should be
isolated and a qualified CORGI REGISTERED
SERVICE ENGINEER contacted.
•This appliance MUST have an annual service and
inspection by a suitably qualified CORGI
REGISTERED ENGINEER.
3.0 Installation
3.1 Reference Regulations
Detailed recommendations are contained in the
following :
BS 5440 :1 & 2, BS 4543, BS 5540 :2, BS 6798, BS
5449, BS 5546, BS 6891, Gas Safety Regulations
1984. All other relevant regulations must be
adhered to whether they are listed above or not.
3.2 Packaging
The packing material and the cardboard cover must
be removed without turning the boiler upside down.
The boiler should be kept in a vertical position
and on the polystyrene lower base. Never place
the boiler directly onto the floor.
To remove the cardboard cover open the base of the
box and lift the box off the boiler.
Each boiler is supplied in three separate containers:
1. boiler
2. connection manifold, valves and angled
connecting pipes.
3. flue kit
any extras or additions will be packed separately.
3.3 Boiler Location
Mital & Montreux - Both these appliances are NOT
ROOM SEALED and therefore must NOT be
installed in a bedroom, bedsitting room or any room
containing a bath or a shower.
These boilers must be sited 0.5 metres from
combustible materials i.e. curtains etc.
Mital plus, Mital max, Montreux plus & Montreux
max are room sealed and can be installed in any
room, although particular attention is drawn to the
requirements of the IEE Regulations and, in
Scotland, the electrical provisions with respect to the
installation in a room containing a bath or shower.
If the boiler is to be installed in a room that
contains a bath or shower the boiler MUST be