STUDIODUE CITYCOLOR 2500 User manual

6TFSTBOEPQFSBUPSTNBOVBMGPSBSUt
.BOVBMFEVTPFEFMMPQFSBUPSFQFSBSUt
PATENT WO99/40361
*1t


Safety informations ........................................................................................................................... page 2
Technical features.............................................................................................................................. page 3
Before using....................................................................................................................................... page 4
Lamp installation, replacement and setting .................................................................................... page 5
Installation of the dust proof filters .................................................................................................. page 6
Control panel and configuration...................................................................................................... page 7
Programming functions .................................................................................................................... page 8
Use of the CityColor in DMX 512 ..................................................................................................... page 9
DMX signal connection..................................................................................................................... page 10
DMX line and termination ................................................................................................................ page 11
Automode functioning ...................................................................................................................... page 12
Troubleshooting ............................................................................................................................... page 13
System board connection ................................................................................................................ page 15
Electric diagrams .......................................................................................................................... page 17
Components and parts...................................................................................................................... page 22
Technical drawings............................................................................................................................ page 23
Appendix A (DMX values)................................................................................................................. page 26
Appendix B (games).......................................................................................................................... page 27
PATENT WO99/40361
*1t
ENGLISH INDEX

2
rel. 7-0308
WARNING
INTRODUCTION
Thank you for using our flood projector CityColor.
The CityColor projects, thanks to an extremely efficient optic system (patent n. WO99/40361), a powerful light beam which can create
numberless color shades. Its performances, in terms of luminousity and lighted surfaces, can reach incredible levels.
The CityColor IP54 comes in the following versions:
t"SU$*5:$0-03*18
t"SU $*5:$0-03*18)JHI1PXFS
The CityColor can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers
The input protocol is the DMX 512. To drive the CityColor we suggest to use either our controller DMX Control Spot, the
Control Show 512 the Easy Control or the Fancy.
To make the most of its possibilites and for a correct functioning of this unit in the years to come, we suggest you to read carefully
this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and connections
and you will be easily able to use it.
Check that the spot has not been damaged during transport. If it has been damaged or it does not work, address
the seller. Whether the spot has been shipped to you directly, please contact the shipping company.
Only the consignee (person or company) can claim for these damages.
!
WARNING
!SAFETY INFORMATION
READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.
INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS,
UV RADIATION HAZARDS AND DANGEROUS MATTERS.
t1305&$5*0/"("*/54'*3&
1)This equipment is designed for use with the following lamps only:
1IJMJQT.)/4"8F1IJMJQT.4"%&8
DO NOT USE ANY OTHER TYPE OF LAMP!
2) Maintain minimum distance of 0.5 meter from walls or any other type flammable surfaces.
3) Maintain minimum distance of 2.0 meter to lighted objects .
3FQMBDFGVTFTPOMZXJUIUIFTQFDJmFEUZQFBOESBUJOH
5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.
t1305&$5*0/"("*/45&-&$53*$4)0$,
1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) Disconnect power before installing the lamp or servicing (service personnel).
t1305&$5*0/"("*/45.&$)"/*$"-)";"3%4
1) Use secondary safety chain when fixing this equipment.
)PUMBNQFYQMPTJPOIB[BSE%POPUPQFOUIFFRVJQNFOUGPSTFDPOETBGUFSTXJUDIJOHPGG
3) Equipment surface may reach temperature up to 100°C. Allow about five minutes before handling.
3FQMBDFUIFMBNQJGJUJTEBNBHFEPSUIFSNBMMZEFGPSNFE
t1305&$5*0/"("*/45673"%*"5*0/)";"3%4
1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged.
2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
has been reduced, for example, by cracks or deep scratches. Part 140/a, code SDO52000015
3) Do not look directly at the lamp while lamp is on.
t1305&$5*0/"("*/45%"/(&3064."55&34
At the end of its working life, the product must not be disposed of as urbamn waste. It must be taken to a special local
authority differentiate waste collection centre or to a dealer providing this service. The wrong disposal must be cause of
environment and people damages in the presence of possible dangerous matters. There are provided for sanctions to a
VOBVUIPSJ[FEEJTQPTBMPGUIFTFQSPEVDUT
2m
F

3rel. 7-0308
YOUR REFERENCE
Always remember to give the serial number and to specify the model any time you address the seller for information or assistan-
ce.
BASIC KIT
The basic kit of the CityColor flood projector consist of:
t1SPKFDUPS
t6TFSTNBOVBM
t1PXFSDPOOFDUPS
t4UVEJP%VFXBSSBOUZ
Available on request:
tBSUBCBSOEPPSUPEFmOFJMMVNJOBUFETVSGBDF
tBSUBBOUJHMBSF
tBSUB9-3QJONBMF*1DPOOFDUPST
tBSUC9-3QJOGFNBMF*1DPOOFDUPST
t-BNQ
TECHNICAL FEATURES
tLAMPS
.)/4"81)*-*14BSU
Color temperature: 5.600°K
Lamp life: 2.500 hours
Luminous flux 180.000 lm
t015*$$0-034:45&.
'VMM$:.DPMPSNJYJOHVOMJNJUFEWBSJFUZPGDPMPVSTBOETIBEFT)JHISFTPMVUJPOTUFQQFSNPUPST
Shutter + dimmer. The color changer can be drived with 4 different speeds or in real time.
tBEAM ANGLE: (50% intensity) 50°x52°
t$0/530-*/165
SUBOEBSEJOUFSGBDF34PQUPDPVQMFUJOQVU
Protocol: USITT DMX 512
t4&561"/%$0/'*(63"5*0/
On the control panel with menu and buttons
tAUTOMODE
Stand-alone control: auto mode function master/slave (synchro mode) with 27 programs
t*13"5&*1
t108&34611-:: (art. 0002) magnetic ballast
3BUFEWPMUBHF7~)[
0OSFRVFTU7~)[7~)[7~)[7~)[
3BUFEDVSSFOU"!7~
3BUFEQPXFS8
t108&34611-:: (art. 0003) magnetic ballast
3BUFEWPMUBHF7~)[
0OSFRVFTU7~)[7~)[7~)[7~)[
3BUFEDVSSFOU"!7~
3BUFEQPXFS8
t108&3'"$503$033&$503 built-in cos Ø 0.9
t%.9$)"//&-4
ch1 = motors speed
ch2 = cyan
ch3 = yellow
ch4 = magenta
tDIMENSIONS (wxdxh)
mm 780x560x740
t8&*()5
art. 0002: 56 kgs. net
art. 0003: 69 kgs. net
.4"%&81)*-*14BSU
Color temperature 6.000°K
Lamp life 2.000 hours
Luminous flux 260.000 lm
ch5 = dimmer
ch6 = basic colors + rainbow
ch7 = remote reset/lamp off

4
rel. 7-0308
BEFORE USING
3FBEBMMDBVUJPOTBOEXBSOJOHTUPQBHFQSJPSUPJOTUBMMUIJTFRVJQNFOU1BSUJDVMBSMZSFBEUIFGPMMPX
%JTDPOOFDUQPXFSCFGPSFMBNQTSFQMBDFNFOUPSTFSWJDJOHTFSWJDFQFSTPOOFM
2) Do not open the lamp cover for 300 seconds after switching off
3) Wear gloves and goggles to re-lamping or to work inside the unit (service personnel)
Before connecting the equipment to the power system: make sure that the mains voltage and frequency correspond to rated
values.
t5IF$JUZ$PMPSDBOCFFRVJQQFEGPSBNBJOTWPMUBHF7~)[
POSFRVFTU7~)[7~)[7~)[7~)[
'PSBQPXFSTVQQMZPG7~7~it is necessary to use one auto transformer with the following features:
t0VUQVUWPMUBHF7~
t0VUQVUDVSSFOU"!7~(for art. 0002)
t0VUQVUDVSSFOU"!7~ (for art. 0003)
The power supply cords construction is shown in pict.1. For connection to the mains supply proceed as pict.1.
5IFFRVJQNFOUNVTUCFDPOOFDUFEUPCSBODIDJSDVJUIBWJOHBDJSDVJUCSFBDLFS*O"t*E"7~) (art. 0002) or
*O"t*E"7~) (art.0003)
a) Do not install the spot close to the heat sources. Observe minimum distance between the spots of 1.5 meters. Do not lay the
connection cable on the spot when it is warm.
b) This unit must be positioned as to allow its ventilation. Be careful not to acclude the in-out ventilating grilles.
c) The unit must be positioned at least 50cm. from walls or other flammable surfaces.
d) Observe minimum distance to lighted objects of 5 meters.
External surface temperature Ta 35°C:
t"GUFSNJOVUFTXPSL5D×$
t0ODFUIFUIFSNJDCBMBODFIBTCFFOPCUBJOFE5D×$
4) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
has been reduced, for example, by cracks or deep scratches.
5) The lamp must be replaced if it has been damaged or thermally deformed.
6) Clean regularly the in-out ventilating grilles.
7) Do not handle the spot by taking it by the head, but always by using the special handles.
WARNING
!
IP 67 pict.1
The equipment must be earthed.
IP 54 rate: the equipment must be installed on the horizontal plane.
*/165$0//&$503
'038
*/165$0//&$503
'038)*()108&3
IP 67
1*/$0//&$503'03108&3*/165
/ /&653"-
- -*7&
(306/%
CONDUCTOR SIZES (length < 20mt.)
."*/470-5"(& $30444&-&$5*0/"-"3&"4
7 3X1,5 mm2(minimum)
CIRCUIT BREAKER
."*/470-5"(& In Id
7 32A 0,03A
Studio Due CITYCOLOR art. 0002
Keep at least a distance of 0,5 mts between the apparatus and
inflammable surface nearby.
Disconnect the unit from power before servicing.
230Vac; 15A - 50Hz SN QC

5rel. 7-0308
C
D
E
C
INSTALLATION OF THE DISCHARGE LAMP
(see pic.2)
%JTDPOOFDUQPXFSCFGPSFMBNQTSFQMBDFNFOU8FBSHMPWFTBOEHPHHMFT
3FNPWFDPNQMFUFMZUIFQPNNFMT"POUIFCBTFPGUIFIFBE
3) Open the base of the lamp room (G)
3FNPWFUIFUXPMBUFSBMSFnFDUPST$
5) Lift up the two lampholder (D)
6) Install the new lamp. Taking care that protuberance of the bulb is set towards the reflector
Do not touch the quarz bulb with fingers. If this happenes, clean the bulb before use with dry cloth and alcohol.
7) Put down the two upper lampholders (D)
8) Connect the cables (E) to the two ends of the lamp or connect the two cables of the lamp to the two red insulators on the rear
panel of the head.
9) Put in again the two lateral plane reflectors.
10) Close the rear panel and install again the two pommels (A) and hold them tightly.
In case of replacement of the lamp or maintenance, do not open
the fixture unless 5 minutes have passed from the switching off.
This operation has to be done when the apparatus is disconnected
from the mains supply
WARNING
!
pict.2
A
G

6
rel. 7-0308
pict.3
WARNING
!
IP RATE
The declared IP rate of the CityColor comes supported at these conditions:
tUIFJOTUBMMBUJPOPGUIFmYUVSFPOBXJEFBOETUBCMFTVSGBDF
tUIFBJSDPPMJOHJOQVUBOEPVUQVUBSFMPDBUFEPOUIFCBTFPGUIFTJEFTIFMM
it is not possible to install the fixture outdoor with the ballast upwards
tZPVNVTUVTFUIFmMUFSTVQQMJFEXJUIUIFCBTJDLJUGPSUIF*13"5&
The CityColor has a IP rate 44 without filters installed and an IP RATE 54 with filters installed.
You must use the filters in critical working conditions and, normally, when the fixture works outdoor.
You must remove the filters when the ambient temperature is over 35°C.
You must regularly clean the filters to allow the correct cooling of the fixture.
You must remove the two side protective shells. The
two filters must be assembled on the bulkheads at the
bottom of the side brackets.
Pay attention to the installation: dust proof filters
must stick correctly to prevent the entrance of the
dust. You must control that the two filters comple-
tely cover the overall of the air entrance.
INSTALLATION OF THE DUST PROOF FILTERS
WARNING
!You must operate with power supply disconnected from the fixture

7rel. 7-0308
pict.4
CONTROL PANEL
On the control panel of the CityColor (pict.4) you can find, besides the display, the leds and the buttons to use to set the spot.
LED
ti%.9wMFE nBTIJOH %.9JOQVUQSFTFOU
off: no DMX input
tw-".1wMFE nBTIJOH UIFMBNQTXJUDIJOHPGGJTSFNPUFMZDPOUSPMMFE
off: lamp switched on
tw%*..&3wMFE nBTIJOH UIFMBNQJTEJNNFSFE
off: lamp switched on
BUTTONS
Four buttons are used to programme the spot:
t.&/6 UPTFMFDUUIFQSPHSBNNJOHPQUJPOT
tDOWN to go backward in the selected options
tUP to go forward in the selected options
t&/5&3 to confirm the selected options
DISPLAY
Shows the various menus and the selected options.

8
rel. 7-0308
"CPVUUXFOUZTFDPOETBGUFSUIFTXJUDIJOHPOUIFOVNCFSPGUIFTPGUXBSFWFSTJPOXJMMCFTIPXOPOUIFEJTQMBZJOi9@wGPSNBU
Afterwards the first of the eight available menus will appear:
Addr to assign the DMX-512 address
Mode DMX512 mode, master with pre-set selection, slave
LHrS lamp working hours
FHrS fixture total working hours
nChn channels number
teSt auto-test
FLIP display inversion
rSEt reset of the spot
To select any of the given options, press the MENU button up to when the required one is shown.
Addr (Address)
5PWJTVBMJTFUIF%.9BEESFTTQSFTT&/5&3
5PNPEJGZUIFBEESFTTQSFTT%PXOBOE6QCVUUPOTBOEPODFUIFSFRVJSFEBEESFTTIBTCFFOTFMFDUFEQSFTTBOELFFQ&/5&3QSFTTFE
up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). To go back to
the options without making any change, press the MENU button.
Mode (Mode)
5PWJTVBMJTFUIJTNPEFQSFTT&/5&3
6TF%PXOBOE6QCVUUPOTUPDIBOHFUIFNPEFBOEPODFUIFSFRVJSFEPOFIBTCFFOTFMFDUFEQSFTTBOELFFQ&/5&3QSFTTFEVQ
to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). The available
PQUJPOTBSFOPOPSNBMGPSUIFGVODUJPOJOHJO%.9SFDFQUJPO1Sy1SQSFTFUyGPSUIFNBTUFSGVODUJPOJOHXJUIUIFSF-
spective game, SL (slave) for the functioning as slave. To go back to the options without any change, press the MENU button.
LHrS -BNQ)PVST
5PWJTVBMJTFUIFOVNCFSPGXPSLJOHIPVSTPGMBNQQSFTT&/5&3
The maximum countable number of hours is 3000. Exceeding this number, the display will show gr3t (greater than 3 thousands).
5PSFTFUUIFDPVOUFSQSFTTTJNVMUBOFPVTMZCVUUPOT%PXOBOE61UIFEJTQMBZXJMMTIPX$--)DMFBSMBNQIPVST5PHPCBDLUPUIF
options without making any change, press the MENU button.
FHrS (Fixture hours)
5PWJTVBMJTFUIFOVNCFSPGXPSLJOHIPVSTPGmYUVSFQSFTT&/5&3
The maximum countable number of hours is 3000. Exceeding this number, the display will show gr3t (greater than 3 thousands). To
reset the counter press simultaneously buttons Down and UP. A control of the memory will be run and all the default settings will be
stored: the display will then show Init. If the memory is damaged, the display will show the message FAIL. To go back to the options
without making any change, press the MENU button.
Addr nChn
teSt
FLIP
rSEt
Mode
LHrS
FHrS
SUMMARY OF THE PROGRAMMING FUNCTIONS OF THE CITYCOLOR

9rel. 7-0308
WARNING
!
DRIVING THE CITYCOLOR WITH A DMX REMOTE CONTROLLER
t4FMFDUUIFSFRVFTUFE%.9TUBSUJOHBEESFTTCZPQFSBUJOHPOUIFAddr option
t4FMFDUUIFSFRVFTUFEOVNCFSPGDIBOOFMXJUI/$IOPQUJPO
t$POOFDUUIF%.9TJHOBMCFUXFFOUIFmYUVSFBOEUIFDPOUSPMMFS
t$IFDLUIBUUIF%.9MFEJTnBTJOH%.9TJHOBMQSFTFOU
t*GUIFSFJTOPTJHOBMZPVNVTUNBOVBMMZSFTFUCZPQFSBUJOHPOUIF3&4&5 option
It is possible to choose a standard configuration occupying 6 DMX channels, or a enanched configurationoccupying 7 channels.
Use the enanched configuration if you want to activate channel 7 which enables the reset of the motors and the switching off of
the lamp from the controller.
6/7 CHANNELS MODE SELECTION
1SFTTUIF.&/6CVUUPOPOUIFDPOUSPMQBOFMVQUPXIFOUIFPQUJPOO$IOJTTIPXOPOUIFEJTQMBZTFMFDUJUCZQSFTTJOH&/5&3
and the set indication will appear (6 or 7 channels). If you want to activate channel 7 you must set 6 channels on the display. Pass
through the numbers by pressing the buttons UP and DOWN: once you have set the required number, store it by pressing the
&/5&3CVUUPOBOELFFQJUQSFTTFEVQUPXIFOUIFEJTQMBZTUPQTnBTIJOHUIFnBTIJOHTIPXTUIBUUIFTFMFDUFEPQUJPOJTEJGGFSFOU
from the one previously stored). To exit from the selected option without making any change press the MENU button.
)FSFCFMPXJTTIPXOUIFDPNQMFUFMJTUPGUIFGVODUJPOTPGUIF$JUZ$PMPS
5IFDPNQMFUFMJTUPGUIF%.9WBMVFTDBOCFGPVOEJOBQQFOEJYi"wQBHF
$)"//&-4 $)"//&-4
$) .PUPSTQFFE $) .PUPSTQFFE
$) $ZBO $) $ZBO
$) :FMMPX $) :FMMPX
$) .BHFOUB $) .BHFOUB
$) %JNNFS$) %JNNFS
$) #BTJDDPMPSTSBJOCPX $) #BTJDDPMPSTSBJOCPX
$) 3FNPUFSFTFU-BNQPGG
nChn (Number of Channel)
5PWJTVBMJTFUIFOVNCFSPGDIBOOFMQSFTT&/5&3
6TF%PXOBOE6QCVUUPOTUPDIBOHFUIFDIBOOFMBOEPODFUIFSFRVJSFEPOFIBTCFFOTFMFDUFEQSFTTBOELFFQ&/5&3QSFTTFE
up to when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible
to set 6 channels or 7 channels ( remote reset and remote lamp switch off ). To go back to the options without making any change,
press the MENU button.
teSt (Autotest)
5PJOTFSUUIFBVUPUFTUQSFTT&/5&3BOELFFQJUQSFTTFEVQUPXIFOUIFEJTQMBZTIPXTUIFnBTIJOHNFTTBHFUPOUFTUPO5PUBLF
off the auto-test press the MENU button. To go back to the options without making any change, press the MENU button.
FLIP (Display overturning)
5IFEJTQMBZWJTVBMJTBUJPODBOCFTUBOEBSEPSPWFSUVSOFECZQSFTTJOHUIF&/5&3CVUUPOUIFUXPNPEFTXJMMCFBMUFSOBUJWFMZWJTJCMF
The selected one will be immediately stored in the spot setting.
To go back to the options without making any change, press the MENU button.
rSEt3FTFU
5PSVOUIFDPNQMFUFSFTFUQSFTT&/5&3BOELFFQJUQSFTTFEVQUPXIFOUIFEJTQMBZTIPXTUIFnBTIJOHNFTTBHFSPOSFTFUPO
Once the reset procedure has been completed the spot will go back to the normal setting. To go back to the options without mak-
ing any change, press the MENU button.
When using CYM color mixing, the basic colors channel # 6 must be set at: 00=DMX value

10
rel. 7-0308
pict.5
pict.5a
CONNECTION THE DATA LINK (DMX 512)
5IFDPOOFDUJPOPGUIF%.9TJHOBMUPUIF$*5:$0-03NVTUCFNBEFCZVTJOHUIFTJHOBMJOQVU9-3QJODPOOFDUPSTXIJDIBSFMPDBUFE
on the control panel of the fixture. (pict.5)
The pin nomenclature of the connectors for the connection to the DMX signal is listed in the table. (pict.5a)
In order to avoid any problem in the signal transmission, it is warmly suggested to use a cable for high speed data transmission
(sect. > 2x0.25 + gnd).
If the lines have a total length over 150-200 mts it is suggested to use a signal amplifier (art. 3004 - DMX repeter amplifier).
The usage of a normal microphonic or audio cable is suggested only for lines max 100 mts long.
To ensure the IP54 rate you must connect the DMX cable inside the base. Use the given cables fixing (pict. 5b) and connect by
following the cables numbering (pict. 5c).
fig.5c
fig.5b
PIN WIRE SIGNAL
14)*&-% (306/%3&563/07
2*//&3$0/%6$503 %"5"$0.1-&.&/5*/7&35&%
3*//&3$0/%6$503 %"5"536&/0/*/7&35&%

11 rel. 7-0308
5&3.*/"-3&4*4503
%.9$0/530--&303-*()5
CONSOLE
5&3.*/"-3&4*4503
LAST SPOT
SPOT
EXAMPLE 2
Connection controller-spot to one DMX 512 output over 150mts long
4*(/"-".1-*'*&3
LINE > 150mts (with microphonic or audio cable)
DMX TERMINAL LINE
The wrong connection of the terminal line or its non-connection are probably the most frequent reasons for the defective functioning
PGUIF%.9MJOF5IFUFSNJOBUPSJTBSFTJTUPSmUUFECFUXFFOUIFUXPiEBUBwMJOFTQJOTBOEPGBO9-3QJODPOOFDUPSBUUIFFOE
of the cable furthest from the transmitter. The terminator resistor should have the same value as the impedance of the connection
cable.
We supply a terminal with a 100 Ohm resistor.
It is recommanded that all DMX 512 systems have the termination resistor at the and of the line.
%.9$0/530--&303-*()5
CONSOLE
EXAMPLE 1
Connection controller-spot with 1 DMX 512 output
LAST SPOT
SPOTSPOT SPOT
WARNING
!
pict.6
5&3.*/"-3&4*4503

12
rel. 7-0308
The cables are the same as the DMX standard cable
WARNING
!
."45&3
USE OF THE CITYCOLOR IN AUTO-MODE
"TIPSUMJTUPGUIFHBNFTDBOCFGPVOEJOBQQFOEJYi#wQBHF
Press the MENU button on the control panel up to when the option MODE (pict. 7) is shown on the display, select it by pressing
&/5&3BOEUIFTFUJOEJDBUJPOXJMMBQQFBSOP4-6TF%PXOBOE6QCVUUPOTUPDIBOHFUIFNPEFBOEPODFUIFSFRVJSFEPOFIBT
CFFOTFMFDUFEQSFTTBOELFFQ&/5&3QSFTTFEVQUPXIFOUIFEJTQMBZTUPQTnBTIJOHJUnBTIFTUPJOEJDBUFUIBUUIFTFMFDUFEPQUJPO
JTEJGGFSFOUGSPNUIFQSFTFUPOF5IFBWBJMBCMFPQUJPOTBSFOPOPSNBMGPSUIFGVODUJPOJOHJO%.9SFDFQUJPO1Sy1SQSFTFU
yGPSUIFNBTUFSGVODUJPOJOHXJUIUIFSFTQFDUJWFHBNF4-TMBWFGPSUIFGVODUJPOJOHBTTMBWF
To go back to the options without any change, press the MENU button.
Mode no use of the CityColor in DMX-512
Pr1..Pr27 master functioning with execution of the 27 stored programme
SL VTFPGUIF$JUZ$PMPSJO4-"7&.0%&
pict.7
EXAMPLE OF CONNECTION AND SETTING OF 4 CITYCOLOR IN SYNCHRO - MODE
EXAMPLE OF CONNECTION AND SETTING OF 4 CITYCOLOR IN INDIPENDENT AUTO - MODE
."45&3 4-"7& 4-"7& 4-"7&
."45&3 ."45&3 ."45&3 ."45&3

13 rel. 7-0308
GENERAL TROUBLESHOOTING
"QQFOEJYi$wt5BCMF"
TROUBLESHOOTING GUIDE
Before calling for technical assistance, follow the recommended procedures in this appendix to solve many problems on your fix-
ture.
$"65*0/t#&'03&:06#&(*/
Before you perform any troubleshooting procedures read the following personnel and equipment safety precautions:
3FGFSTFSWJDJOHUPTFSWJDFQFSTPOOFM25RVBMJmFEUFDIOJDJBOOPVTFSTFSWJDFBCMFQBSUTJOTJEF
2) Wear hand and eye protection
3) Wait at least five minutes before accessing the lamp after operation
%JTDPOOFDUUIFVOJUGSPNQPXFSCFGPSFSFNPWJOHBOZDPWFS25
If the procedures do not solve your problem and you need to call for assistance, please provide the support technician with the
follow information:
t$VTUPNFSOBNF
t1IPOFOVNCFSBOEGBYOVNCFS
t'JYUVSFTFSJBMOVNCFS
t.FTTBHFUIBUBSFZPVEJTQMBZFEPOZPVS$JUZDPMPSEJTQMBZ
t%FTDSJQUJPOPGUIFQSPCMFNBOEUIFUSPVCMFTIPPUJOHQSPDFEVSFTUIBUZPVIBWFQFSGPSNFETPGBSUPEJBHOPTFBOESFTPMWFUIF
fault.
:PVDBODPOUBDUZPVSBVUIPSJ[FE456%*0%6&EFBMFSPSEJSFDUMZ456%*0%6&5FDIOJDBM4FSWJDF
UFMPSGBYFNBJMTFSWJDF!TUVEJPEVFDPNPSDVTUPNFS!TUVEJPEVFDPN
14

14
rel. 7-0308
DATA LINK (512 DMX) TROUBLESHOOTING
"QQFOEJYi$wt5BCMF"
14

15 rel. 7-0308
MAIN BOARD CONNECTION
LED
7%$
-&%7
6.*$30."45&3.0503
$$%3799
6.*$304-"7&.0503
$$4-"7&99
-&%7
TO BASE FAN
50)&"%'"/
73*7"3*45037
07&370-5"(&1305&$5*0/
MOT2
%*..&3
MOT5
$:"/
U12
7805
7
50)&"%
5)&3."-4&/403
"/%48*5$)
."*/108&3
INPUT
TO CC250
TO PCB
CC250
MOT4
:&--08
66666-.0503%3*7&3
6 .*$30 18.
'"/$0/530--&3
MOT3
MAGENTA
50-".1#09$:.#09
4"'&5:48*5$)
LED DMX
SIGNAL
-&%70150%.9
U13 78M05
OPTO DMX
50%*41-":
PCB PAN IP
67*1&348*5$)*/(
108&34611-:%3*7&3
C65
D3
%0''-*/*%(&
3&$5*'*&3

16
rel. 7-0308
MOTORS BOARD
t108&34611-:7-FE0O
t7-FE
t7-FE
t7%.9-FE
t%.9TJHOBM
Led flashing:the DMX signal is operating on the board
Led off: check the U1 (6N137) and the DMX connecting cable (from PCB PAN IP)
t45&11&3.0503DIBOOFMOPUXPSLJOHJF:&--08
4XJUDIPGGUIFmYUVSFBOEEJTDPOOFDUUIF:&--08BOE$:"/DBCMFT
$POOFDUUIF:&--08DBCMFPOUIF$:"/DPOOFDUPS
3) Switch on the fixture:
B*GUIF:&--08NPUPSXPSLTOPSNBMMZJUJTOFDFTTBSZUPSFQMBDFUIF6-
3b) If the motor is still not working check with extreme attention the motor and the interconnecting circuits (cables and
connectors). To check the cables and the motors you can measure the resistance as follows:
CFUXFFO1*/BOE1*/PO*$6S_PINCFUXFFO1*/BOE1*/PO*$6S_PIN
t*GUIFMFE70150%.9JTPGG
%JTDPOOFDU50%*41-":1$#1"/*1DPOOFDUPSJGUIFMFEJTPODIFDL1$#1"/*1
2) Check U13 (78M05), L3, D6
t*GUIFMFE7JTPGG
%JTDPOOFDU50%*41-":1$#1"/*1DPOOFDUPSJGUIFMFEJTPODIFDL1$#1"/*1
2) Check D4, L2, U12
t*GUIFMFE7JTPGG
$IFDLJGUIFMFE7JTPOJGJUJTPL
1a) Check if U11 is in thermal drift (ATTENTION on the heat dissipator there is dangerous tension!!!!)
C$IFDLJG66666BSFJOTIPSUDJSDVJU4XJUDIPGGUIFmYUVSF3FNPWFBMMUIFDIJQTGSPNUIFTPDLFU
Switch on the fixture: if the led is on, insert the chips one by one in the sockets to find out which is in short-circuit.
1c) Check D3
1d) If all the operations described above have not given any positive result, change U11
*GUIFMFE7JTPGGUPHFUIFSXJUIUIFMFE7
B$IFDLUIF."*/108&3*/165XIFSFZPVDBONFBTVSFUIFXPSLJOHWPMUBHF
C$IFDLUIFNBJOGVTFJGJUJTCMPXODIFDL73OPSNBMMZJUIBTBSFTJTUBODF∞). If it is in short circuit you must change it.
D$IFDL%#SJEHF3FDUJmFSJGJUJTPLDIFDL$
2d) If the fuse is still blown, change U11