Suitmate Swimsuit Water Extractor User manual

INSTALLATION
The SUITMATE®Swimsuit Water Extractor has been designed and manufactured with safety as
our primary consideration. Therefore, it is important that the unit be installed correctly. It is also
important that the installation comply with all local building codes and regulations. Please consult
your local licensed plumbing and electrical engineers or contractors about your installation. Read
the entire INSTALLATION instructions before beginning your installation. Remember: DO IT
RIGHT and DO IT SAFE!
PROPER LOCATION FOR THE SUITMATE®
Following is a list of factors to consider in determining a location for the SUITMATE®.
1. The unit should be located in an area that is near where people remove and rinse out their
swimsuits.
2. The unit should NOT be located in a cluttered area or where it is exposed to direct shower
water or water hose down.
3. The unit should be mounted on a wall structure that will support the unit’s approximate 60
pounds hanging weight plus the added weight or pressure of people leaning on the unit.
Consult the PROPER WALL MOUNTING section of these instructions to determine an
appropriate location.
4. There should be a means to dispose of the wastewater from the unit. Consult the PROPER
DRAINAGE section of these instructions to determine an appropriate location.
5. The unit should be wired to 115-volt (AC), 20-ampere 60Hz dedicated circuit. Consult the
PROPER ELECTRICAL CONNECTIONS sections of these instructions to determine proper
location.
PROPER WALL MOUNTING OF THE SUITMATE®
The SUITMATE®should be mounted to the wall with the Mounting Bracket that is provided with
the unit. The SUITMATE®UTILITIES LOCATION DIAGRAM (page 5) shows the recommended
location for the mounting holes, the electrical service, and the wastewater outlet (if utilized). The
SUITMATE®Mounting Bracket must be secured to a wall stud, or to concrete block or cinder
block wall.
TO WALL
MOUNTING
SCREWS
LAG
SCREWS
CHECKWITHLEVEL
WARNING! Anchors in drywall are not sufficient to mount the SUITMATE
®
.
Locating and Security the Mounting
Bracket to the Wall
The recommended height from the floor to the
top of the SUITMATE®is 42 inches. At least an
additional 10 inches of clearance above the
SUITMATE®is needed for the opening and
closing of the lid. This means that the top edge
of the Mounting Bracket should be 39 1/2 inches
from the floor. Use the SUITMATE®UTILITIES
LOCATION DIAGRAM to determine a location
on the wall that provides adequate clearance, a
strong and secure place for the Mounting
Bracket as well as easy access to electrical and
drainage connections.
115VAC 60 Hertz Installation Instruction

WARNING! The Mounting Bracket must be level after secured to the wall.
To secure the Mounting Bracket to a stud, center the Bracket on the stud and mark on the wall or
the stud the locations of the two vertical center holes of the Mounting Bracket. Drill the marked
locations with a 1/8-inch drill bit. Make certain the Mounting Bracket will be level after it is
secured to the wall. Reposition the Mounting Bracket over the two holes. Drill the outer two
holes to receive wall anchors. Install the wall anchors.
Secure the Mounting Bracket to the stud by using two 5/16 x 2 inch lag screws through the two
vertical center holes. Make certain the Bracket is level. Finish securing the Bracket with the
appropriate fasteners in the outer two holes. For mounting to concrete, etc., use at least four No.
10 or larger screws fastened into appropriate anchors. After the Bracket has been anchored to
the wall and the electrical and drainage requirements have been allowed for, the SUITMATE®is
ready to be mounted to the wall. Mounting the SUITMATE®to the Wall
Remove all packaging material from the
SUITMATE®including material around the Motor
and the shipping board on the bottom of the unit.
The upper back lip of the SUITMATE®should be
lowered down and centered on the Bracket.
After the unit is centered, push down on the
back of the unit to make certain that it is
securely wedged onto the Bracket. Make
certain the unit is level. If it is not level, remove
the unit, adjust the Mounting Bracket and re-
hang the unit. A level installation is necessary to
minimize vibration and insure proper drainage of
wastewater. Finish securing the unit to the wall
using appropriate fasteners and anchors on the
lower mounting channel at the bottom rear of the
unit. This will prevent the unit from being lifted
from the Bracket or being moved.
PRESS HERE TO FIRMLY
SET SUITMATE
UPPER
BACK
LIP
WALL
MOUNTING
BRACKET
EASE
UNIT
OVER
BRACKET
AND
LOWER
FLOOR
WALL
CUTAWAY VIEW OF SUITMATE
MOUNTING
SCREWS
PROPER DRAINAGE FOR THE SUITMATE®
Note: Strictly follow all applicable local plumbing codes and regulations.
To a Floor Drain
Drainage of the wastewater to a floor drain should be done ONLY IN an area where the floor is
normally wet. DO NOT drain water across a floor where people do not expect to encounter a wet
and slippery condition. SUITMATE®comes with a short flexible floor drain extension tube
connected with a stainless steel hose clamp to its drain tailpiece.
SUITMATE
®
The drain tube that comes with the unit must not be
removed unless the unit is connected to an approved wastewater outlet
or the factory-supplied tube is replaced with another tube according to
the following instructions.
WARNING!
Replacing the Factory Drain Tube with a Longer Drain Tube
Use a 1-1/4 inch I.D. drain tube with a smooth interior that will not crimp or collapse. Use the
stainless steel hose clamp that is provided with the factory flexible floor drain extension tube to
secure the replacement tube to the unit’s drain tailpiece. Run the drain tube so that it is never
higher than the bottom of the SUITMATE®and always slopes down. Secure the drain tube to the
wall or floor with properly sized “U” clamps so it cannot be maneuvered to trap wastewater. Cut
off the end of the drain tube on an angle to help prevent it from being blocked by the floor, wall, or
some other object. Upon completion of the installation, check to make certain that there is a free
flow of water from the drain tube extension.
115VAC 60 Hertz Installation Instruction

To an Approved Sanitary Waste Line
This installation should only be done in accordance with all applicable local plumbing codes and
regulations. The unit’s 1-1/4 inch O.D. drain tailpiece is designed for connection with standard
compression type plumbing fittings. There is room inside the housing for the use of a standard
“P” type plumbing connection. The waste outlet should be located in the wall behind the unit.
The SUITMATE®UTILITIES LOCATION DIAGRAM shows the appropriate location for the waste
duct. If an open-site drain connection is required and
the open site is to be positioned within the
SUITMATE®housing, locate the top of the
receiver pipe below the top of the Motor end
cap, and locate the top outer edge of the
receiver pipe at least 1-1/4 inches from the body
of the Motor. (See also the SUITMATE®
UTILITIES LOCATION DIAGRAM.) Be certain
that the cut off end of the drain extension tube is
below the top of the receiver with the angle cut
facing away from the Motor as illustrated.
3
Black
AEC1843
COM
TIMER
Black AEC1842 (From Timer To Motor)
White AEC1841 (From Timer To Motor)
Black
AEC1815
N.O.
HOT WHITE
H O T N E U
H O T N E U G R O U N D
CUSTOMER'S ELECTRICAL SERVICE
11 5V - 20A M P - 60 H Z
Black
AEC1840
2
LOAD
L1 L 2
MOTOR
White AEC1813
(F rom G FC I To M oto r)
MICROSWITCH
COMMON
OPEN
GREEN
SCREW
Green AEC2061
(Fro m G FC I To M otor)
GFCI IS
"GROUND FAULT CIRCUIT INTERRUPTER"
MOTOR CONTROLLER AND SWITCH
RESET BUTTON, ON
TEST BUTTON, OFF
GREEN
SCREW
GFCI
SUITMATE
PROPER ELECTRICAL CONNECTIONS FOR THE SUITMATE®
Note: Strictly follow all applicable local electrical codes and regulations.
Motor
End
Cap
Motor
Housing Suitmate
Tailpipe
Angle Cut
Extension
Tube
To Drain
Suitmate Housing
The SUITMATE®, equipped with a ground fault circuit interrupter (GFCI), which is designed to be
connected to a 115 volt, 20 ampere 60 Hz dedicated circuit that is protected by a fuse or circuit
breaker. A PLUG-IN INSTALLATION IS NOT ACCEPTABLE! The utilized circuit must be run
to the SUITMATE®weatherproof Junction Box that contains the GFCI. A liquid tight raceway
such as Ultralight®Liquid Tight Flexible Conduit (or the equivalent) should be used from
115VAC 60 Hertz Installation Instruction

the circuit connection to the Junction Box. The SUITMATE®UTILITIES LOCATION DIAGRAM
shows the location of the suggested area behind the unit for the entrance of the electrical
raceway that does not interfere with the drainage connection.
WARNING! Do not route the raceway where wastewater can flow or drip on it.
Remove the cover of the weatherproof Junction Box, which contains the GFCI, and remove the
GFCI mounting screws. The circuit ground conductor must be connected to the green grounding
screw located on the GFCI. If no ground is available on the circuit utilized, you must provide a
proper ground for the SUITMATE®. The hot and neutral leads of the power circuit should be
connected to the GFCI screw terminals marked “LINE”. Connect the hot lead to the terminal
marked “HOT” and the neutral lead to the terminal marked “WHITE”. After the correct electrical
connections have been properly made, remount the GFCI using the screws previously removed.
Reinstall the weatherproof Junction Box cover previously removed. This cover provides access
to the GFCI “TEST” and “RESET” buttons.
POSTING THE WALL SIGN
It is important that the wall sign included in the INSTALLATION PACKAGE be mounted on the
wall above the unit. Locate the bottom edge of the sign six inches above the SUITMATE®. At
this height the sign will not be blocked when the lid is raised. It will also serve as a stop to keep
the Lid from striking the wall behind the unit.
The sign has an adhesive foam strip around the perimeter of the backside. Be certain the surface
that the sing is to be mounted to is clean and dry. Without touching the sign to the wall, align the
sign six inches above the unit and at its center. Press the sign to the wall and rub firmly over the
adhesive portion of the sign.
TESTING AND OPERATION
After the mounting and all connections are complete, test the SUITMATE®as follows:
1. Make certain all packaging material is removed from the unit including material around the
Motor and the shipping board on the bottom of the unit.
2. Check to see that the Basket is empty and that he Lid moves freely.
3. Press down on the Lid and hold down until the unit stops (approximately 8 seconds). The
unit should run smoothly and there should be no excessive vibration or noise.
4. Release and lift the Lid from the down position. The Basket should be stopped.
5. Test the SUITMATE®by putting a wet swimsuit in the unit according to the instructions on the
underside of the Lid. If there is excessive vibration or noise it is usually caused by the
improper loading of the swimsuit. Be certain that the swimsuit is pushed to the bottom of the
Basket and that all material is at least two inches below the top of the Basket.
INSTALLATION TROUBLESHOOTING
If the SUITMATE®does not operate, check the following:
1. Check to see if there is power to the unit. Check the circuit using an A.C. voltmeter set to the
appropriate range; measure across the “LINE” side of the GFCI.
2. Make certain that the GFCI switch is in the “ON” position. The red button must be depressed
to turn on the GFCI.
3. Check the connections on the GFCI Junction Box. Be certain there is power on the “LOAD”
side of the GFCI.
4. Check the SUITMATE®TROUBLESHOOTING section in this manual for additional
troubleshooting assistance.
115VAC 60 Hertz Installation Instruction

FINISHING THE INSTALLATION
Be certain to save this SUITMATE®MANUAL along with all the other materials included in the
INSTALLATION PACKAGE envelope. If you did not receive all the materials listed or need
additional information, call the Extractor Corporation at 800-553-3353. With proper installation,
use, and maintenance your SUITMATE®Swimsuit Water Extractor will provide you with years of
trouble-free service.
ELECTRICAL
WASTE
DRAIN
SUITMATE
UTILITIES LOCATION
DIAGRAM
FLOOR
20 1/2"
19 3/4"
1"
7"
3 1/2"
3"
3/4"
14 5/8"
7 5/16"
2"
40 1/4"
38 1/4"
5/16" Ø
4 3/4"
3 1/4"
Suitmate Case
115VAC 60 Hertz Installation Instruction
Other manuals for Swimsuit Water Extractor
2
Table of contents
Other Suitmate Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

Gorenje
Gorenje S3 IHGC963S4X manual

KOBE
KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products
U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg
Kuppersberg DUDL 4 LX Technical Passport

Framtid
Framtid HW280 manual

Thermador
Thermador HGEW 36 FS installation manual