Sun Oracle StorageTek 4199516 User manual

Submit comments about this document to STP_FEEDBACK_US@ORACLE.COM.
StorageTek 4199516 Redundant
Power Ethernet Switch
Rack Installation Guide
Part No. E24344-01
July 2011

ii StorageTek 4199516 Ethernet Switch Rack Mounting Guide
StorageTek 4199516 Redundant Power Ethernet Switch Rack Installation Guide
E24344-01
Oracle welcomes your comments and suggestions for improving this book. Contact us at STP_FEEDBACK_US@ORACLE.COM.
Please include the title, part number, issue date, and revision.
Copyright © 2009, 2011, Oracle and/or its affiliates. All rights reserved.
This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are
protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy,
reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any
means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report
them to us in writing.
If this is software or related software documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S.
Government, the following notice is applicable:
U.S. GOVERNMENT RIGHTS Programs, software, databases, and related documentation and technical data delivered to U.S. Government
customers are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and
agency-specific supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the
restrictions and license terms set forth in the applicable Government contract, and, to the extent applicable by the terms of the Government
contract, the additional rights set forth in FAR 52.227-19, Commercial Computer Software License (December 2007). Oracle USA, Inc., 500
Oracle Parkway, Redwood City, CA 94065.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for
use in any inherently dangerous applications, including applications which may create a risk of personal injury. If you use this software or
hardware in dangerous applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to
ensure the safe use. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in
dangerous applications.
Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Oracle and Java are registered trademarks of Oracle and/or its
affiliates. Other names may be trademarks of their respective owners.
AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel
Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or
registered trademarks of SPARC International, Inc. UNIX is a registered trademark licensed through X/Open Company, Ltd.
This software or hardware and documentation may provide access to or information on content, products, and services from third parties.
Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content,
products, and services. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to
or use of third-party content, products, or services.

iii

iv StorageTek 4199516 Ethernet Switch Rack Mounting Guide

v
Contents
About this book vii
How this book is organized .......................................................................................................vii
Taking advantage of this book’s hypertext features ..................................................................viii
Understanding the conventions used in this book ....................................................................viii
Access to Oracle Support ..........................................................................................................viii
Commenting on this book ..........................................................................................................ix
1 Getting to know the switch 1
Understanding the front panel ..............................................................................................2
Understanding the rear panel ................................................................................................2
Understanding switch port numbering ..................................................................................3
2 Installing the switch in a rack 5

vi StorageTek 4199516 Ethernet Switch Rack Mounting Guide

About this book vii
About this book
This book is intended for anyone who has to install a StorageTek 4199516 Redundant
Power Ethernet Switch. The remainder of this preface explains how you can use this
book most effectively and how you can obtain updated or supplementary
documentation.
How this book is organized
The document is task-oriented, organized around the work you have to do rather than
around the features or components of the product. Chapters and sections generally
begin with a list of tasks covered. Tasks are presented in order, and the steps in each
process are numbered, in the sequence in which they are to be performed.
Conditional steps (steps that you perform only in specified circumstances) begin with
the condition (“If A...”) and end with the corresponding action (“... do B”); if the
condition does not apply, you simply skip the step. Each task ends with a reference to
the next task in the sequence:
Next task: “Installing ...” on page 3.
When the setup process branches, the task ends with conditional alternatives:
Next task:
• If the customer does not plan to run the management console from a host
onthe local area network (LAN), press Skip, and go to the next task.
• Otherwise, carry out the procedure “Configuring the Ethernet LAN” on
page 57.
When you have finished a task or sequence of tasks, this is clearly noted in the
document:
Stop here.
To minimize the time that you spend switching between publications or between
major sections of the document, we have made an effort to avoid cross references to
external information wherever possible. If you need to have a figure, a table, or a
procedure, it should always be, at worst, on a neighboring page.

Taking advantage of this book’s hypertext features
viii StorageTek 4199516 Ethernet Switch Rack Mounting Guide
Taking advantage of this book’s hypertext features
If you choose to view this book online, rather than in printed form, you can jump
quickly to any part of the book by clicking on the corresponding entry under the
Bookmarks tab on the left side of the Adobe Acrobat interface. In addition, clicking
on entries in the table of contents, cross references, or references to subsequent tasks
will take you directly to the indicated part of the document. You can then use the
back arrow on the Adobe Acrobat Reader to return, if desired, to the point you left. In
addition, clicking on most Uniform Resource Locators (URLs) and on most references
to online resources will open your default web browser to the corresponding web
page. You can, if necessary, obtain a required download immediately (be aware,
however, URLs to specific pages change frequently and may not always be accurate).
Understanding the conventions used in this book
The table below illustrates the conventions that represent literal and variable values,
commands, and property names in this book.
Access to Oracle Support
Oracle customers have access to electronic support through My Oracle Support. For
information, visit http://www.oracle.com/support/contact.html or visit http://
www.oracle.com/accessibility/support.html if you are hearing impaired.
Convention Meaning Examples
AaBbCc123 Fixed-width text is used for literal values,
including names of commands, files, directories,
literal computer inputs/outputs, and Uniform
Resource Locators (URLs)
Edit your.login file.
Use ls -a to list files.
% You have mail.
AaBbCc123
AaBbCc123
Oblique text is used for variables that stand for
real names or values and for book titles.
To delete a file, type:
rm filename.
ABCDEF Fixed-width uppercase text represents electrical
and system states, Boolean values, and
constants.
ON, OFF
TRUE, FALSE
ONLINE, DOWN
ABCD Bold, san-serif, uppercase text indicates callouts
in illustrations.
Click Submit (Abelow).
1. Numbered paragraphs indicate steps in a
process that should be executed in sequential
order.
• Bulleted paragraphs indicate lists of alternatives
or components.
[iasd01-no1]root# A commandline prompt
Tab, Shift, AKeys on the keyboard
Ctrl-Alt-Del, Alt-0169 A combination of keys on the keyboard, pressed
at the same time.

Commenting on this book
About this book ix
Commenting on this book
Sun welcomes your comments and suggestions for improving this book. Contact us
StorageTek 4199516 Redundant Power Ethernet Switch Rack Installation Guide, part
number E24344-01 (July 2011).

Commenting on this book
x StorageTek 4199516 Ethernet Switch Rack Mounting Guide

Getting to know the switch 1
1
Getting to know the switch
The StorageTek 4199516 Redundant Power Ethernet Switch is an Ethernet switch with
redundant, dual power supplies. This feature makes the switch ideal whenever high-
availability LAN connectivity is desired. The switch offers the following additional
features:
• thirty-two 10/100 Base-T ports
• two 10/100/1000 Base-T ports
• requires no software or processor intervention
• fits standard, 19-inch racks.
The remainder of this introduction describes the physical layout, status indicators,
power connections, and port numbering scheme of the switch. See the following
sections for details:
•“Understanding the front panel” on page 2
•“Understanding the rear panel” on page 2
•“Understanding switch port numbering” on page 3.

2 StorageTek 4199516 Ethernet Switch Rack Mounting Guide
Understanding the front panel
The front, port-side panel of the switch holds the thirty-two 10/100 Base-T ports
(Abelow) and the two 10/100/1000 Base-T ports (B). The two redundant power
supplies reside inside the case behind the cooling holes in the top panel of the
case (C).
Three light-emitting diodes (LEDs) display the current power state of the switch.
Amber warning LEDs light up to indicate faults on power supplies 0 (Dabove)
and 1 (E). A green LED lights whenever the system has power (F).
Standard port LEDs display the link status of each port. A green LED on the left side
of the port glows green when the link is operational (Gabove). An amber LED to the
right of the port blinks when the link is actively transmitting or receiving (H).
Understanding the rear panel
The rear, non-port-side of the switch holds only the power-cord receptacles for power
supplies 0 (Abelow) and 1 (B). The rest of the panel is taken up by ventilation
openings for the internal circuitry (C).
D
F
E
GH
A
BC
B
A
B
C
C
C

Getting to know the switch 3
Understanding switch port numbering
The thirty-two 10/100 Base-T ports are arranged in blocks of eight, with the odd
numbers (starting with 1) on the bottom and the evens on the top (Abelow). The
two 10/100/1000 Base-T ports are located to the right of 10/100 Base-T ports, with
port A1 on the bottom and A2 on the top (B).
2468
1357 10 12 14 16
9111315 18 20 22 24
17 19 21 23 26 28 30 32
25 27 29 31
A2
A1
B
A

4 StorageTek 4199516 Ethernet Switch Rack Mounting Guide

Installing the switch in a rack 5
2
Installing the switch in a rack
The StorageTek 4199516 Redundant Power Ethernet Switch fits any standard, 19-inch
rack. To install the switch, proceed as follows.
▼Installing the switch in a 19-inch equipment rack
1. If your rack requires cage nuts, install one nut in the upper and lower mounting
holes of the selected RU on both the left and right posts of the rack.
2. In the selected RU, position the switch horizontally and with the ventilation
opening facing up (Abelow).
Caution – for safety and regulatory compliance reasons, the switch
must be installed in the upright, horizontal position described.
3. Insert a mounting screw into each of the mounting holes in the mounting
brackets on the front of switch (Babove), and tighten each screw to securely
fasten the switch to the rack (C).
4. To use the redundant power feature, connect a power cord to each of the two
redundant power supplies (Dbelow) and then plug each power cord into an
independent source of power.
B
A
C

6 StorageTek 4199516 Ethernet Switch Rack Mounting Guide
For example, to provide full redundancy, you could plug the two
cords directly into two independent supply circuits or into two,
separate, rack-mounted power distribution units (PDUs) that are
themselves connected to independent supply circuits.
5. If you do not require fully redundant power, connect one of the
two power cords (Dabove) to one of the two power supplies
and plug the cord into a rack-mounted power distribution unit
(PDU) or room power.
Note that an unconnected power supply will light up the
corresponding amber fault LED.
The switch is installed in the rack and ready for network cabling.
D
Table of contents
Popular Network Router manuals by other brands

Siemens
Siemens FN2012-A1 Mounting & installation

D-Link
D-Link 790069450846 user manual

Alternetivo
Alternetivo FG-WDM-100Mbps-1310-WIFI quick start guide

Riverstone Networks
Riverstone Networks WICT1-12 user guide

SkyStream NETWORKS
SkyStream NETWORKS SMR-24 user guide

Raisecom
Raisecom ISCOM2812GF Hardware Installation User Manual