5
Installation
Before mounting and power up, it is necessary to verify protective earthing and cable
connectors.
1. Ensure the device has no damage due to transportation.
2. Attach the device to the DIN rail.
3. Set position of DIP-switcher 1 in accordance with needed device configuration (single-
channel or dual-channel mode).
4. All input and output channels have 120 Ohm terminators, managed by special DIP-
switches TIN, T(1)–T(5). To connect the terminator to the line is necessary to set proper
switcher in ON position, to disconnect- in OFF position.
5. Connect the power, input and output DMX lines to the corresponding device ports.
6. When device properly connected, the LED indicator on the device is lit. Its color indicates
the presence of a valid DMX input signal: Green - present, Red - missing.
7. The device is ready for use.
LED indication
DMX512 mode Bus mode
Green Valid DMX signal Bus is idle
Red No DMX signal Bus is busy
Off Device/Section doesn’t work Device/Section doesn’t work
ON OFF
SW1 RDM enabled RDM disabled
SW2 Dual splitter mode Single splitter mode
SW3 Full transparent mode Dedicated input(s) mode
SW4 Bus indication mode DMX512 indication mode