Sunrise spas Paragon Collection Series User manual

2
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
INDEX
Table of Contents
CONFIGURATION TABLE ...........................................................................................................................................................................................................................................................3
CONGRATULATIONS ON THE PURCHASE OF YOUR NEW SPA.........................................................................................................................................................3
YOUR PERSONAL SPA DATA................................................................................................................................................................................................................................................6
IMPORTANT SAFETY INSTRUCTIONS ...........................................................................................................................................................................................................................7
INSTALLATION INSTRUCTIONS.......................................................................................................................................................................................................................................10
ELECTRICAL CONNECTION GENERAL INFORMATION............................................................................................................................................................................12
EUROPEAN 50HZ MODELS.................................................................................................................................................................................................................................................13
TYPICAL RESIDUAL CURRENT DETECTOR (RCD)........................................................................................................................................................................................14
230 VOLT SUPPLY CONNECTION ................................................................................................................................................................................................................................15
CONVERSION FROM SINLGE SERVICE TO 3-SERVICE............................................................................................................................................................................16
WHAT’S INSIDE YOUR SPA..................................................................................................................................................................................................................................................17
WHAT’S UNDER YOUR SPA (THE EQUIPMENT)..............................................................................................................................................................................................20
START-UP..............................................................................................................................................................................................................................................................................................21
SPATOUCH ICON DRIVEN USER GUIDE.................................................................................................................................................................................................................24
MP3/BLUETOOTH READY SYSTEM OPERATION..........................................................................................................................................................................................56
ACCESSING FILTER CARTRIDGES ...............................................................................................................................................................................................................................57
MAINTENANCE................................................................................................................................................................................................................................................................................58
DIVERTER VALVE MAINTENANCE................................................................................................................................................................................................................................60
FILTER SYSTEM ..............................................................................................................................................................................................................................................................................
61
DRAINING YOUR SPA................................................................................................................................................................................................................................................................62
WINTERIZING YOUR SPA.......................................................................................................................................................................................................................................................64
TROUBLESHOOTING YOUR SPA ...................................................................................................................................................................................................................................65
WATER TREATMENT GUIDE ...............................................................................................................................................................................................................................................71
8

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
3
BRAND CONFIGURATION TABLE
CONGRATULATIONS
ON THE PURCHASE OF YOUR NEW SPA
We have tried to compile a complete, easy to understand manual all about your spa and its' maintenance. Years of
research and development have gone into producing the superior quality product you have purchased. Your spa is
made from the highest quality material and latest technology available today. Pride and meticulous attention to detail
have resulted in the spa you have chosen. With proper care, your spa will provide many years of comfort and pleasure.
Please take a few minutes now to read all of the instructions before you install your spa. This owner's manual will help
you understand your spa, so you will get the most from your investment. For service and advice, do not hesitate to call
your authorized dealer. Your questions will be welcomed by friendly and knowledgeable staff.
May you have as much pleasure and enjoyment using your new spa, as we had making it for you.
We understand there are many choices in the marketplace when you are
considering adding a spa to your home, so thank you for choosing a spa by Leisure
Manufacturing Inc. Enjoy!
Line
Model
Frame/Bottom
Filter
Keypad User Guide
Paragon
Jewel 150E
(Shallow)
Rot Not Moulded Base Paragon Whitewater SpaTouch Icon
Jewel 250E Rot Not Moulded Base Paragon Whitewater SpaTouch Icon
Legend 250E Rot Not Moulded Base Paragon Whitewater SpaTouch Icon
Essence 250E Rot Not Moulded Base Paragon Whitewater SpaTouch Icon
Genesis 250E Rot Not Moulded Base Paragon Whitewater SpaTouch Icon
Medallion 350E Rot Not Moulded Base Paragon Whitewater SpaTouch Icon

4
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
SAFETY SIGN
IMPORTANT NOTICE: SAFETY SIGN
Enclosed with this Owner’s Manual is a Safety Sign. This sign must be permanently installed in a location that is visible
to all spa users. It is the spa owner’s responsibility to remind all users about safe spa use, particularly occasional users
of the spa, who may not be aware of the various health and safety issues.
To obtain additional or replacement copies of the safety sign, contact your dealer.
ATTENTION: SPA OWNER
In the immediate vicinity of the spa, a sign must be posted stating the following:
1) The spa’s address
2) Location of the nearest telephone with posted emergency numbers
3) Nearest available police department, fire department and ambulance/rescue unit

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
5
CONDITIONS OF WARRANTY
AND CONSUMER OBLIGATIONS
As a new spa owner, you have specific obligations in regards to the installation and safe use of this spa. Failure to do
so may result in a loss of warranty coverage not to mention personal injury to those using this spa.
Inspect the spa upon its arrival for damage. If you are being made aware of this for the first time, your
spa may not have been delivered in its original factory packaging. If this is the case, please take time to
inspect your spa and report any damage or missing items to your dealer.
1) Install the spa both physically and electrically, in accordance with any local codes.
2) Provide suitable access to all sides of the spa. Any custom built enclosure, either above or below a deck
surface, must be able to be removed with relative ease.
3) Provide sufficient work area around the spa’s perimeter especially the side the spa’s equipment is located on.
4) Regularly check operation of the spa in regard to filtration, jet pump operation and the heating system.
5) Report any concern to the dealer. Any problem that arises towards the end of particular warranty coverage
should be documented and reported to the dealer
6) Maintain the water’s chemical balance and clean/replace the system’s cartridge filter(s) as instructed by the
dealer and/or Leisure Manufacturing Inc.
7) Drain and refill the spa on a regular basis as instructed by the dealer and/or Leisure Manufacturing Inc.
8) Winterize and store the spa and its’ components in accordance with the manufacturer’s printed instructions.
9) Care for and maintain the spa cabinet, hard cover and acrylic surface as outlined in these instructions.
10)Ask your dealer to record the spa’s serial number on your bill of sale.
11)Provide a copy of your bill of sale, if requested by the dealer or Leisure Manufacturing Inc.

6
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
YOUR PERSONAL SPA DATA
Before you begin the installation of your new spa please take a few minutes to fill out the details of your spa. This
information will become invaluable later should you have a question for your dealer or should you need to make a
warranty claim. Ask your dealer to assist you in recording this information.
Model Year
Model Name/Number
Spa Serial#
Jet Pump(s) Size (HP, SPL, Watts etc.)
Heater size (kw)
Filter Cartridge (Model Number/Size)
Topside Control/Keypad
Spa Pack Model #
Spa Pack Serial #
Dealer Name
Date of Purchase
We strongly recommend that you attach your bill of sale to this manual after installation is complete. Keep it in a
safe place for future reference. You may also wish to attach any notes you have made about the dealer delivery,
dealer start up demo or any other notes that may be of benefit in the future.

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
7
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS
DANGER:
Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by
children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.
DANGER:
Risk of Injury. The suction fittings in this spa are sized to match the specific water flow created by the
pump. Should the need arise to replace the suction fittings or the pump, be sure that the flow rates are compatible.
Never operate spa if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than
the flow rate marked on the original suction fitting.
DANGER:
Risk of Electric Shock. Install at least 5 feet (1.5m) from all metal surfaces. As an alternative, a spa may be
installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 8 AWG
(8.4mm2) solid copper conductor to the wire connector on the terminal box that is provided for this purpose.
DANGER:
Risk of Electric Shock. Do not permit any electrical appliance, such as a light, telephone, radio, or television,
within 5 feet (1.5m) of a spa.
WARNING:
To reduce the risk of injury:
a) The water in a spa should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C
are considered safe for a healthy adult. Lower water temperatures are recommended for young children and
when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 38°C (100°F).
c) Before entering a spa, the user should measure the water temperature since the tolerance of water
temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the
possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa since some medication may induce
drowsiness while other medication may affect heart rate, blood pressure, and circulation.
CAUTION:
Maintain water chemistry in accordance with the manufacturer's instructions.

8
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
READ AND FOLLOW ALL INSTRUCTIONS
When using this equipment, basic safety precautions should always be followed. Including the following:
a) A green coloured terminal or a terminal marked G, GR, Ground, Grounding or the international grounding
symbol is located inside the supply terminal box or compartment. To reduce the risk of electric shock, this
terminal must be connected to the grounding means provided in the electric supply service panel with a
continuous copper wire equivalent in size to the circuit conductors supplying this equipment.
b) At least two lugs marked "BONDING LUGS" are provided on the external surface or on the inside of the
supply terminal box or compartment. To reduce the risk of electric shock, connect the local common bonding
grid in area of the hot tub or spa to these terminals with an insulated or bare copper conductor not smaller
than No.6 AWG.
c) All field-installed metal components such as rails, ladders, drains or other similar hardware within 3m (10ft) of
the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than
No.6 AWG.
DO NOT connect your spa to an extension cord.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Hyperthermia
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of
the body reaches a level several degrees above the normal body temperature of 37°C (98°F). The symptoms of
hyperthermia include drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of
hyperthermia include:
•Unawareness of impending hazard
•Failure to perceive heat
•Failure to recognize the need to exit spa
•Physical inability to exit spa
•Fetal damage in pregnant women
•Unconsciousness and danger of drowning
WARNING:
The use of alcohol, drugs or medication can significantly
increase the risk of fetal hyperthermia.

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
9
IMPORTANT SAFETY INSTRUCTIONS FOR
SPAS WITH AUDIO SYSTEMS
CAUTION:
Risk of Electric Shock. Do not leave compartment door open.
CAUTION:
Risk of Electric Shock. Replace components only with identical components.
Do not operate the audio/video controls while inside the spa.
WARNING:
Prevent Electrocution. Do not connect any auxiliary components to the system (example: cable, additional
speakers, headphones, additional audio/video components etc).
These units are not provided with an outdoor antenna. When provided, it should be installed in accordance with article
810 of the National Electrical Code, ANSI/NFPA 70.
Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk
of injury. Refer all servicing to qualified service personnel.
If the power supply connections or power supply cord(s) are damaged; if water is entering the audio/video
compartment or any electrical equipment compartment area; if the protective shields or barriers are showing signs of
deterioration; or if there are signs of other potential damage to the unit, turn off the unit and refer servicing to a
qualified service personnel.
This unit should be subjected to periodic routine maintenance (example: once every 3 months) to make sure that the
unit is operating properly.

10
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
INSTALLATION INSTRUCTIONS
Remember, your new spa is a powerful piece of electrical and plumbing equipment. You owe it to yourself, your family
and your friends to install it correctly and safely. Before attempting to hook-up or use your spa, please read the
following instructions.
ATTENTION:
This spa is intended for outdoor use, however it can be installed indoors
when precautions are taken to ensure the spa is installed and located
in such a manner that any water that could leak, splash or be released as humidity
will drain away harmlessly.
POSITIONING OF YOUR SPA -CONSIDERATIONS
Your spa is completely self-contained. Therefore, you can situate it just about anywhere; on a patio, in or on a deck, in
a basement or sunroom. It comes completely pre-plumbed and water tested from the factory. Never lift or carry the spa
by the plumbing. Damage could occur which would not be covered under warranty.
You should take into account the following when selecting prospective spa sites in order to maximize enjoyment.
To avoid any personal injury or damage to your spa, have 4-5 people ready to assist you to move the spa to its' final
location. Use a moving dolly and/or straps to more evenly distribute the spa's weight. Never lift or carry the spa by its'
plumbing.
SITE CONSIDERATIONS
Local codes Local building, property and electrical codes may affect your installation.
Delivery access to location Gates, overhangs, fences, gas meters, and AC units may become obstructions.
You may need to access from a neighbour's yard or employ a crane.
Vegetation in spa area Trees, bushes, flowers etc. can all add to spa maintenance.
Spa location relative to buildings The location could add to your spa maintenance (removing snow from cover) and
increase operating costs.
Fences, tree lines More privacy during use and serves as a wind break but may also add more
maintenance.
Spa step out location Any surface that is slippery when wet could be dangerous for bathers both
entering and exiting the spa.
Spa Direction View when using a lounger & ease of access for servicing.
Downspouts and natural
drainage of land These may flood the spa area, damage spa or create a safety hazard to bathers.
Outside water supply and
draining location You will need a place to safely drain the spa and a way to refill it easily.
Optional accessories These may take up added space that you must plan for (cover remover/holder).

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
11
SPA SUPPORT
Whatever the support is, it must be:
a) A continuous, level surface, above grade, capable of handling 80 lbs. per sq. ft. that will not be compromised by
changes in the water table or water sitting in the area.
b) Such that the weight of the spa, water and bathers is not supported by the spa lip.
c) In full contact with the bottom of the spa
ACCEPTABLE SPA SUPPORT BASES
Concrete Pad 4" to 6" thick with provision for run off
Patio Stones, Pavers etc. Levelled with proper preparation of the earth
Wooden Deck Floor Incl. centre support uprights in concrete and joists spaced 12" on centre
Engineered Plastic Spa Pad Following pad manufacturer's instructions
Unacceptable Spa support bases include crushed gravel, stone dust, bare earth, platform built directly onto earth.
Damage caused by improper spa installation will void factory warranty.
Do NOT locate your spa in a low run-off area since melting snow or rain can cause pump and equipment damage.
WATER SHOULD ALWAYS DRAIN AWAY FROM THE SPA.
See next page for dimensions that can be used to determine the proper location of submerged conduits in concrete
slab installations. All dimensions are made from the outside of the spa's frame with the access panels removed.

12
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
ELECTRICAL CONNECTION
GENERAL INFORMATION
A. LOCATING A CONDUIT WITHIN A CONCRETE PAD
If your intent is to bring a conduit and power wires up under the spa we suggest that it
enter the spa cavity in the front, left corner; 6” (15cm) Dimension A in from the left
and 6” (15cm) Dimension B up from the front. See A & B on the diagram below. This
location will allow you to stay clear of spa pumps and other equipment while giving you
a short and easy access to the left side of the spa pack, where the electrical entry hole
and terminal block are located.
B. SUPPLY CABLE ENTRY INTO SPA EQUIPMENT AREA
•You may enter the spa cavity at any other point around spa provided you have reviewed the location and
determined there is no interference. You may also decide to enter at an adjoining wall (depending on the
positioning of the spa) and route a conduit along the spa kicker. Ask your electrician for his/her advice in
these matters.
•In all cases the best side for entry of the supply cable is the side to your left when you are standing at the
equipment panel.
•Right side entry is possible; however, this may involve additional supply cable, parts and time.
HOW TO PASS THE CABLE THROUGH THE SPA ENCLOSURE
Polysteel Frame with Polyethylene Bottom and Polysteel Panels
a) You can choose to notch the polysteel panel so you can pass the cable/conduit through and still be able to
remove/replace the panel for servicing. You should consider securing the cable or conduit to the spa’s metal
frame where cable/conduit passes through the cabinet.
b) You may also route a cable up under the corner. The curved panel is flexible enough and there is enough
space to run the cable this way. Removing the corner may help you to do this easier.
c) On a concrete pad where you have a conduit or cable coming up within the perimeter of the spa, you can
easily cut an opening in the polyethylene bottom to access the cable or conduit/wires. See above table for
recommended opening location.
You may wish to insulate any opening or cut-out you make in the spa’s cabinet panel or corner or bottom to keep cold
air and small animals out.

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
13
EUROPEAN (50HZ) MODELS
Please note the following important information:
When using this electrical equipment, basic safety instructions should be followed, including the following:
Read and Follow ALL Directions
(1) This spa must be connected to an RCD (Residual Current Detector) with a residual operating current not
exceeding 30mAmps.
(2) Electrical installation must be carried out by a qualified electrician strictly in accordance with local governing
codes.
(3) A terminal marked "ground" is located within the control box. To reduce the risk of electric shock this terminal
must be connected to the grounding means provided in the electric supply service panel with a continuous
copper wire equivalent in size to the circuit conductors supplying the equipment.
(4) At least two lugs marked "bonding lugs" are provided on the external surface of the control box. To reduce the
risk of electric shock connect the local common bonding grid in the area of the hot tub or spa to these
terminals with an insulated or bare copper conductor not smaller than No. 6 AWG.
(5) Test the RCD before each use of the spa, according to the manufacturer's instructions.
(6) Before servicing any electrical components of the system make sure that the power supply is switched off.
(7) Keep the door closed in order to provide IPX5 protection to the electrical compartment.
Any opening made through the spa enclosure for the entry of input cables/wires,
must be made watertight to preserve the IPX5 rating of the appliance.
ATTENTION: ELECTRICIAN & SPA OWNER
PICO FUSE
Balboa Spa packs contain a special fuse, referred to a “Pico fuse”.
This special fuse is designed to open (burn out) if:
a) There is any problem with how the electrical supply is connected
b) There is a power surge to the spa pack
This fuse is not replaceable and the entire spa pack is considered destroyed.
WARNING!
THIS IS NOT A CONDITION THAT IS COVERED UNDER THE
SPA PACK MANUFACTURER’S WARRANTY OR
LEISURE MANUFACTURING’S COMPREHENSIVE SPA WARRANTY.

14
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
TYPICAL RESIDUAL CURRENT DETECTOR (RCD)
A residual current device (RCD,) is the generic term for a device that monitors the current in the line conductor and
the neutral conductor of a circuit in an earthed system.
In a circuit that’s operating properly, the vector sum of the live and neutral current values added together will be zero.
Current flowing to earth, due to a line earth fault, will return via the earth conductor, and regardless of load conditions,
will be registered as a fault. This current flow will give rise to a residual current that will be detected by the device. If
the residual current exceeds the rated sensitivity of the RCD, it will automatically activate a tripping of the faulty circuit.
<- Two Pole RCD
Typical specifications are as follows:
Residual Current Devices ( RCD’s ) range
Sensitivity - from 10 to 500mA
Voltage - 2 poles : 230V; 3/4 poles: 230/400V
Connection capacity
- 25A: 6/10 mm² (flexible/ rigid cable)
- 40,60A: 16/25 mm²
- 80,100A: 35/50 mm²
<- Four Pole RCD

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
15
230 VOLT SUPPLY CONNECTION
A) SRBP21, SRBP21X AND SRBP21MS SPA PACK
Power Requirements:
Single Service
[3 wires (line, neutral, ground)]
230VAC, 50Hz, 1p, 32A (Circuit Breaker rating =40A max.)
Dual Service
N/A
230VAC, 50/60Hz, 1p, 32A (Circuit Breaker rating =40A max.)
3-Service
[5 wires (line 1, line 2, line 3, neutral, ground)]
400VAC, 50Hz, 3p, 16A (Circuit Breaker rating =20A max each phase line.
IMPORTANT –
Service must include a neutral wire, with a line to neutral voltage of 230VAC.
SRBP21, SRBP21X & SRBP21MS
Spa Pack –Single Service

16
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
CONVERSION FROM SINGLE SERVICE TO
3-SERVICE
1. Remove the jumper wire from J51 (Area 1) to J88 (Area 2)
2. Remove the jumper wire from J52 (Area 1) to J62 (Area 2)
3. Move the jumper wire attached to J60 from J36 in Area 3 to J45 in Area 4. (J60 to J45)
4. Move the jumper wire attached to J41 from J12 in Area 3 to J79 in Area 4. (J41 to J79)
5. Set DIP Switches A2 and A5 to OFF.
6. Terminal block must be wired according to the 3-Phase illustration on the wiring diagram
1. Line 1 –Brown
2. Neutral - Blue
3. Line 2 –Brown
4. Line 3 -Brown
SRBP21, SRBP21X & SRBP21MS
Spa Pack - 3-Service
Power Up Screen
Each time the system powers up, a series of numbers is displayed. After the start-up sequence of numbers, the system
will enter Priming Mode. Next, refer to the User Guide for your keypad at the back of this manual.
Wire Size and Over Current Protection
Total Ampere Rating of
Power System
Minimum Wire Size
Use Copper ONLY
With 90°C Insulation
Ampere Rating of
RCD Circuit-breaker
OA to 16A #12 AWG 20
16A to 20A #10 AWG 25
20A to 24A #10 AWG 30
24A to 28A #8 AWG 35
28A to 32A #8 AWG 40

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
17
WHAT’S INSIDE YOUR SPA
HYDROTHERAPY JETS
A variety of jet sizes and internal styles are used in unique seating patterns to achieve superior hydrotherapy in
individual spa models. Therefore, not every jet described or pictured below is in every model. Not all jet internal styles
are available in all jet sizes.
To adjust the water volume, simply turn the jet face clockwise to the off position or counter clockwise to the maximum
position. If you move too hard to maximum you will release the internal from the jet body.
Jet Type
Size
Adjustable Flow
Where it is most often used
Ozone/Cluster 1 ½” (38mm) No Seat backs, neck & shoulders, palm jets
Cluster 2 ¼” (56mm) Yes Palm jets, loungers, seat backs, calves, neck collars
Mini 3 5/16” (84mm) Yes Seat backs, footwells, loungers
Poly
3 ⅝” (92mm)
4 ⅜” (105mm)
Yes Seat backs, footwells, loungers
Power 5 ¼” (133mm) Yes Seat backs, footwells, loungers
Nozzle Type
Hydrotherapy Effect
Description
Fixed Stream
A steady, non-adjustable stream of water.
Neck Jets
100% shut off by using the stepped down/up movement
of the face to move volume nozzle in/out
Directional
A steady volume adjustable stream of water with
adjustable nozzle direction
Rifled
A volume adjustable stream of water that gives the feel
of a rotating stream of water without moving parts.

18
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
OTHER INTERNAL FITTINGS
Suctions
These multi-holed, anti-vortex fittings in the footwell provide the intake water for the pump(s). A
powerful suction is produced here when the jet pumps are turned on. On systems with a
circulation pump, the bypass suction fitting (smaller than regular suction), may have little to no
suction on it, since the circulation pump has a lower flow than the jet pump and the suction is
only active as the filter(s) become clogged.
All suctions in our spas are VBG compliant for your safety.
Perimeter LED Lighting
These round or hex shaped, multi-faceted fittings, located on the vertical spa wall and deck of
the spa, are the lenses for the LED light outputs.
Ozone/AquaNova Returns
These special thru wall fittings return water to your spa that has passed through the ozone or
AquaNova system. If you do not have either ozone or AquaNova on your spa, these fittings will
not be present.
Skimmer/Filter
This is the housing for your cartridge filter(s) and provides skimming action to remove surface
debris. Some models have a removable basket from which debris can be dumped.
Whitewater
(Paragon)
Nozzle Type
Hydrotherapy Effect
Description
Twin Roto
A volume adjustable jet with a fixed split nozzle that uses
the water flow to deliver dual streams of water in a
rotating pattern.
Massage
A volume adjustable stream of water that rotates. The
combination of the moving inner mechanism and front
face gives an ever changing pattern to the massage.

European Sunrise Spas 2018 Paragon Collection Owner’s Manual
DOC: OM-PARAGON-18E
19
DECK CONTROLS
Wave
Air Controls
Located on the deck of the spa, these valves control the amount of air being mixed with
the water stream at each jet. The minimum to maximum movement is approximately ¼
turn or on/off for toggle type. More air will increase the massage effect from the jet.
Proper air draw is achieved when the jet pump is operating on high speed, particularly if
the pump is a 2-speed pump.
Wave
On/off Water Valve
This positive seal valve is used to turn the water feature on/off. Adjust it as needed to
achieve the best effect from the water feature.
WATER FEATURES
LED Waterfall
The LED waterfall located on a flat along the inside of the spa creates a relaxing sheet of
water when turned on and adjusted using the on/off valve. When the Light key is pressed
LEDs light up the waterfall body as well as the water sheet coming out of the waterfall.
MISCELLANEOUS
LED Spa Light
This clear or slightly bluish fitting is usually in the vertical surface of the spa steps. It is
controlled by a designated switch on the keypad. It serves as a safety feature; lighting the
spa's contours for those entering or exiting the spa.
Head Cushions
The head cushions you will find in our spas are designed to add comfort to your spa experience. Whether it is just to
rest you head as you sit back and enjoy the hydrotherapy or if it is to support your neck as you let our neck collar jets
soothe your aching neck and shoulders, you'll find all our head cushions functional and comfortable.

20
DOC: OM-PARAGON-18E
European Sunrise Spas 2018 Paragon Collection Owner’s Manual
WHAT’S UNDER YOUR SPA
(THE EQUIPMENT)
The spa's control pack, circulation pump, heater, drain connection and ozonator may be
accessed by removing the cabinet panel along the control side of the spa. Removing the
panel(s) to the right or left of the spa's main access panel will allow access to the jet
pumps, blower and any other optional equipment. On some models, all equipment is
accessible from the main access panel.
The
free standing spa pack
houses the receptacles and switching apparatus (circuit
board) for the pump(s) blower, light, keypad etc., as well as the heat regulating system. The spa pack is also where the
electrical supply connections are made. The
horizontal heater
is attached to the bottom of the spa pack.
2-Speed Jet Pump
A high performance 2-speed jet pump provides the power to operate the various
hydrotherapy jets in the spa, at the optimum level. On models without a circulation pump, the
low speed of the pump is used to circulate the water so it can be filtered and heated. Some
models may have a 2nd jet pumps to properly power the jets. Gate valves in the plumbing
lines allow easy servicing of the circ pump and heater. Safety clips on the valve shafts keep
the valves open during use.
Ozonator
An ozonator is used to assist in water treatment. The corona discharge (CD) model produces
ozone which is drawn into the spa water via the return plumbing.
03/UV Sanitizer (AquaNova)
This unit creates both ozone and UV in perfect synergy to sanitize the spa water. Ozone
introduced into the unit’s chamber reacts with the UV light to create hydrogen free radicals
for advanced oxidization potential (AOP). This results in only oxygen bubbles emerging from
the dual return fittings.
Other items under your spa may include an audio power supply, audio receiver and LED control system.
This manual suits for next models
6
Table of contents
Other Sunrise spas Hot Tub manuals
Popular Hot Tub manuals by other brands

Kohler
Kohler ENGLEFIELD T1180-CP Operation and maintenance

Jacuzzi
Jacuzzi Elara 7242 Specifications

American Standard
American Standard Cadet 2776 W Series installation instructions

Aquatic
Aquatic AIPL6042SY Specification sheet

HoMedics
HoMedics JET SPA ELITE FB-200 instruction manual

Jacuzzi
Jacuzzi HE97000 Installation and operation instructions