Supero 6047R-E1R24L User manual

®
SUPER STORAGE SYSTEM
6047R-E1R24L
SUPER
USER’S MANUAL
1.0

The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and docu-
mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILLSUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATASTORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn-
ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other repro-
ductive harm.
Manual Revision 1.0
Release Date: September 26, 2012
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2012 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America

iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the 6047R-E1R24L. Installation
and maintainance should be performed by experienced technicians only.
The 6047R-E1R24L is a high-end storage system based on the SC846E16-
R920B 4U rackmountable chassis and the X9DRD-7LN4F-JBOD dual processor
serverboard.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with the
system and describes the main features of the X9DRD-7LN4F-JBOD serverboard
and the SC846E16-R920B chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the 6047R-E1R24L into a rack
and check out the server configuration prior to powering up the system. If your server
was ordered without processor and memory components, this chapter will refer you
to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
6047R-E1R24L.

SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
iv
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRD-7LN4F-JBOD serverboard,
including the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconfiguring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC846E16-R920B chassis. You
should follow the procedures given in this chapter when installing, removing or
reconfiguring SATA or peripheral drives and when replacing system power supply
units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specifications

Notes
Preface
v

vi
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features..................................................................................... 1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
SAS.................................................................................................................1-2
Serial ATA........................................................................................................1-2
PCI Expansion Slots....................................................................................... 1-2
1-3 Server Chassis Features ................................................................................1-3
System Power.................................................................................................1-3
Hard Drives.....................................................................................................1-3
Front Control Panel......................................................................................... 1-3
Cooling System...............................................................................................1-3
1-4 Contacting Supermicro....................................................................................1-6
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System.................................................................................... 2-1
2-3 Preparing for Setup......................................................................................... 2-1
Choosing a Setup Location............................................................................. 2-1
Rack Precautions............................................................................................2-2
Server Precautions..........................................................................................2-2
Rack Mounting Considerations.......................................................................2-3
Ambient Operating Temperature................................................................2-3
Reduced Airflow .........................................................................................2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-4 Rack Mounting Instructions............................................................................. 2-4
Rack Rails Assembly ...................................................................................... 2-4
Identifying the Inner Rack Rails......................................................................2-4
Installing the Inner Rails on the Chassis........................................................2-5
Installing the Outer Rails onto a Rack............................................................ 2-6
Installing the Chassis into a Rack...................................................................2-8
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons..................................................................................... 3-1
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual

vii
Reset............................................................................................................... 3-1
Power..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-1
Power Fail.......................................................................................................3-2
Overheat/Fan Fail ........................................................................................... 3-2
NIC1................................................................................................................3-2
NIC2................................................................................................................3-2
HDD................................................................................................................. 3-3
Power..............................................................................................................3-3
3-4 Drive Carrier LEDs.......................................................................................... 3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions..........................................................................4-1
4-2 General Safety Precautions............................................................................ 4-2
4-3 ESD Precautions............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-2
5-2 Connecting Cables.......................................................................................... 5-2
Connecting Data Cables................................................................................. 5-2
Connecting Power Cables .............................................................................. 5-2
Connecting the Control Panel.........................................................................5-2
5-3 Rear I/O Ports.................................................................................................5-3
5-4 Installing the Processor and Heatsink ............................................................5-4
Installing an LGA2011 Processor....................................................................5-4
Installing a Passive CPU Heatsink .................................................................5-7
Removing the Heatsink...................................................................................5-8
5-5 Installing Memory............................................................................................5-9
Memory Support..............................................................................................5-9
DIMM Installation ............................................................................................ 5-9
5-6 Adding PCI Add-On Cards............................................................................5-14
5-7 Serverboard Details ...................................................................................... 5-15
X9DRD-7LN4F-JBOD Quick Reference ....................................................... 5-16
5-8 Connector Definitions ...................................................................................5-18
5-9 Jumper Settings............................................................................................ 5-25
5-10 Onboard Indicators........................................................................................5-27
5-11 SATA Ports....................................................................................................5-28
Table of Contents

viii
5-12 Installing Software......................................................................................... 5-29
SuperDoctor III..............................................................................................5-30
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel .................................................................................................. 6-2
6-3 Removing the Chassis Cover .........................................................................6-3
6-4 System Fans................................................................................................... 6-4
System Fan Failure.........................................................................................6-4
Replacing System Fans.................................................................................. 6-4
Rear Exhaust Fans......................................................................................... 6-4
6-5 Drive Bay Installation/Removal....................................................................... 6-5
Accessing the Drive Bays............................................................................... 6-5
SATA Drive Installation....................................................................................6-6
Hard Drive Backplane................................................................................ 6-7
Changing the CD-ROM or DVD-ROM and HDD Trays .............................6-8
Removing the Air Shroud...............................................................................6-11
6-6 Power Supply................................................................................................6-12
Power Supply Failure....................................................................................6-12
6-7 Attaching a JBOD Expansion Chassis.......................................................... 6-13
Chapter 7 BIOS
7-1 Introduction...................................................................................................... 7-1
Starting BIOS Setup Utility..............................................................................7-1
How To Change the Configuration Data......................................................... 7-2
Starting the Setup Utility................................................................................. 7-2
7-2 Main Setup......................................................................................................7-2
7-3 Advanced Setup Configurations......................................................................7-4
7-4 Event Logs.................................................................................................... 7-25
7-5 IPMI............................................................................................................... 7-27
7-6 Boot............................................................................................................... 7-29
7-7 Security.........................................................................................................7-30
7-8 Save & Exit................................................................................................... 7-31
Appendix A BIOS Error Beep Codes
Appendix B System Specifications
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual

Chapter 1
Introduction
1-1 Overview
The 6047R-E1R24L is a high-end storage system comprised of two main subsys-
tems: the SC846E16-R920B 4U/rack mount chassis and the X9DRD-7LN4F-JBOD
dual processor serverboard. Please refer to our web site for information on operating
systems that have been certified for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the 6047R-E1R24L, as listed below:
• Two passive CPU heatsinks (SNK-P0048PS)
• Three 8-cm system fans (FAN-0127L4)
• Two rear exhaust fans (FAN-0125L4)
• One air shroud (MCP-310-49003-0N)
• SATA Accessories
One SATA backplane (BPN-SAS2-846EL1)
Twenty-four drive carriers (MCP-220-00075-OB)
JBOD Expansion Port (CBL-0352L)
• One rackmount kit (MCP-290-00057-0N)
• One CD containing drivers and utilities
Note: a complete list of safety warnings is provided on the Supermicro web site at
http://www.supermicro.com/about/policies/safety_information.cfm
Chapter 1: Introduction
1-1

1-2
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
1-2 Serverboard Features
The 6047R-E1R24L is built around the X9DRD-7LN4F-JBOD, a dual processor
serverboard based on the Intel C602J chipset. Below are the main features of the
X9DRD-7LN4F-JBOD. (See Figure 1-1 for a block diagram of the chipset).
Processors
The X9DRD-7LN4F-JBOD supports single or dual Intel® Xeon E5-2600 Series
processors. Please refer to the serverboard description pages on our web site for
a complete listing of supported processors (www.supermicro.com).
Memory
The X9DRD-7LN4F-JBOD has 16 DIMM slots that can support 512 GB of ECC
DDR3 Registered memory (RDIMM) or up to 128 GB of ECC/non-ECC DDR3
Unbuffered memory (UDIMM). See Chapter 5 for details.
SAS
A SAS 2.0 controller is integrated into the serverboard providing 8x lanes of 6Gb/s
SAS with basic HBA/ITMode controller functionality. The controller supports the
attachment of 122 SAS or SATA devices.
Serial ATA
A SATA controller is also integrated into the chipset to provide two SATA 3 (6/Gbps)
and four SATA 2 (3 Gbps) ports, which are RAID 0, 1, 5 and 10 supported. The
SATA drives are hot-swappable units.
PCI Expansion Slots
The X9DRD-7LN4F-JBOD has six PCI-E 3.0 x8 slots. The default configuration
includes a port plate with dual JBOD expansion ports occupying slot #1 (PCI-E 3.0
x8). Note that expansion slots are controlled by the CPUs, so two CPUs need to
be installed to enable all PCI expansion slots. See Chapter 5 for details.

1-3
Chapter 1: Introduction
1-3 Server Chassis Features
The following is a general outline of the main features of the SC846E16-R920B
server chassis.
System Power
The SC846E16-R920B features a redundant (two separate power modules) 920W
high-efficiency power supply with I2C. This power redundancy feature allows you to
replace a failed power supply without shutting down the system.
Hard Drives
The SC846E16-R920B chassis was designed to support 24 dual-channel SATA
hard drives, which are hot-swappable units. 2x 2.5" rear mounted hot-swap drive
bays are available as an option for use with the onboard SATA controller (MCP-
220-84606-0N)
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the SATA drives.
Front Control Panel
The control panel on the SuperServer 6047R-E1R24L provides you with system
monitoring and control. LEDs indicate system power, HDD activity, network activ-
ity, system overheat/fan fail and power supply failure. A main power button and a
system reset button are also included. In addition, two USB ports and a COM port
have been incorporated into the front of the chassis for convenient access.
Cooling System
The SC846E16-R920B chassis includes three 8-cm hot-plug system cooling fans
located in the middle section of the chassis. An air shroud channels the airflow from
the system fans to efficiently cool the processors and memory. Two additional 8-cm
fans are located at the back of the chassis to expel hot air from the system. Each
power supply module also includes a cooling fan.

1-4
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
Figure 1-1. Intel C602J Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
J23 SLOT#3
PCIE 3.0 x8
J24 SLOT#4
PCIE 3.0 x8
J25 SLOT#5
PCIE 3.0 x8
P0 P1
PE2
(AB) PE2
(CD)
PE1
(AB) DMI
DDR3 DIMM
CPU REAR
PROCESSOR
SANDYBRIDGE
PROCESSOR
SANDYBRIDGE
F
ESocket 01
#2
#1
DDR3 DIMM
#2
#1
PE3
J22 SLOT#2
PCIE 3.0 x8 PCIE 3.0 x8
PCIE 3.0 x8
PCIE 3.0 x4
SAS LSI
LAN1 LAN2
RJ45 RJ45
LAN3 LAN4
VGA CONN
IPMI LAN
PHY
RTL8201F
RJ45 RJ45
SAS2308
Powerville
I350-AM4
Quad GLAN
J26 SLOT#6
L-SAS0~3
L-SAS4~7
J21 SLOT#1
PCIE 3.0 x8
DDR3 DIMM
H
G
#2#1
DDR3 DIMM
#2#1
P1 P0
PE2
(AB) PE2
(CD) (AB) (CD)
PE1
(AB) PE3 DMI
PCH C602J
BIOS
SATA
SPI SATA Gen3
6Gbps
SATA Gen3
6Gbps
SATA
SATA [0..1]
SCU0
USB
LPCPCI 32
SPI FLASH
DDR3 DIMM
CPU FRONT
D
CSocket 00
#2
#1
#2
#1
PE3
DDR3 DIMM
B
A
#2#1
DDR3 DIMM
QPI
QPI
#2#1
I-SATA0
I-SATA1 S-SATA0
S-SATA1
S-SATA2
S-SATA3
REAR
HDR 2X5
0,1
TYPE-A
REAR
2,3
4,5 6 8,9
HDR 2X5
TPM HDR
Port 80
HERMON
WPCM450]
NCT7904D
HW Monitor
DDR3
DDR3 DIMM

1-5
Chapter 1: Introduction
Figure 1-2. X9DRD-7LN4F-JBOD Serverboard
Note: The SSG-6047R-E1R24L comes pre-installed with a JBOD expansion port
installed in PCI-E slot 1. Serverboard SAS components shown in the figure above
are not included on the X9DRD-7LN4F-JBOD
JPME1
JI2C1
VGA1
I-SATA1
I-SATA0
I-SATA5
I-SATA4
I-SATA3
I-SATA2
JIPMB1
JPME2
JPL1
JBR1
JWD1
JPG1
JPB1
JVRM_I2C1
JVRM_I2C2
JVR1
FAN5
FAN6
FAN8 FAN7
FAN1
FAN2
FAN3
FAN4
JF2
T-SGPIO1
T-SGPIO2
JUSB6
JSD1
JBT1
JBAT1
JTPM1
JF1
JPI2C1
JOH1
JI2C2
JL1
JSTBY1
JUIDB
J4
JD1
LED3
LEDM1
LED2
LAN2/4 LAN1/3
CPU1
CPU2
CPU2
CPU1
CPU2
CPU1
PWR I2C
UID
P2-DIMME1
P2-DIMMF2
P2-DIMMF1
P2-DIMMG2
P2-DIMMG1
P2-DIMMH2
P2-DIMMH1
P1-DIMMA2
P1-DIMMA1
P1-DIMMB2
P1-DIMMB1
P1-DIMMC1
P1-DIMMC2
P1-DIMMD1
P1-DIMMD2
USB4/5USB8/9
SLOT1 PCI-E 3.0 X8
SLOT2 PCI-E 3.0 X8
SLOT3 PCI-E 3.0 X8
SLOT4 PCI-E 3.0 X8
SLOT5 PCI-E 3.0 X8
USB6
TPM/PORT80
BUZZER
CMOS CLEAR
SLOT6 PCI-E 3.0 X8
COM2 USB2/3
COM1
USB0/1
SP1
CPU2
IPMI_LAN
CPU2
CPU2
Battery
BIOS
JPW1
JPW2
24-Pin Main PWR
8-Pin PWR
JPW4
P2-DIMME2
JPW3
8-Pin PWR
4-Pin PWR
L-SAS4~7 L-SAS0~3
LSI SAS CTRL
Intel
PCH
JPS1
LAN
CTRL
BMC
CPU1
X9DRD-7(J)LN4F
Rev. 1.01
JBOD Expansion Ports

1-6
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Asia-Pacific
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Tel: 886-2-8228-1366, ext.132 or 139

Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6047R-
E1R24L up and running. Following these steps in the order given should enable
you to have the system operational within a minimum amount of time. This quick
setup assumes that your system has come to you with the processors and memory
preinstalled. If your system is not already fully integrated with a serverboard, pro-
cessors, system memory etc., please turn to the chapter or section noted in each
step for details on installing specific components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6047R-E1R24L was shipped in and
note if it was damaged in any way. If the server itself shows damage you should
file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6047R-
E1R24L. It should be situated in a clean, dust-free area that is well ventilated.Avoid
areas where heat, electrical noise and electromagnetic fields are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6047R-E1R24L was shipped in should include two sets of
rail assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete the
installation process in a minimum amount of time. Please read this section in its en-
tirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for sufficient airflow and ease in servicing.
• This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).

2-2
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
!
!
Warnings and Precautions!
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the floor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack first, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
• Allow any hot plug drives and power supply modules to cool before touching
them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.

Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).

2-4
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
2-4 Rack Mounting Instructions
Rack Rails Assembly
This section provides information on installing the SC846 chassis into a rack unit
with the rails provided. There are a variety of rack units on the market, which may
mean that the assembly procedure will differ slightly. You should also refer to the
installation instructions that came with the rack unit you are using.
Note: This rail will fit a rack between 27" and 34.45" deep.
Identifying the Inner Rack Rails
The chassis package includes a rack rail assembly in the rack mounting kit. Each
assembly consists of an inner rail that secures to the chassis and an outer rail that
is attached directly to the rack.
Figure 2-1. Identifying the Rack Rails
Inner Rail Assembly

Chapter 2: Server Installation
2-5
Figure 2-2. Installing the Rails
Installing the Inner Rails on the Chassis
Installing the Inner Rails
1. Place the inner rails on the side of the chassis aligning the hooks of the chas-
sis with the inner rail holes. Make sure that the rail faces "outward" so that it
will fit with the rack's mounting bracket.
2. Slide the rail toward the front of the chassis.
3. Secure the rail to the chassis with four screws as illustrated.
4. Repeat steps 1-3 for the other inner rack rail.
1
1
1
2
1
3

2-6
SUPERSTORAGESYSTEM 6047R-E1R24L User's Manual
Installing the Outer Rails onto a Rack
Installing the Outer Rails
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
fits snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4. Repeat steps 1-4 for the remaining outer rail.
Secure to the
Front of the Rack
Secure to the
Rear of the Rack
Figure 2-3. Assembling the Outer Rails
Attach Outer Racks Together
Table of contents
Other Supero Network Storage Server manuals

Supero
Supero 6047R-E1R36L User manual

Supero
Supero SUPERSERVER 6027TR-H71QRF User manual

Supero
Supero 6027R-E1R12N User manual

Supero
Supero 6047R User manual

Supero
Supero SBB 937R-E2JB User manual

Supero
Supero SC417E16-RJBOD1 User manual

Supero
Supero SC417E16-R1400LPB User manual

Supero
Supero SC818G-1400B User manual

Supero
Supero SC213A-R900UB User manual

Supero
Supero SC846TQ-900B User manual