SW 2653 Series Manual

WALK-IN TUB MANUAL
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
INSTALLATION &OPERATING INSTRUCTIONS
INSTALLATION & OPERATINGINSTRUCTIONS
53
n Instructions
1-866-633-4882 www.meditub.com
100 East Mineola Avenue, Valley Strem NY 11580
MediTub
W h e r e S a f e t y M eets L uxur y
2646**
2653**
2739**
2747**
2753**
2851**
2853**
2952**
2953**
3053**
3054**
3153**
3060**
3140**
3238**
3260**
3660**
FOR
MODELS
DON’T WAIT!
REGISTER NOW!
Register your product within 90 days to ensure your bathtub is
coverage.
Mail in the completed registry card (Pg. 2) or register online
at www.SWCORP.com/register.
MANUAL IS FOR MULTIPLE
WALK-IN TUB MODELS.
IMAGE MAY VARY FROM
ACTUAL PRODUCT.
WI-3.5 THIS LATEST MANUAL VERSION
SUPERSEDES ALL PREVIOUS VERSIONS.
**

Page 2
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
PRODUCT REGISTRATION
PRODUCT REGISTRATION*
IMPORTANT:YOURWARRANTY WILLNOTBE RECOGNIZED UNLESS THIS CARD IS
FULLY COMPLETED AND RETURNED OR ONLINE REGISTRATION IS COMPLETED.
1. Register online at www.SWCORP.com/register. You will be asked to fill out the
same information you would in the registration card. Registering online is fast, secure
and ensures we receive your information.
2. Complete,cut-outandmailthe registrationcard below. Byreturningthisregistration
card we confirm the date of purchase for your new product. This confirmation will allow
us to process any warranty claims.
Mail the card to: 5701 NW 35 Avenue, Miami, FL 33142
PRODUCT REGISTRATION
Product Registration Card
Name ..................................................................................... Address ....................................................................................................................
City ............................................... State ........................... Zip ..............................
Phone ........................................... Email....................................................................
Date of Purchase........................... Order or Purchase #.................................................... SKU or Model #.........................................................
Installer’s Name..................................................................... Phone ................................................................................
I have read the Owner’s Guide carefully and understand and agree that any installation, operation or maintenance of the bathtub must be done strictly
in accordance with instructions and guidelines contained in the owner’s manual and installation guide.
Signature.............................................................................. Date..................................................................................
CUT ALONG
DOTTED LINE.

WALK-IN TUB MANUAL
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
TABLE OFCONTENTS
PRODUCT REGISTRATION.........................................................................................2
THANK YOU FORYOUR PURCHASE.............................................................................4
SAVE THIS MANUAL! ...............................................................................................5
UNPACKING THE UNIT..............................................................................................6
PRE-INSTALLATION .................................................................................................7
INSTALLATION PREPARATION ....................................................................................8
ELECTRICAL PREPARATION.......................................................................................9
INSTALLATION PROCEDURES ....................................................................................10
DRAIN CONNECTION................................................................................................11
CONNECTING THE AUTO DRAIN..................................................................................12
CONNECTING DOOR DRAIN .......................................................................................14
INSTALLATION AND EXTENSION PANELS ......................................................................15
FAUCET INSTALLATION.............................................................................................16
OPERATING SAFETY INSTRUCTIONS............................................................................17
OPERATING INSTRUCTIONS ......................................................................................19
TUB CONTROLS......................................................................................................20
CLEANING AND MAINTENANCE ..................................................................................21
WARRANTY...........................................................................................................22
RETURN POLICY.....................................................................................................23
TABLE OF CONTENTS
TABLE OF CONTENTS

Page 4
WALK-IN TUB MANUAL
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
THANK YOU & CONTACT INFORMATION
THANK YOU FOR YOUR PURCHASE!
The purchase of a walk-in bathtub is made out of a necessity for safety, comfort and quality of life. It is not a small investment but it
pays foritself by recapturing thepeace of mind and freedom you once had.
Our mission is to provide anyone with limited mobility the tools they needto once again enjoy the complete bathing experience.
To help ensure you get the most out of your investment below is list of ESSENTIAL DO’s and DON’Ts that must be kept in mind
during andafter your bathtub’s installation.
ESSENTIAL DO’S & DON’TS
DO REGISTER YOUR PRODUCT!
Register your product within 90 days to ensure your bathtub is recognized as an official purchase and is eligible
forwarrantycoverage.Mail the completed registry card (Pg. 2) or register online at www.SWCORP.com/register.
DO LEVEL THE TUB USING THE BUILT-IN LEVELING FEET TO PREVENT DOOR LEAKAGE!
Every walk-in bathtub comes equipped with adjustable leveling feet. THE LEVELING FEET MUST BE ADJUSTED TO
ENSURE THE TUB IS LEVEL AGAINST THE ONSITE FLOOR/SURFACE. FAILURE TO DO SO MAY RESULT IN LEAKAGE!
DO REPORT ANY DEFECTS, DAMAGES OR MISSING ITEMS RIGHT AWAY!
Thoroughly review the bathtub and contents of the package. Any defects or damages must be reported within 5
business days of receiving the product.
DON’T LIFT OR PULL THE BATHTUB BY THE PLUMBING!
Every walk-in bathtub is built with a steel support frame. This support frame features a set of handles which
should be used to lift, push and pull the bathtub to ensure no damage is done to the tub body, components or
plumbing.
DON’T LEAN OR SUPPORT YOURSELF ON THE BATHTUB DOOR!
The bathtub door’s alignment is key to providing a watertight seal. Using the door to support your weight or
leaving the door open for extended periods of time will compromise this alignment and possibly lead to leakage.
THANK YOU / CONTACT

Page 5
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
SAVE THIS MANUAL
SAVE THIS MANUAL!
READ THESE INSTRUCTIONS COMPLETELYBEFORE INSTALLING THE PRODUCTS.FAILURE TO DO SO COULDRESULTIN AN
IMPROPER INSTALLATIONAND COULD VOID THE WARRANTY.
RESPONSIBILITYOFTHE INSTALLER
THE INSTALLERMUST INSPECT AND WATER TESTTHEPRODUCTPRIOR TOINSTALLATIONTO ENSURETHEUNIT IS FREE OF
DEFECT OR DAMAGE. IN THE EVENT OF A PROBLEM, THE UNIT MUST NOT BE INSTALLED. IF THE CRATE OR THE PRODUCT
HAS BEEN DAMAGEDDURING SHIPPING, PLEASE CALL US IMMEDIATELY.
THIS PRODUCT MUSTBEINSTALLED BY ALICENSED/CERTIFIED CONTRACTOR
LICENSED PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION. INSTALLERS
ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES. ONLY ACCESSORIES AUTHORIZED BY THE
MANUFACTURER SHOULD BE USED WITH THIS PRODUCT.
WARNING!WHEN USING THIS PRODUCT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK, AND/
OR OTHER INJURIES.
IMPORTANT SAFETY INSTRUCTIONS. INSTRUCTIONS IMPORTANTES RELATIVES A LA SECURITE.
READ AND FOLLOW ALL INSTRUCTIONS.LIRE ET SUIVRE TOUTES LES INSTRUCTIONS.
SAVE THESE INSTRUCTIONS. CONSERVER CES INSTRUCTIONS.
WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING; CHILDREN SHOULD NOT USE HYDROMASSAGE BATHTUB
WITHOUT ADULT SUPERVISION. AVERTISSEMENT. RISQUE DE BLESSURE ET DE NOYADE. NE PAS LAISSER UN ENFANT
UTILISER LA CUVE A REMOUS EN L’ABSENCE D’UN ADULTE
WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING THE HYDROMASSAGE BATHTUB.
AVERTISSEMENT. POUR EVITER LES BLESSURES, USER DE PRUDENCE EN ENTRANT DANS LA CUVE A REMOUS ET EN LA
QUITTANT.
WARNING:RISKOFELECTRICSHOCK;DONOTPERMITELECTRICAPPLIANCES(SUCHASAHAIRDRYER,LAMP,TELEPHONE,
RADIO,ORTELEVISION)WITHIN1.5MOFTHISHYDROMASSAGEBATHTUB.AVERTISSEMENT.RISQUEDECHOCELECTRIQUE.
NE PAS PLACER D’APPAREILS ELECTRIQUES (LUMINAIRE, TÉLÉPHONE, RADIO, TELEVISEUR, ETC.) A MOINS DE 1.5 M DE
CETTE CUVE A REMOUS.
CAUTION:TESTTHEGROUNDFAULTCIRCUITINTERRUPTERPROTECTINGTHISAPPLIANCEPERIODICALLYINACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS. ATTENTION. VERIFIER REGULIEREMENT LE FONCTIONNEMENT DU
DISJONCTEUR DE FUITE A LA TERRE CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT.
SAVE THIS MANUAL

Page 6
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
UNPACKING
UNPACKING
UNPACKING THE UNIT
USEFRAMEHANDLESTOLIFT/MOVE
TUB. NEVER BY THEPLUMBING!
Never lift the walk-in bathtub by the plumbing. Doing so
may result in damaging theplumbing and causing a leak.
INSPECTING THEUNIT
Immediately inspect the unit for damage even if there is
no carton damage. If any damages are noted, photograph
the damaged area(s) and notify us immediately. Damages
must be reported within 5 business days. Once the unit is
installed surface damages will be assumed to be installation related if not reported at this point.
PLACING THE UNIT
Please note that an installer(s) assumes full liability fordamages tothewalk-inbathtub after the unit is installedin the “cradle”/niche.
WHAT’SINSIDE
Inside you’ll shouldfind thefollowing:
Model 30x53
Installation Instructions
P: 1-866-633-4882 www.meditub.com
100 East Mineola Avenue, Valley Strem NY 11580
MediTub
W h e r e S a f e t y M eets Luxur y
• Walk-In BathtubUnit
• Walk-In BathtubExtension Kit (if applicable)
• Waste & Overflow Kit
• Sanitary Tee
• Door Drain Adaptor with 3/8”Barb
• Faucet Set (if applicable for model)
• Suction Cup Handle
• Owner’s Manual (with Registration Card)
USE THESE HANDLES
TO LIFT TUB.
DO NOT LIFT BY
PLUMBING!

Page 7
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
SAFETY
SAFETY
PRE-INSTALLATION*
* All walk-in bathtubs are 100% water tested at the factory certified to be free of leaks.
Transportation and mishandling may cause leaks. It is necessary to test the bathtub
while there is access to all sides of the bathtub.
TEST THE BATHTUB WHILE YOU HAVE ACCESS TO ALL
SIDES AND BEFORE PERMANENTLY INSTALLED.
READ AND FOLLOW ALL INSTRUCTIONS
• Place the tub on a completely flat surface in anarea where it may be drained after testing.
• Close the drainand fill the tub until it is above the highestjet. If it’s a soaker fill up to normal water height level.
• Allow the water to stand in tub for 30 minutes andthen inspect all plumbing and seals for leaks.
• If tub is jetted, supply electric to unit and run for 10 minutes and inspect for leaks. Inspect the unions around the pump; ifleaks
persist from the unions after tightening; loosen the unions and insure the O-ring is seated properly.
NOTE: IF THE PUMPSDO NOT OPERATE, CHECK THE BREAKERTO ENSUREPOWERIS ON ANDTHE CABLE CONNECTING THE
CONTROLS TO THE PUMP IS ATTACHED.
WARNING! DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER
LEVEL. DAMAGE DUE TODRY RUNNING PUMPSISNOT COVEREDUNDER WARRANTY.FAILURE TO
PERFORM THESE TESTS BEFORE INSTALLATION WILL MAKE THE INSTALLER LIABLE FOR FUTURE
REPAIR COSTS.

Page 8
WALK-IN TUB MANUAL
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
INSTALLATION PREPARATION
INSTALLATION PREPARATION
ABAD LEVEL WILL MAKE YOUR TUB LEAK!
1. CHECK FLOOR LEVEL
2. ADJUST LEVELING FEET ASNEEDED
Clear the floor of any debris or trash and use a 5-6 foot level to determine if the floor is level. If the
floor is not level, it is imperative that the bathtub’s leveling feet are used to ensure the tub itself is
perfectly level.
systemto workproperly.
1. Check toensure that the drain piping has been “roughed-in” atthe proper location.
2. Ensure that the proper electrical service has been installed at the pump location. See electrical requirements in the manual (on
following page).
Adjust leveling feet as needed making sure all feet are completely

Page 9
WALK-IN TUB MANUAL
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
ELECTRICAL PREPARATION
ELECTRICAL PREPARATION
Allelectrical wiringmustbeinstalledinaccordancewiththeNationalElectrical Code andwithalllocalcodes.Allwiringshallbedone
by a qualifiedelectrician.Run one,twoorthree branchcircuits(asrequired) from themain electricalservicepanelto thepumparea
of the framing structure to provide power to the unit.
Electrical components have specific wiring requirements. Refer to the matrix below for the electrical supply requirements for the jet
massage bathtub and factory installed components.
Branch circuits must be rated for 110 – 120 volts. Use 12 Gauge, 3 conductor cable for the circuits. If the length run exceeds 100
feetcheckwithlocalcodesforrequirements.Installmoistureproofjunctionbox(s)6”abovetheflooratthepumpendoftheframing
for each circuit.
NOTE: DO NOT INSTALL THE JUNCTION BOX(S) WHERE IT CAN BE REACHED WHILE SITTING OR STANDING IN THE TUB OR
TOUCHING THE FAUCETS.
AUTO DRAIN™, LIGHTS, WHIRLPOOL, AIR SPA, COMBO & HEATER ELECTRICAL
REQUIREMENTS
This section lists the factory installed components of the Jet Massage and/or Air Massage Systems.
Systems Electrical Ra ng
Circuit 1
Dedicated
Circuit
Soaker w / Auto Drain™ 15 Amp GFCI
Soaker w / Light
15 Amp GFCI
Soaker w / Auto Drain™ w / Light 15 Amp GFCI
Jet Massage Or Air Massage
15 Amp GFCI
Jet Massage Or Air Massage w / Light 15 Amp GFCI
Jet Massage Or Air Massage w/ Auto Drain™
15 Amp GFCI
Jet Massage Or Air Massage w/ Light & Auto Drain™ 15 Amp GFCI
Jet Massage & Air Massage (Dual)
20 Amp GFCI
Jet Massage & Air Massage (Dual) w/ Light 20 Amp GFCI
Jet Massage & Air Massage (Dual) w/ Auto Drain™
20 Amp GFCI
Jet Massage & Air Massage (Dual) w/ Light & Auto Drain™ 20 Amp GFCI
Whirlpool Inline Heater - Dedicated 15 Amp Circuit
15 Amp GFCI
All electrical connectionsmust be carried out b y a certifiedelectricianin accordance with local electrical requirements andcodes.
ELECTRICAL PREPARATION

Page 10
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
INSTALLATION PROCEDURES
INSTALLATION PROCEDURES
INSTALLATION PROCEDURES
WARNING!WHEN INSTALLING A JETTED WALK-IN BATHTUB, THE FOLLOWING BASIC
PRECAUTIONS SHOULD BE FOLLOWED.
DANGER! RISK OF ELECTRIC SHOCK. CONNECT ONLY TO SEPARATE CIRCUIT PROTECTED BY A
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) ON PLUG IN UNITS.
NOTE: INSTALLATION MUSTPROVIDE ACCESS FOR SERVICING PUMP/MOTOR (ALL TUBS COME WITH AN ACCESS PANEL
FOR THE PUMP/MOTOR).
GENERAL GUIDE-THROUGH
• Install tub waste/overflow according to instructions (see page 11).
• After framing is a complete (see attached diagrams), set product in place to make certain the tub can be
properly leveled. (Caution: If a walk-in bathtub is not resting on all leveling feet, water will not drain properly
and may cause the door to leak) (see page 8).
• Verify the product’s level by checking tub’s deck surface and ensure all leveling feet are touching the
ground (see page 8).
• Electrical connection is made pre-instruction on specified models.
• After plumbing and electrical connections have been made, the tub should be cleaned of dirt and debris.
• Installation is not complete until the tub has been tested in place.

Page 11
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
DRAIN CONNECTION
Toensuresafetransitforyourwalk-intub,the overflowdraincomponentsarenotconnectedtothe unitduringthe
process of production. The following instructions are provided for installation purposes:
Your walk-in tub is supplied with a 1 ½” drain pipe overflow.
1. The open and close valve with the turn knob should be attached to the unit at the 1 ½” pre-drilled opening in
the wall of the unit from the outside.
2. Theoppositeendof the overflowshouldbeattachedtothe1½”pre-drilledopeninginthe footwellof the unit
from the underside.
3. The chrome turn knob and the drain cover should be attached to the appropriate ends of the overflow drain
from the inside of the unit.
4. Place the chrome cap with stem into the floor drain to close off the opening.
5. The cable attached to the turn knob of the overflow is also connected to a lever inside the floor drain which
allows the drain to be opened or closed.
6. Once the components of the overflow are secured into place, turn the overflow knob to the open and closed
position to ensure proper function. The cap and stem will move up and down, opening and closing the drain
(Figure 1). overflow
draincable
drain cable drain
drain shoe
draintee
Parts Provided
Not Provided
FIGURE 1

Page 12
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
CONNECTING THE AUTO DRAIN
1. Drain System requires the connection to a minimum 1 ½sanitary drain line.
2. Use UPC Approved PVCGlue, primer, and Schedule 40 1 ½ ’ pipe.
3. Do not change or modify the location and orpipingofthe Back Flow Preventer.
4. The sanitary tee is installed directly above the draintee with clearance not greater than1’’.
5. Dry fit the drainoverflow assembly to the sanitary drainage pipe and check for proper fit.
6. Glue the High-Speed Auto drainFittings, pipe anddrain overflow assembly to the sanitary drainage pipe.
7. Reference figure 2 for connectingautodrain in a soaker or air jetted tub. (page 13)
8. Reference figure 3 for connectingautodrain in a hydro ordual jettedtub. (page 13)
• NOTE:WATER TIGHT INSTALLATION OFTHEWASTE/OVERFLOW ISTHEINSTALLER’SRESPONSIBILITY.
DRAIN LEAKAGE IS EXCLUDED FROM MEDITUB WARRANTY OFTHIS PRODUCT.
WARNING:WE HAVE TAKEN RESPONSIBLE PRECAUTIONS TO ENSURE THE HIGH-SPEED AUTO DRAIN IS
SUITABLE FOR RESIDENTIAL PLUMBING. IT IS THE RESPONSIBILITY OF THE INSTALLER TO INSURE THE
SANITARY SYSTEM IS ACCEPTABLE FOR THE USE OF THE HIGH-SPEED AUTO DRAIN. WE DO NOT ACCEPT
RESPONSIBILITY FOR DAMAGE ARISINGFROM THE USE OF THE HIGH-SPEED AUTO DRAIN.*
*-Ensure compliance with local plumbing codes.
diverter valve
jets
overflow
draincable
drain cable drain
drainshoe
sanitary tee
drain tee
reducer
Parts Provided
Not Provided
back flow preventer
110V-60hzpump

Page 13
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
button (on/off)
reducer
110V-60hzpump
Parts Provided
Not Provided
button (on/off)
overflow
draincable
drain cable drain
drain shoe
sanitary tee
drain tee
back flow preventer
110V-60hz pump
FIGURE 2
SOAKER & AIR JET
AUTO DRAIN CONNECTION
FIGURE 3
HYDRO & DUAL JET
AUTO DRAIN CONNECTION
button (on/off)
diverter valve
jets
overflow
draincable
drain cable drain
drain shoe
sanitary tee
drain tee
reducer
Parts Provided
Not Provided
back flow preventer
110V-60hz pump
Parts Provided
Not Provided
overflow
drain cable
sanitary tee
drain tee

Page 14
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
DOOR DRAIN CONNECTION
Your walk-in tub also has a door drain to remove excess water from the door after each use.
1. Fromtheunderside oftheunit,ahoseis connectedtothedoordrainwithacheckvalve.This hoseandvalveis toprovide aone-
way flow from the door drain to the main drain pipe. The check valve will constrict the water flow away from the door.
2. Insert the opposite end of the hose into the port on the main drain. Be sure the port is open before attaching the hose. Secure
the hose with clamps or ties.
3. Oncethe hoseis in place, closethedoor ontheunit, placethe handlein thelockedposition, and filltubwith atleast12” ofwater
to test the connection.
4. Oncethecompletionof thedraincomponentsareinstalledandhavebeentestedforproperfunction,theunitcanbeleveledand
give a final water test before installation of unit (Figure 4).
FIGURE 4
Overflow Pipe
Sanitary
Tee
Flow
Connect door drain to
floor drain pipe from
about a45° angle.
Do not connect from
directly above because
it may hinder flow.
Do not connect from below
45° as water will fall back
into the door drain tube.
Check Valve
DoorDrain
ConnectionPipe
Flow
Floor Drain
Door Drain
Walk-inBathtub

Page 15
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
INSTALLATION AND EXTENSION PANELS
ASSEMBLY &PLACEMENT
Connect the two panels using pre-drilled holes:
Inner flange
Top panel
Side panel
Wall
Bathroom (Waterproof) Sheetrock
Mortar
Tile
Silicone
Screw**4mm screws
notincluded
2-piece extension panels
Molded flange to bolt unit to wall
Custom-built wall section(s) for open ends or
install against corners of full wall.
Every bathtub must be installed with a tile flange.
If the bathtub does have a tile flange then a tile
flange kit may be purchased separately.
Please call 305-614-4070 to inquire about the
tile flange kit.
The tile flange should be installed on the tub
before it is placed in the alcove. Install the tile
flange along all sides of the tub where the wall
will be. Measure to fit and miter cut the flange
corners. The flange should be attached to the
tub with a silicone adhesive.

Page 16
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
FAUCET INSTALLATION
fixing nut
fixing nut
hotcontrol handle shower head
fiber washer
metal washer
rubber washer
metal washer rubber washer
metal washer
valve bodygasket
3/4”
connection connection connection
1/2” 3/4”
72” shower hose
hot water
spout
diverter
cold control handle
fixing nut
cold water
fixing nut
valve body
valve body
local water line
(notincluded) steel braided 19” hose
steel braided 19” hosesteel braided 19” hose
local water line
(not included)
fiber washer
metal washer
rubber washer
rubber o-ring
rubberwasher
rubber o-ring

Page 17
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
OPERATING SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK OR INJURY
TO PERSONS
WARNING!RISK OF PERSONAL INJURY:
• Usethis unitforitsintendeduseasdescribedinthis manual. DONOTuseattachmentsnotrecommendedbythemanufacturer.
• To avoid injury, exercise caution when entering or exiting your walk-in tub.
• To reduce the risk of injury, do not permit children or persons with infirmities to use this product unless they are closely
supervised at all times.
• The maximum recommended temperature is 102 F° (38.8 C °). Fifteen minutes per soak is the recommended maximum time at
102 F°, which may induce Hyperthermia which is an increase in body temperature. This can be a serious medical condition and
all bath users are cautioned against lengthy immersion at high water temperatures. Should you become light-headed, dizzy, or
nauseous, immediately get out of thebath and cooloff.
• Risk of electric shock; do not permit electric appliances (such as a hair dryer, lamp, telephone, radio or television) within four
feet of this bathtub.
• Never drop or insert any objects into any openings.
• Do not operate this unit without the guard over the suction fittings.
WARNING!RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. People usingmedications,herbal remedies,sleepaids,
and /or having adverse medical history should consult a physician before using this product.
WARNING!NO FOOD OR ALCOHOLIC BEVERAGES. Useofyourbathtubimmediatelyaftermeals is notrecommended. Avoid
alcohol consumption before or during the bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of
consciousness or even drowning.

Page 18
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
OPERATING SAFETY INSTRUCTIONSCONTINUED
The unit must beconnectedonlytoasupplycircuitthatis protectedby a ground-fault circuit-interrupter (GFCI).Such aGFCI should
be providedbytheinstallerandshould betested onaroutinebasis. TotesttheGFCI,pushthe testbutton.TheGFCI should interrupt
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, there may be a ground current
flowing, indicating the possibility of an electric shock. Do not use this massage bathtub. Disconnect the jet massage bathtub and
have the problem corrected by a qualified service representative before using.
Toreducetheriskofelectricalshock, thededicated electrical supplycircuit(s) mustbe grounded. Todo this,connectthethirdleg of
the 3-conductor wiring cable to the grounding terminal of the electrical service panel and run continuously to the green grounding
screw on the GFCI or electrical receptacle in the wiring compartment.
IN-LINE HEATERS
If your bathtub is equipped with an in-line heater, it will operate only when the pump is on.
NOTE: THE IN-LINE HEATER IS DESIGNED TO KEEP YOUR WATER WARMER LONGER, BUT IS NOT DESIGNED TO INCREASE
THE WATER TEMPERATURE. HEAT SETTINGS ARE NOT ADJUSTABLE.

Page 19
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
OPERATING INSTRUCTIONS
When entering the walk-in tub, be sure to close the door, placing the
handleinthedownposition.Beforeactivatingany ofthejettingcontrols,
you must first fill the bath to a water level at least 2 inches above the
highestjet placement. Donotput weighton thedoor when enteringand
exiting the tub.It is recommendedto leave the door in the openposition
when the tub is not in use.
The pump is operated by the hydro control button, which starts the
waterflow.Thebloweris operatedbytheaircontrol button whichstarts
the air flow (see page 20).
Adjustthedirectionandrateofflowofthejetsbymoving thenozzlefordirection.Turneithertheoutside ring orthenozzleclockwise
or counterclockwiseforflow(somejetsadjust theflow with theoutside ring andsome withthe nozzle).Adjust theairpressure flow
of all water jets by using the (see page 20), which controls air-water mixture.
Our walk-in tubs equipped with the chromotherapy lights (ordered separately), feature a dedicated on/off switch. Pressing the
switch off and back on willchange the color of light (see page 20).
EXAMPLE TUB DOOR HANDLE

Page 20
WALK-IN TUB MANUAL
OPERATING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 305-614-4070 • Fax 866-560-1060
NANO2BUBBLES (PUMP)
Used to turn the micro-bubbles ON and OFF. Note: Activating
NANO2BUBBLES will turn off hydro jets, automatically.
HYDRO CONTROL (PUMP)
Used to turn the water jets ON and OFF.
AIR CONTROL (BLOWER)
Used to turn the air jets ON and OFF.
CHROMATHERAPY LIGHT
PRESS ONCE (when light is OFF) - Turns light ON in Auto-
Cycle Mode which will slowly transition from color to color.
PRESS TWICE (when light is ON)- Turns on static, non-
changing color mode. Continue to press twice to move on to
the next color until you find your desired choice.
PRESS ONCE (when light is ON) -Turnsofflight.Resets cycle
after 2 second pause.
HYDRO JET FLOW CONTROL
Used to increase or decrease air pressure flowing through the
water jets.
FOR TUBS WITH NANO2BUBBLES OPTION.
FOR TUBS WITH WATER JET OPTION.
FOR TUBS WITH AIR JET OPTION.
FOR TUBS WITH CHROMATHERAPY LIGHT OPTION.
FOR TUBS WITH WATER JET OPTION.
FOR TUBS WITH AUTO DRAIN OPTION. FOR TUBS WITH AROMATHERAPY OPTION. FOR TUBS WITH HEATED BACKREST OPTION.
AUTO DRAIN DIVERTER
While the HDYRO PUMP is running, use
this diverter to channel the pumped water
throughtheHYDROJETSordownthedrain.
AROMATHERAPY CAP
Unscrew cap and insert your favorite
fragrance beads to bathe in a soothing
aroma scent.
HEATED BACKREST
UsedtoturnheatedpadsONandOFF.Will
turn off after 20 minutes. Note: Light may
blink for 2 seconds and turn off. This just
indicates system is initiating. Simply press
the button again to activate heating pads.
1
2
3
4
5
TUB CONTROLS
OPERATING INSTRUCTIONS
5
4
3
2
1
This manual suits for next models
27
Other SW Bathtub manuals
Popular Bathtub manuals by other brands

Kohler
Kohler Memoirs K-724-G0 manual

Artweger
Artweger T2W10 Series Assembly instructions

Longevity
Longevity 6634QDS installation instructions

Kohler
Kohler Sterling Unwind 96129-0 installation guide

DURAVIT
DURAVIT Cape Cod 7 0330 Series Mounting instructions

American Standard
American Standard Virtuoso Elite Whirlpool 7236E Series installation instructions