Syris SY120SA User manual

ADD : 12F, No. 12, Sec. 1, Taijunggang Rd.Taichung, Taiwan (403)
TEL : +886-4-2207-8888
FAX : +886-4-2207-9999
Website : http://www.syris.com
SYRIS Technology Corp.
SYRIS SY120SA
Ver 0322:
Operation Manual

1.Login/Logout Procedure & Longin Password alter ………...……………………Page 1
2.Add Card Operation Procedure ………………………………………………...…..Page 2
3.Delete Card Operation Procedure ………………………………………………...Page 2
4.Modify Card Operation Procedure ……………………………………………….Page 3
5.System DI Function Setup ………………………………………………………..Page 4
6.System DO Function Setup ………………………………………………………Page 5
7. System Group and Timer Function Setup ……………………………………Page 6
8.Setup Card Number with Password Open Door Way …………………………Page 7
9.System Default…………………………………..………………………….......…… Page 8
10.Steal Alarm System Function Setup …………………………………………….Page 8
11.Anti-Force Function Setup ……………………………………………………......Page 9
12.Enternal Function Setup ………………………………………………………...Page 9
13.System Communication Identify Number Setup ……………………………….Page 9
14.SY120SA and Other SY120SA Connection Diagram …………………………..Page 10
15.SY120SAand MD120EXT-1S Connection Diagram …………………………...Page 10
16.SY120SA and SYRDK5 Connection Diagram …………………………………Page 11
**This is simple version of the instruction manual, for more detail information please check the complete
version in the CD-ROM**
SY120SA SINGLE DOOR CONTROLLER
SY120SA Basic Operation Manual

-1-
1-1 System login
1-2 System logout
1-3 Alter the Login Password
Enter FUN + + EN , the “OK” pilot lamp flashes and wait for enter password.
Enter password(preset 1234) + EN, and CALL key flashes, it means login success.
Example login procedure
FUN+ +EN+ +EN
Repeat enter FUN + + EN after setup procedure to logout
The login password preset three set, the beginning value are all set to 1234, suggest alter
the three set password before using and avoid the unconcerned personnel to login system,
the password alter method as following :
Use preset password(1234) login and enter FUN + + NNNN + NNNN + EN
(NNNN new password , enter second time as confirm action)
Then enter FUN + + EN to logout system to complete the first group password wetting.
The second and third password as the above procedure, repeat use preset password 1234
to login then modify three times as modify three groups password, please use new password
to login after alter.
Example use preset password to login
FUN+ +EN+ +EN
modify password to 5678
FUN+ + + +EN
logout
FUN+ +EN
2
:
:【 】
2 1234 。
2
41【】【】,
:
2
:【 】
2 1234
【】
41 5678 5678
【】
2
SY120SA SINGLE DOOR CONTROLLER
1.Login/Logout Procedure
System
login
Enter
password
System
logout END
Start

-2-
System
login
Delete
card
System
logout END
Start
2-1 Add One Card
2-2 Add Multi Cards
Enter FUN + 3 1 + NNNN + G + EN then proximity to one card.
NNNN Assign add card number, range: 0001~2000
G Assign card group number, range : 1~4.
Example add one card sequent number0001, and set to group1
FUN+31+0001+1+EN,proximityoneun-usecard.
Enter FUN + 3 5 + NNNN + G + EN and proximity card one by one.
NNNN assign card serial numbers from 0001~2000.
G assign card group number, range : 1~4.
Example add five card from sequent number 0002 and set to group1
FUN+35+0002+1+EN,proximityfiveun-usecards
The sequent number will automatically edit 0002 to 0006, the group all set to1.
【】【】
:.
:
:【 】
【】【】
:
:
:【 】
3.Delete Card Operation Procedure this function needs to operate under login status【】
3-1 Delete One Card
Enter FUN + + NNNN + EN.
NNNN assign the card number which wants to delete, range : 0001~2000.
Example delete one card of sequent number 0001
FUN + + + EN.
32 【 】
:
:【 】
32 0001
SY120SA SINGLE DOOR CONTROLLER
System
login
Proximity
card
Add
card
System
logout END
Start
2.Add card operation procedure this function need to operate under login status【】

-3-
4-2 Modify One Card
4-3 Modify Multi Card Group
Enter FUN + NNNN + S + EN
NNNN assign the card number which want to modify the card status; rnage:0001 2000.
S S=1setupcardenable S=0setupcarddisable
Example disable the sequent number 0002 card
FUN + + + EN
restart the sequent number 0002 card
FUN + + + EN
Enter FUN + + NNNN + EEEE + G + EN .
NNNN
EEEE
G assign the new group number of card; range : 1 4.
+34【 】【】
: ~
:;
:【 】
+34 0002 0
【】
+34 0002 1
37 【 】 【 】 【 】
:
:
:~
assign the begin card number of card group which wants to modify; range :0001 2000
assign the end card number of card group which wants to modify; range : 0001 2000
~
~
SY120SA SINGLE DOOR CONTROLLER
System
login
Modify
card
System
logout END
Start
3-2 Delete Multi Cards
Enter FUN + 3 6 + NNNN + EEEE + EN.
NNNN assign the begin card number which wants to delete, range : 0001~2000.
EEEE assign the end card number which want to delete, range 0001~2000.
Example delete cards of sequent number from 0002~0006
FUN+36+0002+0006+EN.
【】【】
:
:
:【 】
4.Modify Card Operation Procedure this function nees to operate under login status【】
4-1 Modify One CardGroup
Enter FUN + NNNN + G + EN
NNNN assign card number which wants to modify in the card group, range :0001~2000.
G assign the new group number to card, range: 1~4.
Example modify the original card sequent number 0001 in group 1 to group 2
FUN + + + EN
+33 【 】 【 】
:
:
:【 】
+33 0001 2

-4-
EnterFUN+ +K+F+J+EN.
K the DI sequent number which wants to set up, range: 1 8.
K=5asSY120SA CALL key K=6asexpandkeypad reader CALL key
K=7asexpandDI#1 K = 8 as expandDI#2.
F DI purpose number, please refer the below DI purpose table.
J 0 for set to NO default , 1 for set to NC.
61 【 】 【 】 【 】
:~
;;
;
:
:()
DI Purpose Table
Number Purpose Notation
0Notuse
1 Door detect (DI1 preset)
2 Open door button (DI2 preset)
3 Emergency open door button Open door and send out alarm until relief
4 Steal alarm set up status detect Detect if complete deploy
5 Doorbell DI (CALL key preset)
6 Emergency call button Send out alarm until relief
7 One area alarm detect Send out alarm until relief deploy status)
8 Two area alarm detect Send out alarm until relief deploy status)
9 Anti- force detect Send out alarm until relief
(
(
SY120SA SINGLE DOOR CONTROLLER
System
login
System
input
setting
System
logout END
Start
4-4 Modify Multi Cards
Enter FUN + + NNNN + EEEE+S+EN.
NNNN assign the begin card number of card status which wants to modify; range:0001 2000
EEEE assign the end number of card status which wants to modify; range: 0001 2000.
S S=1setupcardenable S=0setupcarddisable
Example disable the sequent number 0003~0006 cards
FUN+++++EN.
38 【 】 【 】 【 】
: ~
: ~
:;
:【 】
38 0003 0006 0
5. System DI Function Setup this function needs to operate under login status【】
Example modify the original sequent number 0003~0006 cards of group 1 to group 2
FUN + + + + + EN .
:【 】
37 0003 0006 2

System
login
System
time
setup
Start
Number Purpose Notation
0Notuse
1 Open door control (electric lock DO preset)
2 Doorbell contact output (relay DO preset)
3 Burglar alarm output Deploy and withdraw controlled
4 Alarm contact output Use withdraw to cancel alarm
5 Anti-force contact output Use[FUN][4][4]to cancel anti-force alarm
Action time set “0” for keeps action until relief※
Example
DIFUN+ ++++EN
DO FUN+ + + + +EN
:【 】
: 61120
: 7121003
set up expand open door button, action time 3seconds (set up DI and DO together)
7. System Group and Timer Control Function Operation this function needs to operate under
login status
【
】
SY120SA SINGLE DOOR CONTROLLER
System
login
System
output
setting
Group
time
setup
Timer
setup
System
logout
System
logout
END
END
Start
6. System DO Function Setup this function needs to operate under login status【】
EnterFUN+ +K+F+TTT+EN.
K The DO sequent number which wants to set up;
K=1aselectriclockDO,
K=2asrelay DO,
K=3asexpand relay DO,
K=4aspre-saveDO
F DO purpose number, please refer the below DO purpose table.
TTT DO action time set up, range: 000 255, unit: second; default electric lock DO for 5
seconds, relay DO for 2seconds.
71 【 】 【 】 【 】
:
:
:~
DO Purpose Table
-5-

SY120SA SINGLE DOOR CONTROLLER
7-1 System Ttime Setup
EnterFUN+ +YYYY+MM+DD+hh+mm+ss+EN
YYYY year, range: 2000 2199. MM month, range: 01 12.
DD day, range: 01 31.
hh hour, range: 00 23.
mm minute, range: 00 59.
ss second, range: 00 59.
Partly week automatically count by controller
Example: set up April/15/2004 time: 16:30
FUN++ ++++++EN
81【 】【】【】【】【】【】
:~():~
:~
:~
:~
:~
【】
81 2004 04 15 16 30 00
※
7-2 Timer Setup
7-3 Group timer set uo ( passage way setup )
Enter FUN + + HHMM + hhmm + EN
HHMM the time setting of timer begin; hour/mintue; default 0700
hhmm time setting of timer end; hour/mintue; default 1900
Example set up timer from 8am to 6pm
FUN + + 0800 + 1800 + EN
Enter FUN + + G + D + N + A + EN
G groupnumber(1~4)
D intimer(0~3)
N outoftimer(0~3)
A door passage, 1= pass enable preset , 0= pass disable
82 【 】 【 】
:
:
:【 】
82【】【】
83 【】【】【】【】
:
:
:
:()
※
※
※In and out of timer function table
0 Can not pass
1 Card or password
2 Card (system default)
3 Card and password
7-4 Holiday Setup
Enter FUN + + HH + MMDD + EN.
HH holiday sequent number, range: 01 30, if set to “00” is for clear all holiday setting.
MMDD The holiday date which wants to assign to the sequent number
Example set up holiday sequent number 01 define new year
FUN+++ +EN
85 【 】 【 】
:~
:
:【 】
85 01 0101
-6-

-8-
SY120SA SINGLE DOOR CONTROLLER
Burglar
system
operation
Proximity
card END
Start
Enter pppp + nnnn + nnnn + EN
pppp thoe original old password or system first set up password; default deifne 0000
nnnn new password, enter twice to confirm.
Example card password alter from 0000 to 5678
After proximity card then enter + + + EN
The card password change from 0000 to 5678
group set up open door mode to password open door mode
Enter NNNN + pppp + nnnn + nnnn + EN , the system will decide correct or
not, and will response correct status and modify the old password to new password.
NNNN effective card number, 0001 2000
pppp the orginal password or system preset password (default password is 0000)
nnnn new password, enter twice to confirm.
Example the password of card number 0001change from 5678 to 2468
Enter++++EN
The card passowrd change from 6578 to 2468.
【】【】【】
:
:
:
0000 5678 5678
【】
【 】【】【】【】
:~
:
:
:
0001 5678 2468 2468
9. System default
Under login status, enter FUN + + EN, it will response the correct status if correct;
then enter FUN + + EN again and wait for ten seconds to clear all setting and restore
to default.
9-1 Clear all setting and restore to default (including card data, parameters, and I/O data…etc.)
49
49
10. Steal Alarm System Function Setup
10-1 Steal Alarm system relief withdraw
10-2 Start Steal Alarm System deploy
【】
0
【】
1
Enter FUN + + EN, the OK pilot lamp flash once, the warning light go out after proximity
card then burglarproof system complete relief.
Enter FUN + + EN, the pilot lamp flash once, after proximty card the warning light
flashes, the burlgarproof system start operating complete.
8-3 Enabled or Disable Encryption Card
(V3.0)
Enter[FUN][4][8](E) [EN]
(E): E=0 EM/TEMIC Card (default); E=1 Use SYRIS Encryption Card;
E=2 Use Security Encryption Card

-7-
SY120SA SINGLE DOOR CONTROLLERSY120SA SINGLE DOOR CONTROLLER
System
login
Card
number
encryption
setting
System
logout END
Start
7-5 Group weekly plan
Enter FUN + + G + WWWWWWW + H + EN
WWWWWWW
G group number; range: 1 4.
H holiday control, 1= can pass default , 0= can not pass
Example set up group 1 normal passage from Monday to Friday, Staturday, Sunday and
holidaycan not pass
FUN + + + + + EN
84 【 】 【 】 【 】
:
:~
:()
:【
】
84 1 0111110 0
weekly plan from Sunday to satruday, 1= can pass default , 0= can not pass()
8. Set up card number and password open door way
this function nneds tooperateunder login status【】
8-1 Use card number plus password to open the door or password only to open the door
8-2 Alter user preset password default define 0000
need to set up group for card or passage way (for the set up method please refer to 8-3)
Enter FUN + + P + EN .
P P = 1 as use card number and password(default) P = 0 as direct password open door.
Example if already set up card or password opne door then st up card number and
password opendoor
FUN + + + EN
now, before use password to open the door, it requires to enter the card number with
password. For example: first, enter the user's card number, then enter the default password
number to open the door
++EN
Enter FUN + + nnnn nnnn + EN
nnnn new password, enter twice to confirm
Example FUN + + + + EN
alter one card password setting(no need to login, can operate under normal status )
The situation of group set up open door mode as card and password
Proximity the card which wants to set up or modify, the card reader will displays wait for
password enter status and stop read card function,
※
※
※
51 【 】
:;
:【
】
51 1
0001 0000
()
52【】【】
:
: 52 3456 3456
【 】

-9-
SY120SA SINGLE DOOR CONTROLLER
Anti-
force
setting
Setup
ID
System
logout
System
logout
System
login
System
login
END
END
Start
Start
11. Anti-Force Function Setup
11-1 Anti-force password start using
11-2 Set up anti-force alarm
Enter FUN + + + EN.
G: anti-force password group, range: 1~4.
PPPP: enter anti-force password.
system default 1-4 groups all define 5555. If personal password the same with
anti-force password, it will take as presonal password.
Enter FUN + + + EN.
E=1 execute anti-force alarm E=0 cancel anti-force alarm default .
Example enter anti-force password to start the DO which we choose(relay DO default)
Anti-force password start using FUN + + + EN.
Execute anti-force alarmFUN + + + EN.
DOFUN+ +++ +EN
43 G PPPP+
44 E
:;:()
:【 】
43 G 5555+
44 1
: 7125003
※
12. Expand Function Set up
12-1 Expand module Setup
12-2 Expand Card Reader Setup
Enter FUN + + + EN
E=1 has external expand module E=0 no external expand module default
Enter FUN + + + EN
standard card reader keypad card reader default
57 E
:;:()
59 S
S=1: ;S=0: ( )
13. System Communication Identify Number Setup
91
: 001~999; 001
Enter FUN + + (NNN) + EN
(NNNN) controller identify ID , range: preset .

-10-
SY120SA SINGLE DOOR CONTROLLER
14.SY120SA and Other SY120SA Wiring Diagram
15.SY120SA and MD120EXT-1S Wiring Diagram
M6
MD485-USB
USB
+8 ~ 15V Red
GND Black
RS-485(-) Green
RS-485(+) Yellow
GND Black
Connect to DC Power
PC
Windows 98/Me
Windows 2000/XP
SY120SA
SY120SA
SY120SA
GND
+12 Vdc
GND
+12 Vdc
GND
+12 Vdc
MD120EXT-1S
RELAY
D03
DI7 Blue
DI8 Brown
NC Green
COM Blue
NO Violet
DI-DI / DO-DO WIRING MAX 5M
DO Orange
+V Red
GND Black
DI Green
DI Green
DO Orange
+8 ~ 15V Red
GND Black
M2

-11-
SY120SA SINGLE DOOR CONTROLLER
Reader Power
and
Reader Network
DI 1 Brown()
DI 2 Orange()
DI 3 Yellow()
DI 4 Green()
GND Black()
M4
M5
M2
M7
NO NC
GND I4 I3 I2 I1
LEDBED1D00V+V
- LOCK +
NO1 C1 Nc1
+5V LED
RS485 LED
+12V LED
LOCK LED
RELAY LED
BATTERY
CR2032
RELAY
Jp1
BEEPER
CPU
M7
M2
LED Orange()
BEEPER Yellow()
D1 White()
+V Red()
GND Black()
D0 Green()
Ex: Door Sensor()
Ex: Push Button()
4R+ Yellow()
NO Orange( )
COM Gray( )
Connect to
RS485 Convert
()
Connect to DC Power
()
GND Black()
4R- Green()
GND Black()
4R+ Yellow()
NO Violet()
4R- Green()
+8 ~ 15V Red()
E-Lock()
+8 ~ 15V Red()
GND Black()
SYRIS New Version
SYRDS1 , SYRDS5
SYRDK5 , SYRDL5
SYRDF5
4R+ 4R- 0V +V
M6
TAMPER SW
D0 White()
D1 Brown()
BEEPER Violet()
LED Green()
Lock + Brown()
Lock- Orange()
NC Green()
M5
M4
M6
NO NC
Jp1 E-Lock Setting
FAIL - SECURE
()
FAIL - SAFE
()
NO NC
RELAY()!
POWER & RS485
()"#$
M9
TAMPER SW
()%&'(
M9
COM Blue())
16.SY120SA and SYRDK5 Wiring Diagram