SystemBase Portbase PB-3010 User manual

PB-3010/3020+
User Guide
English Ver 1.1
2006. 6. 25
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
1/45

Portbase User Guide
Revision History
Document
Revision Date
Pages
Description
Version
June 5, 2006 1.0 All Initial release by tsum
June 20, 2006 1.1 All Context amendment by shlee
Copyright 2006 SystemBase Co., Ltd.All rights reserved.
Website http://www.sysbas.com/
Tel 02-855-0501
Fax 02-855-0580
16th Fl. Daerung Post Tower-1, 212-8, Guro-dong, Guro-gu, Seoul, Korea
2
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
2/45

Portbase User Guide
Contents
Chapter 1 Introduction 5
1. About This Document 5
2. Who Should Read This Document? 5
3. Document Structure 6
4. Portbase Documents 7
5. Technical Supports 8
Chapter 2 Getting Started 9
1. Overview 9
2. Features 9
3. Package Checklist 10
4. Applications 11
Chapter 3 Hardware Description 12
1. The Exterior 12
2. LED / RESET 14
3. Serial Port Pin Specifications 15
Chapter 4 Installation 16
1. Installing Portbase 16
2. Portbase Connection 17
Chapter 5 Configuration via Web 20
1. Connection 20
2. Setup Menu 21
3. Network Settings 22
3
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
3/45

Portbase User Guide
4. Serial Settings 25
5. Admin Settings 30
6. Change Password 31
7. Update Firmware 32
8. Factory Default 33
9. Save & Reboot 34
Chapter 6 Configuration via Telnet 35
1. Connection 35
2. View commands 36
3. Network commands 36
4. Serial commands 37
5. Admin commands 41
6. System commands 41
Chapter 7 Appendix 42
1. Troubleshooting 42
2. Technical Specifications 44
3. approvals 45
4
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
4/45

Portbase User Guide
Chapter 1 Introduction
This chapter is an introduction to SystemBase device server Portbase series and this document.
1. About This Document
This guide is designed for users of Portbase, who are in charge of connecting to and communicating with
Portbase, setting Portbase’s configurations, status monitoring, firmware update, and other administration
work.
2. Who Should Read This Document?
This guide is designed for Portbase users and administrators. It is strongly recommended that anyone
trying to apply, use, and maintain Portbase read this document. This guide deals with the hardware-level
integration issues and software-level configuration tips. It will be a great starting point for any
administrators who want to easily monitor and control Portbase and its connected devices.
5
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
5/45

Portbase User Guide
3. Document Structure
Introduction (Chapter 1) is a preface with general information and introductory notices.
Getting Started (Chapter 2) gives a brief introduction to Portbase series, including features and
applications.
Hardware Descriptions (Chapter 3) explains about the layout and pin specifications with block diagram
and drawings.
Installation (Chapter 4) helps you to connect Portbase to serial and network environment. It ends up with
first time boot-up and status check.
Configuration via Web (Chapter 5) provides menu-by-menu guide for setting up the operation
environment for Portbase via web browser.
Configuration via Telnet (Chapter 6) provides a list of commands for setting up the operation
environment for Portbase via Telnet.
Appendix (Chapter 7) provides firmware update guides and technical specifications for detailed
information.
6
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
6/45

Portbase User Guide
4. Portbase Documents
The following table summarizes documents included in the Portbase document set.
Document Name Description
Integration, configuration, and
management tasks are explained for the
administrator
User Guide
Guide for SystemBase device server
management application Portview
Portview User Manual
COM Port Redirector
User Manual Guide for SystemBase COM Port Redirector
If you need brief information on Portbase or device servers in general, please visit our company website
at http://www.sysbas.com/. You can view and/or download documents related to Portbase as well as latest
software and firmware updates. Available resources are as follows:
Document Name Description
Portbase Spec Sheet Specifications for Portbase products
A
n easy reading for anyone new to device
server.
Deals with background and technology
Past, present, and future of device
servers along with the overview of
market environment
Portbase White Paper
All documents are updated promptly, so check for the recent document update. The contents in these
documents are subject to change without any notice in advance.
7
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
7/45

Portbase User Guide
5. Technical Supports
There are three ways you can get a technical support from SystemBase.
First, visit our website http://www.sysbas.com/ and go to ‘Technical Support’ menu. There you can read
FAQ and ask your own question as well.
Second, you can e-mail our technical support team. The mail address is [email protected]om. Any kind of
inquiries, requests, and comments are welcome.
Finally, you can call us at the customer center for immediate support. Our technical support team will
kindly help you get over with the problem. The number to call is 82-2-855-0501 (Extension number 225).
Do not forget to dial the extension number after getting a welcome message.
8
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
8/45

Portbase User Guide
Chapter 2 Getting Started
This chapter includes Portbase overview, main and distinctive features, package contents for each product,
and application fields.
1. Overview
Portbase provides network connectivity to various serial devices (security devices, communication
peripherals, modems, data printing devices, industrial metering devices, etc.). Portbase supports RS232,
RS422, and RS485 serial communication standards under various communication speed, meanwhile auto-
sensing 100baseTX Fast Ethernet and 10baseT Ethernet connection.
2. Features
Various features of Portbase make it a universal yet distinctive device server solution. Here we present
main features of Portbase. Others will explicitly appear throughout this guide.
-Max 921.6Kbps serial speed
-Software configurable RS232/422/485 interfaces
-10/100Mbps Ethernet port
-SystemBase COM Port Redirector for better adaptability
-Extensive configuration and monitoring with Portview
-Firmware upload with Web and FTP
-Configuration with Web, Telnet, SNMP, and Portview
-Lots of customizing options
9
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
9/45

Portbase User Guide
3. Package Checklist
Portbase package is composed of following components. Make sure every component is included with
your package.
All packages include a module and a CD with utilities and documents.
Portbase device
Cross LAN Cable 1pc
Power Adapter 1pc
CD (utilities and documentations)
A-Class Device
This device is registered only for office use, and both the seller and the user must be aware of
this. If not correctly sold or purchased, please exchange with home use device.
10
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
10/45

Portbase User Guide
4. Applications
Portbase can be applied to many practical applications in various fields. Here we present some of them.
Factory / Industrial Automation
PLC, Robot arms, Human-Machine Interface, Warehouse rails
Medical instruments, Inspection equipment controllers
Alarming units
Home Appliances / Electronic Devices
Power controller, Gaming machines
Scales, Gas detection units, Water & pollution metering devices
Data collection and distribution units
Financial / Building Automation
Card readers, Barcode scanners, Kiosks, Point-Of-Sale related devices
Serial printers, Cash registers, Credit card authorization terminals
Biometric detection units, Security devices
11
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
11/45

Portbase User Guide
Chapter 3 Hardware Description
This chapter provides Portbase's hardware information, including block diagram, layout, pin
specifications, dimensions and other hardware-related issues.
1. The Exterior
<fullview> <topview>
< side view >
12
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
12/45

Portbase User Guide
<PB-3020+serialportside> <PB-3010+serialportside>
Serial port – 8-pin RJ-45 jack which shows user-selected interface
(RS232/RS422/RS485) on LED
<LANportside>
Power connector – for connection of DC5V adapter cable
Terminal block power connector – for connection of terminal block power cable
Reset button – Portbase reboots if this button is pressed for less than 5 seconds. If
pressed for longer than 5 seconds, Portbase will restore factory default settings.
LED – Operation status of Portbase. Next section describes the meaning of each LED
display status.
LAN port – 8-pin RJ45 jack which is used when connecting Portbase to network
devices such as Ethernet card, hub, and router.
13
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
13/45

Portbase User Guide
2. LED / RESET
<LED display status>
LED Status Meaning
On Power supplied to the device
PWR
(RED) Off No power supplied to the device
Off No active network connection
LAN
(Green) On Network activated
Blinking IP Configuration
On Normal operation
RDY
(Green) Off System error
RS232 On
Serial port set to RS232 mode
RS422 On
Serial port set to RS422 mode
RS485 On
Serial port set to RS485 mode
Green Blinking Serial data transmitted
Serial Tx/Rx Orange Blinking Serial data received
Green Blinking 10baseT connection detected & LAN data transferred
LAN Tx/Rx Orange Blinking 100baseT connection detected & LAN data transferred
<Reset button features>
Operation Result
Pressed for less than 5 seconds Restart Portbase
Pressed for more than 5
seconds Restore factory default settings of Portbase. The device will
automatically reboot.
14
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
14/45

Portbase User Guide
3. Serial Port Pin Specifications
- RS232 - RS422 - RS485
Pin Specifications
1 RTS RS232 Signal (RequestTo Send)
2 DTR RS232 Signal (Data Terminal Ready)
3 RXD RS232 Signal (Receive Data)
4 DSR RS232 Signal (Data Set Ready)
5 TXD RS232 Signal (Transmit Data)
6 GND RS232 Signal (Signal Ground)
7 DCD RS232 Signal (Data Carrier Detect)
8 CTS RS232 Signal (Clear To Send)
RX+ RS422 Signal (Receive Data +)
TX+ RS422 Signal (Transmit Data +)
TX- RS422 Signal (Transmit Data -)
RX- RS422 Signal (Receive Data -)
TRX+ RS485 Signal (Transmit/Receive Data +)
TRX- RS485 Signal (Transmit/Receive Data -)
1 RTS 2 DTR
3 RXD 4 DSR
5 TXD 6 GND
7 DCD 8 CTS
1TX- 2
3 RX+ 4 RX-
5TX+ 6GND
78
1TRx- 2
3 4
5TRx+ 6 GND
7 8
15
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
15/45

Portbase User Guide
Chapter 4 Installation
This chapter explains how you can make Portbase to communicate. It deals with LAN and serial
connection guides for Portbase to operate together with the target serial device.
1. Installing Portbase
Follow the steps below to install Portbase. In most cases, Portbase’s factory default settings should be
sufficient for most serial connections; however, some of the configuration settings may have to be
changed for your particular installation. Portbase can be wall mounted, set on the desktop, or mounted
using the optional DIN rail kit.
1. Before attempting to install Portbase, make sure you have installed and set up your serial equipment as
described in the documentation that came with the device.
2. Write down the 12-digit MAC (Media Access Code) address printed on the label located on the bottom
of Portbase. You may need this number in order to configure Portbase.
3. Connect Portbase to your equipment using an RJ-45 serial connector.
4. Plug Portbase power supply adapter into a suitable AC receptacle, and then plug the power supply
cable into Portbase. Portbase will run through a sequence of power-up diagnostics for a few seconds.
If Portbase is operating properly, the RDY LED will blink constantly in a regular
pattern. PWR LED should also be on.
If the RDY LED does not blink continuously in a regular pattern, a problem exists. If
this is the case, try powering the unit OFF and then ON again. If the problem persists,
refer to the Troubleshooting section in this User Guide.
5. Connect Portbase to your network through a switch or hub using a category 5 (CAT5) Ethernet cable.
Portbase’s IP address must be configured before a network connection is available. If your network
offers DHCP (Dynamic Host Configuration Protocol), Portbase will automatically search for a DHCP
server upon power up and obtain an IP address. If your network does not offer DHCP, a static
(fixed) IP address must be assigned (see your system administrator for assistance). In most cases, a
fixed IP address is preferred because a DHCP server may not always assign the same IP address to
Portbase when Portbase is powered ON.
16
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
16/45

Portbase User Guide
NOTE: The IP address must be within a valid range, unique to your network, and in the same subnet as your
PC.
2. Portbase Connection
Follow these steps to connect Portbase to the device and network.
Connection Guide
1) LAN
In order to connect Portbase to network, you need to use RJ45 Ethernet port. It supports both 10Mbps and
100Mbps Ethernet connection (auto-sensing). Plug one end of a LAN cable to Portbase and the other end
to a hub, switch, or any other network device that can provide you with network access.
* If you connect portbase to PC directly, you have to use cross LAN cable.
2) Serial
In order to connect external serial device and Portbase, RJ45 serial cable is required. For pin
specifications and further information, please refer to the Chapter 3. Hardware Descriptions.
First-Time Bootup
Portbase will power on and start booting process when DC adapter (5V) is connected. Operation status
can be monitored by LED displays. For more information on LED displays, please refer to the Chapter 3.
Hardware Descriptions.
An IP address is required to access Portbase's web interface or telnet command-line configuration tool.
By factory default, Portbase is assigned a static IP address. After the initial connection, you can either
manually assign a different IP address or set Portbase to automatically get an IP address from a DHCP
server.
The factory default IP address of Portbase : 192.168.1.71(10.10.1.1)
17
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
17/45

Portbase User Guide
Portbase’s default IP address is set to 10.10.1.1. In order to connect with this address, you need to change
network configurations so that your PC can connect to the IP 10.10.1.1. Please refer to an example below,
and note that values doesn’t necessarily have to be identical to the example below.
After modifying the IP address of Portbase, it may lead to difficulties if you do not remember the IP
address. To prevent such accidents, Portbase always remembers a factory default address 10.10.1.1
18
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
18/45

Portbase User Guide
Now you are ready to connect to Portbase! There are three options to configure Portbase.
Web: You can easily configure Portbase with web interface, accessible from any web browser. For more
information, please refer to Chapter 5. Configuration via Web.
Telnet: You can configure Portbase with commands after accessing Portbase through Telnet. For more
information, please refer to Chapter 6. Configuration via Telnet.
19
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
19/45

Portbase User Guide
Chapter 5 Configuration via Web
1. Connection
Open your favorite web browser and enter the IP address of Portbase to access Portbase’s web manager.
Once you are successfully connected, the following front page will show up. You need to enter
appropriate username and password to login.
Please note that this username and password is used as authentication method for Telnet as well. This
means if username or/and password has been modified from the web interface, modified values have to be
entered to connect to Telnet, and vice versa.
Factory default username: portbase
Factory default password: 99999999
20
ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
20/45
This manual suits for next models
1
Table of contents
Other SystemBase Server manuals