Systems With Intelligence DVS500 User manual

© 2018 Systems With Intelligence. All rights reserved.
DVS500
INSTALLATION GUIDE
Version 1.0
SUBSTATION HARDENED DIGITAL VIDEO SERVER
Note: Please read this manual thoroughly before operating this unit and retain it for future reference.

INSTALLATION
DVS500 Installation Guide - V1.0
2www.SystemsWithIntelligence.com support SystemsWithIntelligence.com
© 2018 Systems With Intelligence. All rights reserved.
Copyright
COPYRIGHT © 2017 Systems With Intelligence Inc. ALL RIGHTS RESERVED
Dissemination or reproduction of this document, or evaluation and communication of its contents, is
not authorized except where expressly permitted. Violations are liable for damages. All rights reserved,
particularly for the purposes of patent application or trademark registration.
This document contains proprietary information, which is protected by copyright. All rights are reserved.
No part of this document may be photocopied, reproduced or translated to another language without
the prior written consent of Systems With Intelligence Inc.
Disclaimer of Liability
We have checked the contents of this manual against the hardware and software described. However,
deviations from the description cannot be completely ruled out.
Systems With Intelligence shall not be liable for any errors or omissions contained herein or for
consequential damages in connection with the furnishing, performance, or use of this material.
The information given in this document is reviewed regularly and any necessary corrections will be
included in subsequent editions. We appreciate any suggested improvements. We reserve the right to
make technical improvements without notice.
Contacting Systems With Intelligence
6889 Rexwood Road, Unit #9, Mississauga, Ontario, L4V 1R2 Canada
Phone: +1-289-562-0126 Email: info@SystemsWithIntelligence.com
www.SystemsWithIntelligence.com
Technical Support
International +1-289-562-0126 Fax: +1-289-562-0152
Email: support @SystemsWithIntelligence.com

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support SystemsWithIntelligence.com
© 2018 Systems With Intelligence. All rights reserved.
3
INSTALLATION
Federal Communications Commission
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference on his own expense.
CAUTION
This product contains a laser system and is classied as a
“CLASS 1 LASER PRODUCT”
CAUTION
Use of controls or adjustments or performance of procedures other than those specied herein may result
in hazardous radiation exposure. This product contains no user-serviceable parts. Attempted service by
unauthorized personnel shall render all warranties null and void.
Changes or modications not expressly approved by Systems With Intelligence Inc. could void the user’s
authority to operate the equipment.
Should this device require service please contact Systems With Intelligence Inc.
IMPORTANT
The DVS500 family of products should be installed in a restricted access location where access can only
be gained by service personnel or users who have been instructed about the reasons for the restrictions
applied to the location and about any precautions that shall be taken; and access is through the use of
a tool or lock and key, or other means of security, and is controlled by the authority responsible for the
location.

INSTALLATION
DVS500 Installation Guide - V1.0
4www.SystemsWithIntelligence.com support SystemsWithIntelligence.com
© 2018 Systems With Intelligence. All rights reserved.
Table of Contents
Federal Communications Commission Radio Frequency Interference Statement.....................................3
TableofContents..................................................................................................................................................4
1: Product Overview ..............................................................................................................................................5
1.1 From & Rear Diagram ..................................................................................................................................................5
1.2 Technical Specications Overview............................................. .............................................................................6
2: Dimensions ....................................................................................................................................................... 7
3: Power Supply .................................................................................................................................................. 8
3.1 Power Supply Wiring................................................................................................................................................. 9
3.2 Dual Redundant Power Supply.............................................................................................................................. 9
4: Failsafe Relay ............................................................................................................................................... 10
5: IP Camera Input .............................................................................................................................................. 11
6: Serial Interface .............................................................................................................................................. 12
6.1 Dry Contact Input Interface Connector .............................................................................................................. 12
6.2 Relay Output Interface Connectors...................................................................................................................... 13
7: Ethernet Ports................................................................................................................................................ 14
7.1 Copper Ports........................................................................................................................................................... 14
7.2 Copper Gigabit Ethernet 1000Base-TX Cabling Recommendations................................................................. 14
8: Environmental Specications....................................................................................................................... 15
8.1 Temperature & Humidity....................................................................................................................................... 15
8.2 EMC/EMI/ESD......................................................................................................................................................... 15
EMI TYPE TESTS ............................................................................................................................................ 16
EMI IMMUNITY TYPE TESTS ......................................................................................................................... 17

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
5
INSTALLATION
1 Product Overview
1.1 Front & Rear Diagram
Dimensions (HxWxD):
•6.34in (161mm) x 3.72in
(94.5mm) x 5.44in (138.2mm)
HDMI
•HDMI Interface
USB
•2 x USB 2.0 Ports
Digital Inputs
•4 x Digital Inputs
Digital Outputs
• 4 x Digital Outputs
Mounting
•DIN rail mounts
Substation Hardened
•IEC 61850-3, IEEE 1613, C37.90
•-400C to +750C
*Future option available soon.
3.72 in.
94.5 mm
6.34 in.
161 mm
Ethernet
•2 x 10/100/1000 BaseTX
Ethernet Ports
Ethernet Ports
•Ethernet Ports for IP Camera
Support
Wide Area Network
•10/100/1000 BaseFX
Ethernet Port
•WiFi Interface*
•Cellular Interface*
FAIL SAFE
•Fail Safe Relay
5.44 in.
138.2 mm
Redundant Power Input
•20VDC-60VDC

INSTALLATION
DVS500 Installation Guide - V1.0
6www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
1.2 Technical Specications Overview
SPECIFICATIONS
IP Cameras
• Up to 4 IP cameras can be connected to the DVS
• IP Camera support for leading manufacturers (Contact Systems With Intelligence for
the latest list of supported IP Cameras)
• H.264videostreaming
• Resolution and frame rate dependant on IP camera used
• HD and megapixel images supported
• ONVIF IP Camera Support
CPU • Atom E3845, 1.91GHz**
RAM • 4GB DDR3L**
Power • 30W Max.
Video Output • 1 HDMI interface for computer monitor
USB • 2 USB 2.0 Ports
Storage • Up to 1TB
LAN Interface • Included: 2-port 10/100/1000TX RJ45 Interface
• Optional: 4-ports 10/100TX RJ45 or 100FX Fiber Interface
Optional Modules • Ethernet: 1-port 1000FX Fiber Interface
• Wireless: 802.11 b/g*, Cellular Modem*
Power Supply • 20VDC - 60VDC
Operating Temperature • -40˚Cto+75˚C;nocoolingfans
EMC/EMI • IEC61850-3;IEEE1613;IEC61000-6-2;IEC61800-3
Mounting/Dimensions • DIN mountable
Warranty • 2 Years
* Future option available soon.
** Other CPU models and RAM are available. Please contact Systems with Intelligence for more information.

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
7
INSTALLATION
2 Dimensions
* Note: Units in Imperial (Metric).
3.72 in
(94.5 mm)
6.34 in
(161 mm)
2.94 in
(74.8 mm)
5.44 in
(138.2 mm)

INSTALLATION
DVS500 Installation Guide - V1.0
8www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
3 Power Supply
POWER SUPPLY
TYPE
INPUT RANGE INTERNAL
FUSE
RATING
POWER CONSUMPTION
MIN MAX TYPICAL WORST CASE
24/48 VDC 20 VDC 60 VDC 5A(T) 15 W - 20 W 25 W - 30 W
TERMINAL
NUMBER DESCRIPTION USAGE
Screw
Chassis
Ground Chassis Ground is connected to the equipment ground bus.
+Positive / + Positive / + is connected to the positive (+) terminal.
-Negative / - Negative / - is connected to the negative (-) terminal.
DVS500 OVERALL DIMENSION
DVS500 OVERALL DIMENSION

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
9
INSTALLATION
3.1 Power Supply Wiring
Notes:
• Equipment must be installed according to
the applicable country wiring codes.
• Connect the ground terminal on the
power source to the chassis ground
terminal on the DVS500
3.2 Dual Redundant Power Supply Wiring
Notes:
• Equipment must be installed according to
the applicable country wiring codes.
• AConnect the ground terminal on the
power source to the chassis ground
terminal on the DVS500.

INSTALLATION
DVS500 Installation Guide - V1.0
10 www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
4 Failsafe Relay
The failsafe relay is a digital output contact that can be used to communicate an alarm to another system
(e.g. remote terminal unit) if the server stops working. The failsafe relay is in open state (normally open)
when the server is powered down, and it is latched by the system when the server is powered up. An open
state will indicate that the server has no power or that something is wrong with the software running in the
server.
DVS500 OVERALL DIMENSION

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
11
INSTALLATION
5 IP Camera Input
The DVS500 can be equipped with IP video inputs. 4-port IP Camera Input cards are available with ber
optic SFP based LC connectors or RJ45 connectors. All ports support 100Mbps inputs.
4-Channel Camera Input card with RJ45 Interface
4-Channel Camera Input card wit SFP based LC ber optic interface
Partial view of the Camera Input card of the DVS500
DVS500 OVERALL DIMENSION
DVS500 OVERALL DIMENSION

INSTALLATION
DVS500 Installation Guide - V1.0
12 www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
6 Serial Interface
The DVS500 is equipped with a module that provides 4 digital inputs and 4 digital outputs with the following
characteristics:
• 4 dry contact, current loop inputs + 4 relay switch output (30 VDC, 1 Amp / 50 VAC, 5 Amps)
6.1 Dry Contact Input Interface Connector
Connector Part Number: 1727570000
Manufacturer: Weidmüller
Description: Conn Term Block, 3.5mm pitch, 8POS SN OR
DVS500 OVERALL DIMENSION
PIN SIGNAL TYPE CONNECTION
1EXT_DRYCON1 I Dry contact input signal
2GND P Signal Ground
3EXT_DRYCON2 I Dry contact input signal
4GND P Signal Ground
5EXT_DRYCON3 I Dry contact input signal
6GND P Signal Ground
7EXT_DRYCON4 I Dry contact input signal
8GND P Signal Ground
Table 1 - Dry Contact Input Interface Connector Pin Denition (P2)

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
13
INSTALLATION
DVS500 OVERALL DIMENSION
PIN SIGNAL TYPE CONNECTION
1NO_RELAY1 O Normally open relay output
2COM_RELAY1 O Common relay output
3NO_RELAY2 O Normally open relay output
4COM_RELAY2 O Common relay output
5NO_RELAY3 O Normally open relay output
6COM_RELAY3 O Common relay output
7NO_RELAY4 O Normally open relay output
8COM_RELAY4 O Common relay output
Table 2 - Relay Interface Connector Pin Denition (P2)
6.2 Relay Output Interface Connectors
Connector Part Number: 1827761
Manufacturer: Phoenix
Description: Header, RA, 3.81mm pitch, Locking screws
PIN SIGNAL TYPE CONNECTION
1EXT_DRYCON1 I Dry contact input signal
2GND P Signal Ground
3EXT_DRYCON2 I Dry contact input signal
4GND P Signal Ground
5EXT_DRYCON3 I Dry contact input signal
6GND P Signal Ground
7EXT_DRYCON4 I Dry contact input signal
8GND P Signal Ground

INSTALLATION
DVS500 Installation Guide - V1.0
14 www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
7 Ethernet Ports
7.1 Copper Ports
The DVS500 has an IEEE 802.3 Ethernet Interface for 1000Base-T, 100Base-TX, and 10Base-T applications
(802.3, 802.3u, and 802.3ab) conformance. The RJ45 Ethernet ports features auto negotiating, and auto-
crossover functions. The following gure shows the RJ45 port pins conguration.
7.2 Copper Gigabit Ethernet 1000Base-TX Cabling Recommendations
The IEEE 802.3ab Gigabit Ethernet standard denes 1000 Mbits/s Ethernet communications over
distances of up to 100 meters using 4 pairs of category 5 (or higher) balanced unshielded twisted-pair
cabling. For wiring guidelines, system designers and integrators should refer to the Telecommunications
Industry Association (TIA) TIA/EIA-568-A wiring standard that characterizes minimum cabling performance
specications required for proper Gigabit Ethernet operation. To ensure reliable, error-free data
communications, new and pre-existing communication paths should be veried for TIA/EIA-568-A
compliance.
In general the following recommendations should be followed for copper data in high electrical noise
environments:
• Data cable lengths should be as short as possible, ideally limited to 3m (10ft) in length. Copper
data cables should not be used for inter-building communications.
• Power and data cables should not be run in paraellel for long distances, and ideally should be
installed in separate conduits. Power and data cables intersect at 900 angles when necessary to
reduce inductive coupling.
• Shield/screened cabling can optionally be used. The cable shield should be grounded at one
single point to avoid the generation of ground loops.
PIN SIGNAL 10/100 TX SIGNAL 1000TX
1+Rx BI_DA+
2- Rx BI_DA-
3+Tx BI_DB+
4No Connection BI_DB-
5No Connection BI_DC+
6-Tx BI_DC-
7No Connection BI_DD+
8No Connection BI_DA-
DVS500 OVERALL DIMENSION

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
15
INSTALLATION
8 Environmental Specications
This section summarizes the environmental specications that the DVS500 has been designed to meet.
8.1 Temperature & Humidity
8.2 EMC/EMI/ESD
1. IEC 61850-3 Electric Utility Substations
2. IEEE 1613 Electric Utility Substations
3. IEC 61000-6-2 Industrial (Generic)
4. CISPR FCC Part 15 Class A (Conducted and Radiated Emission)
FUNCTION DESCRIPTION SPECIFICATION
IEC 60870-2-2
Cold Operation - 40°C, 16 hours
Dry Heat Operation +75°C, 16 hours
Cold Storage - 40°C, 16 hours
Dry Heat Storage +85°C, 16 hours
Damp Heat Test +95%, +40°C, 96 hours

INSTALLATION
DVS500 Installation Guide - V1.0
16 www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
EMI TYPE TESTS
TEST DESCRIPTION TEST LEVELS
IEC 61000-4-2 ESD Enclosure Contact +/- 8KV
Enclosure Air +/- 15KV
IEC 61000-4-3 Radiated
RFI Enclosure ports 20 V/m
IEC 61000-4-4 Burst (Fast
Transient)
Signal ports +/- 4KV @ 5KHz, 1 min
D.C. Power ports +/- 4KV @ 5KHz, 1 min
Earth ground ports +/- 4KV @ 5KHz, 1 min
IEC 61000-4-5 Surge
Signal ports +/- 1KV line-to-line
D.C. Power ports +/- 2KV line-to-earth
+/- 1KV line-to-line
IEC 61000-4-6
Induced
(Conducted
RFI)
Signal Ports 10V 10V
D.C. Power ports 10V
Earth ground ports 10V
IEC 61000-4-8 Magnetic
Field Enclosure ports 100 A/m continuous, 1000 A/m for 1s
IEC 61000-4-29 Voltage Dips
& Interrupts D.C. Power ports
18 VDC-30%
18 VDC-60%
18 VDC-100%
18 VDC+/-20%
60 VDC-30%
60 VDC-60%
60 VDC-100%
60 VDC+/-20%
IEC 61000-4-16
Main
Frequency
Voltage
Enclosure ports 20 V/m
IEC 61000-4-17
Ripple on
D.C. Power
Supply
D.C. Power ports 15% of rated voltage
IEC 60255-5 Dieletric
Strength
Signal ports
705 VDC, 1 min (Ethernet)
705 VDC, 1 min (Relay)
705 VDC, 1 min (Relay Contacts)
D.C. Power ports 705 VDC
IEC 60255-5 H.V. Impulse D.C. Power ports 5KV

DVS500 Installation Guide - V1.0
www.SystemsWithIntelligence.com support@SystemsWithIntelligence.com
© 2017 Systems With Intelligence. All rights reserved.
17
INSTALLATION
EMI IMMUNITY TYPE TESTS
IEEE 1613 (C37.90.x) EMI IMMUNITYPE TESTS
TEST DESCRIPTION TEST LEVELS
IEEE C37.90.3 ESD Enclosure Contact +/- 2KV, +/- 4KV, +/- 8KV
Enclosure Air +/- 4KV, +/- 8KV, +/- 15KV
IEEE C37.90.2 Radiated
RFI Enclosure ports 20 V/m
IEEE C37.90.1 Fast
Transient
Signal ports +/- 4KV @ 2.5KHz
D.C. Power ports +/- 4KV
Earth ground ports +/- 4KV
IEEE C37.90 Dieletric
Strength
Signal ports 705 VDC, 1 min
D.C. Power ports 705 VDC, 1 min
IEEE C37.90 H.V. Impulse D.C. Power ports 5KV

Systems With Intelligence Inc.
6889 Rexwood Road, Unit #9
Mississauga, Ontario, CANADA
L4V 1R2
Tel: +1-289-562-0126
Fax: +1-289-562-0152
General Inquiries:
info@SystemsWithIntelligence.com
Sales Inquiries:
sales@SystemsWithIntelligence.com
Product Support:
support@SystemsWithIntelligence.com
All specifications in this document are subject to change without notice.
© Copyright 2018 Systems With Intelligence Incorporated. All rights reserved.
Version 1.0
DVS500
INSTALLATION GUIDE
d017-0003-301-1
Table of contents
Popular Server manuals by other brands

VVDN Technologies
VVDN Technologies DT4CS User's manual guide

IBM
IBM Flex System x440 Compute Node Installation and service guide

Bull
Bull NovaScale R422-INF-E1 Installation and user guide

Bull
Bull NovaScale 4020 user guide

Envivio
Envivio 4Sight Administrator's guide

Lenovo
Lenovo THINKSERVER RS210 warranty and support information

Compaq
Compaq 108164-003 - ProLiant - 800 Integration notes