Tamarack Solar TTP-A-2 User manual

Installaon Manual Pole Mount
TTP-A Series
1support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Installation Manual
Models: TTP-A-2 / TTP-A-3 / TTP-A-4 / TTP-A-4HW / TTP-A-6 / TTP-A-6HW
TTP-A-MAN v2
Note: 2-inch horizontal steel pipes shown in the pictures above are not included. Purchase locally or from us.
TTP-A-2 2 Module Top of Pole Mount
TTP-A-3 3 Module Top of Pole Mount
TTP-A-4 4 Module Top of Pole Mount
TTP-A-4HW 4 Module Top of Pole Mount, High Wind
TTP-A-6 6 Module Top of Pole Mount
TTP-A-6HW 6 Module Top of Pole Mount, High Wind

2
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Scan the QR Code below to see an animated video of the assembly of this mount.
Technical Support: 707-234-8107 or 800-819-7236 Ext 556
Use these torque sengs when assembling your TTP-A mount.
If you are using an-seize compound on bolts, reduce torque by 15%.
Bolt Description Bolt Size Socket Size Foot-Lbs
Cap Bolts 3/4-inch 1-1/8 inch 100
Cap Set Screws 1/2-inch 1/2-inch 8pt 40
U-Bolt on Adjuster 3/8-inch 9/16-inch 12
Hex Bolt on Adjuster 1/2-inch 3/4-inch 40
H-Frame Bolts 1/2-inch 3/4-inch 45
U-Bolts Pipe to H-Frame 3/8-inch 9/16-inch 15
U-Bolts on Pipe Mounts 5/16-inch 1/2-inch 6
Rail Splice Bolts 5/16-inch 1/2-inch 12
Pipe Mounts on rails 5/16-inch 1/2-inch 12
5050 Mid Clamps on Modules 5/16-inch 1/2-inch 12
5050 Clamps as End Clamps 5/16-inch 1/2-inch 9
TTP-A Torque Settings

Installaon Manual Pole Mount
TTP-A Series
3support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Disclaimer
This manual describes proper installaon procedures and provides necessary standards required for product
reliability. Warranty details are available on our website. www.tamaracksolar.com
All installers must thoroughly read this manual and have a clear understanding of the installaon procedures
prior to installaon. Failure to follow these guidelines may result in property damage, bodily injury or even
death.
Structural parts of this mount are made with painted steel which will show signs of rust in areas that get
scratched during assembly. It is good pracce to repaint scratched parts aer assembly.
Installer Responsibilies
• Follow all applicable local or naonal building and re codes, including any that may supersede this
manual.
• Electrical installaon should be conducted by a licensed and bonded electrician or solar contractor.
• Module maintenance or removal must not break the bonding path of the system.
• Ensure all products used are appropriate for the installaon and array under the site’s loading condions.
• Use only Tamarack parts or parts approved by Tamarack; substung parts may void any applicable
warranty.
• Comply with all applicable re codes including, but not limited to, keeping walkways clear.
• Ensure bare copper grounding wire does not contact aluminum and zinc-plated steel components, to
prevent risk of galvanic corrosion.
• If loose components or loose fasteners are found during periodic inspecon, reghten immediately. If
corrosion is found, replace aected components immediately.
• Provide an appropriate method of direct-to-earth grounding according to the latest edion of the Naonal
Electrical Code, including NEC 250: Grounding and Bonding, NEC 690: Solar Photovoltaic Systems, and CSA
C22.1, Safety Standard for Electrical Installaons, Canadian Electrical Code, Part 1
• Disconnect AC power before servicing or removing microinverters and power opmizers.
• Review module manufacturer’s documentaon to ensure compability and compliance with warranty
terms and condions.
• Maximum Series Fuse Rang is 20 Amps.
Tools Required
• 1 1/8-inch Socket
• 1-1/8-inch Wrench
• 3/4-inch Socket
• 9/16-inch Socket
• 1/2-inch Socket
• Ratchet to t Sockets
• Crescent Wrench
• Torque Wrenches (sengs range from 6 to
100 foot-pounds. This may require mulple
wrenches)
• Tape Measure
• Angle Finder
• Compass
• Ladder

4
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
TTP-A Series Pole Mount Components
Part Description TTP-A-2 TTP-A-3 TTP-A-4 TTP-A-4HW TTP-A-6 TTP-A-6HW
Pole Cap, Pivot 4-inch pipe, 2.5-inch holes 1 1
Pole Cap 4-inch Backplate 1 1
Array Tilt Adjuster Arm 1 1
Pole Top Cover 4-inch 1 1
Pole Cap Bolts 3/4 -10 x 7-inch 1 1
Pole Cap Top Support Bolt 3/4-10 x 6-inch 1 1
Pole Cap FlangeNut 3/4-10 1 1
Set Bolts 1/2 -13 x 1-1/2inch 1 1
Hex Bolt 1/2-13 x 1-1/2-inch for Adjuster 1 1
Flange Nut ½ - 13 for Adjuster 1 1
Adjuster U-Bolt ⅜” x 2-1/2-inch 1 1
Pole Cap, Pivot 6-inch pipe, 2.5-inch holes 1 1 1 1
Pole Cap 6-inch Backplate 1 1 1 1
Array Tilt Adjuster Arm 1 1 1 1
Pole Top Cover 6-inch 1 1 1 1
Pole Cap Bolts 3/4 -10 x 9-inch 2 2 2 2
Pole Cap Top Support Bolt 3/4-10 x 8-inch 1 1 1 1
Pole Cap FlangeNut 3/4-10 3 3 3 3
Set Bolts 1/2 -13 x 1-1/2inch 6 6 6 6
Hex Bolt 1/2-13 x 1-1/2-inch for Adjuster 1 1 1 1
Flange Nut ½ - 13 for Adjuster 1 1 1 1
Adjuster U-Bolt ⅜” x 3-1/8-inch 1 1 1 1
Rectangular Tube 3x2 x 0.12 wall 1 1 2 2
Rectangular Tube 3x2 x 0.188 wall 2 2
Suport Pipe 2-inch Sch 40 1 1 1 1
Suport Pipe 2-inch Sch 80 1 1
Pivot Pipe 2.5-inch Sch 40 1 1
2
1
Pivot Pipe 2.5-inch Sch 80 1 1
Hex Bolt 1/2-13 x 3-1/2-inch 1 1 4 4 4 4
Flat Washer 1/2-inch 1 1 4 4 4 4
U-Bolt w/Nuts for 2-inch Pipe 1 1 8 8 8 8
3.1 Rail 85-inch
4
4
3.1 Rail 66-inch 8 8
Module Rail Splice with Bolts and Nuts 4 4
Module Mounting Clamp 68121216 16
Pipe Mount w/U-Bolt 448 8 8 8
Module Rail End Caps 448 8 8 8
Ground Lug 112 2 2 2
Module Lead Clips 669 9 9 9
Cap Assembly - 4-inchCap Assembly - 6-inchH-FrameModule Mounting Rails
2
4
2

Installaon Manual Pole Mount
TTP-A Series
5support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Foundaon Hole and Pole Guidelines
• The suggesons below are recommendaons only. It
is the installer’s responsibility to validate foundaon
parameters prior to installaon; a local geotechnical
report may be required to assess soil condions. We
recommend consulng with a local engineer familiar
with local regulaons and build site requirements,
including soil condions, terrain, and load criteria
(wind, snow, seismic). All of these parameters may
impact foundaon requirements.
• If array angle will be seasonally adjusted, use the
foundaon and pole pipe sizing guidelines for the
planned steepest angle. This insures the pole and
foundaon are strong enough to support the array,
as well as maintaining the desired minimum ground
clearance, at all projected angles.
• Highlighted lines in the tables on the next 2 pages
require schedule 80 pipe for the main support pipe.
• Dig hole according to recommended depth and
diameter. Remove or properly compact any loose
material at the boom of the hole.
• The pole length listed in the following tables are
based on having the pole installed 2-3 inches from
the boom of the dug holes. Use a brick, concrete
block, les, or other non-organic solid material at the boom of the hole to support the pole, raising it above the
boom of the hole and allowing concrete to fully encapsulate the pipe pole. If using a thicker material, be sure to
allow for the added thickness when calculang the above-ground and total pole lengths.
• Set pole in hole and use a level to insure that it is straight and plumb in all direcons.
• Brace pole to prevent movement while pouring concrete. Pour so concrete is in direct contact with the soil. If
forming or using sonotube, properly compact backll. Allow concrete to cure for recommended length of me.
Soil Classicaons
• If in doubt about the soil type and holding strength, consult a local engineer.
• Class 3 - Sandy Gravel and/or Gravel - Lateral Bearing Pressure - 200 lbs/sq below natural grade
• Class 4 - Sand; silty sand, clayey sand, silty gravel, and clayey gravel - Lateral Bearing Pressure - 150 lbs/sq below
natural grade
• Class 5 - Clay, sandy clay, silty clay, silt and sandy silt - Lateral Bearing Pressure - 100 lbs/sq below natural grade

6
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
ArrayTilt
Angle↓
Wind
Speed
(mph)↓
Pipe
Above
Ground
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
100 2.5 6.4 2.1 6.0 2.8 6.7 2.4 6.3 3.3 7.2 2.8 6.7
120 2.9 6.8 2.4 6.3 3.2 7.1 2.7 6.6 3.8 7.7 3.2 7.1
140 3.2 7.1 2.8 6.7 3.6 7.5 3.1 7.0 4.3 8.2 3.6 7.5
100 2.9 7.3 2.5 6.9 3.3 7.7 2.8 7.2 3.8 8.2 3.3 7.7
120 3.4 7.8 2.9 7.3 3.8 8.2 3.2 7.6 4.4 8.8 3.8 8.2
140 3.8 8.2 3.2 7.6 4.3 8.7 3.6 8.0 5.0 9.4 4.3 8.7
100 3.3 8.2 2.8 7.7 3.7 8.6 3.2 8.1 4.3 9.2 3.7 8.6
120 3.8 8.7 3.2 8.1 4.3 9.2 3.6 8.5 5.0 9.9 4.3 9.2
140 4.3 9.2 3.7 8.6 4.8 9.7 4.1 9.0 5.7 10.6 4.8 9.7
100 3.6 8.9 3.1 8.4 4.0 9.3 3.4 8.7 4.7 10.0 4.0 9.3
120 4.1 9.4 3.5 8.8 4.6 9.9 4.0 9.3 5.5 10.8 4.6 9.9
140 4.7 10.0 4.0 9.3 5.2 10.5 4.5 9.8 6.2 11.5 5.2 10.5
100 3.8 9.4 3.3 8.9 4.3 9.9 3.7 9.3 5.0 10.6 4.3 9.9
120 4.4 10.0 3.8 9.4 4.9 10.5 4.2 9.8 5.8 11.4 4.9 10.5
140 5.0 10.6 4.2 9.8 5.6 11.2 4.7 10.3 6.6 12.2 5.6 11.2
ArrayTilt
Angle↓
Wind
Speed
(mph)↓
Pipe
Above
Ground
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
100 2.9 9.8 2.5 9.4 3.3 10.2 2.8 9.7 3.8 10.7 3.3 10.2
120 3.3 10.2 2.9 9.8 3.7 10.6 3.2 10.1 4.4 11.3 3.7 10.6
140 3.8 10.7 3.2 10.1 4.2 11.1 3.6 10.5 4.9 11.8 4.2 11.1
100 3.4 10.8 2.9 10.3 3.8 11.2 3.2 10.6 4.4 11.8 3.8 11.2
120 3.9 11.3 3.3 10.7 4.3 11.7 3.7 11.1 5.1 12.5 4.3 11.7
140 4.4 11.8 3.8 11.2 4.9 12.3 4.2 11.6 5.7 13.1 4.9 12.3
100 3.8 11.7 3.3 11.2 4.2 12.1 3.6 11.5 4.9 12.8 4.2 12.1
120 4.4 12.3 3.7 11.6 4.9 12.8 4.2 12.1 5.7 13.6 4.9 12.8
140 4.9 12.8 4.2 12.1 5.5 13.4 4.7 12.5 6.4 14.3 5.5 13.4
100 4.1 12.3 3.5 11.8 4.6 12.9 3.9 12.2 5.3 13.6 4.6 12.9
120 4.7 13.0 4.0 12.3 5.3 13.6 4.5 12.8 6.1 14.4 5.3 13.6
140 5.3 13.6 4.5 12.8 5.9 14.2 5.1 13.4 6.9 15.2 5.9 14.2
100 4.3 12.9 3.7 12.3 4.8 13.4 4.1 12.7 5.6 14.2 4.8 13.4
120 5.0 13.6 4.3 12.9 5.6 14.2 4.8 13.4 6.5 15.1 5.6 14.2
140 5.6 14.2 4.8 13.4 6.3 14.9 5.4 14.0 7.3 15.9 6.3 14.9
60° 5.9
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 6 Feet at
Lowest Part of the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is
4-inch Schedule 40. Highlighted sections in the table below require 4-inch Schedule 80 Pipe.
SoilType→ Class3 Class4 Class5
TTP‐A-2ForArrayGroundClearanceof6Feet
60°
7.1
7.7
8.1
8.6
8.9
50°
24" 36"
20°
30°
40°
FoundationDiameter→ 24" 36" 24" 36"
36"
20°
30°
40°
50° 5.6
5.1
4.7
FoundationDiameter→ 24" 36" 24" 36" 24"
4.1
TTP‐A-2ForArrayGroundClearanceof3Feet
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 3 Feet at
Lowest Part of the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is
4-inch Schedule 40. Highlighted sections in the table below require 4-inch Schedule 80 Pipe.
SoilType→ Class3 Class4 Class5

Installaon Manual Pole Mount
TTP-A Series
7support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Array
Tilt
Angle↓
Wind
Speed
(mph)↓
Pipe
Above
Ground
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
100 3.0 7.5 2.5 7.0 3.3 7.8 2.8 7.3 3.9 8.4 3.3 7.8
120 3.5 7.9 2.9 7.4 3.8 8.3 3.3 7.8 4.5 9.0 3.8 8.3
140 4.0 8.4 3.3 7.8 4.3 8.8 3.7 8.2 5.1 9.6 4.3 8.8
100 3.6 8.9 3.1 8.4 4.0 9.3 3.4 8.7 4.7 10.0 4.0 9.3
120 4.2 9.5 3.6 8.9 4.6 9.9 3.9 9.2 5.4 10.7 4.6 9.9
140 4.7 10.0 4.0 9.3 5.2 10.5 4.4 9.7 6.1 11.4 5.2 10.5
100 4.1 10.1 3.5 9.5 4.5 10.5 3.9 9.9 5.3 11.3 4.5 10.5
120 4.7 10.7 4.0 10.0 5.3 11.2 4.5 10.5 6.2 12.2 5.2 11.2
140 5.3 11.3 4.5 10.5 5.9 11.9 5.0 11.0 7.0 13.0 5.9 11.9
100 4.4 11.0 3.8 10.4 4.9 11.5 4.2 10.8 5.8 12.4 4.9 11.5
120 5.1 11.7 4.4 11.0 5.7 12.3 4.8 11.4 6.6 13.3 5.6 12.1
140 5.7 12.3 4.9 11.5 6.4 13.0 5.4 12.0 7.5 14.1 6.2 13.0
100 4.7 11.8 4.0 11.1 5.2 12.3 4.5 11.6 6.1 13.2 5.2 12.3
120 5.4 12.4 4.6 11.7 6.0 13.1 5.2 12.3 7.1 14.3 6.0 13.1
140 6.1 13.0 5.2 12.3 6.8 13.9 5.8 12.9 8.0 15.1 6.8 13.9
Array
Tilt
Angle↓
Wind
Speed
(mph)↓
Pipe
Above
Ground
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
Hole
Depth
(ft)
Total
Pipe
Length
(ft)
100 3.4 10.9 3.0 10.5 3.8 11.3 3.3 10.8 4.5 12.0 3.8 11.3
120 3.9 11.4 3.4 10.9 4.4 11.9 3.8 11.3 5.2 12.7 4.4 11.9
140 4.4 11.9 3.8 11.3 5.0 12.5 4.3 11.8 5.8 13.3 5.0 12.5
100 4.1 12.4 3.5 11.8 4.5 12.8 3.9 12.2 5.3 13.6 4.5 12.8
120 4.7 13.0 4.0 12.3 5.2 13.5 4.5 12.8 6.1 14.4 5.2 13.5
140 5.3 13.6 4.5 12.8 5.9 14.2 5.0 13.3 6.9 15.2 5.9 14.2
100 4.5 13.5 3.8 12.8 5.0 14.0 4.3 13.3 5.8 14.8 5.0 14.0
120 5.2 14.2 4.4 13.4 5.8 14.8 4.9 13.9 6.7 15.7 5.8 14.8
140 5.8 14.8 5.0 14.0 6.5 15.5 5.5 14.5 7.6 16.6 6.5 15.5
100 4.9 14.5 4.2 13.8 5.5 15.1 4.7 14.3 6.4 16.0 5.5 15.1
120 5.7 15.3 4.8 14.4 6.3 15.9 5.4 15.0 7.4 17.0 6.3 15.9
140 6.4 16.0 5.4 15.0 7.1 16.7 6.1 15.7 8.3 17.9 7.1 16.7
100 5.2 15.3 4.5 14.6 5.8 15.9 5.0 15.1 6.8 16.9 5.8 15.9
120 6.0 16.1 5.2 15.3 6.7 16.8 5.7 15.8 7.8 17.9 6.7 16.8
140 6.7 16.8 5.8 15.9 7.5 17.6 6.4 16.5 8.8 18.9 7.5 17.6
7.7
8.5
9.2
9.8
10.3
36"
SoilType→ Class3 Class4 Class5
FoundationDiameter→ 24" 36" 24" 36" 24"
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 4 Feet at Lowest
Part of the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is 4-inch
Schedule 40. Highlighted sections in the table below require 4-inch Schedule 80 Pipe.
30°
20° 4.7
5.5
60°
50°
40°
30°
20°
24" 36"
60°
50°
40°
FoundationDiameter→ 24" 36" 24" 36"
6.2
6.8
7.3
TTP‐A-3ForArrayGroundClearanceof6Feet
SoilType→ Class3 Class4 Class5
TTP‐A-3ForArrayGroundClearanceof3Feet
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 3 Feet at Lowest
Part of the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is 4-inch
Schedule 40. Highlighted sections in the table below require 4-inch Schedule 80 Pipe.

8
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Array
Tilt
Angle
↓
Wind
Speed
(mph)↓
PipeAbove
Ground(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
100 3.3 7.2 2.8 6.7 3.6 7.5 3.1 7.0 4.3 8.2 3.6 7.5
120 3.8 7.7 3.2 7.1 4.2 8.1 3.6 7.5 5.0 8.9 4.2 8.1
140 4.3 8.2 3.6 7.5 4.8 8.7 4.1 8.0 5.6 9.5 4.8 8.7
100 3.8 8.2 3.2 7.6 4.2 8.6 3.6 8.0 5.0 9.4 4.2 8.6
120 4.4 8.8 3.7 8.1 4.9 9.3 4.2 8.6 5.8 10.2 4.9 9.3
140 5.0 9.4 4.2 8.6 5.6 10.0 4.7 9.1 6.6 11.0 5.6 10.0
100 4.3 9.2 3.6 8.5 4.8 9.7 4.1 9.0 5.6 10.5 4.8 9.7
120 4.9 9.8 4.2 9.1 5.5 10.4 4.7 9.6 6.5 11.4 5.5 10.4
140 5.6 10.5 4.8 9.7 6.3 11.2 5.3 10.2 7.4 12.3 6.3 11.2
100 4.7 10.0 4.0 9.3 5.2 10.5 4.4 9.7 6.1 11.4 5.2 10.5
120 5.4 10.7 4.6 9.9 6.0 11.3 5.1 10.4 7.1 12.4 6.0 11.3
140 6.1 11.4 5.2 10.5 6.9 12.2 5.8 11.1 8.1 13.4 6.9 12.2
100 5.0 10.6 4.2 9.8 5.6 11.2 4.7 10.3 6.5 12.1 5.6 11.2
120 5.7 11.3 4.9 10.5 6.4 12.0 5.5 11.1 7.6 13.2 6.4 12.0
140 6.5 12.1 5.5 11.1 7.3 12.9 6.2 11.8 8.6 14.2 7.3 12.9
Array
Tilt
Angle
↓
Wind
Speed
(mph)↓
PipeAbove
Ground(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
100 3.80 10.68 3.30 10.18 4.20 11.08 3.60 10.48 4.90 11.78 4.20 11.08
120 4.40 11.28 3.70 10.58 4.90 11.78 4.20 11.08 5.70 12.58 4.90 11.78
140 4.90 11.78 4.30 11.08 5.50 12.38 4.70 11.58 6.40 13.28 5.50 12.38
100 4.40 11.80 3.70 11.10 4.90 12.30 4.20 11.60 5.70 13.10 4.90 12.30
120 5.00 12.40 4.30 11.70 5.60 13.00 5.80 12.20 6.60 14.00 5.60 13.00
140 5.70 13.10 4.80 12.20 6.30 13.70 5.40 12.80 7.40 14.80 6.30 13.70
100 4.90 12.77 4.20 12.07 5.40 13.27 4.70 12.57 6.40 14.27 5.40 13.27
120 5.60 13.47 4.80 12.67 6.30 14.17 5.40 13.27 7.40 15.27 6.30 14.17
140 6.30 14.17 5.40 13.27 7.10 14.97 6.00 13.87 8.30 16.17 7.10 14.97
100 5.30 13.58 4.50 12.78 5.90 14.18 5.00 13.28 6.90 15.18 5.90 14.18
120 6.10 14.38 5.20 13.48 6.80 15.08 5.80 14.08 8.00 16.28 6.80 15.08
140 6.80 15.08 5.80 14.08 7.70 15.98 6.50 14.78 9.00 17.28 7.70 15.98
100 5.60 14.21 4.80 13.41 6.20 14.81 5.30 13.91 7.30 15.91 6.20 14.81
120 6.40 15.01 5.50 14.11 7.20 15.81 6.10 14.71 8.40 17.01 7.20 15.81
140 7.20 15.81 6.20 14.81 8.10 16.71 6.90 15.51 9.50 18.11 8.10 16.71
TTP‐A-4andTTP‐A-4HWforArrayGroundClearanceof3Feet
4.7
5.1
20°
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 3 Feet at Lowest Part of
the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is 6-inch Schedule 40
(Highlighted sections require 6-inch Schedule 80 Pipe)
SoilType→ Class3 Class4 Class5
FoundationDiameter→ 36"
4.1
24" 36" 24" 36"
60°
30°
40°
50°
60°
20°
30°
40°
50°
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 6 Feet at Lowest Part of
the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is 6-inch Schedule 40
(Highlighted sections require 6-inch Schedule 80 Pipe)
SoilType→
FoundationDiameter→
5.5
5.9
36" 24"
7.13
7.65
8.12
8.53
8.86
24"
36" 24" 36"
Class3 Class5Class4
24"
TTP‐A-4andTTP‐A-4HWforArrayGroundClearanceof6Feet

Installaon Manual Pole Mount
TTP-A Series
9support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Array
Tilt
Angle↓
Wind
Speed
(mph)↓
PipeAbove
Ground(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
100 3.9 8.4 3.3 7.8 4.3 8.8 3.7 8.2 5.1 9.6 4.3 8.8
120 4.5 9.0 3.8 8.3 5.0 9.5 4.2 8.7 5.9 10.4 5.0 9.5
140 5.0 9.5 4.3 8.8 5.7 10.2 4.8 9.3 6.7 11.2 5.7 10.2
100 4.6 9.9 4.0 9.3 5.2 10.5 4.4 9.7 6.1 11.4 5.2 10.5
120 5.4 10.7 4.6 9.9 6.0 11.3 5.1 10.4 7.1 12.4 6.0 11.3
140 6.1 11.4 5.2 10.5 6.8 12.1 5.8 11.1 8.1 13.4 6.8 12.1
100 5.3 11.3 4.5 10.5 5.9 11.9 5.0 11.0 6.9 12.9 5.9 11.9
120 6.2 12.1 5.2 11.2 6.8 12.8 5.8 11.8 8.0 14.0 6.8 12.8
140 6.9 12.9 5.8 11.8 7.7 13.7 6.6 12.6 9.1 15.1 7.7 13.7
100 5.7 12.3 4.8 11.4 6.4 13.0 5.4 12.0 7.5 14.1 6.4 13.0
120 6.6 13.2 5.6 12.2 7.4 14.0 6.3 12.9 8.7 15.3 7.4 14.0
140 7.4 14.0 6.3 12.9 8.3 14.9 7.1 13.7 9.9 16.5 8.3 14.9
100 6.1 13.2 5.2 12.3 6.8 13.9 5.8 12.9 8.0 15.1 6.8 13.9
120 7.0 14.1 6.0 13.1 7.8 14.9 6.7 13.8 9.2 16.3 7.8 14.9
140 7.9 15.0 6.7 13.8 8.9 16.0 7.5 14.6 10.5 17.6 8.9 16.0
Array
Tilt
Angle↓
Wind
Speed
(mph)↓
PipeAbove
Ground(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
Hole
Depth
(ft)
TotalPipe
Length(ft)
100 4.4 11.9 3.8 11.3 4.9 12.4 4.2 11.7 5.8 13.3 4.9 12.4
120 5.1 12.6 4.4 11.9 5.7 13.2 4.9 12.4 6.7 14.2 5.7 13.2
140 5.7 13.2 4.9 12.4 6.4 13.9 5.5 13.0 7.5 15.0 6.4 13.9
100 5.3 13.6 4.5 12.8 5.9 14.2 5.0 13.3 6.9 15.2 5.9 14.2
120 6.0 14.3 5.2 13.5 6.8 15.1 5.8 14.1 7.9 16.2 6.8 15.1
140 6.8 15.1 5.8 14.1 7.6 15.9 6.5 14.8 9.0 17.3 7.6 15.9
100 5.8 14.8 4.9 13.9 6.4 15.4 5.5 14.5 7.5 16.5 6.4 15.4
120 6.6 15.6 5.7 14.7 7.4 16.4 6.3 15.3 8.7 17.7 7.4 16.4
140 7.5 16.5 6.4 15.4 8.4 17.4 7.1 16.1 9.8 18.8 8.4 17.4
100 6.3 15.9 5.4 15.0 7.1 16.7 6.1 15.7 8.3 17.9 7.1 16.7
120 7.3 16.9 6.2 15.8 8.2 17.8 7.0 16.6 9.6 19.2 8.2 17.8
140 8.2 17.8 7.0 16.6 9.2 18.8 7.8 17.4 10.8 20.4 9.2 18.8
100 6.7 16.8 5.8 15.9 7.5 17.6 6.4 16.5 8.8 18.9 7.5 17.6
120 7.7 17.8 6.6 16.7 8.7 18.8 7.4 17.5 10.2 20.3 8.7 18.8
140 8.7 18.8 7.4 17.5 9.8 19.9 8.3 18.4 11.5 21.6 9.8 19.9
TTP‐A-6andTTP‐A-6HWforArrayGroundClearanceof3Feet
SoilType→
4.71
60°
20°
30°
40°
50°
20°
30°
40°
50°
60°
24" 36"
Class3 Class4 Class5
8.5
9.21
36" 24" 36"
24" 36"
Class3 Class4 Class5
FoundationDiameter→
TTP‐A-6andTTP‐A-6HWforArrayGroundClearanceof6Feet
9.83
10.33
24"
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 3 Feet at lowest part of the
array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is 6-inch Schedule 40 (Highlighted
sections require 6-inch Schedule 80 Pipe)
Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 6 Feet at lowest part of the
array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameters. Vertical Pipe is 6-inch Schedule 40 (Highlighted
sections require 6-inch Schedule 80 Pipe)
SoilType→
FoundationDiameter→
7.71
36" 24" 36"
5.50
6.21
6.83
7.33
24"

10
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Step One - Pole Cap Assembly
• Place Pole Cover on top of mounng pole.
• Put 3/4 x 8-inch Cap Support Bolt through the two top holes in rear half of the Pole Cap,
install nut and ghten rmly. It is not necessary to torque this bolt and nut. This bolt keeps
the Pole Cap from sliding down the post.
• Put the two 3/4 x 9-inch bolts into back half of Pole Cap, then through front
(larger) half, and put nut loosely on the bolt. These large nuts and bolts may
be dicult to thread together by hand. Start nuts on bolts by hand and use
wrenches as needed. Booms of cap will hook together.
• Slide assembled Pole Cap over 6-inch vercal pole. Front and back of cap
assembly should be aligned so the two 9-inch bolts are approximately
horizontal and top edge of the front (larger) part of cap is against the vercal
pole. Rotate Pole Cap on post so front (larger) half of Pole Cap is on side of
pole that array will be facing.
• Loosely install the four 1/2-inch set screws in threaded holes on rear half of
Pole Cap. Do not ghten at this me.
• Securely ghten the two 3/4” bolts in Pole Cap assembly, keeping them
horizontal. Tighten enough that front of cap will not slide down the pipe.
Do not fully torque to specicaon unl nal assembly is complete.
Step Two - Assemble H-Frame
• Slide 2-1/2-inch Pivot Pipe (2-7/8” O.D.) through holes on side of front half of
Top Cap and center in front half of Top Cap.
• Bolt a 2 x 3-inch Tube to each side of Pivot Pipe with a 1/2 x 3-inch bolt, at
washer and split lock washer. Use hole in the center of the 2” x 3” Tube.
• Bolt 2-inch Adjuster Pipe (2-3/8-inch O.D.) between the two 2 x 3-inch Tubes
with a 1/2 x 3-inch bolt, at washer, and split lock washer on each side.
Assembly should look like picture below. Tighten the 4 bolts to 45 -lbs.

Installaon Manual Pole Mount
TTP-A Series
11support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Step Three - Assemble Adjuster Arm
• Aach Adjuster Arm to Adjuster
Pipe with a 2-3/8-inch U-bolt and
two ange nuts as pictured at
right. Hand ghten, for now.
• Using Adjuster Arm move
2 x3-inch rectangular tubes
to approximately horizontal
posion. Set this posion by
inserng a 1/2 x 1-inch bolt thru
hole in Adjuster Arm and then
thru hole in tab on rear of Pole
Cap, nger-ghten. Final array
angle will be readjusted in a
future step.
Step Four - Rail Support Pipes
• 4 module and 6 module mounts will require either two 10-foot 2-inch pipes, if module length is less than 78-inches,
or two 12-foot pipes, if modules are longer than 78-inches. Use schedule 40 pipe for TTP-A-4 and TTP-A-6 mounts.
Use schedule 80 pipe for TTP-A-6HW or TTP-A-4HW mounts.
• 2 module and 3 module mounts require two 5-foot 2-inch schedule 40 pipes.
• If using one of our 10-foot or 12-foot Pipe Kits, pipe ships in two secons. Connect two of the 2-inch Schedule 40
or 80 x 5-foot long or 6-foot long Rail Support Pipes together using a 2-inch pipe coupling, ghten with two pipe
wrenches. Repeat with remaining two 2-inch Schedule 40 or 80 x 5-foot long Rail Support Pipes and coupling. Pipe,
when purchased locally, can be purchased in full, needed length to eliminate need for couplings.
• Aach assembled Rail Support Pipes
to at ends of 2 x 3-inch Rectangular
Tubing using two 2-3/8-inch x 1/2-
inch U-bolts at the end of each 2 x
3-inch tube. Center these pipes on
assembly.
• Tighten nuts on U-bolts to 15 -lbs.

12
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Step Five - Module Mounng Rail Assembly
• Two and four module mounts: use 85-inch long Module Mounng Rails provided.
• Three and six module mounts: ship with 132-inch Module Mounng Rails made of two
66-inch secons.
1) Splice two 66-inch rail together using provided Splice and two 5/16 x 1.125-inch
bolts and Channel Nuts. Slip Splice 5-inches into end of one rail secon, place a
Channel Nut and bolt approximately 2.5-inches from the rail end and ghten.
2) Slide second secon of rail over splice, bung two rail ends together, and repeat
Channel Nut installaon process.
3) Repeat steps #1 and #2 with the other three 85-inch and 42.5-inch rail
secons and Splices.
• Tighten all Splice bolts in the four completed 132-inch assemblies to 12 -lbs.
Step Six - Aach Module Mounng Rails
• Module Mounng Rails locaon on Rail Support Pipes should be approximately lined up with PV module frame
mounng holes being used, or at a posion 1/4 of the length of PV module from each end of the module.
• Locate Rail posions on Rail Support Pipes and place one Pipe Mount on pipe in each locaon.
Two and three module mounts have two rails and four Pipe Mounts. Four and six module mounts
have four rails and eight Pipe Mounts.

Installaon Manual Pole Mount
TTP-A Series
13support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
• Place one Module Mounng Rails on two of the Pipe Mounts installed on the Rail
Support Pipes. Center rail in north/south direcon so it extends past both Support
Pipes the same distance. Make sure Pipe Mount slips into both the mounng
features on the boom of the rails (see drawing at right). Tighten 5/16-inch bolts
with a 1/2-inch socket to 12 -lbs.
• Repeat with remaining Module Mounng Rails.
Step Seven - System Grounding
• Tamarack Module Mounng Rails and the PV module frames are electrically bonded
together by Tamarack Module Clamps. This creates a single electrically bonded unit for
grounding purposes per UL 2703 requirements. One Ground Lug is required to provide
equipment grounding for each column of PV modules.
• A Ground Lug can be aached at any locaon desired on either one of the two Module
Support Rails in each column.
• Connect both ground lugs to the ground wire in the system according to local code.
Step Eight - Mount PV Modules on Rails
• Before mounng the PV modules to the pole mount, map out desired
locaon of the wiring juncon boxes and module output cables.
• To center modules on rails, calculate the amount of excess Module
Mounng Rail length you will have based on width of PV modules being
used.
1) Add together widths of modules in a column plus 1/2-inch for each
space between modules in the column.
2) For TTP-A-4 and TTP-A-4HW: subtract above calculated number from 85.
For TTP-A-6 and TTP-A-6HW: subtract above calculated number from 132.
3) Calculated number is excess length, in inches, of Module Mounng Rails based on width of the parcular PV
modules being mounted.

14
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
• Start module installaon at boom of rst column. Measure up the rail
by 1/2 of the distance calculated in #2 above. Place one Module Clamp
on each Module Mounng Rails at this distance. Ensure side of the top
clamp with two bonding pins faces module frame.
• Center rst module east-to-west over rails and hold in place. To allow
for at least 1/2-inch of space between the two columns of modules,
make sure inside edge of module’s frame is at least 1/4” outward from
the center of the Rail Support Pipes. You can use 2-inch pipe couplings
in assembled Rail Support Pipes to determine the center. Make sure
module is straight and level on rails and ghten two end clamp bolts to
108 inch-pounds (9 foot-pounds).
• Install one Module Clamp in each rail on other side of the rst module,
slide it down so inside of clamp contacts frame of rst module. Springs
will hold the clamps in place prior to ghtening. Place second module on
rails, align with the rst module, and slide down fully into the two mid-
clamps. Tighten mid-clamp bolts to 144 inch-pounds (12 foot-pounds) to
fully secure module.
• Install third module in the column on TTP-A-6 or TTP-A-6HW following
previous steps.
• On top edge of last module of rst column, install two Module Clamps
ensuring sides with two stainless-steel pins are facing in toward module frame, and clamp is ght up against the
module frame. Tighten two end clamp bolts to 108 inch-pounds (9 foot-pounds).
• Install next column of modules in same manner. Leave at least 1/2-inch of spacing between columns.
• Do nal check to be sure all bolts and installaon hardware on the array are properly ghtened to the specied
torque values.
Final Assembly
• To set array lt, remove previously installed 1/2 x 1-inch bolt from Adjuster Arm, lt array to desired angle, line up
hole in Adjuster Arm that is closest to correct angle with hole in the tab on the Pole Cap assembly. Insert 1/2-inch
bolt back through Adjuster Arm and tab, replace the nut, and ghten to 40 foot-pounds..
• Tighten U-bolt on the Adjuster Arm to 12 -lbs.
• Rotate enre array around pole to point in desired direcon. Tighten 3/4-inch nuts on the Pole Cap to 100 -lbs.
• Tighten all 1/2-inch set screws on Pole Cap to 40 -lbs with a 3/4-inch socket.
Technical Support: 707-234-8107 or 800-819-7236 Ext 556

Installaon Manual Pole Mount
TTP-A Series
15support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Manufacturer Model
Aleo P18/P19/S18/S19/S59/S79.
AU Optronics PM Series
Astronergy modules with 30, 35, 40, and 45 mm frames aaSMbbyyC/zz-xxx Where “aa” can be CH or A; "bb" can be 60, 66, or 72; “yy” can be blank, 10 or
12; "C" can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and “zz” can be blank, HV, F-B, or F-BH
Auxin modules with 40 mm frames AXN6y6zAxxx Where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; and "A" can be F or T
Axitec Modules with 35 and 40 mm frames AC-xxxY/aaZZb Where "Y" can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72,
120, or 144; "b" can be S
Boviet Boviet modules with 35 and 40mm frames - BVMZZaaYY-xxxBcc Where "ZZ" can be 66 or 76; "aa" can be 9, 10 or 12; "YY" is M or P; and
"B" can be blank, L or S; and "cc" can be blank, H, H-BF, H-BF-DG, H-HC, H-HC-BF, H-HC-BF-DG, HC-BF or HC-BF-DG]
BYD BYD modules with 35 mm frames BYDxxxAY-ZZ Where "A" can be M6, P6, MH or PH; "Y" can be C or K; and "ZZ" can be 30 or 36
Canadian Solar Canadian Solar modules with 30, 32, 35, and 40 mm frames - CSbY-xxxZ Where "b" can be 1, 3 or 6; "Y" can be H, K, L, N, P, U, V, W, X or
Y; and "Z" can be M, P, MS, PX, M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD
CentrsoSolar C and E series.
Certainteed CertainTeed modules with 35 and 40 frames CTxxxYZZ-AA Where "Y" can be M, P, or HC; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01,
02, 03, or 04
CSUN Csun modules with 35 and 40 mm frames - YYxxx-zzAbb Where "YY" is CSUN or SST; "zz" is blank, 60, or 72; and "A" is blank, P, M or MM;
"bb" is blank, BB, 5BB, BW, or ROOF
Dehui Dehui modules with 30, 35 and 40mm frames - DH-MYYYZ-xxx Where "YYY" can be 760, 772, 860, 872; and "Z" can be B, F or W
Eco Solargy ORION 1000 ECOXXXH156P-60, APOLLO 1000 ECOXXXT156M-60, and APOLLO 1000 ECOXXXA156M-60.
ET Solar 30, 35, 40, and 50 mm frames ET-Y6ZZxxxAA Where “Y” can be P, L, or M; “ZZ” can be 60, 72 or 72BH; and “AA” can be GL, WB, WW, BB,
WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC
GCL 40mm frame: GCL-P6/72, 35mm frame: GCL-P6/72, GCL-P6/72H, GCL-M6/72, GCL-M6/72H, 35mm frame (Black frame): GCL-P6/60, GCL-
M6/60
GigaWatt Solar: Gigawatt modules with 40 mm frames - GWxxxYY Where “YY” can be either PB or MB
Hanwha Q-Cells
Modules with 32, 35, 40, and 42mm frames aaYY-ZZ-xxx where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS,
PLUS DUO or PEAK DUO; and "ZZ" can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-
G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR
G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, G5/SC, G5/TS, BLK-G5, BLK-G5/SC, BLK-G5/TS, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-
G5.3, G6, G6/SC, G6/TS, G6+/TS, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/HL, BLK-G6+/SC,
BLK-G6/TS, BLK-G6+/TS, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-
G8.3/BFF, L-G8.3/BFG, L-G8.3/BGT, ML-G9, BLK ML-G9, ML-G9+, BLK ML-G9+, ML-G10, BLK ML-G10, ML-G10+, BLK ML-G10+, ML-
G10.a, BLK ML-G10.a, ML-G10.a+, BLK ML-G10.a+, XL-G9, XL-G9.2, XL-G9.3, XL-G9.3/BFG, XL-G10.2, XL-G10.3, XL-G10.c, XL-G10.d, XL-
G10.d/BFG or XL-G10.3/BFG
Hansol Hansol modules with 35 and 40 frames HSxxxYY-zz Where "YY" can be PB, PD, PE, TB, TD, UB, UD, or UE; and "zz" can be AH2, AN1,
AN3, AN4, HH2, HV1, or JH2]
Heliene Heliene modules with 40 mm frames - YYZZxxxA Where "YY" can be 36, 60, 72, 96, 120 or 144; "ZZ" can be HC, M, P, or MBLK; and "A" can
be blank, HomePV, or Bifacial]
HT Solar HT60-156(M) (NDV) (-F), HT 72-156(M/P)
Hyundai Hyundai modules with 33, 35, 40 and 50 mm frames - HiY-SxxxZZ Where "Y" can be A, D or S; "S" can be M or S; and "ZZ" can be GI, HG,
HI, KI, MI, MF, MG, PI, RI, RG, RG(BF), RG(BK), SG, TI or TG
ITEK 40 and 50 mm frames IT-xxx-YY Where “YY” can be blank, HE, or SE, or SE72
JA Solar
30, 35, 40 and 45 mm frames JAyyzz-bbww-xxx/aa Where “yy” can be M, P, M6 or P6; “zz” can be blank, (K), (L), (R), (V), (BK), (FA), (TG),
(FA)(R), (L)(BK), (L) (TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); “bb” can be 48, 60, or 72; “ww” can be D09, S01, S02, S03,
S06, S09, S10, or S12; and “aa” can be BP, MR, SI, SC, PR, 3BB, 4BB, 4BB/RE, 5BB
Japan Solar JPS-xxxP-60 (35mm), JPS-xxxM-60 (35mm), JPS-xxx-P-72 (40mm), JPS-xxxM-60-BB (35mm), JPS-xxx-P-72-BB (40mm)
Kyocera KU26x-6MCA where x is 0 or 5.
LG [LG modules with 35, 40, and 46 mm frames - LGxxxYaZ-bb Where "Y" can be A, E, M, N, Q, S; "a" can be A, 1, 2 or 3 "Z" can be C, K, T, or
W; and "bb" can be A3, A5, A6, B3, B6, E6, G3, G4, J5, K4, L5, N5, V5 or V6]
LONGi [Longi modules with 30, 35 and 40 mm frames - LRa-YYZZ-xxxM Where "a" can be 4, 5 or 6; "YY" can be blank, 60 or 72; and "ZZ" can be
blank, BK, BP, HV, PB, PE, PH, HBD, HIB, HIH, HPB, HPH, or HIBD]
Mission Solar 33 and 40 mm frames MSEbbxxxZZaa Where “bb” can be blank or 60A; “ZZ” can be blank, MM, SE, SO, SQ , SR, or TS; and “aa” can be
blank, 1J, 4J, 4S, 5K, 5T, 60, 6J, 6S, 6W, 8K, 8T, or 9S
Mitsubishi Mitsubishi modules with 46 mm frames - PV-MYYxxxZZ Where "YY" can be LE or JE; and "ZZ" can be either HD, HD2, or FB
CertifiedModuleListforUL2703ListingProgram
35 and 40 mm frames JKMYxxxZZ-aa Where “Y” can either be blank or S; “ZZ” can be M, P, or PP; and “aa” can be blank, 60, 60B, 60H, 60L,
60BL, 60HL, 60HB, 60HBL, 6HBL-EP, 60-J4, 60B-J4, 60B-EP, 60(Plus), 60-V, 60-MX, 7RL3-V, 7RL3-TV, 72, 72B, 72-J4, 72B-J4, 72(Plus), 72-
V, 72H-V, 72L-V, 72HL-V, 72-MX, 72H-BDVP, 72HL-TV, or 72HL-V-MX3
Jinko

16
Installaon Manual Pole Mount
TTP-A Series
support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
Manufacturer Model
NSP D6M and D6P
Panasonic 30 mm frames EVPVxxxA, Where “A” can be blank or KPanasonic modules with 35 and 40 mm frames VBHNxxxYYzzA Where “YY” can be
either KA, RA, SA or ZA; “zz” can be either 01, 02, 03, 04, 06, 06B, 11, 11B, 15, 15B, 16, 16B, 17, or 18; and “A” can be blank, E, G, or N
Peimar 40 mm frames SbxxxYzz Where “b” can be G, M or P; “Y” can be M or P; and “zz” can be blank, (BF) or (FB)
Phono Solar Phono Solar modules with 35, 40, and 45 mm frames - PSxxxY-ZZ/A Where "Y" can be M, M1, MH, M1H, M4, M4H or P; "ZZ" can be 20 or
24; and "A" can be F, T, U, UH, or TH]
Risen RSM72-6 (MDG) (M), RSM60-6
REC Solar REC modules with 30, 38 and 45 mm frames - RECxxxYYZZ Where “YY” can be AA, M, NP, NP2, PE, PE72, TP, TP2, TP2M, TP2SM,
TP2S, TP3M or TP4; and “ZZ” can be blank, Black, BLK, BLK2, SLV, 72, or Pure
Renesola Virtus II with module ratings of 250-260 in increments of 5. 156 series with module ratings of 270-275.
S-Energy S-Energy modules with 35 and 40mm frames - SABB-CCYYY-xxxZ Where "A" can be C, D, L or N; "BB" can be blank, 20, 25, 40 or 45; "CC"
can be blank, 60 or 72; "YYY" can be blank, BDE, MAE, MAI, MBE, MBI, MCE or MCI; and "Z" can be V, M-10, P-10 or P-15
Seraphim Energy
Group
Seraphim modules with 30, 35, and 40 mm frames - SEG-aYY-xxxZZ Where "a" can be blank, 6 or B; "YY" can be blank, MA, MB, PA, or PB;
and "ZZ" can be blank, BB, BG, BW, HV, WB, WW, BMB, BMA-HV, BMA-BG, BMB-HV
Seraphim USA Seraphim modules with 30, 35, 40 and 50 mm frames - SRP-xxx-YYY-ZZ Where "xxx" is the module power rating; and "YYY" can be BMA,
BMD, 6MA, 6MB, 6PA, 6PB, 6QA-XX-XX, and 6QB-XX-XX; ZZ is blank, BB, BG or HV
Sharp 60 and 72 NUSA-xxx/NUSC-xxx
Silfab Silfab Modules with 35 and 38 mm frames - SYY-Z-xxxAb Where "YY" can be IL, SA, LA, SG or LG; "Z" can be blank, M, P, or X; "A" can be
blank, B, H, M, N; and "b" can be A, C, L, G, K, T, U or X
SolarWorld
Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 31, 33 or 46 mm frames
SW-xxx, SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 33
mm frames SWA-xxx
Solaria 40 mm frames PowerXT xxxY-ZZ Where “Y” can be R or C; and “ZZ” can be AC, BD, BX, BY, PD, PM, PM-AC, PX, PZ, WX or WZ
Sonali SS 230 - 265
SunEdison SunEdison Modules with 35, 40 & 50 mm frames - SE-YxxxZABCDE Where "Y" can be B, F, H, P, R, or Z; "Z" can be 0 or 4; "A" can be
B,C,D,E,H,I,J,K,L,M, or N ; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2
Suniva Suniva modules with 35, 38, 40, 46, and 50 mm frames - OPTxxx-AA-B-YYY-Z and MVXxxx-AA-B-YYY-Z Where "AA" is either 60 or 72; "B"
is either 4 or 5; "YYY" is either 100,101,700,1B0, or 1B1; and "Z" is blank or B
Sunpower Sunpower standard (G3 or G4) or InvisiMount (G5) 40 and 46 mm frames - SPR-Zb-xxx-YY Where "Z" is either A, E, P or X; “b” can be blank,
17, 18, 19, 20, 21, or 22; and “YY” can be blank, BLK, COM, C-AC, D-AC, E-AC, BLK-E-AC, G-AC, BLK-C-AC, or BLK-D-AC
SunSpark 40 mm frames SYY-xxxZ-A Where “YY” can be MX or ST; and “Z” can be M, MB, M3, M3B, P or W; and "A" can be 60 or 72
Suntech 35, 40 and 50mm frames STPxxxy-zz/aa Where "y" is blank or S; and "zz" can be 20, 24, A60 or A72U; and "aa" can be Vd, Vem, Vfw, Vfh,
Wdb, Wde, Wd, or Wfhb
Talesun Talesun modules with 30, 35 and 40mm frames - TA6yZZaaxxx-b Where "A" can be D or P, "y" can be blank, F, G, H, I, or L; "ZZ" can be 60
or 72; "aa" can be M, M(H), or P; and "b" can be blank, B, T, or (H)
Tesla Tesla modules with 40 mm frames - TxxxY Where "Y" can be H or S
Trina Solar
Trina Modules with 30, 35, 40 and 46mm frames - TSM-xxxYYZZ Where "YY" can be DD05, DD06, DD14, DE14, DE15, DE15V, DEG15,
DEG15VC, DE19, DEG19C.20, DE06X, PA05, PC05, PD05, PD06, PA14, PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, .05, .05(II),
.08, .10, .18, .08D, .18D, 0.82, .002, .00S, 05S, 08S, .20(II), A, A.05, A.08, A.10, A.18, (II), A(II), A.05(II), A.08(II), A.082(II), A.10(II), A.18(II),
H, H(II), H.05(II), H.08(II), HC.20(II), HC.20(II), M, M(II), M.05(II), MC.20(II)
Upsolar UP-MxxxP, UP-MxxxP-B, UP-MxxxM, UP-MxxxM-B
Vikram 40 mm frames VSyy.ZZ.AAA.bb Where "yy" can be M, P, MBB, MH, MS, MHBB, or PBB; "ZZ" can be 60 or 72; "AAA" is the module power
rating; and "bb" can be 03.04 or 05
Yingli YL xxx P-29b, YLM 60, YLM 72, YGE, YGE-VG, YLM, YL xxx P-35b, YL xxx D-30b, YL xxx D-36b
Waaree AC, Adiya 60/72 Mono/Poly Black, Adiya 60/72 Multi
Winaico 35 and 40 mm frames Wsy-xxxZa Where "y" can be either P or T; "Z" can be either M, P, or MX; and "a" can be blank or 6
CertifiedPowerOptimizerListforUL2703ListingProgram
Manufacturer Model
EnphaseM250‐72,250‐60,M215‐60,C250‐72,S230,S280,IQ6,IQ6+,IQ7,IQ7+,IQ7X,QAggregator
SolarEdgeP300,P320,P340,P370,P400,P405,P505,P600,P700,P730,P800p,P800s,P850,P860
CertifiedModuleListforUL2703ListingProgram

Installaon Manual Pole Mount
TTP-A Series
17support@tamaracksolar.com 1-800-819-7236 Ext 556 PAGE
This manual suits for next models
5
Table of contents
Other Tamarack Solar Rack & Stand manuals

Tamarack Solar
Tamarack Solar UNI-SP/01XH User manual

Tamarack Solar
Tamarack Solar UNI-TL10 User manual

Tamarack Solar
Tamarack Solar LTP HW Mount Series User manual

Tamarack Solar
Tamarack Solar UNI-PGRM 2019 Series User manual

Tamarack Solar
Tamarack Solar SP-KNBR-001 User manual

Tamarack Solar
Tamarack Solar TTP Series User manual

Tamarack Solar
Tamarack Solar UNI-SPHD/4-90 User manual

Tamarack Solar
Tamarack Solar LTP HW Mount Series User manual

Tamarack Solar
Tamarack Solar UNI-PGRM Series User manual