1. Introduction -------------------------------------- 3
2. Important safeguards -------------------------------------- 4
3. LCDI power cord and plug -------------------------------------- 5
4. Parts names -------------------------------------- 6
5. Installation -------------------------------------- 7
6. Operating instruction -------------------------------------- 9
7. Water drainage -------------------------------------- 13
8. Maintenance and cleaning -------------------------------------- 14
9. Troubleshooting -------------------------------------- 15
10. Specification -------------------------------------- 16
11. 產品介紹 -------------------------------------- 17
12. 使用安全須知 -------------------------------------- 18
13. LCDI 電源線與插座 -------------------------------------- 19
14. 產品部位名稱 -------------------------------------- 20
15. 安裝注意事項 -------------------------------------- 21
16. 操作使用說明 -------------------------------------- 23
17. 排水方式 -------------------------------------- 27
18. 產品清潔與維護 -------------------------------------- 28
19. 異常故障排除 -------------------------------------- 29
20. 產品規格 -------------------------------------- 30
21. Tatung Limited Warranty -------------------------------------- 31
TABLE OF CONTENTS

- 3 -
Thank you for choosing Tatungs Portable Air Conditioner . We hope you enjoy this instant cooling portable air
Please read this manual carefully before using this product.
The following tips may help to maximize the efficiency of your air conditioner:
• When the air conditioner is on, keep doors and windows closed.
• Turn off kitchen or bathroom exhaust fans when your air conditioner is on.
• Turn off the air conditioner when you leave home.
• Check the filters monthly.
• Do not place anything that may generate heat near t he thermostat since it may sense the heat and will
make the air conditioner run longer than necessary.
• Keep blinds and curtains closed during hot weather.
• Do not block the air vents. A free flowing air conditioner operates most efficiently
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
INTRODUCTION
conditioner.

- 4 -
When using electrical appliances,basic sa fety precautions should always be followed:
1. Read all instructions
2. To protect against fire,electric shock and personal injury, do not immerse cord, plugs, or the unit in
water or other liquid.
3. Close supervision is necessary when the product is used around children. This product is not
intended for use by chirdren.
4. Do not operate the product with a damaged cord/plug.If the plug is damaged, please return the
product for repair.
5. Always keep the product in an upright position.
6. During the transit, the product could be placed up side down, which may cause the oil in the
compressor drain into the refrigerant tubes reducing the cooling efficiency. Thus, before using the
product,keep the product in a upright position for hours. 1 2
7. Connect the product to a properly grounded power supply. Do not use an adapter plug or extension
cord.
8. Do not cover or insert any object into the air inlet and/or outlet.
9. Turn off the power when no one is in the room.
10. Do not place anything in the direct path of the airflow.
11. Do not place the product near any heat source or where gas leakage may occur.
12. Do not use the product near a bath,shower,swimming pool,or in any other steamy, or wet areas.
13. Do not turn off/on the product by plugging or unplugging the power cord directly.
14. Do not modify the power cord or share the outlet with other appliances.
15. Unplug the product from the outlet when not in use and before cleaning.
16. Attachments not recommended by the manufacturer may cause injuries.
17. Do not expose skin, face and eyes directly to cool air for a long period of time.
18. If an abnormal odor or smoke comes from the product, disconnect the unit immediately and contact Tatung
Service Department.
19. Unplug the power from wall outlet before cleaning the filter and do not touch the metal parts inside.
20. Do not apply any kind of insecticide or flammable spray onto or into the unit.
21. Do not step on the product or place objects on the unit.
22. Always place the product on a steady and flat surface.
23. Before storing the product, always drain the water from the unit and clean the filter.
24. Do not use the product for other than its intended use.
The manufacturer disclaims any responsibility if the above instructions are not followed.
The manufacturer reserves the right to make technical changes without notice.
SAVE THESE INSTRUCTIONS
This product is designed for household use only
IMPORTANT SAFEGUARDS
~

- 5 -
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug. The LCDI power cord and plug will shut off the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will not be able to conduct power until the devise has been manually reset. This device provides
protection to reduce the risk of fire due to arcing faults in the power cord. The cord shields are not grounded
and they must be considered as shock hazards if exposed. The cord shield must not be connected to ground
or to any exposed metal.
To ensure if the plug is working properly, please follow the following instructions to test it:
1. Plug power cord into wall outlet.
2. Press TEST button. The circuit should tr ip, cutting power to the air conditioner.
3. Press RESET button for use.
DO NOT USE IF ABOVE TEST FAILS.
In the event the LCDI Plug of the power cord trips by itself, then first examine the cord for any damage. If there
is no damage to the cord, then press the RESET Button. If the
LCDI Plug trips again, then immediately unplug the power supply
cord and Tatung Service Department.
LCDI POWER CORD AND PLUG
WARNING:
1. Do not use the TEST and RESET buttons as “ON” and
“OFF” switches.
2. Do not press the TEST button while the air conditioner is
operating
3. The cord and plug are designed for indoor use only.
4. Periodically examine the cord for any damage. If the
shield gets exposed, immediately unplug the power cord and do not use the unit.
Test button
Reset button

- 6 -
Front view Back view
1. Control panel
2. Horizontal louver
3. Vertical louver
4. Air inlet grille
5. Castor
6. Air Exhaust hose
7. Moving handle
8. Air outlet grille
9. Power cord
10. Water filling
drawer
11. Power cord hook
12. Air filter
Accessories
PARTS NAMES

- 7 -
2. Assemble the air exhaust hose
Connect the end of the hose and adapter
and twist them.
3. Mount the air exhaust duct on the product
(1) Slide the square Adapter A of the exhaust dust to the exhaust
terminal of the unit.
(2) Put the other end to the nearest window. Leave at least 20 inch(50 cm)
space around it.
4. Install the window kit
Your window kit has been designed to fit most standard "vertical"
and "horizontal" window applications. However, it may be necessary for you to modify some
aspects of the installation procedur es for certain types of windows. Please refer to the illustration for
minimum and maximum window openings
Installation in the horizontal window Installation in the Vertical window
INSTALLATION
Adapter A
Adapter B
1. Select a proper installation location
Place the portable air conditioner on a flat and dry location where the air
outlets cannot be obstructed. Leave a 20 inch (50 cm) minimum space
between the product and the wall.
NOTE:
The length of the air exhaust duct can be extended from 17.5 to
62 inch. Using the minimum length of the air exhaust duct could save
energy for you.
This length has been designed especially according to the
specifications of the air conditioner. Do not replace or extend it with
your own hose as this could cause the unit to malfunction.
inch
(20 inch)

- 8 -
5. The correct way of bending the hose
Correct bending
Wrong bending
CAUTION:
This length has been designed especially according to the specifications of the air conditioner. Do not
replace or extend it with your own hose as this could cause the unit to malfunction
INSTALLATION
(51")
(17")

- 9 -
1. Control panel
Timer Press this button to enter time-setting status.
Swing Press this button to make the vertical louver swing automatically. To
stop swing, press the swing button again.
Speed
Up/Down
Mode
Power Press this button to turn on/off the unit.
OPERATING INSTRUCTION
Timer
Swing
Speed
Mode
Power
Press this button for 5 seconds to select high, middle or low fan
Speed. When the machine is on FAN mode, press this button for
five seconds, the system will dry itself; if you want to stop drying,
press for another five seconds.
Press up or down button to set temperature or adjust the time inTimer
mode. When setting timer-on and timer-off, press these two buttons to
adjust the time of starting or shutting off. Press both buttons to convert
from Celsius to Fahrenheit.
Press this button to select cool, heat, dry or fan mode

- 10 -
2. LED Indicator
3. Remote control
Power Press this button to turn on/off the unit
Timer Press this button to set the timer
Swing Press this button to make the vertical louver
swing automatically.
Cool Press this button to choose Cooling mode
Dry Press this button to choose Dehumidifying
mode
Fan Press this button to choose fan mode
Up Press this button to adjust temperature or
timer setting.
Down Press this button to adjust temperature or
timer setting.
High Press this button to select high fan speed
Medium Press this button to select high fan speed
Low Press this button to select high fan speed
Auto mode This function presets the fan speed, mode
and temperature, and the setting cannot be
changed. Under this mode, the default
setting for the temperature is 80.6F(27C),
operating mode is cooling, and fan speed is
low.
OPERATING INSTRUCTION
COOL: On cooling mode, the led will illuminate.
FAN: On fan mode, the led will illuminate.
DRY: On dehumidifying mode, the led will illuminate.
COMP: When compressor is working, the led will illuminate.
FULL: When water is full in the machine, the led will illuminate.
ADD WATER: When the led is illuminating, the user can put some
water in the machine.
HIGH: When the fan speed is on high, the led will illuminate.
MED: When the fan speed is on the middle setting, the led will illuminate.
LOW: When the fan speed is on low, the led will illuminate.
C F
。 。
Celsius degree and Fahrenheit degree indicator

In COOLING and FAN mode, press “SPEED” to adjust the fan speed. There are high, medium and low
- 11 -
5. Simple steps to use cooling mode
6. Setting the timer
(1) Turn off the unit automatically:
When the unit is running, press TIMER to set operating duration, and then the LED will flash five times.
During this period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After
setting, the LED will flash five times and then display the room temperature again. When the
operating duration reaches the pre-set time , the power will turn off automatically.
(2) Turn on the unit automatically:
When the unit is off, press TIMER to set start time, and then the LED will flash five times. During this
period of time, press Up or Down button to adjust se tting time from 0.5 hr. to 24 hr. After setting, the
LED will flash five times and then display the temperature again. Once the set time is reached, the
power will turn on automatically.
(3) Change the setting:
When TIMER is on, you can check the remain time by pressing the TIMER button. It will flash five
times. Press Up or Down button to adjust the timer. The timer can be canceled if you press the TIMER
button once again when LED is flashing.
Attention:
If the unit is suddenly turned off during operation, the compressor will start to run five minutes after the
power is turned back on.
7. Setting operating mode
COOLING: When this mode is selected, the fan will run first and then the compressor will start to run
five minutes after the power is back on. To set y our desired temperature, pr ess UP or DOWN button.
The temperature ranges from 64F 84F (18C 31C). When the room temperature lower than the
setting temperature, the compressor will stop running until the room te mperature is higher than set
temperature.In this case, onl y the fan will keep running.
FAN: When this mode is selected, the temperature setting cannot be changed, but you can set your
desired speed. There is no need to use air exhaust duct in this mode.
DEHUMIDIFING: When this mode is selected, it presets the fan speed and other mode,and these settings
cannot be changed. Under this mode, the compressor will not run, and LCD will display room
temperature. There is no need to use air exhaust duct. You may need to drain water with the drainpipe
if the humidity is very high.
8. Setting temperature
In COOLING mode, press the "UP” button to increase the temperature se tting or press the "DOWN "
button to lower the temperature setting. When the number is flashing, it indicates the temperature you
are setting up. When the number is lit but not flashi ng,it indicates the current room temperature.
9. Setting fan speed
OPERATING INSTRUCTION
*Plug in the power cord and press the “POWER” button
*Press “MODE” to chose COOLING mode.
*Press “UP” or “DOWN“ to set the desired temperature. The temperature ranges from 64F to
84F(18C~31C)
*Press, “SPEED” to set a desired fan speed.
*The fan will run first. After few minutes, the compressor will start to run if the room temperature is
higher then the setting temperature. The compressor will stop running when the room temperature is
below the setting temperature.
~ ~

- 12 -
modes. Each fan speed corresponds to one indicator on LED control panel.Please note: when unit is in
dehumidifier mode, the fan speed cannot be adjusted.
10. About water adding function
Some portable air conditioners in the market can self-evaporate the condenser water, by using water
pump to extract the condenser water collected from the air to cool the condenser in order to increase the
cooling efficiency.
This unit not only self-evaporates the condenser wate
r, but also comes with patented water injection
function, allowing the user to add some water to increase the cooling efficiency,rather than rely on the
condenser water collected from the air.This function is especially useful to the
areas where the humidity is
very low and condenser water is not enough to cool the condenser.
When the water is not enough for the water pump,the pump will stop working.At the same time, the
Water filling light on the control panel will illuminate ,you can fill
some water into the water-filling drawer carefully.To avoid overfilling the
water, use the included measuring cup to fill the water no more than
1800ml (three cups).This operation may help save 20%-30% energy for
you.
Please note, all the functions will work normally even when the water tank is empty and water pump stop
running. You can choose not to add water.However,do not add water if the product is
used in the place where humidity. has moderate or high

- 13 -
During the cooling or dehumidifying mode, the condenser water will be drained into the internal water tank.
Since this unit is equipped with a self-evaporative system,the condenser water will be used to cool the
condenser making the unit run more efficiently. However, if the unit is used in high humidity areas, the water
may need to be drained out. When the water tank is full,the water full indicator at LED control panel will light
up and the compressor will stop running.The buzzer will s ound for 10 times every 5 minutes unit the water is
drained out.
After draining out the water, the alarm will stop and the unit will work normally. The compressor will start to run
five minutes after the power is back on.
You can drain the water out with a drainpipe (included).
Please follow the steps to drain the water:
1. Turn off the power;
2. Place a plate, pan or container under the drain
mouth;
3. Remove the water stopper from the drain mouth,
thus the condenser water will flow out of the water
tank.
4. If you want to continuously drain the water, please
use the drainpipe and follow the steps:
(1) Turn off the power;
(2) Place a plate, pan or container under the
drain mouth;
(3) Take off the water stopper
(4) Connect the supplied drainpipe to the water
mouth, and place a container at the end of
the pipe to collect the water. The condenser water will drai n out automatically into the
container.
(5) If you want to extend the drainpipe,you can use 9mm I.D. plastic pipe to connect with the
supplied drainpipe.
Attention: Do not move the unit while the water is full. It may cause the water to overflow on the floor
and damage the product.
WATER DRAINAGE

- 14 -
Attention: unplug the power from the wall outlet before cleaning.
1. Clean the air filters
Clean the filters regularly to optimize the airflow.
(1) Unplug the power
(2) Pull out the air filters as shown at right figure
(3) Wash the filters by immersing them gently into warm water (no hotter than 104F). Apply some neutral
detergent if necessary and rinse the filter thoroughly.
(4) Put them back to the unit after the filters are dry.
Attention: Never operate the unit without the filter.
2. Clean the housing
(1) Unplug the power
(2) Wipe the surface of the appliance with a wet and soft cloth.
(3) Never use strong chemicals,oil-based products,
detergents,chemically treat ed cloths or other cleaning
solutions.These could damage the plastic surface.
(4) Do not immerse the unit in water
(5) Do not allow water on the control panel as it may cause
malfunction.
3. End of season storage
(1) Unplug the power from wall outlet.
(2) Clean the filter
(3) Drain out the condenser water COMPLETELY.
(Please refer to “water drainage” section.)
(4) Plug the power back in and operate the unit with FAN mode for half day to dry the water inside the
water tank.
(5) Unplug the power and tie the power cord in power cord hook.
(6) Uninstall the air exhaust hose.
(7) Pack the appliance and accessories with its original box.
(8) Store the product in a dry place.
MAINTENANCE AND CLEANING

- 15 -
If you cannot solve the problem or the problem is not listed on above,unplug the power and contact Tatung
Service Department at 1-800-827-2850.
When one the following situations happen,stop running the unit and contact Tatung Service Center:
1. The fuse and switch often break
2. The power cord superheat or sleeve of the cord is broken
3. There is abnormal odor or smoke comes out the units.
!
TROUBLESHOOTING
Symptom
The unit does not
operate
Check
Is the unit plugged in?
Cannot power on?
Does the power turn on?
Is the timer on?
Is the water tank full?
Is the room temperature below the set
temperature?
Is the room too big?
Are there too many people in the room?
Is the filter dirty?
Are there too many windows or doors
open?
Is the room in direct sunshine?
Is the air exhaust hose installed
correctly?
Is the temperature setting too high?
Is there additional heat source nearby?
The unit is too noisy
and vibrates
Is the unit placed on an uneven surface?
Hear the inner liquid flow inside
Action
Plug in the power cord
Check the power switch
Turn on the power
Turn the timer off
Empty the water. Please read the
“Water Drainage” section
Change the temperature setting
Use this unit at the recommended
room size.
The more people in the room, the
longer time it needs to cool the room
Clean the filters
Close the windows and doors
Close the blinds or curtains
Check the air exhaust hose
Change the temperature setting
Remove the heat sources from the
room.
Place the unit on an even surface.
It is normal. That is the sound of
refrigerant flowing inside the
condenser.
Check the voltage 115V/60Hz
Check the exhaust hose
Do not modify or add air exhaust by
yourself .
Place the unit on an even surface.
Make sure the knob is secured tightly
in the drainage spout.
Empty the water. Please read the
“Water Drainage” section.
Contact Tatung Service Center
Contact Tatung Service Center
That is the normal status. The
message will disappear after few
minutes.
Contact Tatung Service Center.
The unit only runs in
fan mode (the
compressor doesn’t
run)
The room is not cool
enough
The unit starts and
stops frequently
Is the proper voltage connected
Is the air exhaust hose installed
incorrectly?
Is the air exhaust hose modified?
Surface is uneven
Drain knob is loose
Is the water tank full?
Water is leaking from
the unit
LED control panel
show some error
codes
E2- Room temperature faults
E3- Faulty coil temperature
E4- the coil is defrosted
E5- Unit faults

- 16 -
Remarks:
(1) The data may vary, please refer to the rating label placed on the product.
(2) The manufacture reserves the rights to change without notice.
SPECIFICATION
"
Model number
Cooling capacity
Power supply
Power consumption
Control
Working temperature
Noise level (dBA)
Max room size
Refrigerant
Dimension (WxDxH)
Net weight (lbs)
Safety compliance
TPAC-09K
9000 BTU
115V/60 Hz
Cooling: 1050W
Dehumidifying: 750 W
Digital LCD control panel / remote
controller
64°F~86°F
=< 52 (dBA)
150 sq.ft.
R22/12.35oz/0.77lb
20.8” x 12.5” x 28”
66 lbs
ETL
TPAC-12K
12000BTU
115V/60 Hz
Cooling: 1380 W
Dehumidifying: 750 W
Digital LCD control panel / remote
controller
64°F~86°F
=< 54 (dBA)
200 sq.ft.
R22/12.35oz/0.77lb
20.8” x 12.5” x 28”
68 lbs
ETL

- 17 -
謝謝您選購本產品! 我們希望這款移動式即時冷卻冷氣機,可以為您提升居家環境的舒適度.
建議您, 使用前, 請詳閱本使用說明書, 以確保產品可以為您創造出的最佳的工作效能.
以下的小提示, 可以幫助提升冷卻效果 .
在您使用時, 請參考實際情況並加以調整.
• 使用移動空調時, 請將廚房或浴室的熱源關閉
• 在建議使用的空間大小內使用本產品. 若使用的空間比我們所建議的還大, 您還是可以使用本產品, 只
• 當您離開房間時, 關掉電源,或是將溫度的設定設高一點, 這樣可以為您節省能源
• 定期檢查空氣瀘網是否太髒. 空氣瀘網太髒會堵塞空氣的流通, 降低冷效能 卻
• 不要將燈, 或任何會產生熱的物品放在空調機旁, 以免空調機感應到熱源, 持續運轉而損耗能源.
• 在使用空調機時, 將窗簾拉上, 減少太陽的照射.
• 空調機與四周牆壁至少保留20英吋(50公分)的距離.
空氣流通較好的地方, 冷卻效果會相對增加.
產 品 介 紹

- 18 -
為避免危險,
使用任何電器用品前, 請留意以下的使用說明:
1. 使用本產品前, 請詳閱本使用說明書
2. 為避免觸電與受傷, 請勿將電源線, 插座, 以及本產品浸泡在水裏或任何液體中, 也勿讓水或任何液體
流入本產品之電子零件, 以免受傷或損傷產品的功能.
3. 當本產品由孩童使用, 或者是使用時有孩童在旁邊, 請特別留意孩童的安全,小心使用. 由於本產品並未
為針對孩童特別設計防護措施, 因此建議您,勿讓孩童使用本產品.
4. 若電源線, 插座或產品本身有嚴重損傷, 請停止使用, 並連絡大同服務維修部門.
5. 請將產品直立放置. 不要倒置, 也不要水平放置, 以免損傷產品的功能
6. 在運送過程中, 產品可能會被水平放置, 使壓縮機內的油流入製冷銅管而影響製冷效能. 因此, 在第一
次使用時, 請將產品直立放置1 2 小時之後, 再插電運轉.
7. 請勿使用延長線, 或修改電源線. 也不要與其他電器用品共用一個插座.
8. 請勿用任何物品堵塞進風口與出風口. 出風口或入風口一定要保持空氣流通.
9. 離開房間, 或長時間外出, 請將關閉電源.
10. 不要讓寵物在空調機附近玩耍, 以免受傷. 也請勿將植物放置在空調機附近, 以免堵塞出風口或入風口.
11. 請勿將本產品放置於任何熱源旁邊, 比如: 瓦斯爐, 電爐或烤箱.
12. 請勿在浴室, 游泳池, 或是濕的地板上使用本產品.
13. 請勿直接拔插頭來啟動或是關閉電源.
14. 在進行清潔或搬運前, 請先拔掉電源插頭.
15. 請使用本產品製造商所建議的零件, 若使用其他零件, 可能會造成火災與傷害.
16. 請勿將眼睛, 臉, 皮膚, 或其他身體部位靠出風口太近, 或貼近出風口吹風太久.
17. 如果有任何異味或煙產生, 應立即斷電並停止使用, 並連絡維修中心.
18. 請勿在產品上噴灑任何易燃的液體或氣體.
19. 請勿站立或放置任何在產品上.
20. 請將產品直立放置, 並放置在平坦的地板上, 以免水箱的水溢出.
21. 若長時間不使用, 請將水箱中的水導引出來, 以免產生異味或發黴.
22. 不要將本產用於其他用途.
如果沒有遵守以上使用注意事項 ,
製造商不負任何相關責任.
製造商保留修改上述事項的權利, 不另行通知.
請妥善保存本手冊
本產品只限家庭使用
使 用 安 全 須 知
~

- 19 -
本產品附有LCDI (Leakage Current Detection and Interruption)電源線與插座. 當偵測到任何不正常的電流, 或是有
漏電的情形發生時
LCDI 插座會自動將電源切斷. 電源在切斷後並不會自動恢復, 除非手動將RESET的按鍵按
下.這樣的設計是為了防止漏電而造成的觸電, 火災或受傷. 因此, 為確保LCDI的插座工作正常, 請按照以下步
聚進行測試:
1. 將LCDI插頭插到牆上的插座, 此時, 插頭上的POWER燈會亮起
2. 按下在LCDI上的TEST按鍵. 此時, 電源應該會被切斷, 而插頭上的POWER燈會熄滅.
3. 按下在LCDI上的RESET按鍵. 電源即可恢復.
在測試的過程中
, 若發現LCDI插座不能正常工作, 請勿使用, 立即拔掉插頭並連絡專業的技術人員或維修中心.
若在使用產品的過程中, LCDI啟動並切斷電源, 此時請先檢查電源線是否有任何的損壞. 如果沒有, 則按下插頭
上的RESET按鍵, 以接通電源. 但如果電源仍舊被切斷, 請立即拔掉
插頭, 並連絡大同服務維修部門.
請特別留意:
1. 請勿將TEST和RESET按鍵當作電源開關來開啟或關閉電源.
2. 當空調機在運轉時, 請勿按TEST按鍵.
3. LCDI電源線與插座只限室內使用.
4. 定期檢查電源線. 如果有任何損傷, 請立即拔掉插頭, 停止
使用
LCDI 電 源 線 與 插 座
Test button
Reset button

This manual suits for next models
1
Table of contents
Other Tatung Air Conditioner manuals