TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
USER MANUAL
TE-3X48WW
PARLED
aqua

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
3.5--DMX512 SETTINGS......................................................................7.
PART4 USINGADMX512 CONTROLLER....................................9.
4.1--BASICADDRESSING.................................................................9.
4.2--CHANNELASSIGNMENT............................................................90.
4.3--BASIC INSTRUCTIONS FOR DMX512 OPERATION......................11.
PART3 DISPLAYPANELOPERATION.........................................6.
3.1--BASIC..........................................................................................6.
3.2--MENU..........................................................................................6.
3.6--PERSONALITY.............................................................................7.
3.8--SPECIAL SETTINGS.....................................................................8.
3.10--ACTIVATE THEPASSWORD ...................................................... 8.
PART1 PRODUCT(GENERAL)....................................................1.
1.1--PRODUCTINTRODUCTION.........................................................1.
1.2 PRODUCT FEATURES-- .................................................................1.
1.3 TECHNICAL SPECIFICATIONS-- .....................................................2.
1.4 PHOTOMETRIC DATA-- ..................................................................3.
1.5 SAFETY WARNING-- ......................................................................3.
PART2 INSTALLATION...............................................................4.
2.1--MOUNTING...................................................................................4.
2.3--SETTING UPWITH A DMX512 CONTROLLER.................................5.
2.3-1--DMX512 A DDRESSING WITHO UT IDADDRESSING.................... ..................5.
2.3-2--DMX512ADDRESSINGWITH IDADDRESS........................ ............... ...........5.
2.2--POWER CONNECTION..................................................................4.
3.3--EDIT STATICCOLOUR.................................................................7 .
PART5 APPENDIX......................................................................12.
5.1--TROUBLE SHOOTING...............................................................12.
5.2--MAINTENANCE.........................................................................13
.
3.4--RUN MODE.................................................................................. 7.
3.9-- ....................................................................... 8.WHITESSETTING
3.7--ID ADDRESS................................................................................7.
TABLE OF CONTENT
S

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
1.1 PRODUCT INTRODUCTION
This product is designed for indoor or outdoor use. Suitable applications includewash or
effect lighting for architectural, stage, theatre or road show applications. Direct input of
DMX512signal allowsthe units to becontrolled fromany DMX512 controller. Thisproduct
can beoperated as a single unit or in multiple unitsforlarge applications.
1.2 PRODUCT FEATURES
LED FIXTURE
1
*IP67protectionrating
*Linear / Nonlinear dimmer
* Strobe
*Uploadcustomparameterstoslavefixtures
*LEDdisplay
*Displaycontrol 'lock-out'
*DirectDMX512input
*Independent IDaddress
*Different whitecolorssetting
* 'Over-heat' protection
1PRODUCT (GENERAL)

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
1.3 TECHNICALSPECIFICATION
S
LED MODULE
Dimensions
LED MODULE:
Vo lt a g e
Rated Power
IP67 protection rating
Weig ht
LED/Un it
Output/LED
Co ol in g
IP
3W
Directair convection
335 x 300 x 235m m
9Kg
100~250V...50/60Hz
150W
2
Environment Tem perature -20 ~40℃℃
48pcs(12 x Cool white /36 xWarm white)
335mm
300mm
235mm
210mm

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
1.
4
PHOTOMETRIC DATA
3
COOL WHITE
COOL WHITE+WARM WHITE
WARM WHITE
3
1.5 SAFETY WARNING
IMPORTANT
【】
【
】
ALWAYSREADTHEUSERMANUALBEFOREOPERATION.
PLEASE CONFIRMTHATTHEPOWER SUPPLYSTATED ONTHE
PRODUCT ISTHESAMEAS THEMAINSPOWER SUPPLYIN YOUR
AREA.
●
●
●
●
●
●
●
●
●
●
This product must beinstalled by aqualified professional.
Alwaysoperate the equipment as described in the user manual.
A minimum distance of 0.5m must be maintained between the equipment and
combustible surface.
The productmustalways beplacedina wellventilatedarea.
Alwaysmakesurethattheequipment is installedsecurely.
DO NOT stand close to the equipment and stare directly into the LED light
source.
Alwaysdisconnect thepower supplybeforeattempting andmaintenance.
Always make sure that the supporting structure is solid and can support the
combined weight ofthe products.
The earth w ire mustalways be connected to theground.
Donottouchthe powercables ifyourhands arewet.
ATTENT ION
●
●
●
●
●
●
●
●
This product left the place of manufacture in perfect condition. In order to
maintain this condition and for safeoperation, the user must always follow the
instructions and safety warnings described in this user manual.
Avoidshakingorstrongimpacts toanypartof theequipment.
Make sure that all parts of the equipment are kept clean and free of dust.
Alwaysmake sure that the power connections are connected correct and
secure.
If thereis any malfunction of the equipment, contact your distributor
immediately.
Whentrans ferring the product, it is advisable to use the original packaging in
whichthe product left the factory.
Shields, lenses or ultraviolet screens shall be changed if they have become
damagedto suchanextentthat theireffectiveness is impaired.
The lamp(LED) shall be changed ifithas becomedamagedorthermally
deformed.
1
2
3
0
1
2
3
246 8 10Distanc e(m)
416 0 1022 533 257 204 LUX
15°
1
2
3
0
1
2
3
246 8 10D ista nc e( m)
876 0 2060 980 578 398 LUX
15°
1
2
3
0
1
2
3
2468
10Distance(m)
12160 3110 1494 890 575 LUX
15°

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
2.1 MOUNTING
HANGING
UPRIGHT
The fixture can be mounted in an upright or
sitting position using the supporting brackets.
The fixture can be mounted in a hanging position
using the supporti ng bracket. The bracket
should be secured to the mounting truss or
structure using a standard mounting clamp.
Please note that when hanging the unit a safety
cableshouldalsobe used.
@ 220V: 15 units may be connected in series
@120V: 7 units may be connected in series
The LED MODULEcan be mountedat any angleand inany
position. It is possible to further adjust the angle of the LED
MODULE using the tw o adjustment knobs located on the side of
the fixture.
2.2 POWER CONNECTIONS
4
Note:
1. Asthis fixture's DMX signal cable connection is Parallel connection, so if over 32 units to be
connected, then a DMX signal amplifier is needed.
2. If the signal cable is over 60m between the DMX512 controller and fixture or beween two
fixtures, then a DMX signal amplifier is needed as well.
2INSTALLATION

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
2.3 SETTING UP WITHADMX512
CONTROLLER
2.3-1 DMX512ADDRESSING WITHOUT IDADDRESSING
MODE)(Std.2
The figure above shows a simple DMX512
layoutwiththestartingaddress of thefirst
unit set at 1, with the second set at 7 and
so on... (Note that when used in this way,
the CH6 ID function must be inactive(CH6=0))
DM X 512
CON TRO LLE R
●
●
●
●
●
●
Connect the DMX512 controller to the units in series.
Eachunit has 6DMX channelsso the DMXAddressesshould increase by incrementsof
6(e.g. 1,7,13,19...)
The ID address has not been set so therefore whenusing the controller Ch6 must
be inactive ( CH6=0 ).
EachDMXAddress may beusedasmanytimesasrequired.
AnyDMXaddressintherange from001to512 may be used.
It is also possible to deactivate ID address selecting from the menu.
on the fixture
【】 【 】IDOFF Settings
2.3-2 DMX512ADDRESSINGWITH IDADDRESS MODE)(Std.2
Connect the DMX512 controller to the units in series
Eachunit has 11 DMX channels so the DMXAddresses should increase by incrementsof
6(e.g.1,7,13,19...)
EachDMXAddress may beusedasmanytimesasrequired.
Any DMX address inthe range from 001 to 512 may be used.
EachDMXaddress may carry up to 66 separate ID addresses.
should be set in the menu on each unit in ascending value s
(i.e. 1,2,3...)
ID addresses are accessible from CH6 on the DMX512 controller.
●
●
●
●
●
●
●
●
【】
【】 【 】
ID
ID On Settings
should be set in the menu oneach unit.
Example:
............
DMX Add r.1 DMX Add r.7 DM XAddr.13
DMX512
CONTROLLER
Example:
The figureabove showsa simple DMX layout
which has used three units at each DMXaddress.
Thethreeunits havedifferentIDaddresseswhich
allows theuser to collectivelycontrolthe whole
group ofunitsatthatDMXaddress bysetting
CH6 to 0, or to control each unit independently by
first selecting the DMX address and then by using
CH6 to locate the targetID address.
............
DMX Add r.1
ID A dd r.1 DM XAddr.1
ID Add r.2 DM X Ad d r.1
ID Addr.3 DMX Addr.7
ID Addr.1 DM XAddr.7
ID Addr.2 DMXAddr.7
ID Add r.3
5

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
3.1 BASIC
The LED fixture is mounted wit h a LCDdisplay and 4control buttons.
3
DISPLAY PANEL OPERATION
6
ENTER UP DOWN
MENU
enter the currentlyselected menu or
confirm thecurrent function value
scroll 'UP' through the menulist or increase
thevalueof the current function
scroll 'DOWN' throughthe menu listor decrease
thevalueofthe currentfunction
scroll through the main menu or return to
the mainmenu
MENU
ENTER
3.2 MENU
RUN d M X
SLAV
d(001~51 2)
DMX
ID
ID( 01~ 66)
SET UPLd
Id ON
OFF
STd.d
STd.2
STd.1
MENU
W(0~255)
C(0~255)
ST(0~20)
STAT
PERS
REST
STd.w
POW NORM
HIGH
KEY ON
OFF
WT01
WT02
WT07
CAL1
dIM1
dIM3
dIM2
dIM4
dIM OFF
W(0~255)
C(0~255)

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
7
3.3 EDIT STATIC COLOU
R
STATIC COLOUR【】
●【 】【 】
●【】Strobe
Combine and to create whites with different
color temperature
Set the value of the (0-20Hz)
WARM WHITE COOL WHITE
RUN【】
【】
【】
【】
Enter the modetoset working mode.
mode is for using the DMX512 controller to control t he fixtures.
mode is for Master -- Slave operation.
●
●
●
RUN
DMX
SLAV
3.4 RUNMODE
RUN DMX
SLAV
MENU
MENU
W(0~255)
C(0~255)
ST(0~20)
STAT
3.5 DMX512SETTINGS
DMX【】
【】DMX
●
Enter the modeto set theDMXADDRESS.
3.6 PERSONALITY
PERSONALITY【】
【】 【 】【 】
【】【】
Enter the modeto select DMXmode:
or .
●
PERS STd.w , STd.d ,
STd.1 STd.2
3.7 IDADDRESS
ID【】
【】ID
●
Enter the mode to set the IDADDRESS.
D(001~512)
DMX
MENU
ID
ID(01~66)
MENU
STd.d
STd.2
STd.1
PERS STd.w
MENU

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
Select to upload the customprograms from the current MASTER unit to
the SLAVE units.
In orderto activate theupload function the password must be entered.
Password is the sameas the main access password.
Whenuploading theMASTER and SLAVE units willbeblack out.
On successful uploading of the custom programs the MASTER and SLAVE units
willdisplayCool White.
In orderto reset custom modes to default values select .
Enter in order toallow/disallowID address function from the DMX512
controller.
Enter to choose the operation power mode or ,
when it is normal mode, the power consumption is about 90W, while un der high
mode, itis about 150W.
Enter to select dimmer modeand dimmer speed. When DIMMER is set to
, then RGBW and MASTER DIMMER are linear. The Dim 1/2/3/4 are speed
modes of the non linear dimmer , is the faster, while is the slowest.
The setting here does not react on the the mode.
【】
【】
【】
【】
【】 【 】【 】
【】
【】
【】 【】
【】 【 】
SETTING
UPLD
REST
ID
POW NORM HIGH
dIM
Off dIM1 dIM4
dIM STAG
●
●
●
●
●
●
●
●
●
●
3.9 WHITES SETTING
WT01
WT02
WT07
CAL1
W(0~255)
C(0~255)
MENU
KEY ON
OFF
MENU
3.
8
SPECIALSETTING
S
SET UPLd
Id ON
OFF
REST
POW NORM
HIGH
dIM1
dIM3
dIM2
dIM4
dIM OFF
MENU
CAL1【】
【】
【】【 】
【】
Enter the to select white color of different color temperature.
There are 7 pre-programmed White colors can be edited
by using & .
When DMX mode is , these7 whites will be showed onCH4.
●
●CAL1
Coolwhite Warmwhite
Std.2
KEYLOCK【】
【】
【】
【】【 】【 】【 】
KEY SET
UP DOWN UP DOWN
●
●
●
Enter the mode to select whether the accesspassword ison or off.
In orderto enter access password it is necessary tofirst press .
Accesspassword is + + + .
8
3.10 A CTIVATE THE PASSWORD

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
●Note:This product have three DMX512channel configuration:
and 【】【】
【】【】 Std.w , Std.d ,
Std.1 Std.2
4.1 BASICADDRESSING
●
●
●
Connect all of the units in series usingstandard DMX512 signal cableor the IP65 ratedcable
provided.
Set the DMX512 address in the menu.
It is possibleto havethe same DMXaddress orindependentaddresses for each fixture.
【】DMX
4.2 CHANNELASSIGNMENT
9
4
USING ADMX512 CONTROLLER
Std.w
1
2
0 255
CHANNEL FUNC TIONVALUE
0 255
Std.d
1
2
0 255
CHANNEL FUNC TIONVALUE
3
0 255
0 255
Std.1
1
2
0 255
CHANNEL FUNC TIONVALUE
0 255
WARMWHITE
COO LWHIT E
WARMWHITE
COO LWHIT E
MASTER DIMMER
MASTER DIMMER
WHITEMACRO

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
Std.2
10
1
2
0 255
CHANNEL FUNCTIONVALUE
3
0 255
0 255
N OFUNCTION
4
MASTER DIMMER
0 10
11
41
71
101
131
161
191
40
70
100
130
160
190
255
WHITE1: 3200K (Factory Calibrating)
WHITE2:3400K
WHITE3:4200K
WHITE4:4900K
WHITE5: 5600K (Factory Calibrating)
WHITE6:6500K
WHITE7:7200K
WHITES MA CRO
N OFUNCTION
0 9
10 255 1~20Hz
STROBE
5
ID ADDRESS
ID1~ID66
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
ID9
ID10
ID11
ID12
ID13
0 9
10 19
20 29
30 39
40 49
50 59
60 69
70 79
80 89
90 99
100 109
110 119
120 129
130 139
ID14
ID15
140 149
150 159
ID21210
ID66255
ID20
200 209
ID18
ID16
ID17
160 169
170 179
180 189
ID19190 199
WARMWHITE
COO LWHIT E
6

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
4.3
BASIC INSTRUCTIONS FORDMX512
OPERATION (STAGE1)
11
MASTER DIMMER
COOLWHITE & WARMWHITE SELECTION
STROBE
WHITE MACRO
IDADDRESSSELECTION
●
●
●
●
●
●
●
●
●
●
CH1 controls the intensityof the currently projected color
When the slider is at the highest position(255) the intensity of the output is the maximum
CH2 and CH3 control theintensity ratio of each of the WARM WHITE & COOLWHITE LEDs.
When theslider is at the highest position(255) the intensity of the color is the maximum.
CH2andCH3 canbecombined together tocreatewhites withdifferentcolor temperature.
CH 5 controls the strobe of CH1 to CH4
CH5 has priority over CH2, CH3 & CH4.
Ch4 allowuser to select 7 whites with different color temperature.
The 7 whites are took from the on Display panel.
CH6 is used to select thetarget ID address .
Each independent DMX address may have upto 66 independent ID addresses.
An ID address of 0 will activate all ID address locations.
●
●
【】CAL1

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
No disp lay
SITUATION CAUSE ACTION
5.1 TROUBLESHOOTING
1) Nopow erinput
2) Powerconnectionerror
3) Display damaged
4) Display boardICerror or powerinput
connectionerror or two board connection
error
5) Contrastdecay
,
,
1)Check powe r supply
2)Check powe r conne ction
3)Replace display
4)Checkthe IC and all theconnections
5)AdjusttheLCDcontrast
1) Display ICreverseinstall
2) Display IC damaged 1)CheckDisplay IC installation and quality
LED MODULE
on, but no con trol
from display
Displaynormal,
but no response
from buttons
1 ) Button s dama ged
2) Display ICdamaged 1)Rep lace b uttons
2)ReplaceDisplayIC
1) Signal C abl e error
2) Signal conncetionerror
3) The DMXsignal receiveIC damaged
4) DMX addresserror
No DMX signa l
1)Check all signalCables
2)Check all signal conncetion s
3)Checkthe DMXsignal receive IC
4)CheckDMX address
1) The heat sensor resistance ofLED board
error
2) The temperatureprotection circuiton the
display error.
W hen the surf ace
te mpe rature of the
unitexceed75 ,the
te mpe rature prote ction
no work.
℃
1) Replacetheheats ensorresistanc e.
2) Ch eck the tempera ture pro tection ci rcuit.
1) Ch eck LEDs joinin g
2) Ch eck lens installin g
1) LED not joining well
2) Lens not installingwell
Colormixing
uneven,withsplash
1) LED damaged
2) LED damaged orMainPCB
LEDsof thesame
colorare notlit 1) ReplaceLEDs
2) ReplacedamagedLEDor MainPCB
1)ReplacesavingIC1) Saving IC damaged
Manualandprogram
cannot save
12
5APPENDIX
1 ) Check driver current o f the pa rtial col or
LEDs onthe Driver PCB
2) Check LED quality
3)Reset tofactorydefaultsetting.
1) The currentof one ofthe colorgroupLEDs
is too strong or tooweak.
2) LED brightness not enough
Partial color
partial warm white,
partialcoolwhite
()

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
5.2 MAINTENANCE
19
123456
78910
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Frontcover
Rubber seal
Clear glass
Lens completedset
LED PCB
Heat sink
Bracket
Power connectionboard
Display PCB
Display protection metal plate
Safety chainboard
DriverPCB
POWER PCB(5V)
Powersupply (24V)l
No
ITEM

TE-3X48WW PARLED AQUA
Phonel : (1) 207-712-3004 http://www.te-lighting.com
L
N
J1 J2 J3
J4
LED
POWER
5V 0 V
-B
-B
0V
S
J3
十
一J2J2J2
J1
24V 0V
T P 2- 09 505
HXPEE
TP2- 09 505
HX P EE
5V
0V
AC 10 0V ~2 50 V
POWERIN
PO W E R O U T
DMXIN
DMXOU T
24 V
0V
POWER
J2
J1
J3
J2
屏蔽线
Connection Drawing
Table of contents
Popular Floodlight manuals by other brands

Chauvet
Chauvet Comet LED user manual

Probuilder
Probuilder 69911 instruction manual

Larson Electronics
Larson Electronics GL-4600-F-M-12I Instruction guide

Lithonia Lighting
Lithonia Lighting OFL1 Series installation instructions

Wayhom
Wayhom W1010A Assembly instructions

DNIPRO M
DNIPRO M DCL-200 Original instructions