Teledyne Summit Z3-16 User manual

Summit Z3-16
PCI Express Multi-Lane Exerciser
User Manual
PCIeProtocolSuitesoftwareversion7.34
Generated: May 29, 2015, 15:35

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual ii
TeledyneLeCroyProtocolSolutionsGroup
TrademarksandServicemarks
TeledyneLeCroy,CATCTrace,PETracer,Summit,Summit T3‐16,Summit T3‐8,Summit T34,Summit T28,
Summit T24,Summit Z3‐16,Summit T2‐16,Summit Z2‐16,andBusEnginearetrademarksofTeledyneLeCroy.
MicrosoftandWindowsareregisteredtrademarksofMicrosoftCorporation.
IntelandPentiumareregisteredtrademarksofIntelCorporation.
Allothertrademarksandregisteredtrademarksarepropertyoftheirrespectiveowners.
THESPECIFICATIONSANDINFORMATIONREGARDINGTHEPRODUCTSINTHISMANUALARESUBJECTTOCHANGE
WITHOUTNOTICE.ALLINFORMATION,EXAMPLESANDRECOMMENDATIONSINTHISMANUALAREBELIEVEDTOBE
ACCURATEBUTAREREPRESENTEDWITHOUTWARRANTYOFANYKIND,EXPRESSORIMPLIED.USERSAREFULLY
RESPONSIBLEFORTHEIRAPPLICATIONOFANYPRODUCTS.
THESOFTWARELICENSEANDLIMITEDWARRANTYFORTHEACCOMPANYINGPRODUCTARESETFORTHIN
INFORMATIONTHATSHIPPEDWITHTHEPRODUCTANDAREINCORPORATEDHEREINBYTHISREFERENCE.IFYOUARE
UNABLETOLOCATETHESOFTWARELICENSEORLIMITEDWARRANTY,CONTACTTELEDYNELECROYFORACOPY.
©2012TeledyneLeCroy,Inc.Allrightsreserved.
Thisdocumentmaybeprintedandreproducedwithoutadditionalpermission,butallcopiesshouldcontainthiscopyright
notice.
WEEEProgram
Teledyne LeCroy
3385 Scott Blvd.
Santa Clara, CA 95054

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual iii
TeledyneLeCroyCorporation
TEL: 800-909-7112 (USA and Canada)
TEL: 408-653-1260 (worldwide)

TeledyneLeCroyCorporation
iv SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual v
Contents
Chapter 1: Introduction...........................................................................................1
1.1 Exerciser Overview................................................................................................................. 1
1.2 Receiving Your Exerciser and the Optional PCI Express Test Platform ........................... 2
1.3 Unpacking the Exerciser and the PCI Express Test Platform ............................................ 2
1.4 Summit Z3-16 Exerciser ......................................................................................................... 2
1.5 Exerciser Features.................................................................................................................. 3
1.6 PCI Express Test Platform..................................................................................................... 3
1.7 PCI Express Test Platform Features..................................................................................... 4
1.8 Related Reference Documents.............................................................................................. 6
Chapter 2: Hardware Description ..........................................................................7
2.1 Exerciser System Components............................................................................................. 7
2.2 Host Machine Requirements ................................................................................................. 7
2.3 Summit Z3-16 Exerciser ......................................................................................................... 7
2.3.1 User Interface on the Summit Z3-16 Exerciser ................................................................................. 10
2.4 Environmental Conditions..................................................................................................................................10
2.4.1 Connectors........................................................................................................................................... 10
USB Type B Host Machine Connector .............................................................................................. 10
Ethernet Port ....................................................................................................................................... 10
In/Out Connector................................................................................................................................. 10
x16 PCIe Edge Connector .................................................................................................................. 10
2.4.2 LEDs ..................................................................................................................................................... 11
TRAIN (training) LEDs ........................................................................................................................ 11
Transmitter and Receiver LEDs......................................................................................................... 11
2.4.3 Bus LEDs.............................................................................................................................................. 11
2.5 PCI Express Test Platform 16x2.5GT/s / 16x5.0GT/s / 16x8.0GT/s................................... 11
2.5.1 Connectors........................................................................................................................................... 12
AC Power Connector .......................................................................................................................... 12

TeledyneLeCroy
vi SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
DUT PCIe x16 Connector.................................................................................................................... 12
The Summit Z3-16 Exerciser Power Connector ............................................................................... 12
Reference Clock In Connector........................................................................................................... 13
Reference Clock Out Connector........................................................................................................ 13
Summit Z3-16 Slot Connector............................................................................................................ 13
DUT Slot Connector ............................................................................................................................ 13
DUT Power Connector ........................................................................................................................ 13
Output Connectors ............................................................................................................................. 13
To Analyzer (15:8) Connector ............................................................................................................ 13
To Analyzer (7:0) Connector .............................................................................................................. 13
2.5.2 LEDs ..................................................................................................................................................... 13
DUT PRSN LED.................................................................................................................................... 13
Power Monitor LED ............................................................................................................................. 13
Aux DUT Power LED ........................................................................................................................... 14
2.5.3 Switches and Buttons ......................................................................................................................... 14
System Power On/Off Switch............................................................................................................. 14
SSC Switch .......................................................................................................................................... 14
Reference Clock Switch ..................................................................................................................... 14
DUT Power Switch .............................................................................................................................. 14
Reset Bus Button ................................................................................................................................ 14
2.6 PCI Express Test Platform for Summit™ Z3-16 Exerciser with
......................................................................................................CLKREQ# and SRIS Support14
2.6.1 Connections......................................................................................................................................... 16
DUT Under Test ................................................................................................................................... 17
DUT Reference Clocks, Summit Z3-16 Clocks, iPass Cable, Power Connection ......................... 17
Switches and LEDs ............................................................................................................................. 18
Reference Clock for DUT (SRIS), DUT Power Connectors, DUT Switches, DUT LEDs ................ 18
Clock Logic Diagram .......................................................................................................................... 19
2.7 PCI Express PXP-100B Test Platform 16x2.5GT/s / 16x5.0GT/s....................................... 20
2.7.1 Connections, LEDs and Switches...................................................................................................... 21
Clock Input Specification ................................................................................................................... 21
Clock Output Specification ................................................................................................................ 21
.............................................................................................................................................................. 21
Chapter 3: Installation ..........................................................................................23
3.1 Software Installation............................................................................................................. 23
3.1.1 Installing the PCIe Protocol Suite software ...................................................................................... 23
3.2 Setting Up the Summit Z3-16 Exerciser using a USB Connection................................... 24
3.3 Setting Up the Summit Z3-16 Exerciser using an Ethernet Connection ......................... 25
3.4 Adding Devices Manually .................................................................................................... 28

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual vii
TeledyneLeCroy
3.5 Setting Up the Summit Z3-16 Exerciser.............................................................................. 30
3.5.1 Connecting the Summit Z3-16 Exerciser Directly to a Host Machine............................................. 30
3.5.2 Connecting the Summit Z3-16 Exerciser to the PCI Express Test Platform 16x2.5GT/s / 16x5.0GT/s
/ 16x8.0GT/s................................................................................................................................................... 31
Chapter 4: Traffic Generation ..............................................................................33
4.1 Theory of Operation ............................................................................................................. 33
4.1.1 Overview............................................................................................................................................... 33
4.1.2 Starting Point ....................................................................................................................................... 34
4.2 LTSSM Control...................................................................................................................... 34
4.2.1 Link Speed Control.............................................................................................................................. 35
4.2.2 Link Width Control .............................................................................................................................. 35
4.2.3 Link State Control................................................................................................................................ 35
4.2.4 LTSSM Arc Tests ................................................................................................................................. 36
4.2.5 LTSSM Log........................................................................................................................................... 36
4.3 Exerciser Control Bar........................................................................................................... 37
4.4 Generating Traffic................................................................................................................. 39
4.5 Script Execution ................................................................................................................... 40
4.6 Creating a Traffic Generation File ....................................................................................... 41
4.6.1 Exporting a CATC Trace to a Traffic Generation File.......................................................................41
4.6.2 Saving a Script to a New File.............................................................................................................. 42
4.6.3 Creating a New Empty Generation File ............................................................................................. 43
4.7 Generation Options Dialogs Overview ............................................................................... 43
4.7.1 Opening the Dialog.............................................................................................................................. 43
Dialog Layout ...................................................................................................................................... 44
4.7.2 General ................................................................................................................................................. 44
4.7.3 Link ....................................................................................................................................................... 46
4.7.4 Phy Parameters ................................................................................................................................... 48
4.7.5 Integrity ................................................................................................................................................ 52
4.7.6 Flow Control......................................................................................................................................... 55
4.7.7 Transactions Device Emulation ......................................................................................................... 57
4.7.8 Transactions Host Emulation............................................................................................................. 58
4.7.9 Transactions Fast Memory Completer .............................................................................................. 60
4.7.10 Transactions: Enable Precision Time Management (PTM)............................................................ 63
Enable PTM.......................................................................................................................................... 63
4.7.11 Low Power.......................................................................................................................................... 64
4.8 Generating Traffic: Set Generation Options ...................................................................... 66
4.9 Generating Traffic: Prepare Traffic Generation ................................................................. 66
4.10 Generating Traffic: Begin Traffic Generation................................................................... 67
4.11 Editing Generation Files with the Script Editor ............................................................... 69

TeledyneLeCroy
viii SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
4.11.1 Script Editor Toolbar......................................................................................................................... 70
4.11.2 Script Edit Window............................................................................................................................ 71
Syntax Highlighting ............................................................................................................................ 71
Tooltips ................................................................................................................................................ 71
Outlining .............................................................................................................................................. 71
Text Editing Commands ..................................................................................................................... 71
Synchronized Scrolling with the CATC Trace Window ................................................................... 72
4.11.3 Command Properties Window ......................................................................................................... 72
4.11.4 Script Editor File Tabs ...................................................................................................................... 74
4.11.5 Script Editor Error Log...................................................................................................................... 74
4.11.6 View Options Menu ........................................................................................................................... 74
Chapter 5: Macros.................................................................................................77
5.1 Macros ................................................................................................................................... 77
5.1.1 Default Macros: Connect and Disconnect ........................................................................................ 77
5.1.2 Connect Macro..................................................................................................................................... 78
5.1.3 Disconnect Macro................................................................................................................................ 78
5.1.4 Adding New Script Macros ................................................................................................................. 78
Using the Generation Macros Dialog ................................................................................................ 78
Adding Script Files to the GenScriptMacros Directory ................................................................... 80
5.1.5 Modifying Script Macros..................................................................................................................... 80
5.1.6 Changing the Order of Macro Icons on the Status Bar.................................................................... 80
5.1.7 Deleting User-Defined Script Macros ................................................................................................ 82
5.1.8 Restoring the Default Appearance of the Connect and Disconnect Icons .................................... 82
Chapter 6: Configuration Space ..........................................................................83
6.1 Configuration Space Editor ................................................................................................. 83
6.2 Launching the Configuration Space Editor........................................................................ 83
6.2.1 Configuration Space Files .................................................................................................................. 83
6.2.2 Editing .................................................................................................................................................. 84
6.2.3 BARs Setup.......................................................................................................................................... 87
6.3 Configuration Read and Write ............................................................................................. 88
6.4 Expansion ROM Setup .........................................................................................................88
Chapter 7: Address Spaces .................................................................................91
7.1 Memory/IO Space Editor ......................................................................................................91
7.2 Memory Regions for Host Emulation.................................................................................. 92
7.3 Using StoreData in Device Mode for Z3 Scripting ............................................................. 92

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual ix
TeledyneLeCroy
Chapter 8: Updates and Licensing ......................................................................97
8.1 Updating the Exerciser......................................................................................................... 97
8.2 License Keys......................................................................................................................... 97
8.3 License Information.............................................................................................................. 98
Appendix A: Configuration Space Decoding .....................................................99
A.1 Mandatory Definitions ......................................................................................................... 99
A.2 Mandatory Module Functions ............................................................................................. 99
A.2.1 DecodeRegister(offset) ...................................................................................................................... 99
A.2.2 GetSize() ............................................................................................................................................ 100
A.3 Configuration Register Types........................................................................................... 100
A.4 Primitives............................................................................................................................ 100
A.5 Helper File........................................................................................................................... 101
Appendix B: NVMe Drive Emulation..................................................................103
B.1 NVME Drive Emulation in Windows 7 .............................................................................. 103
B.2 NVME Drive Emulation in Ubuntu Linux 14.10 and Linuxv3.1-rc4 ................................ 107
B.2.1 Hardware Setup for Test Equipment............................................................................................... 108
Appendix C: China Restriction of Hazardous Substances Table...................117
Appendix D: How to Contact Teledyne LeCroy................................................119
Index:.................................................................................................................. 121

TeledyneLeCroy
xSummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual 1
Chapter1
Introduction
TheTeledyneLeCroySummitZ3‐16Exerciser™isanadvancedGen1/2/3PCIExpress
verificationsystemcapableofgeneratingtrafficupto16lanesat8GT/srates.Itblends
sophisticatedfunctionalitywithpracticalfeaturestospeedthedevelopmentof
PCI Express™IPcores,bridges,switches,add‐inboards,andsystems.
ThisusermanualdescribestheinstallationandoperationoftheSummitZ3‐16Exerciser.It
includesadescriptionandexamplesoftheapplication.
ItalsodescribestheinstallationandoperationofthePCIExpressTestPlatform16x2.5GT/s
/16x5.0GT/s/16x8.0GT/swhichcanbepurchasedoptionally.
1.1 Exerciser Overview
TheSummitZ3‐16isTeledyneLeCroy’sfourthgenerationexerciser(trafficgenerator),a
criticaltestandverificationtooltoassistengineersindevelopingandimprovingthe
reliabilityoftheirsystems.ItaddssupportforPCIExpressattheGen3datarateof8GT/s.
ForsystemtestingtheSummitZ3canbeusedinadeviceemulationmode,wherethe
SummitZ3isdirectlypluggedintoaSystemUnderTest.Hence,thesetupisquickand
easy.
FordevicetestingtheSummitZ3isusedincombinationwiththePCIExpressTestPlatform
16x2.5GT/s/16x5.0GT/s/16x8.0GT/swhichprovideshostemulationcapabilitiesfor
SummitZ3.ThePCIExpressTestPlatformhastwoslots,onefortheSummitZ3‐16
ExercisercardandtheotherfortheDUT(DeviceUnderTest).Optionally,forGen1and
Gen2hostemulation,theSummitZ3canbeusedwiththepassiveTeledyneLeCroyPXP‐
100backplane.
TheSummitZ3‐16buildsontheextensiveprogrammingandverificationtestlibraries
establishedforTeledyneLeCroy’sPETrainer™andSummitZ2‐16PCIExpressExercisers,
andprovidestheuseracompletesuiteoftestcapability,includingtheabilitytotest
productstothePCIExpress3.0specification.WhenusedincombinationwiththeSummit
T3‐16ProtocolAnalyzer,engineershaveacompletetestanddevelopmentenvironment
forPCIExpressGen3relatedwork.

TeledyneLeCroy ReceivingYourExerciserandtheOptionalPCIExpressTestPlatform
2 SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
1.2 Receiving Your Exerciser and the Optional PCI Express Test
Platform
TheSummitZ3‐16ExercisercanbeorderedeitherwithorwithoutthePCIExpressTest
Platform.YoucanusetheSummitZ3‐16ExercisercarddirectlyinasystemusingtheAC
adaptertopowerthecard.IfyoupurchasedthePCIExpressTestPlatform,youcanuse
theSummitZ3‐16ExerciseronthePCIExpressTestPlatformintheprovidedslot.Inthis
casethePCIExpressTestPlatformsuppliespowertotheSummitZ3‐16Exerciser.
TheSummitZ3‐16Exerciserpackageincludesthefollowingcomponents:
SummitZ3‐16Exerciseridentifiedinthepackinglist
SummitZ3‐16ExerciserQuickStartGuide
USBA‐B2.0cable,1.8meter
Ethernetcable,10feet
ACAdapter
InstallationDVD‐ROMwithsoftwareanddocumentation
ThePCIExpressTestPlatform16x2.5GT/s/16x5.0GT/s/16x8.0GT/spackageincludesthe
followingcomponents:
PCIExpressTestPlatform16x2.5GT/s/16x5.0GT/s/16x8.0GT/sidentifiedinthe
packinglist
PowercableforSummitZ3
AUXpowercablesforDUT
ACpowercord
1.3 Unpacking the Exerciser and the PCI Express Test Platform
Inspectthereceivedshippingcontainerforanydamage.Unpackthecontainerand
accountforeachofthesystemcomponentslistedontheaccompanyingpackinglist.
Visuallyinspecteachcomponentforabsenceofdamage.Intheeventofdamage,notify
theshipperandTeledyneLeCroyCorporation.Retainallshippingmaterialsforshipper’s
inspection.
1.4 Summit Z3-16 Exerciser
TheTeledyneLeCroySummitZ3‐16ExerciserisacriticalPCIetestandverificationtool
intendedtoassistengineersinimprovingthereliabilityoftheirsystems.ItisaGen3PCI
Express16‐laneadvancedExercisersystemthatcanemulatePCI Expressrootcomplexes
ordeviceendpoints.YoucantestPCI ExpressIPcores,semiconductors,bridges,switches,
andsystems.

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual 3
ExerciserFeatures TeledyneLeCroy
1.5 Exerciser Features
TheExerciserhasthefollowingfeatures:
Bidirectionalx1‐x16,2.5GTsto8.0GTsgenerationsupportforaccurategenera‐
tionofPCIExpressbustraffic.
Host/DeviceEmulationSupportforallowingdesignandstresstesting.
LinkTrainingandStatusStateMachine(LTSSM)TestingtoexerciseLTSSMstate
transitionsforverification.
ThelatestZ3TrainersupportsCLKREQ#signalthatallowsforL1Substratetesting.The
olderversionsoftheZ3Trainerdonothavethiscapability.
Figure 1.1: Summit Z3-16 Exerciser Front View.
Thedimensionsofthemainboardare16.8x13.3cmor6.6"x5.25".
1.6 PCI Express Test Platform
ThePCIExpressTestPlatform16x2.5GT/s/16x5.0GT/s/16x8.0GT/sisaconvenient,
powerfulandflexiblePCIExpressTestPlatformforPCIExpressdevicesatdataratesupto

TeledyneLeCroy PCIExpressTestPlatformFeatures
4 SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
8GT/sandlanewidthsuptox16.ItcanbeusedinconjunctionwiththeSummitZ3‐16to
createaDUTenvironment.
1.7 PCI Express Test Platform Features
ThePCIExpressTestPlatformhasthefollowingfeatures:
ThePCIExpressTestPlatformaccessorytotheSummitZ3‐16Exerciserallows
testinganddebuggingofthePCIExpresscardsbyprovidinghostemulation.
ThePCIExpressTestPlatformsupportsPCIeratesupto8GT/s.
Lanewidthsofx1,x2,x4,x8andx16aresupported.
MechanicalsupportandpowerisprovidedforboththeSummitZ3‐16Exerciser
andthedeviceundertest(DUT).
FlexibleReferenceClockoptions.
ThePCIExpressTestPlatformprovidesaPCIeclock.Clockingwithorwithout
SSC(SpreadSpectrumClocking)canbeselected.Additionally,anexternal
clockcanbeprovidedthroughaSMAconnector.
PowerON/OFFfortheDUT.
DUTpowercontrol
DUTpowercanbeswitchedoffwithoutpoweringPCIExpressTestPlatform
off.
ThelatestversionoftheTestPlatformsupportsSRISandCLKREQ#.Older
versionsoftheTestplatformdonothavethesecapabilities.
ReviewtheQuickStartGuideforyourproducttolearnhowtoproperly
configuretheplatform.

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual 5
PCIExpressTestPlatformFeatures TeledyneLeCroy
Figure 1.2: PCI Express Test Platform 16x2.5GT/s / 16x5.0GT/s / 16x8.0GT/s.

TeledyneLeCroy RelatedReferenceDocuments
6 SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
1.8 Related Reference Documents
Foradditionalinformationrefertothefollowingdocuments:
1. PCIeProtocolSuite/TrainerAutomationManual
2. PETrainerScriptingLanguageReferenceManual
3. QuickStartGuides:
SummitZ3‐16PCIExpressExerciser
PCIExpressTestPlatform16x2.5GT/s/16x5.0GT/s/16x8.0GT/s
PCIExpressTestPlatformforSummit™Z3‐16ExerciserwithCLKREQ#andSRIS
Support
SummitZ3‐16PCIExpressExerciserwithCLKREQ#support

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual 7
Chapter2
Hardware Description
ThischapterdescribesthehardwarefortheSummitZ3‐16ExerciserandthePCIExpress
TestPlatform.
2.1 Exerciser System Components
Theexerciserhasthefollowingcomponents:
SummitZ3‐16™Exercisercard
x16tox1EdgeAdapter
x16tox4EdgeAdapter
x16tox8EdgeAdapter
PCIeProtocolSuitesoftwareprogramDVD‐ROM
2.2 Host Machine Requirements
TheSummitZ3‐16Exerciserconnectstoahostmachine.Pleaseconsultthereadmefileon
theinstallationDVDforthelatesthostmachinerequirements.
2.3 Summit Z3-16 Exerciser
TheSummitZ3‐16isamulti‐lanePCI ExpressExerciser(seeFigure 2.3onpage 8)designed
toassistengineersinimprovingreliabilityoftheirsolutionsandprovidingadvanced
capabilitiesforstressandcompliancetesting.
AllmodelsoperateasstandaloneExerciserscapableofgeneratingandrespondingtoall
typesofPCI Expresstransactions.Exercisersalsohavetheabilitytocreateprotocol
variationsandanomalies.Usersmaycreatecornercaseandstresstestscenariosto
evaluatetherobustnessoftheirsolutions.Byutilizingtheerrorinjectionfeature,
engineerscancreateworst‐casePCI Expresstrafficscenariosallowingthemtovalidatethe
errorhandlingcapabilitiesoftheirsolutions.
WhenusedinconjunctionwithanAnalyzer,suchastheTeledyneLeCroySummitT3‐16,a
completeexperttestandanalysissystemiscreated.Thisintegratedsolutiondelivers
trafficgenerationandprotocolanalysistoassistdeveloperswithearlyvalidationof
designscompliancetestpreparationwitherrorinjectionandstresstesting.

TeledyneLeCroy SummitZ3‐16Exerciser
8 SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
DeviceEmulationisastandardfeatureandhostemulationisavailablethroughthe
optionalPCIExpressTestPlatform16x2.5GT/s/16x5.0GT/s/16x8.0GT/s.
WARNING: Therearenouserserviceableparts.ForservicingpleasecontactCustomer
SupportatTeledyneLeCroy.
Figure 2.3 Summit Z3-16 Exerciser Front View.

SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual 9
SummitZ3‐16Exerciser TeledyneLeCroy
Figure 2.4 Summit Z3-16 Exerciser Rear View Showing the UI with LEDs.
TheSummitZ3‐16isastand‐alonePCI ExpressExerciserthatcancontrolLTSSM,theData
LinkLayerandtheTransactionLinkLayertosendandreceivepacketstotransferthedata.
TheSummitZ3‐16canestablishthelinkfromx1throughx16lanesystemandchange
speedfromGen1,Gen2andGen3toexerciseLTSSMStateTransitionsforverification.
2.3.1 User Interface on the Summit Z3-16 Exerciser
TheSummitZ3‐16bracketcontainsthefollowinginterfacecomponents:

TeledyneLeCroy EnvironmentalConditions
10 SummitZ3‐16PCIExpressMulti‐LaneExerciserUserManual
PowerOn/OffLED
Powersocketforthe12VDCPowerConnector
Powerrequirementis100‐240VAC,47‐63HzuniversalinputforACAdapter
whichisincluded
USBTypeBHostMachineConnector
Ethernetport
2.4 Environmental Conditions
Theenvironmentalconditionspecificationsare:
Operatingrangefrom0to40C(32to104F),0to90%humidity,non‐con‐
densing
Storagerangefrom‐10to80C(‐4to176F)
WARNING: SincetheelectricalcomponentsontheSummitZ3‐16cardareexposed,please
usestandardESDpracticeswhenhandlingtheboard;otherwise,itcouldbe
damaged.
2.4.1 Connectors
USB Type B Host Machine Connector
ThisconnectorlinkstheSummitZ3‐16Exercisertothehostmachineforthepurposeof
downloadinggenerationscriptsandcontrollingthebehavioroftheExerciser.
Note: UseeitherUSBorEthernet,notboth.
Ethernet Port
A10/100/1000baseTEthernetconnectortothehostmachineisprovided.GIGE
ConnectivityallowsconnectiontoanEthernetnetwork.ThisconnectorlinksanExerciser
tothehostmachineforthepurposeofdownloadinggenerationscriptsandcontrolling
thebehavioroftheExerciser.
Note: UseeitherUSBorEthernet,notboth.
In/Out Connector
Thisisforfutureuse.
x16 PCIe Edge Connector
Thex16PCIeEdgeconnectorcanbeadaptedtox8,x4orx1slotsthroughtheuseofa
CardReducerEdgeAdapter.
Table of contents
Other Teledyne Computer Hardware manuals
Popular Computer Hardware manuals by other brands

OWC
OWC Mercury Elite Pro Dual Assembly manual & user guide

HP
HP E2465A PowerPC 604 PGA user guide

Kontron
Kontron CI5TTV Series user manual

Carel
Carel LonWorks PCO20000F0 quick start guide

Elo TouchSystems
Elo TouchSystems E066330 Quick installation guide

Alphacool
Alphacool GPX-A 380-M05 instruction manual

Moxa Technologies
Moxa Technologies CP-602U-I user manual

ekwb
ekwb EK-FC 5970 INSTALLATION AND MOUNTING MANUAL

SilverStone
SilverStone SST-ECM22 instruction manual

Texas Instruments
Texas Instruments UCC217 QDWEVM-054 Series user guide

EK-Quantum
EK-Quantum Vector RX 6800/6900 D-RGB - AMD Radeon... user guide

Supero
Supero CSE-SATA-813L user guide