2
ECAN | Wiki
Table of Contents
Table of Contents .............................................................. 2
Know your device .............................................................. 3
Pinout ........................................................................................... 4
Wiring scheme .................................................................. 5
Set up your device............................................................. 6
Characteristics .................................................................. 7
Dimensions................................................................................... 7
Mounting recommendations............................................... 8
Safety information............................................................. 9
Warranty..........................................................................10
Warranty Disclaimer ................................................................... 10

4
ECAN | Wiki
Pinout
Table 1 ECAN01 4 pin socket pinout
Pin number
Pin name
Description
1
CAN L
(Blue) Connect to CAN L input of
CAN BUS converter
2
CAN H
(White/Blue) Connect to CAN H
input of CAN BUS converter
3
VCC
(Red) Power supply (+6-30 V DC)
4
GND (-)
(Black) Ground pin (10-30) V DC (-)
Figure 2 ECAN01 socket pinout

6
ECAN | Wiki
Set up your device
How to insert CAN wires into contactless reader ECAN01
1. Gently open ECAN01 cover using plastic pry tool from both sides.
2. Insert CAN wires as shown in figure 5. Please make sure that
correct slots are used (CAN High/CAN Low).
3. Gently close the device.
4. Device is ready-to-use.
Figure 4 Opening the cover
Figure 5 Inserting CAN bus
wires
Figure 6 Closing the cover
Figure 7 Device is ready to
use

7
ECAN | Wiki
Characteristics
Table 2 technical features
Characteristic description
Value
Min.
Typ.
Max.
Unit
Supply Voltage
Supply voltage (recommended operating
conditions)
+10
+12
+30
V
CURRENT CONSUMPTION
Working mode
6.9
mA
Stand-by mode
1.2
mA
OPERATING TEMPERATURE
Operating temperature
-25
+85
°C
PROTECTION
Internal resettable fuse (max 33 V)
750
mA
Dimensions
•Dimensions 39,8 x 18 x 16,7 mm
Figure 8 Dimensions

8
ECAN | Wiki
Mounting recommendations
•Connecting wires
▬Device should be connected by following a connection scheme,
which includes program number and CAN bus wires location. It will
be provided on request by Teltonika technical support.
▬In order to locate CAN bus wires, any twisted pair in the vehicle
should be checked especially on OBD, ICM (Instrument Cluster
Module) and ECU.
▬Wires should be connected while the module is not plugged in.
▬Wires should be fastened to stable wires or other non-moving
parts. Any heat emitting and/or moving objects should be kept
away from the wires.
▬If the wires are placed in the exterior or in places where they can
be damaged or exposed to heat, humidity, dirt, etc., additional
insulation should be applied and the wires should not be loose.
▬Wires cannot be connected to the board computers or control
units.
•Connecting power source
▬Be sure that after the car computer goes to sleep mode, power
would still be available on power wires. Depending on the car
model, this may happen in 5 to 30 minutes period.
▬When the module is connected, measure the voltage again to
make sure it did not decrease.
▬It is recommended to connect to the main power cable in the fuse
box.
•Connecting ground wire
▬Ground wire is connected to the vehicle frame or metal parts that
are fixed to the frame.
▬If the wire is fixed with the bolt, the loop must be connected to
the end of the wire.
▬For better contact scrub paint from the spot where loop is going
to be connected.

9
ECAN | Wiki
Safety information
This message contains information on how to operate ECAN01 safely. By
following these requirements and recommendations, you will avoid
dangerous situations. You must read these instructions carefully and follow
them strictly before operating the device!
•The device uses SELV limited power source. The nominal voltage is +12
V DC. The allowed voltage range is +10..+30 V DC.
•To avoid mechanical damage, it is advised to transport the device in an
impact-proof package.
•When connecting the power connector wires to the vehicle, the
appropriate jumpers of the vehicle power supply should be
disconnected.
•Before unmounting the device from the vehicle, the power connector
must be disconnected.
Do not disassemble the device. If the device is
damaged, the power supply cables are not insulated
or the insulation is damaged, DO NOT touch the device
before unplugging the power supply.
The device must be connected only by qualified
personnel.
The device must be firmly fastened in a predefined
location.
The programming must be performed using a PC with
autonomic power supply.
Installation and/or handling during a lightning storm
is prohibited.
The device is susceptible to water and humidity.

10
ECAN | Wiki
Warranty
TELTONIKA guarantees its products to be free of any manufacturing
defects for a period of 24 months. With additional agreement we
can agree on a different warranty period, for more detailed
information please contact our sales manager.
Contact us teltonika.lt/company/contacts
If a product should fail within this specific warranty time, the product
can be:
•Repaired
•Replaced with a new product
•Replaced with an equivalent repaired product fulfilling the same
functionality
•TELTONIKA can also repair products that are out of warranty at
an agreed cost.
Warranty Disclaimer
TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY
PERSONS WITH TRAINING AND EXPERIENCE. ANY OTHER USE
RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN
AND ALL IMPLIED WARRANTIES NULL AND VOID AND SAME
ARE HEREBY EXCLUDED. ALSO EXCLUDED FROM THIS
LIMITED WARRANTY ARE ANY AND ALL INCIDENTAL OR
CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO,
LOSS OF USE OR REVENUE, LOSS OF TIME, INCONVENIENCE
OR ANY OTHER ECONOMIC LOSS.
More information can be found at teltonika.lt/warranty-repair
Table of contents
Other Teltonika Adapter manuals