FORM TPM1-EG1 (516)
TEMPMASTER 9
Master OmniElite Modulating HGRH option redirects the hot refrigerant gas leaving the
compressor to a separate coil downstream of the evaporator cooling coil, in effect provid-
ing reheat function (at no additional energy cost) for the air off the cooling coil. Educational
facilities, places of worship, restaurants, gymnasiums, and museums/learning centers are
all applications that benefit from the enhanced humidity control of TempMaster OmniElite
Modulating HGRH rooftop option.
The TempMaster OmniElite unit IPU controller energizes the HGRH operation when de-
humidification is needed, controlling the modulating valve, reheat coil, and cooling coil to
maintain the consistent levels humidity and temperature control needed by the building
space. This operation adds sensible heat to the supply air being delivered to the space
and allows the evaporator cooling coil to operate at a lower temperature, removing excess
moisture without overcooling the conditioned space.
Altitude – (1000 feet up to 6000 feet) If your product's destination is above sea level,
please select current altitude. Due to air density, corrections are needed to outline the cor-
rect unit performance. The altitude will affect cooling and gas heating performance. It will
not affect other heating options, such as electrical, hot water, or steam coils. Most likely, in
order to maintain desired static pressures at highter altitudes, higher RPM moters may be
required.Atthesametime,lowerheatmayberequiredduetoadecreaseinairdensity.
Highaltitudeheatingoptionswillberequiredforaltitudehigherthan2000feetabovesea
level. All calculations are for the U.S. territory.
Electric Resistance Heat – For applications where electric heat is desired, a slip-in elec-
tric resistance heat element is available in sizes from 40-150 kW depending on the rooftop
model size. The number of stages varies by size and voltage, but all have a minimum of
two stages of capacity. Units with electric heat are ETL listed.
Hot Water Heat – For applications where hot water is available for heating, a hot water
heating coil is available. A range of coil fin count selections are available to properly size
the heating for the application. Units with hot water heat are ETL listed. See Hot Water/
Steam Coil Connection Locations on page 57, Table 2 on page 21, and Table 11 on
page 31 for more information.
Steam Heat – For applications where steam is available for heating, a steam heating coil
is available. A range of coil fin count selections are available to properly size the heating
for the application. Units with steam heat are ETL listed. See Hot Water/Steam Coil Con-
nection Locations on page 57, Table 2 on page 21, and Table 12 on page 31 for
more information.
POWER OPTIONS
Single-point supply with terminal block – This configuration is standard, and includes
three terminals for the incoming 3-phase power and is the standard configuration for the
TempMaster OmniElite product. It includes the enclosure, terminal-block, and intercon-
necting wiring to the compressors, heater and furnace controls, all fans, etc. In this con-
figuration,coderequiresthatameansofdisconnect(notprovided)mustbeinstalledat
thesitewithinline-of-sightoftheequipment.
Single-point supply with non-fused disconnect switch – This option is the same as
the single-point with terminal block option except it includes a unit-mounted through-the-
door manual non-fused disconnect switch with an external, lockable handle (in compli-
ance with Article 440-14 of N.E.C.). This option provides a means to isolate the unit power
voltage for servicing. Others must supply separate external fusing which must comply with
the National Electric Code and/or local codes.