Temtop C1 User manual

C1
Air Quality Monitor
User Manual

Carbon dioxide(CO2) is a colorless and odorless gas usually derived
from the breath of humans and animals. High CO2concentration
means that fresh air or ventilation is required; otherwise, it may
cause problems such as drowsiness, dizziness, loss of attention,
and cognitive impairment.
Temperature &Humidity may often be ignored. However, they do have
a significant impact on an individual's well-being, comfort, health
and safety, as well as your property. High Humidity may lead to an
increase in household air pollutants, especially the biological contaminants
such as molds, bacteria, viruses, and dust mites; cold, low Humidity
may cause nosebleeds, skin and respiratory irritations, dyspnea, static
electricity, etc.

Do not expose the detector to heavily contaminated environments for long
periods, as this can damage the sensor.
Do not use the detector for long periods in environments with a strong, irritating
smell to ensure accurate measurements.
Do not dismantle the unit yourself. In the event of a defect, contact your dealer
instead, who will liaise with the service center and, if necessary, send the
device in for repair.
Children should only use this device under adult supervision. Keep packaging
materials, such as plastic bags and plastic wrap, out of the reach of children
as they present a choking hazard.
If the battery level shows , please charge the detector in time to avoid
being aected during use (it can also recharge when switched o).
This product is intended for monitoring the health of the indoor environment
only and should not be considered a professional measurement tool.
★
★
★
★
★
★

Buzzer status CO2level
Temperature &Humidity level Battery level &Charging status
Work mode
Health level display area
Magnetic back Vents

Mode button Power button USB port
CO2detection port
Bracket
Temperature &Humidity detection port

CO2
Measuring range: 400-5000ppm
Resolution: 1ppm
Accuracy: ±(40ppm +5%)
(400-2500ppm)
C1
Model
Temperature*
Humidity
Measuring range: 0-99%RH
Resolution: 0.1%RH
Accuracy: ±3%RH
Measuring range: -10-60°C (14-140°F)
Resolution: 0.1°C (-9.9-70°C)
Accuracy: ±0.5°C
When charging the product, the temperature will be ± 0.5 error and will be recovered in
about 10 minutes after the charging is completed.
When the temperature measurement environment suddenly changes, and the temperature
dierence is significant, it takes 3 to 5 minutes of adaptation time.

-10-60°C/0-90%RH
When the product is charging, the data will keep refreshing every 5 seconds.
Note: The above data are from Temtop Laboratory.
About 70 days
About 30 days
Power-saving mode (Sampling interval 10 min)
Performance mode (Sampling interval 1 min)
Segment code screen 3.3 inches

Power-saving mode (Sampling interval 10 min)
Performance mode (Sampling interval 1 min)
Power button
1 )
Press 3s to turn on/o the C1 monitor.
2 )
Short press to turn on/o the alarm.
Buzzer switch Icon
Displayed--buzzer sound on the device is turned on;
Disappears--the buzzer sound is turned o.

The C1 has two working modes, and you can switch the working mode by pressing the
mode button after powering on.
Mode display
1 )Short press to switch between the
work mode (2 dierent types)
2 )Long press 2s to switch between the
temperature unit ( )
Performance mode (Sampling interval 1 min)
CO2sensor works every 1 minutes.
CO2sensor works every 10 minutes.
Note: If the temperature and humidity change is high, it will be refreshed once in 5 seconds;
if the temperature and humidity change is low, it will be refreshed once in 10 seconds.
Mode button
Power-saving mode (Sampling interval 10 min)

2. C1 monitoring function
1 ) When the battery is displayed as empty, please charge it in time, and the charging icon will be
displayed when charging.
2 ) When the battery power is extremely low, the battery icon will flash 3 times and the shut down.
Power display
Charging icon
USB interface

3. CO2calibration
Switch on the detector in an outdoor ventilated area; Long press the and to enter the
calibration state, the CO2title on the screen flashes, the CO2 display area starts to count down
200 seconds; the countdown ends, and the calibration is complete.
During manual calibration, the monitor must be exposed to fresh outdoor air (approx. 400
ppm of CO2) at least 1 meter away from people or animals.
In calibration mode, press the button to stop calibration mode.
Please ensure the power supply is sucient during the calibration process. If the calibration
mode is forcibly excited due to shutdown or power failure, the calibration may fail, and the
data will be inaccurate, so you need to re-calibrate.
Press and hold the and buttons for 2 seconds.
1)
2)
3)
Note:

Red represents an unhealthy CO2level
(1501 to 5000 ppm)
CO2threshold level indication
Green represents a good CO2level
(400 to 1000 ppm)
Yellow represents the average CO2level
(1001 to 1500 ppm)
Note: When an increase in CO2concentration reaches a poorer level range, the buzzer
alarm is triggered.

Place Directly
(Bracket Included)
Tabletop Stand Magnetic Back

USB cable x 1
Detector x 1
User manual x 1
Bracket or accessories set x 1

Q: Why are there two modes?
A:
We oer two modes to cater to dierent usage scenarios. Mode is
suitable for situations where real-time monitoring of environmental
parameters is needed. It has a higher data collection frequency but shorter
battery life. This Mode is best suited for scenarios with frequent ecological
changes, such as traveling. For regular usage, we recommend selecting
the mode. The mode is designed for long-term monitoring,
oering a longer battery life but a lower data collection frequency.
Choose
the Mode that best suits your specific needs.
Q: Why does Mode have a shorter battery life?
A:
Mode has a higher data collection frequency, with data being
collected every minute. Therefore, it has a relatively shorter battery
life.

Q:
If I need to monitor CO2data for an extended period continuously, will
this impact the device's lifespan?
A:
According to Temtop Laboratory's testing, continuous real-time monitoring of
CO2data for an extended period has a negligible impact on the device's lifespan.
Q: Why is the temperature high when charging?
A:
The temperature and humidity sensor is located inside the product. When
charging, a large amount of heat will be generated, causing the actual
temperature of the product to rise.
Q: Why is CO2data high?
A:
The user's environment may be poorly ventilated, resulting in high CO2
concentration; it is recommended that the user place the product in an outdoor
ventilated place for 10 minutes. If the data is still high, the customer is
advised to calibrate according to the user manual.