VF
Read this manual carefully before installing, operating or servicing this equipment. It’s the responsi-
bility of the employer to ensure this manual is read by the operator. Please preserve this manual.
is document is issued with Product Serial No
Operation and Maintenance Guide

FF-MM-313-REV - 00
Page 2
Operation and Maintenance Guide Electric Portable Ventilation Fan
Table of Contents
3 Introducon
3 Technical Data
3 SafetyInstrucons
3 Operaon
3 Maintenance
4 Dimensional Data
5 TestCercateOfMaterials,Performance
6 EuDeclaraonOfConformity
7 WarrantyCercate

FF-MM-313-REV - 00
Page 3
Operation and Maintenance Guide Electric Portable Ventilation Fan
Technical Data
Product
Reference VF-200-100V VF-200-200V VF-300-100V VF-300-200V VF-400-200V
Casing
Diameter Ø200mm Ø200mm Ø300mm Ø300mm Ø400mm
Electric
Source 100V - 1ph 200V - 1ph 100V - 1ph 200V - 1ph 200V - 3ph
Air volume 20 M³/ min 20 M³/ min 70 M³/ min 70 M³/ min 110 M³/ min
Pressure 25mm Aq 25mm Aq 30mm Aq 30mm Aq 50mm Aq
R.P.M. 3000 3600 3000 3600 3000
Output 115 W 115 W 0.55 kW 0.55 kW 1.5 kW
Weight 9 kgs 9 kgs 18 kgs 18 kgs 35 kgs
Technical Data
Product
Reference VF-400-200V VF-400-400V VF-500-200V VF-500-200V VF-500-400V
Casing
Diameter Ø400mm Ø400mm Ø500mm Ø500mm Ø500mm
Electric
Source 200V - 1ph 400V - 3ph 200V - 3ph 200V - 1ph 400V - 3ph
Air volume 190 M³/ min 20 M³/ min 190 M³/ min 190 M³/ min 190 M³/ min
Pressure 70mm Aq 25mm Aq 70mm Aq 70mm Aq 70mm Aq
R.P.M. 3600 3000 3600 3600 3600
Output 3.7 kW 115 W 3.7 kW 3.7 kW 3.7 kW
Weight 64 kgs 9 kgs 64 kgs 64 kgs 64 kgs
Safety Instructions
a. Shut o the power urgently when any
abnormalities occur in operation.
b. e unit must not be installed at place that
suers from severe water leakage.
c. It’s absolutely prohibited to insert nger
or thin bar to the safety grille guard for
avoiding being injured or damaging the
appliance
d. young children should be supervised to
ensure that don’t play with the appliance.
Operation
a. Turn on/o the switch button to make the
unit run/stop
b. Running the air-ventilation fan can exhaust
odors and steam in a quick and ecient way.
c. e VF series air-ventilation fan can be
widely used in underground cable main-
tenance, shipping marking, re ghting,
piping construction, oil machinery, chemical
machinery, medicine machinery and other
hazardous situation for ventilation .
Introduction
Teryair Electric Ventilation Fans are highly ecient and portable. Used to ventilate hot air and
harmful gases from a tank or work area, and supply fresh air. e ideal bell mouth type casing is
highly ecient, creates little noise and is easy to install in an air duct. Ducting tubes sold separately.

FF-MM-313-REV - 00
Page 4
Operation and Maintenance Guide Electric Portable Ventilation Fan
Dimensional Data
Model covered
Model Number L D1 D H
VF-200-100V 350 270 210 330
VF-200-200V 340 275 205 330
VF-300-100V 385 380 305 430
VF-300-200V 375 380 305 430
VF-400-200V 445 480 405 705
VF-500-200V 470 580 505 765
Maintenance
a. Shut o power before cleaning or
maintenance.
b. Wipe casing and impeller with care using a
so cloth soaked with water or neutral
detergent ensure the motor or other
electrical parts cannot touch the water .
c. Lubricate axles aer approx 1000 hours of
running.

FF-MM-313-REV - 00
Page 5
Operation and Maintenance Guide Electric Portable Ventilation Fan
TEST CERTIFICATE OF MATERIALS, PERFORMANCE
Date :
Model number :
Part description & s.No. :
We hereby certify that the above referenced product has tested and inspected in accordance with our standard test procedures
and meets the specications for material and performance values as published in our literature. We further certify that the prod-
uct has been given our standard factory test and meets all quality and performance standards established by the company. is
product is certied to be produced in our factory, and is of current production.
Authorised Signatory
Q.A Manager
Place - Vasai, Maharastra

FF-MM-313-REV - 00
Page 6
Operation and Maintenance Guide Electric Portable Ventilation Fan
EU DECLARATION OF CONFORMITY
We hereby certify that the Listed Product stipulated below comply with all relevant provisions of the machinery direc-
tive (2006/42/EC) and the national laws and regulations adopting this directive.
Description :
Model Number :
Date :
Serial Number :
Is in conformity with the provisions of the following European Directives: (2006/42/EC) Machinery Safety and
Harmonized standards
ISO 12100-1: 2010: Safety of Machinery –general Principles for Design –Risk Assessment and Risk Reduction.
Registered Oce : 416 Gundecha Industrial Complex, Akuril Road,
Kandivali East, Mumbai – 400101, Maharashtra, India.
Web site : www.teryair.com
Works : A-1, Tirupati Udyog Nagar, Sativali Road, Vasai East,
Palghar – 401208, Maharashtra, India.
CE certication registration no – C E 16831
Issued by – BMQR Certications Pvt Ltd.
www.cemarking-india.com
Valid Till – 03/11/2021
Signed for and on behalf of
TERYAIR EQUIPMENT PVT. LTD. Place of Issue:
Date:

FF-MM-313-REV - 00
Page 7
Operation and Maintenance Guide Electric Portable Ventilation Fan
Warranty Certificate
Every product manufactured by Teryair
is built to meet the highest standards of quality.
Teryair warrants that the Products, accessories and parts manufactured or supplied
by the company be free from defects in material and workmanship for a period of six
months from date of Teryair authorized dealer invoice to customer, or one year from
date of Teryair invoice to dealer, whichever is earlier. Failure due to normal wear,
misapplication, or abuse is, of course, excluded from this warranty.
Since the use of Teryair products and parts is beyond our control, Teryair cannot
guarantee the suitability of any product or part for a particular application and Teryair
shall not be liable for any consequential damage or expense arising from the use or
misuse of its products on any application. Teryair does not warranty bought out
products or components such as electric motors and hardware but will assist in
directing warranty queries to the dealer/manufacturer responsible. Teryair
responsibility is limited solely to replacement or repair of defective Teryair products
or components.
Dealer/End User shall have no right or remedy and Teryair shall have no liability or obligation under the warranty, if:
(i) a Product is altered, changed, modified or tampered with in any way, (ii) a Product is damaged after deposit with the
transporter for shipment; (iii) a Product is not properly preserved, packaged, stored, processed or handled after receipt; (iv) a
Product is not used and maintained in accordance with Teryair's recommended operating and maintenance manuals,
instructions and procedures, if any; (v) a Product is not properly incorporated or installed in, or not properly combined with, an
Other Product; (vi) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises
out of, a failure, substandard performance or other issue with another product, material, component or part not supplied by
Teryair; (vii) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises out of,
compliance with any design, specification or other specific requirement of Dealer/End User; (viii) a Product is used in a manner,
with a substance or for a purpose other than the normal manner, substance and purpose for which it is intended or is otherwise
subjected to abnormal use or service; (ix) a Product is subjected to a power surge, brown out or other similar occurrence; (x)
the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises out of, normal wear
and tear of such Product (including, without limitation, things such as worn seals, diaphragms, balls, O rings, gaskets, chisels,
cutters, hoses and other such wearing components; (xi) the issue with a Product is directly or indirectly.
Dated :
Product Model Number :
Product Serial Numbar : Ajay Bhagat, Q.A. Manager
(Company Seal)

FF-MM-313-REV - 00
Page 8
Operation and Maintenance Guide Electric Portable Ventilation Fan
is page is intentionally
Le blank.
This manual suits for next models
16
Table of contents
Other Teryair Fan manuals
Popular Fan manuals by other brands

Gallet
Gallet Blizzard VEN30 instruction manual

Fancom
Fancom I-fan 35 Xtra manual

Greenheck
Greenheck DF-18 Installation, operation and maintenance manual

Revel AIR
Revel AIR ALBANY Series instruction manual

Panasonic
Panasonic FV-08-11VFL5 Service manual

McKenzie Martin
McKenzie Martin MACKRIDGE OPERATION, SERVICE AND MAINTENANCE SCHEDULE