ČAROBNA PEĆ
Owners’s manual
INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION
EN
13240
2
INTRODUCTION
Congratulations!
You have invested in energy efficient and high quality product – CAROBNA PEC burning
stove.
Your purchase will provide you years of clean and comfortable heating with minimal maintenance.
Please read this manual in its entirety. Its purpose is to familiarize you with your stove safe installation,
operation and maintenance. It contains information that will be useful to you now and in years to come, so
keep it handy and refer to it as needed.
Be sure to maintain the designated stovepipe and stove clearances to walls, ceilings, hearth, and other
combustible surfaces. This will help reduce the risk of fire.
Failure to follow these instructions can result in property damage, bodily injury, and even death!
Locate your stove in a safe, convenient, open area, away from traffic flow, doors and hallways,near to a
chimney and chimney connector.
PURPOSE
CAROBNA PEC stove is designed for heating.
TECHNICAL DATA
Dimensions (W x D x H)
(mm)
490 x 510 x 835
Fire box dimensions (W x D x H)
(mm)
300 x 350 x 250
Nominal thermal output
(KW)
10
Appliance efficiency
%
87
Exhaust diameter
(mm)
Ø
120
Fuel type
wood, wood briquettes
Temperature of the gases
C
134
Dust content of exhaust gases
mg/m3
D=65
CO (13%O2)
%
0,1163
Net weight
(kg)
49
,00
Brutto weight
(kg)
53
,
0
0
3
APPEARANCE AND PARTS
1. Top plate
2. Flue outlet
3. Secondary air regulator
4. Secondary air
5. Tertiary air
6. Firebox doors
7. Grid carrier
8. Grid
9. Primary air regulator
10. Ash pan
4
DIMENSIONS
A
B
C
D
E
F
245mm
510mm
835mm
110mm
490mm
Ø120
5
INSTALLING OF WOOD BURNING STOVE
Unpacking and installing
TIM SISTEM is packing your stove with care so it could be savely transported. However, some damage can
occur during transport.
When you receive your stove, unpack it carefully, inspecting your stove and all parts for damage. Make
sure that all parts are included in the box. If any parts are damaged or missing, please contact your dealer
immediately.
After choosing an appropriate spot, inspect this location to make sure that the stove will have enough
clearance to combustible materials. These combustibles can include walls, floor, ceiling, cabinets, fireplace,
and chimney. You must carefully consider the clearances to all of these combustibles before actually
connecting your stove. When considering these clearances, also decide the kind of floor the stove will rest
on. Depending on your floor, you can install your stove as it is, or use a floor protector, some types of
flooring may require additional floor protection. A floor protector is any noncombustible surface laid on the
floor underneath the stove that extends, 50cm beyond the fuel loading door and 10cm beyond each side of
the stove
PRECAUTION MEASURES
Read and understand this Owner's Manual thoroughly before installing and using CAROBNA PEC
wood stove.
Make sure to install your stove:
According to the manufacturer's recommendations.
In accordance with all applicable codes.
With the proper sized chimney.
When using your stove:
Warn children and others unfamiliar with wood-fired stoves about the danger of touching hot,
radiating surfaces of your stove. For your additional safety, obtain hearth and stove guards through
your local dealer.
Keep pets away from the stove to prevent unnecessary hazards.
Burn natural wood or briquttes only. Higher efficiencies and lower emissions result when burning air-
dried, seasoned wood, as compared to green or freshly cut wood.
Use caution when loading firewood into a hot stove.
Keep the fuel loading door closed at all times except when loading wood.
Keep the ash pan fully inserted.
Clean the surface regularly.
Never modify this stove in any way.
Never burn kiln dried wood, painted or treated wood, solvents, trash, plywood, colored or
glossy paper, artificial logs, cardboard, coal, garbage or driftwood.
Especially, do not burn coal in this stove!
6
CONNECTION TO CHIMNEY
After getting familiar with your stove and its part and before you connect it to a chimney, check the quality of
the chimey.
Exhaust pipes and connection to chimney must go up ways
Horizontal parts of fumepipes should not be longer than 0,5m and they should always rise away
from stove a minimum of 10 torward chimeny.
Fume pipes diameter should not get smaller.
All connections must be tight , pipes and chimney must be clean and without any kind of dirt.
Chimney must be protected from cold (insulated) especially in the case of metal chimney and in
the case of exterior masonry chimney.
Non vertical fume pipes which don’t have insulation should not be longer than 1,25m
Chimney must fulfill the following conditions:
Chimney goes above roof minimum 0,5m.
Chimney should be higher than the first house next to it, higher than tree or any other obstacle.
Interior chimney is preferable and exterior chimney must be well insulated.
Chimney must be clean of any kind of dirt, bird nests or similar obstacles.
Stovepipe must not be attached to deep in to chimney because it decrease fuming out .
All unnecessary holes or cleaning doors on the chimney must be closed.
7
8
BUILDING A FIRE
Once you understand the controls of your wood stove and have chosen the appropriate firewood, you are
ready to start a fire.
When you light your first fires, the wood stove will emit some smoke and fumes. This is normal "off-gassing"
of the paints and oils used when manufacturing the wood stove. If you find it necessary, open a few
windows to vent your room. The smoke and fumes will usually subside after 10 to 20 minutes of operation.
The odor and smoke will end once the stove is "cured".
Starting fire
1. Open the door and place sheets of tightly twisted newspaper in the center of the firebox. Arrange
kindling in a crisscross pattern over the newspaper. Kindling should be approximately ten pieces.
2. Fully open the primary air control
3. Light the paper under the kindling
4. Close the door and allow the fire to burn.
5. Once the kindling is burning, open the door and add logs.
6. Once the fire is burning well, use the primary air control to regulate the desired rate of burn.
WARRANTY STATEMENT
Warranty is valid from the day of purchase which buyer can prove with verified and signed warranty protocol.
Protocol include details about buyers address, date of purchase, signature and stamp of dealer or his
service representative. Detailed warranty protocol must be made and verified by TIM SISTEM dealer.
Warranty will be acknowledged under following conditions:
Product was handled according to instructions
Product was not
damaged
Warranty protocol is verified by TIM SISTEM dealer or his representative
Name of product
Serial No.
Date of purchase
Signature and stamp of dealer or
his service representative
CAROBNA PEC

Other Tim Sistem Stove manuals

Tim Sistem LEDERATA PLUS User manual

Tim Sistem

Tim Sistem LEDERATA PLUS User manual

Tim Sistem CAROBNA HYDRO User manual

Tim Sistem

Tim Sistem CAROBNA HYDRO User manual

Tim Sistem Magic User manual

Tim Sistem

Tim Sistem Magic User manual

Tim Sistem rittium 14 hydro User manual

Tim Sistem

Tim Sistem rittium 14 hydro User manual

Tim Sistem RITTIUM 6 User manual

Tim Sistem

Tim Sistem RITTIUM 6 User manual

Tim Sistem RITTIUM CTP User manual

Tim Sistem

Tim Sistem RITTIUM CTP User manual

Tim Sistem Rittium 14 User guide

Tim Sistem

Tim Sistem Rittium 14 User guide

Popular Stove manuals by other brands

Verner 13 Operation and installation manual

Verner

Verner 13 Operation and installation manual

Tecnoinox PF70G7 instruction manual

Tecnoinox

Tecnoinox PF70G7 instruction manual

Dovre TAI 45M Installation instructions and operating manual

Dovre

Dovre TAI 45M Installation instructions and operating manual

wiking Miro 4 Mounting

wiking

wiking Miro 4 Mounting

Moretti Design TURBO ELEGANCE CLEAN GLASS A 9 DEDICATED MANUAL

Moretti Design

Moretti Design TURBO ELEGANCE CLEAN GLASS A 9 DEDICATED MANUAL

Jøtul GF 300 BV Allagash Installation and operation instructions

Jøtul

Jøtul GF 300 BV Allagash Installation and operation instructions

Lennox Elite series Installation and operation

Lennox

Lennox Elite series Installation and operation

Koolatron LBS-01 owner's manual

Koolatron

Koolatron LBS-01 owner's manual

Dru Cosmo RCH installation manual

Dru

Dru Cosmo RCH installation manual

Napoleon 1600C-1 Installation and operation instructions

Napoleon

Napoleon 1600C-1 Installation and operation instructions

EdilKamin MILLA H 15 Up Directions for installation, use and maintenance

EdilKamin

EdilKamin MILLA H 15 Up Directions for installation, use and maintenance

Pacific energy TRENTON A Installation and operating instructions

Pacific energy

Pacific energy TRENTON A Installation and operating instructions

Defro Home MYPELL operating manual

Defro Home

Defro Home MYPELL operating manual

NorthStar MSTOVEF CS550 user guide

NorthStar

NorthStar MSTOVEF CS550 user guide

Leenders FUGA eL MkII Installation

Leenders

Leenders FUGA eL MkII Installation

Regency Fireplace Products GF40 manual

Regency Fireplace Products

Regency Fireplace Products GF40 manual

EVA Stampaggi COSTANZA instruction manual

EVA Stampaggi

EVA Stampaggi COSTANZA instruction manual

Cumberland Stove Works MF3500 Installation and operation manual

Cumberland Stove Works

Cumberland Stove Works MF3500 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.