manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TJERNLUND
  6. •
  7. Fan
  8. •
  9. TJERNLUND V1, V1D, V2D CRAWL SPACE VENTILATORS 8500720 User manual

TJERNLUND V1, V1D, V2D CRAWL SPACE VENTILATORS 8500720 User manual

This manual suits for next models

1

Other TJERNLUND Fan manuals

TJERNLUND DSF2B User manual

TJERNLUND

TJERNLUND DSF2B User manual

TJERNLUND UC1 User manual

TJERNLUND

TJERNLUND UC1 User manual

TJERNLUND HS-3 User manual

TJERNLUND

TJERNLUND HS-3 User manual

TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A... User manual

TJERNLUND

TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A... User manual

TJERNLUND HS-3 User manual

TJERNLUND

TJERNLUND HS-3 User manual

TJERNLUND DRAFT INDUCER DJ-3 User manual

TJERNLUND

TJERNLUND DRAFT INDUCER DJ-3 User manual

TJERNLUND VP-2, VP-3 8500567 0702 User manual

TJERNLUND

TJERNLUND VP-2, VP-3 8500567 0702 User manual

TJERNLUND HSJ User manual

TJERNLUND

TJERNLUND HSJ User manual

TJERNLUND 1 User manual

TJERNLUND

TJERNLUND 1 User manual

TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504105 REV... User manual

TJERNLUND

TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504105 REV... User manual

TJERNLUND AD-1 DRAFT INDUCER FOR WOOD BURNING STOVES 8500672 REV. 1... User manual

TJERNLUND

TJERNLUND AD-1 DRAFT INDUCER FOR WOOD BURNING STOVES 8500672 REV. 1... User manual

TJERNLUND AIRESHARE AS2 User manual

TJERNLUND

TJERNLUND AIRESHARE AS2 User manual

TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504102 REV... User manual

TJERNLUND

TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504102 REV... User manual

TJERNLUND Duct Booster RB10 User manual

TJERNLUND

TJERNLUND Duct Booster RB10 User manual

TJERNLUND HSJ User guide

TJERNLUND

TJERNLUND HSJ User guide

TJERNLUND 950-2064 L-185 SAFETY INTERLOCK KIT 8504020 REV 3... User manual

TJERNLUND

TJERNLUND 950-2064 L-185 SAFETY INTERLOCK KIT 8504020 REV 3... User manual

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... User manual

TJERNLUND

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... User manual

TJERNLUND HSJ User manual

TJERNLUND

TJERNLUND HSJ User manual

TJERNLUND EF-6AUTO User manual

TJERNLUND

TJERNLUND EF-6AUTO User manual

TJERNLUND 950-8302 T-STAT KIT 8504132 User manual

TJERNLUND

TJERNLUND 950-8302 T-STAT KIT 8504132 User manual

TJERNLUND HS-5 User manual

TJERNLUND

TJERNLUND HS-5 User manual

TJERNLUND EF DUCT BOOSTER FANS 8504057 REV.793 User manual

TJERNLUND

TJERNLUND EF DUCT BOOSTER FANS 8504057 REV.793 User manual

TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504102 REV C... User manual

TJERNLUND

TJERNLUND SS1 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504102 REV C... User manual

TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B... User manual

TJERNLUND

TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B... User manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UnderAire™
Crawl Space Ventilators
Fan powered crawl space ventilation
quickly reduces moisture helping to
protect both home and occupants.
TTJJEERRNNLLUUNNDD
Model V2D
Two fans and large faceplate
sized for ventilation openings
through block foundations.
Includes thermostat, dehumidi-
stat and pre-wired 6’ power
cord.
Model V1D
One fan and large faceplate sized
for ventilation openings through
block foundations. Includes
thermostat, dehumidistat and
pre-wired 6’power cord.
Three models to choose from:
Model V1
One fan and small faceplate for
ventilation openings through brick
foundations. (Requires switch or
dehumidistat to activate. Multiple
ventilators may be controlled by a
single switch or dehumidistat).
Includes thermostat.
Suitable for Damp Locations
■Ventilates excess moisture,
the cause of mold, mildew
and wood rot. Increases air
circulation to fight
condensation.
■Constant operation helps vent
radon, treated wood off-
gassing and odors that might
otherwise migrate into living
areas.
Facts to know
about Crawl Space
Ventilation
From Mississippi State University
Extension Service:
■ If soil is damp, as much as 20 gallons
of water per 24 hours can evaporate
into the air in a 1,400 sq. ft crawl
space.
■ Primary causes of excess moisture
include:
●Surface runoff water
●Poor ventilation
●No or poor ground vapor barrier
■ Signs of excess moisture in crawl
space:
●Soil is wet
●Surface organism growth on
floor joists
●Wet insulation
●Musty odors in crawl space or
living areas
●Excessive moisture in living areas
tending to migrate towards
windows
TJERNLUND PRODUCTS, INC.
1601 Ninth Street White Bear Lake, MN 55110-6794
Phone: 651.426.2993 800.255.4208 Fax: 651.426.9547
Visit our web site: www.tjernlund.com
Copyright © 2006 Tjernlund Products, Inc. P/N 8500720
UnderAireTM
Crawl Space Ventilators
Easy to install
Designed and engineered
for years of service
How to determine the number of
UnderAire™ Ventilators needed:
Galvanized face
plate may be
trimmed if
necessary
Thermostat
deactivates fan
below 400F to
avoid freeze-ups
Ventilators are
installed inside crawl
space behind existing
ventilation opening.
Screws and masonry
wall anchors are
included.
Sealed bearing
motor(s)
Complete details on Tjernlund Crawl Space Ventilators are available from your Tjernlund distributor or at www.tjernlund.com
Models V1D and
V2D have 6'
grounded power
cord
Model V1 V1D V2D
Performance 110 CFM 110 CFM 220 CFM
Motor 115/1/60 115/1/60 2 @ 115/1/60
0.30 amps 0.30 amp 0.60 amps
Dehumidistat OFF/ON or OFF/ON or
20-80% RH 20-80% RH
Thermostat Opens at 400F Opens at 400F Opens at 400F
Dimensions 14 3/8” x 6 7/8” x 2” 18” x 9” x 2” 18” x 9” x 2”
Specifications
ModelsV1D &V2D ModelV1
Models V1D and V2D
include adjustable
dehumidistat
Calculate the cubic area of the crawl space by multiplying the length x width x
height. Divide this number by 15 to determine the minimum CFM necessary to
fully ventilate the space in 15 minutes. Example: 20' wide x 40' long x 3' high
crawl space = 2,400 cubic ft. 2400 cubic ft. ÷15 minutes = 160 CFM of
ventilation. Choose two V1 or V1D ventilators or one V2D ventilator.
Other Tjernlund
ventilation products
In-Forcer™
fresh air and
combustion air
intake fans
automatically
bring outdoor
air into tightly
sealed homes.
Duct Booster®
fans boost airflow
to hard-to-heat
or cool rooms.
Capacities from
150 to 1,200 CFM.
Optional Model DH10
dehumidistat available
separately