ZT-SLIM User’s Manual
13) Calibration Procedures
1) Before calibrating the unit, verify each piece of hardware is connected and set up properly.
2) With the sensors placed in the best possible location, (see appendix), torque the sensors
down to 150 in-lbs on the sensor bolts. Do not put the sensor enclosure covers on yet.
You will need to test each sensor location.
3) Find the shut height of the press.
•Jog the press until the ram is at bottom dead center (BDC) or 180º without the load cells
or die in the press.
•Determine the amount of spacers needed with your load cell. Cycle the press without
load cells to insure correct height.
4) Place the load cells in the correct position in the press.
•All load cells should be equal distance from the sides and front and rear. For example,
12” from the sides, 10” from front and rear. Load cells are typically placed at each
corner of the press’s bed.
•Cycle the press without hitting the load cells first.
•Place cardboard on the top and bottom of the load cells.
5) Set ZT-4 dip-switches as shown. set all gain pots to fully clockwise, then dial each gain pot
about 12 turns counter-clockwise to start.